Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report Project: Low-Energy Photonuclear Studies at HIGS and Lund

This report summarizes a program of low-energy photonuclear studies at MAX-Lab in Lund (Sweden) and at the High Intensity Gamma Source (HIGS) at Duke University. A major emphasis has been on Compton scattering from deuterium in order to determine the electric and magnetic polarizabilities of the neutron. The studies at Lund utilized unpolarized photons at Egamma = 62-115 MeV to measure differential cross sections. The studies at HIGS utilized polarized and unpolarized photon beams (both linear and circular) at Egamma < 90 MeV. Polarization observables will be exploited to improve our understanding of the electric and magnetic polarizabilities, and in particular, double-polarization observables (using polarized targets) will be measured in the future to provide new information about the spin polarizabilities of the nucleon. The MAX-Lab experiments (using unpolarized photons) focused on an approved PAC proposal for Compton scattering on the deuteron aimed at making a precise determination of the electromagnetic polarizabilities of the neutron. At MAX-Lab we had three of the largest NaI detectors in the world, each capable of ~2% energy resolution. We have completed our measurements in two separate tagged photon energy ranges which overlap each other (62-97 MeV and 90-115 MeV) and the results of these experiments have been published. The photon beam at the High Intensity Gamma Source (HIGS) has several distinct advantages that make it unique: (1) ultra-high photon flux, ultimately reaching 100 MHz, (2) 100% linearly polarized photon beam, as well as circular polarization, (3) monoenergetic beam, with ~2% energy resolution, and (4) extremely low-background beam environment. Exploiting the high flux and polarization capabilities of the HIGS photon beam is central in the series of experiments being performed at this facility. Very little data exist on Compton scattering using polarized photons. We will exploit clear sensitivities in the polarization observables to the electric and magnetic polarizabilities of the nucleon, and we will ultimately extend these studies to the investigation of the spin polarizabilities. To accomplish these objectives, a liquid hydrogen/deuterium/helium cryotarget has been constructed at HIGS, and an array of NaI detectors has been commissioned for Compton studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent T980 Crystal Collimation Studies at the Tevatron Exploiting a Pixel Detector System and a Multi-Strip Crystal Array

With the shutdown of the Tevatron, the T-980 crystal collimation experiment at Fermilab has been successfully completed. Results of dedicated beam studies in May 2011 are described in this paper. For these studies, two multi-strip crystals were installed in the vertical goniometer and an O-shaped crystal installed in a horizontal goniometer. A two-plane CMS pixel detector was also installed in order to enhance the experiment with the capability to image the profile of crystal channeled or multiple volume reflected beam. The experiment successfully imaged channeled beam from a crystal for 980-GeV protons for the first time. This new enhanced hardware yielded impressive results. The performance and characterization of the crystals studied have been very reproducible over time and consistent with simulations.

43 PARTICLE ACCELERATORS↗

Search for photons above 10 19 eV with the surface detector of the Pierre Auger Observatory

We use the surface detector of the Pierre Auger Observatory to search for air showers initiated by photons with an energy above 10 19 eV. Photons in the zenith angle range from 30° to 60° can be identified in the overwhelming background of showers initiated by charged cosmic rays through the broader time structure of the signals induced in the water-Cherenkov detectors of the array and the steeper lateral distribution of shower particles reaching ground. Applying the search method to data collected between January 2004 and June 2020, upper limits at 95% CL are set to an E -2 diffuse flux of ultra-high energy photons above 10 19 eV, 2 × 10 19 eV and 4 × 10 19 eV amounting to 2.11 × 10 -3 , 3.12 × 10 -4 and 1.72 × 10 -4 km -2 sr -1 yr -1 , respectively. While the sensitivity of the present search around 2 × 10 19 eV approaches expectations of cosmogenic photon fluxes in the case of a pure-proton composition, it is one order of magnitude above those from more realistic mixed-composition models. The inferred limits have also implications for the search of super-heavy dark matter that are discussed and illustrated.

ultra high energy photons and neutrinos↗

New Millisecond Isomer Lifetime Measurements at LANSCE

New half-life measurements have been made of the millisecond isomers {sup 71m}Ge, {sup 114m2}I, {sup 208m}Bi, {sup 88m1}Y, {sup 88m2}Y, and {sup 75m}As populated in neutron-induced reactions. These measurements were made using the unique time structure of the LANSCE/WNR neutron source, by observing the γ-ray decays of the isomers during the time between the LANSCE proton macropulses. Two different LANSCE proton beam time structures were used. The GEANIE array of HPGe detectors was used to detect the γ-ray decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a 252Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LANL/LLNL Prompt Fission Neutron Spectrum Program at LANSCE and Approach to Uncertainties

New data on the prompt fission neutron spectra (PFNS) from neutron-induced fission with higher accuracies are needed to resolve discrepancies in the literature and to address gaps in the experimental data. The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the PFNS for fission of {sup 239}Pu induced by neutrons from 0.5 to 20 MeV with accuracies of 3–5% in the outgoing energy from 0.1 to 9 MeV and 15% from 9 to 12 MeV and to provide detailed experimental uncertainties. Neutrons from the WNR/LANSCE neutron source are being used to induce fission in a Parallel-Plate Avalanche Counter (PPAC). Two arrays of neutron detectors are used to cover the energy range of neutrons emitted promptly in the fission process. Challenges for the present experiment include background reduction, use of {sup 239}Pu in a PPAC, and understanding neutron detector response. Achieving the target accuracies requires the understanding of many systematic uncertainties. The status and plans for the future will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Majorana Demonstrator calibration system

The Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-ton 76 Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this study, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Majorana Ge-76 double-beta decay project

The MAJORANA Project is a research and development activity set up to establish the feasibility and cost of a doublebetadecay experiment comprising a one-ton array of Ge detectors fabricated from germanium enriched to about 86% in Ge-76.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectroscopy of odd-proton nuclei in the region of {sup 254}No

Two rotational bands have been found in the transfermium nuclei {sup 251}Md and {sup 255}Lr, the latter being the heaviest nucleus so far studied in-beam. Both are assigned to a [521]1/2{sup -} Nilsson state by comparison to theory. The experiments have been carried out in the Accelerator Laboratory of the University of Jyvaeskylae (JYFL), where the array of germanium detectors JUROGAM was used in conjunction with the recoil-seperator RITU and the focal-plane setup GREAT for gamma-spectroscopic studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Neutrinoless Double Beta Decay with the CUORE experiment

CUORE is a next generation experiment aimed at the detection of neutrinoless Double Beta Decay of the nuclide {sup 130}Te. The experiment, which will take place in the Gran Sasso National Laboratory (Italy), will look for this rare decay using the macrobolometric technique with a prospected array of 988 detectors. Each bolometer will be constituted by a 5x5x5 cm{sup 3} TeO{sub 2} crystal, for a total mass of about 200 kg of {sup 130}Te, and will be maintained at a temperature of 10 mK. CUORE will probe the effective mass of the neutrino with a sensitivity of a few tens of meV. If an excess of counts are observed above background at the 2.5 MeV corresponding to the Q-value of the decay, CUORE will answer several questions that are still open in the field of neutrino physics, such as the determination of the particle's Majorana nature and of the absolute mass scale. A prototype for CUORE in Gran Sasso, named CUORICINO, has just closed after five years proving its importance as a stand-alone experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Concept of a charged fusion product diagnostic for NSTX

The concept of a new diagnostic for NSTX to determine the time dependent charged fusion product emission profile using an array of semiconductor detectors is presented. The expected time resolution of 1-2 ms should make it possible to study the effect of magnetohydrodynamics and other plasma activities (toroidal Alfven eigenmodes (TAE), neoclassical tearing modes (NTM), edge localized modes (ELM), etc.) on the radial transport of neutral beam ions. First simulation results of deuterium-deuterium (DD) fusion proton yields for different detector arrangements and methods for inverting the simulated data to obtain the emission profile are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback control of major disruptions in International Thermonuclear Experimental Reactor

It is argued that major disruptions in ITER can be avoided by the feedback control of the causative MHD precursors. The sensors will be 2D-arrays of ECE detectors and the suppressors will be modulated ECH beams injected radially to produce non-thermal radial pressures to counter the radial dynamics of MHD modes. The appropriate amplitude and phase of this signal can stabilize the relevant MHD modes and prevent their evolution to a major disruption. For multimode MHD precursors, an optimal feedback scheme with a Kalman filter is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

The observation of neutrinoless double-beta decay would determine whether the neutrino is a Majorana particle and provide information on the absolute scale of neutrino mass. The MAJORANA Collaboration is constructing the DEMONSTRATOR, an array of germanium detectors, to search for neutrinoless double-beta decay of 76Ge. The DEMONSTRATOR will contain 40 kg of germanium; up to 30 kg will be enriched to 86% in 76Ge. The DEMONSTRATOR will be deployed deep underground in an ultra-low-background shielded environment. Operation of the DEMONSTRATOR aims to determine whether a future tonne-scale germanium experiment can achieve a background goal of one count per tonne-year in a 4-keV region of interest around the 76Ge neutrinoless double-beta decay Q-value of 2039 keV.

Schubert, Alexis G.↗

High performance ultraviolet photodetectors based on ZnO nanoflakes/PVK heterojunction

A high performance ultraviolet (UV) photodetector is receiving increasing attention due to its significant applications in fire warning, environmental monitoring, scientific research, astronomical observation, etc. The enhancement in performance of the UV photodetector has been impeded by lacking of a high-efficiency heterojunction in which UV photons can efficiently convert into charges. In this work, the high performance UV photodetectors have been realized by utilizing organic/inorganic heterojunctions based on a ZnO nanoflakes/poly (N-vinylcarbazole) hybrid. A transparent conducting polymer poly(3,4-ethylene-dioxythiophene):poly(styrenesulfonate)-coated quartz substrate is employed as the anode in replacement of the commonly ITO-coated glass in order to harvest shorter UV light. The devices show a lower dark current density, with a high responsivity (R) of 7.27 × 10{sup 3 }A/W and a specific detectivity (D*) of 6.20 × 10{sup 13} cm Hz{sup 1/2}/W{sup −1} at 2 V bias voltage in ambient environment (1.30 mW/cm{sup 2} at λ = 365 nm), resulting in the enhancements in R and D* by 49% and one order of magnitude, respectively. The study sheds light on developing high-performance, large scale-array, flexible UV detectors using the solution processable method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New compact and efficient local oscillator optic system for the KSTAR electron cyclotron emission imaging system

Electron cyclotron emission imaging (ECEI) diagnostic on Korean Superconducting Tokamak Advanced Research utilizes quasi-optical heterodyne-detection method to measure 2D (vertical and radial) T{sub e} fluctuations from two toroidally separated poloidal cross section of the plasma. A cylindrical lens local oscillator (LO) optics with optical path length (OPL) 2–2.5 m has been used in the current ECEI system to couple the LO source to the 24 vertically aligned array of ECE detectors. For efficient and compact LO optics employing the Powell lens is proposed so that the OPL of the LO source is significantly reduced from ∼2.0 m to 0.4 m with new optics. The coupling efficiency of the LO source is expected to be improved especially at the edge channels. Results from the optical simulation together with the laboratory test of the prototype optics will be discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background materials and fabrication techniques for cables and connectors in the Majorana Demonstrator

Here, the Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale 76 Ge-based search (the LEGEND collaboration). In the Demonstrator, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the Majorana Demonstrator, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements

74 ATOMIC AND MOLECULAR PHYSICS↗