Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in April 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This presentation presents relevant results of the post-test inspection for both discharge and neutralizer cathodes.

Lifetime↗

Exposing NASA's Earth Observations to the Applications Community and Public

NASA's Earth Observing System (EOS) generates a wealth of data products which are generally intended for scientific research. In recent years, however, this data has also become more accessible to the applications community and public through the Worldview app and Global Imagery Browse Services (GIBS). These mapping interfaces provide historical and near real time access to NASA's Earth observations for a wide range of uses. This presentation will focus on how the applications community, public, and media use these interfaces for decision-making, leisure, and anything in between.

web mappin↗

Space Weather Forecasting at NASA GSFC Space Weather Research Center

The NASA GSFC Space Weather Research Center (http://swrc.gsfc.nasa.gov) is committed to providing research forecasts and notifications to address NASA's space weather needs - in addition to its critical role in space weather education. We provide a host of services including spacecraft anomaly resolution, historical impact analysis, real-time monitoring and forecasting, tailored space weather alerts and products, weekly summaries and reports, and most recently - video casts. In this presentation, we will focus on how near real-time data (both in space and on ground), in combination with modeling capabilities and an innovative dissemination system called the Integrated Space Weather Analysis System (iSWA http://iswa.gsfc.nasa.gov), enable space weather forecasting and quality space weather products provided by our Center. A few critical near real-time data streams for space weather forecasting will be identified and discussed.

CMEs↗

TPSAS-NF1676L-32099-DND

This talk provides a short overview of the new POWER web site that provides data parameters to energy sector societal benefit areas from NASA research projects. The NASA research projects include the GEWEX Surface Radiation Budget project, the CERES Fast Shortwave and Longwave radiative flux project (FLASHFlux) and NASA Goddard's Global Modeling and Assimilation Office (GMAO) MERRA-2 atmospheric reanalysis. Data products are customized to the energy industry and make products available from the daily time scale to long-term climatological averages. The web services allow uses to choose multiple parameters and obtain the data in multiple file formats. This short talk is designed to be delivered at the NASA booth area at the 2018 Fall American Geophysical Union conference.

Paul W Stackhouse, Jr.↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 h of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Ion engine↗

Northeast Alaska Climate: Using Earth Observations to Evaluate Snow Variability through a Climatological Analysis to Support Ecological Monitoring in Northeast Alaska

Alaska is experiencing climate change at an unprecedented rate, with temperatures increasing twice as fast as the national average. The resulting changes to the landscape and ecosystems are significant, including shorter winters, declining snow depth, thawing permafrost, and rapidly receding glaciers. These changes are not only exacerbating the negative impacts of oil exploration but also affecting the food security of indigenous communities that rely on hunting as a subsistence food source. With the US Fish and Wildlife Service managing a potential tundra travel season for the first time in its history, adequate data on historic snow variables is essential to protect the unique habitat of the area. This project used NASA satellite and assimilation system data to inform and improve the current understanding of snow patterns in the Arctic National Wildlife Refuge and the National Petroleum Reserve – Alaska. The DEVELOP team used MODIS Normalized Difference Snow Index data to determine snow season duration, snow change frequency, and the first and last days of snow. The team also utilized the 2.1 Global Land Data Assimilation System and Daymet V4 products to study climatological trends in snow depth and snow water equivalent, respectively, across the study areas. The results of this study give users the capacity to visualize maps of multiple snow variables to monitor changes in snow conditions and proactively prepare for the ecological, cultural, and landscape impacts that changes in snow variability will cause in the future.

Remote Sensing↗

An In-Time Aviation Safety Management System (IASMS) Concept of Operations for Part 139 Airports

Today’s airports are complex multi-faceted ecosystems. Currently, of the 517certificatedairports, 270arerequired to use safety management systems (SMSs) to identify and mitigate known hazards and emergent risks and to voluntarily share safety data with commercial operators and tenants. Airports manage a wide variety of hazards. These traffic hubs have direct responsibilities, such as removing foreign object debris from runways and taxiways and configuring runways to help prevent against incursions and tail strikes during takeoff. To ensure safety in the future NAS, the National Academies recommended an In-time Aviation Safety Management System (IASMS). An IASMS will employ services, functions, and capabilities (SFCs) to identify and mitigate hazards that are proactively and predictively managed based on data analytics of detected anomalies, precursors, and trends. SFCs would scale with airport complexity and environmental conditions using increasingly automated systems to respond proactively to hazards and, by using integrated data sources and predictive safety analytical methods, discover new, never before seen risks.

Ellis, K↗

In-Time Safety Management for Part 139 Airports

Today’s airports are complex multi-faceted ecosystems. Currently, of the 517 certificated airports, 270 are required to use safety management systems (SMSs) to identify and mitigate known hazards and emergent risks and to voluntarily share safety data with commercial operators and tenants. Airports manage a wide variety of hazards. These traffic hubs have direct responsibilities, such as removing foreign object debris from runways and taxiways and configuring runways to help prevent against incursions and tail strikes during takeoff. To ensure safety in the future NAS, the National Academies recommended an In-time Aviation Safety Management System (IASMS). An IASMS will employ services, functions, and capabilities (SFCs) to identify and mitigate hazards that are proactively and predictively managed based on data analytics of detected anomalies, precursors, and trends. SFCs would scale with airport complexity and environmental conditions using increasingly automated systems to respond proactively to hazards and, by using integrated data sources and predictive safety analytical methods, discover new, never before seen risks.

IASMS↗

Optimal charging management and infrastructure planning for free-floating shared electric vehicles

Recently, major car-sharing service providers have begun to include electric vehicles (EVs) in free-floating car-sharing fleets. For these EVs, downtime due to charging, including time spent traveling to and waiting in queues at charging stations in a sparse charging infrastructure network, is a major barrier to sustainable operation. An intuitive solution to overcome this barrier is to increase the number of fast-charging stations in the fleet service area. This paper studies the relationship between fleet vehicle downtime and the number of charging stations by modeling the fleet operations of a major car-sharing service provider. An integer programming model is developed that jointly optimizes charging station allocation, in terms of the number and location of charging stations, and the assignment of EVs to charging stations. Case study results showed that fleet vehicle charging time comprises 72-75% of the total downtime spent on charging trips. This indicates that charging time, as opposed to travel time or waiting time, is the dominant component of total fleet downtime for charging. The study also shows that by adding 5 to 20 new charging stations reduces total fleet downtime and travel time during charging trips by 2-4% and 26-49%, respectively. Although adding new charging stations to the fleet service area reduces total charging trip travel time significantly, it does not reduce total downtime significantly. Results also show that if the EV battery state of the charge (SOC) threshold—below which a charging trip is initiated—is less than 18%, not all EVs in the car-sharing fleet can be charged using the existing direct current fast chargers (DCFCs) in the fleet’s service area. Furthermore, this implies that adequate charging infrastructure coverage is required to ensure that EVs of a given range can operate in the car-sharing fleet.

25 ENERGY STORAGE↗

Pooled Rideshare in the U.S.: An Exploratory Study of User Preferences

Pooled ridesharing offers on-demand, one-way, cost-effective transportation for passengers traveling in similar directions via a shared vehicle ride with others they do not know. Despite its potential benefits, the adoption of pooled rideshare remains low in the United States. This exploratory study aims to evaluate potential service improvements and features that may increase users’ willingness to adopt the service. The study analyzed transportation behaviors, rideshare preferences, and willingness to adopt pooled rideshare services among 8296 U.S. participants in 2025, building on findings from a 2021 nationwide survey of 5385 U.S. participants. The study incorporated 77 actionable items developed from the results of the 2021 survey to assess whether addressing specific user-generated topics such as safety, reliability, convenience, and privacy can improve pooled rideshare use. A side-by-side comparison of the 2021 and 2025 data revealed shifts in transportation behavior, with personal rideshare usage increasing from 22% to 28%, public transportation from 21% to 27%, and pooled rideshare from 6% to 8%, while personal vehicle (79%) use remained dominant. Participants rated features such as driver verification (94%), vehicle information (93%), peak time reliability (93%), and saving time and money (92–93%) as most important for improving rideshare services. A pre-to-post analysis of willingness to use pooled rideshare utilizing the actionable items as per respondents’ preferences showed improvement: “definitely will” increased from 15.9% to 20.1% and “probably will” rose from 35.6% to 47.7%. These results suggest that well-targeted service improvements may meaningfully enhance pooled rideshare acceptance. This study offers practical guidance for Transportation Network Companies (TNCs) and policymakers aiming to improve pooled rideshare as well as potential future research opportunities.

Transportation Network Companies (TNCs)↗

University participation via UNIDATA, part 2

The University Corporation for Atmospheric Research (UCAR) is presently completing UNIDATA, Phase II, considered to be the design phase of the UNIDATA Project. The four major components of the UNIDATA System are: (1) global services which access is provided, (2) long haul communication for providing that access, (3) local services for providing access and local management of acquired data, and (4) local interactive processing and graphical display. Each component is described in detail with linkages among the components elucidated. Within this framework, access to the PCDS is discussed. It is pointed out that access to the PCDS could occur via general purpose computer-to-computer communications providing remote log on to the system. The UNIDATA System could also be used to transfer information from the PCDS, provided the appropriate software is available to receive the data. Both of these scenarios require agreements on the access protocols and appropriate physical connections. Universities' needs for weather information on a near real-time basis, and UNIDATA has already established a satellite broadcast data service for this purpose.

Fulker, D. W.↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Information logistics: A production-line approach to information services

Logistics can be defined as the process of strategically managing the acquisition, movement, and storage of materials, parts, and finished inventory (and the related information flow) through the organization and its marketing channels in a cost effective manner. It is concerned with delivering the right product to the right customer in the right place at the right time. The logistics function is composed of inventory management, facilities management, communications unitization, transportation, materials management, and production scheduling. The relationship between logistics and information systems is clear. Systems such as Electronic Data Interchange (EDI), Point of Sale (POS) systems, and Just in Time (JIT) inventory management systems are important elements in the management of product development and delivery. With improved access to market demand figures, logisticians can decrease inventory sizes and better service customer demand. However, without accurate, timely information, little, if any, of this would be feasible in today's global markets. Information systems specialists can learn from logisticians. In a manner similar to logistics management, information logistics is concerned with the delivery of the right data, to the ring customer, at the right time. As such, information systems are integral components of the information logistics system charged with providing customers with accurate, timely, cost-effective, and useful information. Information logistics is a management style and is composed of elements similar to those associated with the traditional logistics activity: inventory management (data resource management), facilities management (distributed, centralized and decentralized information systems), communications (participative design and joint application development methodologies), unitization (input/output system design, i.e., packaging or formatting of the information), transportations (voice, data, image, and video communication systems), materials management (data acquisition, e.g., EDI, POS, external data bases, data entry) and production scheduling (job, staff, and project scheduling).

Adams, Dennis↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report of experiments and evidence for ASC L2 milestone 4467: demonstration of a legacy application's path to exascale

This report documents thirteen of Sandia's contributions to the Computational Systems and Software Environment (CSSE) within the Advanced Simulation and Computing (ASC) program between fiscal years 2009 and 2012. It describes their impact on ASC applications. Most contributions are implemented in lower software levels allowing for application improvement without source code changes. Improvements are identified in such areas as reduced run time, characterizing power usage, and Input/Output (I/O). Other experiments are more forward looking, demonstrating potential bottlenecks using mini-application versions of the legacy codes and simulating their network activity on Exascale-class hardware. The purpose of this report is to prove that the team has completed milestone 4467-Demonstration of a Legacy Application's Path to Exascale. Cielo is expected to be the last capability system on which existing ASC codes can run without significant modifications. This assertion will be tested to determine where the breaking point is for an existing highly scalable application. The goal is to stretch the performance boundaries of the application by applying recent CSSE RD in areas such as resilience, power, I/O, visualization services, SMARTMAP, lightweight LWKs, virtualization, simulation, and feedback loops. Dedicated system time reservations and/or CCC allocations will be used to quantify the impact of system-level changes to extend the life and performance of the ASC code base. Finally, a simulation of anticipated exascale-class hardware will be performed using SST to supplement the calculations. Determine where the breaking point is for an existing highly scalable application: Chapter 15 presented the CSSE work that sought to identify the breaking point in two ASC legacy applications-Charon and CTH. Their mini-app versions were also employed to complete the task. There is no single breaking point as more than one issue was found with the two codes. The results were that applications can expect to encounter performance issues related to the computing environment, system software, and algorithms. Careful profiling of runtime performance will be needed to identify the source of an issue, in strong combination with knowledge of system software and application source code.

99 GENERAL AND MISCELLANEOUS↗

Development and Calibration of an Online Energy Model for AHU Fan

The model development is necessary for the study of the energy consumption of Heating, Ventilation, and Air Conditioning (HVAC) systems. To predict the HVAC energy consumption accurately, one needs to model the individual HVAC components either from the measured data or based on the knowledge of the underlying physical phenomenon. Online model characterization is critical for improving the performance of real-time model-based fault detection and diagnosis (FDD) strategies. For HVAC control, models can be used to optimize the supervisory and local feedback control strategies to improve the energy consumption efficiency, or for providing ancillary services to the grid. It has been reported that, fans in HVAC systems of commercial buildings alone can provide substantial frequency regulation service, with little change in the indoor environment. In this paper, a real-time data-driven Air Handling Unit (AHU) fan model was developed based on recursive multi regression model. A generic nonlinear polynomial model has been studied to cover scenarios with different combinations of measurement variables, variable orders as well as different training and prediction horizons. Typical measurements including static pressure, mass flow rate, and damper positions are utilized as inputs to model the power consumption of the fan. The developed models have been validated both with simulation data from EnergyPlus-Dymola co-simulation model and with field measurement data for small to medium commercial buildings. The validation results show that the online model proposed can provide an effective prediction of the AHU fan power consumption.

Dong, Jin↗