At least 1,117 records · Page 62

Epigraph: A Vaccine Design Tool Applied to an HIV Therapeutic Vaccine and a Pan-Filovirus Vaccine

Epigraph is an efficient graph-based algorithm for designing vaccine antigens to optimize potential T-cell epitope (PTE) coverage. Functionally, epigraph vaccine antigens are similar to Mosaic vaccines, which have demonstrated effectiveness in preliminary HIV non-human primate studies. In contrast to the Mosaic algorithm, Epigraph is substantially faster, and in restricted cases, provides a mathematically optimal solution. Furthermore, epigraph has new features that enable enhanced vaccine design flexibility. These features include the ability to exclude rare epitopes from a design, to optimize population coverage based on inexact epitope matches, and to apply the code to both aligned and unaligned input sequences. Epigraph was developed to provide practical design solutions for two outstanding vaccine problems. The first of these is a personalized approach to a therapeutic T-cell HIV vaccine that would provide antigens with an excellent match to an individual’s infecting strain, intended to contain or clear a chronic infection. The second is a pan-filovirus vaccine, with the potential to protect against all known viruses in the Filoviradae family, including ebolaviruses. A web-based interface to run the Epigraph tool suite is available (http://www.hiv.lanl.gov/content/sequence/EPIGRAPH/epigraph.html).

60 APPLIED LIFE SCIENCES↗

Design and simulation of multilayer coatings for a multi-channel Wolter-like x-ray imager with large field of view and high resolution

X-ray diagnostics are key instruments for understanding the physics behind inertial confinement fusion experiments. We report on the multilayer design optimization for the Toroidal X-ray Imager (TXI), a hard x-rays microscope instrument designed by Commissariat à l’énergie atomique (CEA) and Laboratoire Charles Fabry (LCF) to be installed on the National Ignition Facility. TXI includes six channels designed for three different energy bands centered on 8.7, 13, and 17.5 keV. Each channel is made up of two toroidal mirrors arranged in a Wolter-like configuration. The required field of view is 800 × 400 µm2, and the resolution should be better than 5 µm. In addition, we seek to estimate the spatial distribution of the temperature, which requires no spectral overlap of the different energy bands and a good spectral homogeneity of the image produced. The development of the multilayer coatings was performed in a two-step method. First, the coatings were optimized to obtain proper energy bands. Then, an x-ray tracing code was used to calculate the integrated optical response of each channel and adjust the response of the mirror to fulfill the requirements. To fulfill all the specifications, we propose an original design using a combination of two aperiodic coatings, one with a narrow bandwidth and the other one with a larger bandwidth.

hard x-rays↗

TorbeamNN: machine learning-based steering of ECH mirrors on KSTAR

We have developed TorbeamNN: a machine learning surrogate model for the TORBEAM ray tracing code to predict electron cyclotron heating (ECH) and current drive locations in tokamak plasmas. TorbeamNN provides more than a 100 times speed-up compared to the highly optimized and simplified real-time implementation of TORBEAM without any reduction in accuracy compared to the offline, full fidelity TORBEAM code. The model was trained using KSTAR ECH mirror geometries and works for both O-mode and X-mode absorption. The TorbeamNN predictions have been validated both offline and real-time in experiment. TorbeamNN has been utilized to track an ECH absorption vertical position target in dynamic KSTAR plasmas as well as under varying toroidal mirror angles and with a minimal average tracking error of 0.5 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DECT-MULTRA: Dual-Energy CT Image Decomposition With Learned Mixed Material Models and Efficient Clustering

Dual-energy computed tomography (DECT) imaging plays an important role in advanced imaging applications due to its material decomposition capability. Image-domain decomposition operates directly on CT images using linear matrix inversion, but the decomposed material images can be severely degraded by noise and artifacts. This paper proposes a new method dubbed DECT-MULTRA for image-domain DECT material decomposition that combines conventional penalized weighted-least squares (PWLS) estimation with regularization based on a mixed union of learned transforms (MULTRA) model. Our proposed approach pre-learns a union of common-material sparsifying transforms from patches extracted from all the basis materials, and a union of cross-material sparsifying transforms from multi-material patches. The common-material transforms capture the common properties among different material images, while the cross-material transforms capture the cross-dependencies. The proposed PWLS formulation is optimized efficiently by alternating between an image update step and a sparse coding and clustering step, with both of these steps having closed-form solutions. The effectiveness of our method is validated with both XCAT phantom and clinical head data. The results demonstrate that our proposed method provides superior material image quality and decomposition accuracy compared to other competing methods.

47 OTHER INSTRUMENTATION↗

Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens

Purpose: MANTIS is a Monte Carlo code developed for the detailed simulation of columnar CsI scintillator screens in x-ray imaging systems. Validation of this code is needed to provide a reliable and valuable tool for system optimization and accurate reconstructions for a variety of x-ray applications. Whereas previous validation efforts have focused on matching of summary statistics, in this work the authors examine the complete point response function (PRF) of the detector system in addition to relative light output values. Methods: Relative light output values and high-resolution PRFs have been experimentally measured with a custom setup. A corresponding set of simulated light output values and PRFs have also been produced, where detailed knowledge of the experimental setup and CsI:Tl screen structures are accounted for in the simulations. Four different screens were investigated with different thicknesses, column tilt angles, and substrate types. A quantitative comparison between the experimental and simulated PRFs was performed for four different incidence angles (0 deg., 15 deg., 30 deg., and 45 deg.) and two different x-ray spectra (40 and 70 kVp). The figure of merit (FOM) used measures the normalized differences between the simulated and experimental data averaged over a region of interest. Results: Experimental relative light output values ranged from 1.456 to 1.650 and were in approximate agreement for aluminum substrates, but poor agreement for graphite substrates. The FOMs for all screen types, incidence angles, and energies ranged from 0.1929 to 0.4775. To put these FOMs in context, the same FOM was computed for 2D symmetric Gaussians fit to the same experimental data. These FOMs ranged from 0.2068 to 0.8029. Our analysis demonstrates that MANTIS reproduces experimental PRFs with higher accuracy than a symmetric 2D Gaussian fit to the experimental data in the majority of cases. Examination of the spatial distribution of differences between the PRFs shows that the main reason for errors between MANTIS and the experimental data is that MANTIS-generated PRFs are sharper than the experimental PRFs. Conclusions: The experimental validation of MANTIS performed in this study demonstrates that MANTIS is able to reliably predict experimental PRFs, especially for thinner screens, and can reproduce the highly asymmetric shape seen in the experimental data. As a result, optimizations and reconstructions carried out using MANTIS should yield results indicative of actual detector performance. Better characterization of screen properties is necessary to reconcile the simulated light output values with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development Status of PROTEUS-MOC

The PROTEUS-MOC solver is intended to resolve the outstanding computational challenges that the PROTEUS-SN is limited by and bridge the gap between PROTEUS-SN and existing homogenized structured grid solvers. The primary push behind all of this work is to carry out coupled thermal-mechanical, fluid dynamics, and neutronics physics problems. The PROTEUS-MOC development has taken advantage of the combined experience with PROTEUS-SN and DeCART with the goal of producing a tool which combines the best features of both tools. Taking the DeCART tool as the model, it merges a subgroup cross section interpolation technique with a 2D method of characteristics approach and a 1D SN formulation. DeCART has been specifically demonstrated to be accurate on PWR and VHTR problems, but it has displayed several issues with regard to accuracy on thin axial mesh sizes which are attributable to the 2D1D scheme it is built upon. There are also notable problems with performance and scalability all of which we hope to resolve in PROTEUS-MOC. PROTEUS-MOC is at its core, based upon the success achieved with MOCFE which demonstrated excellent parallelization with respect to angle and good parallelization with respect to space. More recent efforts have indicated parallelization with respect to energy is also feasible. The work completed yielded a novel methodology where the axial basis functions are treated separately from the radial ones, but the geometry is extruded. This eliminates the need to carry out and store 3D ray tracing data and simultaneously allows the coarse axial node sizes typical with DeCART. To rapidly build a prototype, a standard power iteration algorithm was constructed using an unpreconditioned GMRES solution algorithm for solving the flux vector in each fission source iteration. The new PROTEUS-MOC solver was deployed on two test problems: Takeda and a heterogeneous cylindrical heavy water system. The Takeda benchmark problem is a standard homogeneous test problem which was previously found to be too difficult for the 3D MOCFE code to solve. Using the PROTEUS-MOC we were able to show space-angle convergence although full convergence requires further improvements in performance. The second benchmark problem was constructed more for future work than this year, but the results generated are promising indicating that it will be very useful in highlighting the weaknesses and strengths of the PROTEUS-MOC tool. While we are far from a production tool, the results included in this report give us confidence that we are on the right path to constructing an interceding code between the plethora of structured grid homogenized assembly solvers and the supercomputer consuming PROTEUS-SN code. With time, the creation of a suitable preconditioner along with typical optimization should reduce the performance shortcomings that are observable today.

Marin-Lafleche, A.↗

Imaging of Phase Objects using Partially Coherent Illumination

Screening high-power laser optics for light intensifying phase objects that cause laserinduced damage on downstream optics is critical to sustaining laser operation. Identifying such flaws on large-apertures is quite challenging since they are relatively small and invisible to conventional inspection methods. A Linescan Phase Differential Imaging (LPDI) system was developed to rapidly identify these flaws on large-aperture optics within a single full-aperture dark-field image. We describe a two-step production phase object screening process consisting of LPDI mapping and image analysis, followed by high-resolution interferometry and propagation based evaluation of the downstream damage potential of identified flaws. An image simulation code capable of modeling the LPDI partially coherent illumination was used to optimize its phase object sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing: the PRIMA Project

The growing number of cores provided by today’s high-end computing systems present substantial challenges to application developers in their pursuit of parallel efficiency. To find the most effective optimization strategy, application developers need insight into the runtime behavior of their code. The University of Oregon (UO) and the Julich Supercomputing Centre of Forschungszentrum Julich (FZJ) developed the performance analysis tools TAU and Scalasca, respectively, which allow high-performance computing (HPC) users to collect and analyze relevant performance data – even at very large scales. TAU and Scalasca are considered among the most advanced parallel performance systems available, and are used extensively across HPC centers in the U.S., Germany, and around the world.

97 MATHEMATICS AND COMPUTING↗

Estimation of Confidence Intervals for Multiplication and Efficiency

Helium-3 tubes are used to detect thermal neutrons by charge collection using the {sup 3}He(n,p) reaction. By analyzing the time sequence of neutrons detected by these tubes, one can determine important features about the constitution of a measured object: Some materials such as Cf-252 emit several neutrons simultaneously, while others such as uranium and plutonium isotopes multiply the number of neutrons to form bursts. This translates into unmistakable signatures. To determine the type of materials measured, one compares the measured count distribution with the one generated by a theoretical fission chain model. When the neutron background is negligible, the theoretical count distributions can be completely characterized by a pair of parameters, the multiplication M and the detection efficiency {var_epsilon}. While the optimal pair of M and {var_epsilon} can be determined by existing codes such as BigFit, the uncertainty on these parameters has not yet been fully studied. The purpose of this work is to precisely compute the uncertainties on the parameters M and {var_epsilon}, given the uncertainties in the count distribution. By considering different lengths of time tagged data, we will determine how the uncertainties on M and {var_epsilon} vary with the different count distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ISiCLE: A Quantum Chemistry Pipeline for Establishing in Silico Collision Cross Section Libraries

High throughput, comprehensive, and confident identifications of metabolites and other chemicals in biological and envi-ronmental samples will revolutionize our understanding of the role of these intriguing and chemically diverse molecules in biological systems. Despite recent technological advances, a metabolomics study still results in the detection of a dispropor-tionate number of features than cannot be confidently assigned to a chemical structure. This inadequacy is driven by the sin-gle most significant limitation in metabolomics: the reliance on reference libraries constructed through the analysis of au-thentic reference chemicals and the limited commercial availability of these compounds. To this end, we have developed the in silico chemical library engine (ISiCLE), a high-performance computing-friendly cheminformatics workflow for generating chemical properties. In the instantiation described here, we predict probable three-dimensional molecular conformers (i.e. conformational isomers) using chemical identifiers as input, from which collision cross sections (CCS) are derived. The ap-proach employs state-of-the-art first-principles simulation, distinguished by use of molecular dynamics, quantum chemistry, and ion mobility calculations to generate predictions, all without training data. Importantly, optimization of ISiCLE includ-ed a refactoring of the popular MOBCAL code for trajectory-based mobility calculations, improving its computational effi-ciency by over two orders of magnitude. Calculated CCS values were validated against 1,983 experimental CCS values and compared to previously reported CCS calculation approaches. Average CCS calculation absolute error is 3.2% with standard deviation 3.1%. An online database is introduced for sharing both calculated and experimental CCS values (metabolom-ics.pnnl.gov), initially including a CCS library with over 0.8M entries. Finally, three successful applications of molecule characterization using calculated CCS are described, including the identification of an environmental degradation product, the separation of molecular isomers, and the decoding of complex blinded mixtures of exposure chemicals. This work represents a promising method to address the limitations of small molecule identification, and offers alternatives to standards-based chemical identification amenable to high-performance computation.

Colby, Sean M↗

Optimization of a coherent soft x-ray beamline for coherent scattering experiments at NSLS-II

The coherent soft x-ray and full polarization control (CSX) beamline at the National Synchrotron Light Source - II (NSLS-II) will deliver 1013 coherent photons per second in the energy range of 0.2-2 keV with a resolving power of 2000. The source, a dual elliptically polarizing undulator (EPU), and beamline optics should be optimized to deliver the highest possible coherent flux in a 10-30 {micro}m spot for use in coherent scattering experiments. Using the computer code Synchrotron Radiation Workshop (SRW), we simulate the photon source and focusing optics in order to investigate the conditions which provide the highest usable coherent intensity on the sample. In particular, we find that an intermediate phasing magnet is needed to correct for the relative phase between the two EPUs and that the optimum phase setting produces a spectrum in which the desired wavelength is slightly red-shifted thus requiring a larger aperture than originally anticipated. This setting is distinct from that which produces an on-axis spectrum similar to a single long undulator. Furthermore, partial coherence calculations, utilizing a multiple electron approach, indicate that a high degree of spatial coherence is still obtained at the sample location when such an aperture is used. The aperture size which maximizes the signal-to-noise ratio of a double-slit experiment is explored. This combination of high coherence and intensity is ideally suited for x-ray ptychography experiments which reconstruct the scattering density from micro-diffraction patterns. This technique is briefly reviewed and the effects on the image quality of proximity to the beamline focus are explored.

36 MATERIALS SCIENCE↗

Glprof: A Gprof inspired, Callgraph-oriented Per-Object Disseminating Memory Access Multi-Cache Profiler

Application analysis is facilitated through a number of program profiling tools. The tools vary in their complexity, ease of deployment, design, and profiling detail. Specifically, understand- ing, analyzing, and optimizing is of particular importance for scientific applications where minor changes in code paths and data-structure layout can have profound effects. Understanding how intricate data-structures are accessed and how a given memory system responds is a complex task. In this paper we describe a trace profiling tool, Glprof, specifically aimed to lessen the burden of the programmer to pin-point heavily involved data-structures during an application's run-time, and understand data-structure run-time usage. Moreover, we showcase the tool's modularity using additional cache simulation components. We elaborate on the tool's design, and features. Finally we demonstrate the application of our tool in the context of Spec bench- marks using the Glprof profiler and two concurrently running cache simulators, PPC440 and AMD Interlagos.

Janjusic, Tommy↗

Numerical parameter optimizations of the Ignition and Growth model for a HMX plastic bonded explosive

We present here a novel method for optimizing parameters of the Ignition and Growth (I&G) reactive flow model for high explosives. The I&G model predicts the shock initiation response of explosives subjected to dynamic loading. However, calibrating the model is a time-consuming process because it has several parameters, typically requires multiple data sets, and there are no direct correlations between parameters and data. In this study, we couple a scalable optimization algorithm to simulations of shock initiation experiments in the multi-physics code ALE3D. We develop four I&G model parameter sets for the HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazocane)-based explosive LX-07 [90 wt. % HMX, 10 wt. % Viton A] based on minimizing the difference between calculations and measurements at the embedded pressure gauges in 1D gun shock experiments. Our study shows that a cost function based on both shock time of arrival and pressure pulse shape demonstrates the best agreement with experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

optimas v0.1

optimas is a Python library that can coordinate a large number of numerical simulations on high-performance computing resources, with the aim of optimizing a given simulation result. More specifically, this library is currently used for design optimization of laser-plasma particle accelerators. In this context, the performance of particle accelerator designs are often evaluated with large-scale simulation codes, and many separate simulations need to be run - with different design parameters - in order to find the most performant design. optimas facilitates this process by providing a convenient interface to advanced optimizers (e.g. Bayesian optimization), and by coordinating the execution of the different simulations on HPC resources. (This is done by leveraging the library libensemble.) Compared to other open-source optimization libraries (e.g. Ax), optimas is more tailored towards execution on DOE HPC resources (e.g. Perlmutter, Summit, etc.) and is specialized for the type of simulation codes and workflows that are used in the community of laser-plasma acceleration.

Lehe, Remi↗

HiPACE++: A portable, 3D quasi-static particle-in-cell code

Modeling plasma accelerators is a computationally challenging task and the quasi-static particle-in-cell algorithm is a method of choice in a wide range of situations. In this work, we present the first performance-portable, quasi-static, three-dimensional particle-in-cell code HiPACE++. By decomposing all the computation of a 3D domain in successive 2D transverse operations and choosing appropriate memory management, HiPACE++ demonstrates orders-of-magnitude speedups on modern scientific GPUs over CPU-only implementations. The 2D transverse operations are performed on a single GPU, avoiding time-consuming communications. The longitudinal parallelization is done through temporal domain decomposition, enabling near-optimal strong scaling from 1 to 512 GPUs. HiPACE++ is a modular, open-source code enabling efficient modeling of plasma accelerators from laptops to state-of-the-art supercomputers.

97 MATHEMATICS AND COMPUTING↗

Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.