The Development of a Parameterized Scatter Removal Algorithm for NMIS Imaging

Neutron radiography is a powerful investigative technique for analyzing the interior structure of an object. If the true attenuation of neutrons at each position in the object can be measured, the cross-sections can be computed using the exponential attenuation formula. However, scattered neutrons will contribute to the measured neutron flux and reduce the measured attenuation. The Nuclear Materials Identification System (NMIS) uses a time-tagged and electronically collimated DT neutron source to reduce this effect; however, some of the scattering component remains. This work used Monte Carlo simulations to calculate the scattering component for a variety of scenarios. The scattering for each scenario was fit using a Gaussian distribution to derive a point scatter function. These point scatter functions were used to develop a parameterized scatter removal algorithm that can calculate and remove the scattering component for a wide range of scenarios based on operator inputs. The process used to calculate the scatter functions and develop the scatter removal algorithm is discussed in detail. Examples of simulated and experimental measurements are used to test and validate the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach

Purpose: A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values (''intensity''). Methods: A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specific intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and/or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. Results: The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5{+-}2.8) mm compared to (3.5{+-}3.0) mm with rigid registration. Conclusions: A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance.

60 APPLIED LIFE SCIENCES↗

Resilient Autonomous Wind Farms

With the advent of an increasing number of control strategies that seek to optimize wind turbine performance on a farm level, taking into account individual wind turbine information to achieve wind-farm-level objectives has become an increasingly important goal. Methods for controlling wind turbines on an individual and farm level have experienced significant development, and an abundance of new implementations for gathering and using data from turbines have created potential for novel control mechanisms that can further optimize the performance and delivery characteristics of a wind farm. A key element of making these wind farms more efficient is to develop reliable algorithms that use local sensor information that is already being collected, such as from local meteorological stations, nearby radars, sodars, and lidars, and supervisory control and data acquisition (SCADA) data. Making use of information from all wind turbines in a wind farm can enable such approaches as determining the atmospheric conditions across the farm, improving fault-finding, and ensuring more efficient overall control of farmwide optimizations through mechanisms such as wake steering. However, these approaches typically involve a centralized communications and control center. In order to ensure the resilient operation of the farm, it is necessary to develop an approach that distributes the calculation and communication amongst multiple nodes throughout the farm. In this fashion, a redundant, robust, and secure network can be created, which can tolerate faults in calculation, communication, and even external attacks that seek to disrupt the operation of the wind farm. This paper introduces the use of the Raft-Byzantine-Fault-Tolerant algorithm in the implementation of autonomous control of a wind farm. This implementation will allow for fault tolerance for malfunctioning nodes, sensors, transmitters, and connectors. This approach is equally extensible to account for malicious actors. It will...

fault tolerance↗

SU-E-T-106: Development of a Collision Prediction Algorithm for Determining Problematic Geometry for SBRT Treatments Using a Stereotactic Body Frame

Purpose: Collision between the gantry and the couch or patient during Radiotherapy is not a common concern for conventional RT (static fields or arc). With the increase in the application of stereotactic planning techniques to the body, collisions have become a greater concern. Non-coplanar beam geometry is desirable in stereotatic treatments in order to achieve sharp gradients and a high conformality. Non-coplanar geometry is less intuitive in the body and often requires an iterative process of planning and dry runs to guarantee deliverability. Methods: Purpose written software was developed in order to predict the likelihood of collision between the head of the gantry and the couch, patient or stereotatic body frame. Using the DICOM plan and structures set, exported by the treatment planning system, this software is able to predict the possibility of a collision. Given the plan's isocenter, treatment geometry and exterior contours, the software is able to determine if a particular beam/arc is clinically deliverable or if collision is imminent. Results: The software was tested on real world treatment plans with untreatable beam geometry. Both static non-coplanar and VMAT plans were tested. Of these, the collision prediction software could identify all as having potentially problematic geometry. Re-plans of the same cases were also tested and validated as deliverable. Conclusion: This software is capable of giving good initial indication of deliverability for treatment plans that utilize complex geometry (SBRT) or have lateral isocenters. This software is not intended to replace the standard pre-treatment QA dry run. The effectiveness is limited to those portions of the patient and immobilization devices that have been included in the simulation CT and contoured in the planning system. It will however aid the planner in reducing the iterations required to create complex treatment geometries necessary to achieve ideal conformality and organ sparing.

60 APPLIED LIFE SCIENCES↗

Nanoscale dislocation shear loops at static equilibrium and finite temperature

Atomistic simulations are used to determine the resolved shear stress necessary for equilibrium and the resulting geometry of nanoscale dislocation shear loops in Al. Dislocation loops with different sizes and shapes are created via superposition of elemental triangular dislocation displacement fields in the presence of an externally imposed shear stress. First, a bisection algorithm is developed to determine systematically the resolved shear stress necessary for equilibrium at 0 K. Here, this approach allows for the identification of dislocation core structure and a correlation between dislocation loop size, shape and the computed shear stress for equilibrium. It is found, in agreement with predictions made by Scattergood and Bacon, that the equilibrium shape of a dislocation loop becomes more circular with increasing loop size. Second, the bisection algorithm is extended to study the influence of temperature on the resolved shear stress necessary for stability. An approach is presented to compute the effective lattice friction stress, including temperature dependence, for dislocation loops in Al. The temperature dependence of the effective lattice friction stress can be reliably computed for dislocation loops larger than 16.2 nm. However, for dislocation loops smaller than this threshold, the effective lattice friction stress shows a dislocation loop size dependence caused by significant overlap of the stress fields on the interior of the dislocation loops. Combined, static and finite temperature atomistic simulations provide essential data to parameterize discrete dislocation dynamics simulations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The use of computed radiography plates to determine light and radiation field coincidence

Purpose: Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators.Methods: CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size.Results: Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm.Conclusions: A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid nested sampling algorithm for Bayesian model selection applied to inverse subsurface flow problems

A Hybrid Nested Sampling (HNS) algorithm is proposed for efficient Bayesian model calibration and prior model selection. The proposed algorithm combines, Nested Sampling (NS) algorithm, Hybrid Monte Carlo (HMC) sampling and gradient estimation using Stochastic Ensemble Method (SEM). NS is an efficient sampling algorithm that can be used for Bayesian calibration and estimating the Bayesian evidence for prior model selection. Nested sampling has the advantage of computational feasibility. Within the nested sampling algorithm, a constrained sampling step is performed. For this step, we utilize HMC to reduce the correlation between successive sampled states. HMC relies on the gradient of the logarithm of the posterior distribution, which we estimate using a stochastic ensemble method based on an ensemble of directional derivatives. SEM only requires forward model runs and the simulator is then used as a black box and no adjoint code is needed. The developed HNS algorithm is successfully applied for Bayesian calibration and prior model selection of several nonlinear subsurface flow problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupling the core analysis program DeCART to the fuel performance application BISON

The 3D neutron transport and core analysis program DeCART was coupled to the fuels performance application BISON to provide a higher fidelity tool for fuel performance simulation. This project is motivated by the desire to couple a high fidelity core analysis program (based on the method of characteristics) to a high fidelity fuel performance program, both of which can simulate 3D problems. DeCART provides sub-pin level resolution of the multigroup neutron flux, with resonance treatment, during burnup or a fast transient. BISON implicitly solves coupled thermomechanical equations for the fuel on a sub-millimeter level finite element mesh. A method was developed for mapping the fission rate density and fast neutron flux from DeCART to BISON. Multiple depletion cases were run with one-way data transfer from DeCART to BISON. The one-way data transfer of fission rate density is shown to agree with the fission rate density obtained from an internal Lassman-style model in BISON. One-way data transfer was also demonstrated in a 3D case in which azimuthal asymmetry was induced in the fission rate density profile of a fuel rod modeled in DeCART. Two-way data transfer was established by mapping the temperature distribution from BISON to DeCART. A Picard iterative algorithm was developed for the loose coupling with two-way data transfer. (authors)

97 MATHEMATICS AND COMPUTING↗

Advanced Reactors-Intermediate Heat Exchanger (IHX) Coupling: Theoretical Modeling and Experimental Validation

The overall goal of the research project was to model the behavior of the advanced reactorintermediate heat exchange system and to develop advanced control techniques for off-normal conditions. The specific objectives defined for the project were: 1. To develop the steady-state thermal hydraulic design of the intermediate heat exchanger (IHX); 2. To develop mathematical models to describe the advanced nuclear reactor-IHX-chemical process/power generation coupling during normal and off-normal operations, and to simulate models using multiphysics software; 3. To develop control strategies using genetic algorithm or neural network techniques and couple these techniques with the multiphysics software; 4. To validate the models experimentally The project objectives were accomplished by defining and executing four different tasks corresponding to these specific objectives. The first task involved selection of IHX candidates and developing steady state designs for those. The second task involved modeling of the transient and offnormal operation of the reactor-IHX system. The subsequent task dealt with the development of control strategies and involved algorithm development and simulation. The last task involved experimental validation of the thermal hydraulic performances of the two prototype heat exchangers designed and fabricated for the project at steady state and transient conditions to simulate the coupling of the reactor- IHX-process plant system. The experimental work utilized the two test facilities at The Ohio State University (OSU) including one existing High-Temperature Helium Test Facility (HTHF) and the newly developed high-temperature molten salt facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resilient Information Architecture Platform for the Smart Grid (RIAPS): A Novel Open-Source Platform for Microgrid Control

Microgrids are seen as an effective way to achieve reliable, resilient, and efficient operation of the power distribution system. Core functions of the microgrid control system are defined by the IEEE standard 2030.7; however, the algorithms that realize these functions are not standardized, and are a topic of research. Furthermore, the corresponding controller hardware, operating system, and communication system to implement these functions vary significantly from one implementation to the next. In this paper, we introduce an open-source platform, Resilient Information Architecture Platform for the Smart Grid (RIAPS), ideally suited for implementing and deploying distributed microgrid control algorithms. RIAPS provides a design-time tool suite for development and deployment of distributed microgrid control algorithms. With support from a number of run-time platform services, developed algorithms can be easily implemented and deployed into real microgrids. To demonstrate the unique features of RIAPS, we propose and implement a distributed microgrid secondary control algorithm capable of synchronized and proportional compensation of voltage unbalance using distributed generators. In conclusion, test results show the effectiveness of the proposed control and the salient features of the RIAPS platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of NEM-based Pin-by-Pin HCMFD Algorithm to 3-D Core Analysis

A pin-wise reactor analysis is expected to provide a more accurate solution than the conventional nodal methods. However, a pin-wise approach is still computationally very costly though the computational performances have been enormously improved for decades. To overcome such limitation of a pin-by-pin core analysis, the HCMFD (Hybrid Course-Mesh Finite Difference) algorithm has been recently introduced. By adopting the HCMFD algorithm, a parallel computing can be applied very effectively. In the HCMFD algorithm, an iterative local-global strategy is adopted with a combination of two CMFD acceleration methods for the pin-wise core analysis. The global eigenvalue problem is solved by one-node CMFD, while the local fixed-source problems are solved by two-node CMFD based on the NEM (nodal expansion method). In the HCMFD computational scheme, a parallel computing can effectively be applied since most of the computational efforts are consumed to solve the local problems, and they can be solved in parallel. Previously, only a 2-D HCMFD algorithm was developed and its numerical efficiency was evaluated. In this paper, a 3D HCMFD scheme is introduced and some 3-D problems were analyzed to verify its applicability to 3D pin-wise core analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adaptive reduction of constitutive model-form error using a posteriori error estimation techniques

In engineering practice, models are typically kept as simple as possible for ease of setup and use, computational efficiency, maintenance, and overall reduced complexity to achieve robustness. In solid mechanics, a simple and efficient constitutive model may be favored over one that is more predictive, but is difficult to parameterize, is computationally expensive, or is simply not available within a simulation tool. In order to quantify the modeling error due to the choice of a relatively simple and less predictive constitutive model, we adopt the use of a posteriori model-form error-estimation techniques. Based on local error indicators in the energy norm, an algorithm is developed for reducing the modeling error by spatially adapting the material parameters in the simpler constitutive model. The resulting material parameters are not material properties per se , but depend on the given boundary-value problem. As a first step to the more general nonlinear case, we focus here on linear elasticity in which the “complex” constitutive model is general anisotropic elasticity and the chosen simpler model is isotropic elasticity. As a result, the algorithm for adaptive error reduction is demonstrated using two examples: (1) A transversely-isotropic plate with hole subjected to tension, and (2) a transversely-isotropic tube with two side holes subjected to torsion.

42 ENGINEERING↗

Search for New Physics in a Final State with Same-Sign Dileptons, Jets, and Missing Transverse Energy at 7 TeV Center of Mass Energy

We report on a search for new physics in a final state with two same sign leptons, missing transverse energy, and significant hadronic activity at a center of mass energy $\sqrt{s}$ = 7 TeV. The data were collected with the CMS detector at the CERN LHC and correspond to an integrated luminosity of 0.98 $\mathrm{fb}^{-1}$. Data--driven methods are developed to estimate the dominant Standard Model backgrounds. No evidence for new physics is observed. The dominant background to the analysis comes from failures of lepton identification in Standard Model $t\bar{t}$ events. The $t\bar{t}$ production cross section in the dilepton final state is measured using 3.1 $\mathrm{fb}^{-1}$ of data. The cross section is measured to be 194 $\pm$ 72 (stat) $\pm$ 24 (syst) $\pm$ 21 (lumi) pb. An algorithm is developed that uses tracking information to improve the reconstruction of missing transverse energy. The reconstruction of missing transverse energy is commissioned using the first collisio ns recorded at 0.9, 2.36 and 7 TeV data. Events with abnormally large values of missing transverse energy are identified as arising from anomalous signals in the calorimeters. Tools are developed to identify and remove these anomalous signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-FG-202-01: A Fast Yet Sensitive EPID-Based Real-Time Treatment Verification System

Purpose: To create a real-time EPID-based treatment verification system which robustly detects treatment delivery and patient attenuation variations. Methods: Treatment plan DICOM files sent to the record-and-verify system are captured and utilized to predict EPID images for each planned control point using a modified GPU-based digitally reconstructed radiograph algorithm which accounts for the patient attenuation, source energy fluence, source size effects, and MLC attenuation. The DICOM and predicted images are utilized by our C++ treatment verification software which compares EPID acquired 1024×768 resolution frames acquired at ∼8.5hz from Varian Truebeam™ system. To maximize detection sensitivity, image comparisons determine (1) if radiation exists outside of the desired treatment field; (2) if radiation is lacking inside the treatment field; (3) if translations, rotations, and magnifications of the image are within tolerance. Acquisition was tested with known test fields and prior patient fields. Error detection was tested in real-time and utilizing images acquired during treatment with another system. Results: The computational time of the prediction algorithms, for a patient plan with 350 control points and 60×60×42cm^3 CT volume, is 2–3minutes on CPU and <27 seconds on GPU for 1024×768 images. The verification software requires a maximum of ∼9ms and ∼19ms for 512×384 and 1024×768 resolution images, respectively, to perform image analysis and dosimetric validations. Typical variations in geometric parameters between reference and the measured images are 0.32°for gantry rotation, 1.006 for scaling factor, and 0.67mm for translation. For excess out-of-field/missing in-field fluence, with masks extending 1mm (at isocenter) from the detected aperture edge, the average total in-field area missing EPID fluence was 1.5mm2 the out-of-field excess EPID fluence was 8mm^2, both below error tolerances. Conclusion: A real-time verification software, with EPID images prediction algorithm, was developed. The system is capable of performing verifications between frames acquisitions and identifying source(s) of any out-of-tolerance variations. This work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Multi deep learning-based stochastic microstructure reconstruction and high-fidelity micromechanics simulation of time-dependent ceramic matrix composite response

A multi deep learning-based framework is developed for efficient, automated microstructure reconstruction and generation of stochastic representative volume elements (SRVEs) with periodic boundary conditions (PBCs) for accurate modeling of ceramic matrix composite (CMC) response. The methodology comprises a convolutional neural network coupled with regression layers to act as a vanilla regression network for semantic segmentation of the microstructure, allowing accurate characterization of the phases and their distributions at the microscale. Scanning electron microscope and confocal microscope are used to obtain C/SiNC and SiC/SiNC CMCs micrographs for vanilla regression testing. Microstructure variability in terms of fiber volume fraction and porosity are quantified through the output regression layer, ensuring accurate representation of material variability in SRVE construction. Generative adversarial network (GAN) and its variants are designed to produce high-fidelity SRVE, spanning CMCs microstructure variability space. A circular padding algorithm is developed to generate SRVEs with PBCs during training of GANs. The accuracy of the generated SRVEs is established through micromechanics simulations, where an efficient formulation of the high-fidelity generalized methods of cells (HFGMC) approach is used to compute the effective mechanical properties. Furthermore, an iterative algorithm is implemented in the HFGMC solver to simulate time-dependent deformation of SiC/SiNC subjected to creep loading conditions.

36 MATERIALS SCIENCE↗

SU-E-T-250: New IMRT Sequencing Strategy: Towards Intra-Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT planning that during treatment makes the inclusion of external factors possible and by doing so accounts for intra-fraction anatomy changes. Given a real-time imaging modality that will provide the updated patient anatomy during delivery, this sequencer is able to take these changes into account during the calculation of subsequent segments. Methods: Pencil beams are generated for each beam angle of the treatment and a fluence optimization is performed. The pencil beams, together with the patient anatomy and the above optimal fluence form the input of our algorithm. During each iteration the following steps are performed: A fluence optimization is done and each beam's fluence is then split to discrete intensity levels. Deliverable segments are calculated for each one of these. Each segment's area multiplied by its intensity describes its efficiency. The most efficient segment among all beams is then chosen to deliver a part of the calculated fluence and the dose that will be delivered by this segment is calculated. This delivered dose is then subtracted from the remaining dose. This loop is repeated until 90% of the dose has been delivered and a final segment weight optimization is performed to reach full convergence. Results: This algorithm was tested in several prostate cases yielding results that meet all clinical constraints. Quality assurance was performed on Delta4 and film phantoms for one of these prostate cases and received clinical acceptance after passing both gamma analyses with the 3%/3mm criteria. Conclusion: A new sequencing algorithm was developed to facilitate the needs of intensity modulated treatment. The first results on static anatomy confirm that it can calculate clinical plans equivalent to those of the commercially available planning systems. We are now working towards 100% dose convergence which will allow us to handle anatomy deformations. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗