Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Efficient fault diagnosis of helicopter gearboxes

Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.

Chin, H.↗

Accelerating Ground-Test Cycle Time: The Six-Minute Model Change and Other Visions for the 21st Century

The advantage of managing organizations to minimize product development cycle time has been well established. This paper provides an overview of the wind tunnel testing cycle time reduction activities at Langley Research Center (LaRC) and gives the status of several improvements in the wind tunnel productivity and cost reductions that have resulted from these activities. Processes have been examined and optimized. Metric data from monitoring processes provides guidance for investments in advanced technologies. The most promising technologies under implementation today include the use of formally designed experiments, a diverse array of quick disconnect technology and the judicious use of advanced electronic and information technologies.

Kegelman, Jerome T.↗

Nondestructive Evaluation and Monitoring Results from COPV Accelerated Stress Rupture Testing, NASA White Sands Test Facility (WSTF)

Develop and demonstrate NDE techniques for real-time characterization of CPVs and, where possible, identification of NDE capable of assessing stress rupture related strength degradation and/or making vessel life predictions (structural health monitoring or periodic inspection modes). Secondary: Provide the COPV user and materials community with quality carbon/epoxy (C/Ep) COPV stress rupture progression rate data. Aid in modeling, manufacturing, and application of COPVs for NASA spacecraft.

Saulsberry Regor↗

NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

Automotive↗

Infant Mortality and Wear-Out Failures in Polymer and MnO2 Tantalum Capacitors

Reliability testing of modern tantalum capacitors shows the presence of both types, infant mortality (IM) and wearout (WO) failures. To assure reliable operation, the probability of IM failures should be reduced to below the specified level, and the time of WO inception should be greater than the required useful life of the parts at operation conditions. In this work, several types of MnO2 and polymer cathode tantalum capacitors have been tested at highly accelerated conditions to assess voltage acceleration factors, determine adequate burn-in conditions, and assess the useful life. A modified time dependent dielectric breakdown (TDDB) model has been suggested to explain both types of failure, and a physical mechanism of degradation that is based on migration and reactions of oxygen vacancies explains increase of the defect related, IM failures with the level of stress.

tantalum capacitors↗

Mesoscale Modeling of the Effects of Accelerated Burnup on UO2 Microstructural Evolution

Accelerating the nuclear fuel qualification process will rely on some combination of advanced modeling and simulation techniques with accelerated irradiation testing and separate effects experiments to enable the development of new fuel concepts in a shorter time frame. One of the key challenges to successfully leveraging accelerated irradiation tests will be understanding the artifacts that may be introduced with accelerated accumulation of dose and/or burnup. This work presents phase field (MARMOT) simulations of the evolution of representative 2D UO2 microstructures up to 40 MWd/kgU. Simulations were performed under both commercial light water reactor fuel conditions as well as those that would be expected for highly accelerated (~10x) burnup conditions similar to those used in the MiniFuel irradiations in Oak Ridge National Laboratory’s High Flux Isotope Reactor. The phase field model was coupled with a discrete nucleation algorithm to model re- structuring at high burnup. The effect of the different fission rates in both microstructures was investigated at two temperatures: 650?C and 800?C. The lower temperature simulations both showed an onset of restructuring at nearly 60 MWd/kgU. More extensive restructuring was obtained in the MiniFuel microstructure compared with that of the PWR fuel. At 800?C, no restructuring was obtained as a result of the thermally activated diffusion of Xe atoms and U vacancies to fission gas bubbles, which reduces the nucleation driving force. These results highlight the importance of using modeling and simulation tools to inform the environmental conditions during targeted accelerated irradiation tests to extract the most useful fuel performance data.

accelerated fuel qualification, Phase Field, Restr↗

Ferrographic analysis of wear debris generated in accelerated rolling element fatigue tests

The types and quantities of wear particles generated during accelerated ball rolling contact fatigue tests were determined. Ball specimens were made of AMS 5749, a corrosion resistant, high-temperature bearing steel. The lubricant was a super-refined naphthenic mineral oil. Conditions included a maximum Hertz stress of 5.215 times 10 to the 9th power Pa and a shaft speed of 10,000 rpm. Four types of wear particles were observed; normal rubbing wear particles, fatigue spall particles, spheres, and friction polymer.

Jones, W. R., Jr.↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

The accelerated stress test results obtained on all terrestrial solar cells since the inception of the program are summarized. Tested cells were grouped according to the method used to form the conductive metallization layer: solder dipped, vacuum deposited, screen printed, and copper plated. Although metallization systems within each group were quite similar, they differed in numerous details according to the procedures employed by each manufacturer. Test results were summarized for all cells according to both electrical degradation and catastrophic mechanical changes. These results indicated a variability within each metallization category which was dependent on the manufacturer. Only one manufacturer was represented in the copper plated category and, although these showed no signs of detrimental copper diffusion during high temperature testing, their metallization was removed easily during high humidity pressure cooker testing. Preliminary testing of encapsulated cells showed no major differences between encapsulated and unencapsulated cells when subjected to accelerated testing.

Lathrop, J. W.↗

Statistical Modeling of Photovoltaic Reliability Using Accelerated Degradation Techniques (Poster)

We introduce a cutting-edge life-testing technique, accelerated degradation testing (ADT), for PV reliability testing. The ADT technique is a cost-effective and flexible reliability testing method with multiple (MADT) and Step-Stress (SSADT) variants. In an environment with limited resources, including equipment (chambers), test units, and testing time, these techniques can provide statisticallyrigorous prediction of lifetime and other interesting parameters, such as failure rate, warranty time, mean time to failure, degradation rate, activation energy, acceleration factor, and upper limit level of stress. J-V characterization can be used for degradation data and the generalized Eyring model can be used for the thermal-humidity stress condition. The SSADT model can be constructed basedon the cumulative damage model (CEM), which assumes that the remaining test united are failed according to cumulative density function of current stress level regardless of the history on previous stress levels.

14 SOLAR ENERGY↗

Results of the IEA Round Robin on Viscosity and Aging of Fast Pyrolysis Bio-oils: Long-Term Tests and Repeatability

An international round robin study of the viscosity and aging of fast pyrolysis bio-oil has been undertaken recently and this work is an outgrowth from that effort. Two bio-oil samples were distributed to the laboratories for aging tests and extended viscosity studies. The accelerated aging test was defined as the change in viscosity of a sealed sample of bio-oil held for 24 h at 80 °C. The test was repeated 10 times over consecutive days to determine the repeatability of the method. Other bio-oil samples were placed in storage at three temperatures, 21 °C, 4 °C and -17 °C for a period up to a year to evaluate the change in viscosity. The variation in the results of the aging test was shown to be low within a given laboratory. Storage of bio-oil under refrigeration can minimize the amount of change in viscosity. The accelerated aging test gives a measure of change similar to that of 6-12 months of storage at room temperature. These results can be helpful in setting standards for use of bio-oil, which is just coming into the marketplace.

aging↗