Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Dosimetric Impact of Interplay Effect on RapidArc Lung Stereotactic Treatment Delivery

Purpose: Volumetric modulated arc therapy (RapidArc; Varian Medical Systems, Palo Alto, CA) allows fast delivery of stereotactic radiotherapy for Stage I lung tumors. We investigated discrepancies between the calculated and delivered dose distributions, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion. Methods and Materials: In 20 consecutive patients with Stage I lung cancer who completed RapidArc delivery, 15 had tumor motion exceeding 5 mm on four-dimensional computed tomography scan. Static and dynamic measurements were performed with Gafchromic EBT film (International Specialty Products Inc., Wayne, NJ) in a Quasar motion phantom (Modus Medical Devices, London, Ontario, Canada). Static measurements were compared with calculated dose distributions, and dynamic measurements were compared with the convolution of static measurements with sinusoidal motion patterns. Besides clinical treatment plans, additional cases were optimized to create excessive multileaf collimator modulation and delivered on the phantom with peak-to-peak motions of up to 25 mm. {gamma} Analysis with a 3% dose difference and 2- or 1-mm distance to agreement was used to evaluate the accuracy of delivery and the dosimetric impact of the interplay effect. Results: In static mode film dosimetry of the two-arc delivery in the phantom showed that, on average, fewer than 3% of measurements had {gamma} greater than 1. Dynamic measurements of clinical plans showed a high degree of agreement with the convolutions: for double-arc plans, 99.5% met the {gamma} criterion. The degree of agreement was 98.5% for the plans with excessive multileaf collimator modulations and 25 mm of motion. Conclusions: Film dosimetry shows that RapidArc accurately delivers the calculated dose distribution and that interplay between leaves and tumor motion is not significant for single-fraction treatments when RapidArc is delivered with two different arcs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap

High-resolution real-time particle mass measurements have not been achievable because the enormous amount of kinetic energy imparted to the particles upon expansion into vacuum competes with and overwhelms the forces applied to the charged particles within the mass spectrometer. It is possible to reduce the kinetic energy of a collimated particulate ion beam through collisions with a buffer gas while radially constraining their motion using a quadrupole guide or trap over a limited mass range. Controlling the pressure drop of the final expansion into a quadrupole trap permits a much broader mass range at the cost of sacrificing collimation. To achieve high-resolution mass analysis of massive particulate ions, an efficient trap with a large tolerance for radial divergence of the injected ions was developed that permits trapping a large range of ions for on-demand injection into an awaiting mass analyzer. The design specifications required that frequency of the trapping potential be adjustable to cover a large mass range and the trap radius be increased to increase the tolerance to divergent ion injection. The large-radius linear quadrupole ion trap was demonstrated by trapping singly-charged bovine serum albumin ions for on-demand injection into a mass analyzer. Additionally, this work demonstrates the ability to measure an electrophoretic mobility cross section (or ion mobility) of singly-charged intact proteins in the low-pressure regime. This work represents a large step toward the goal of high-resolution analysis of intact proteins, RNA, DNA, and viruses.

59 BASIC BIOLOGICAL SCIENCES↗

200 MeV proton irradiation of the oxide-dispersion-strengthened copper alloy (GlidCop-Al15)

In search to identify extremely stable materials to perform the collimation function of the 7-TeV proton beam halo at the Large Hadron Collider (LHC), oxide dispersion strengthened (DS) copper alloys were explored. These internally oxidized copper alloys known as GlidCop are also leading candidates for high heat flux applications in fusion reactors and as divertor and first wall structure in ITER. These considerations have led to an extensive body of research on neutron-induced changes in the microstructure and physio-mechanical properties. This study focused primarily on the damage induced by 200 MeV protons on as wrought and cold-worked GlidCop Al15 DS copper ally selected as a candidate material of the LHC beam collimation structure to damage levels up to ~10 displacements-per-atom (dpa) and irradiation temperatures up to ~600 °C. For reference, low dose spallation neutron damage at sub-zero irradiation temperature was included in the study. Proton irradiation effects on dimensional stability, mechanical behavior, electrical resistivity and X-ray diffraction-based microstructural changes are presented in the paper. GlidCop Al15 exhibited excellent thermal stability and superior to pure Cu resistance to conductivity loss. Proton irradiation-induced hardening and embrittlement at distinct irradiation temperature regimes were shown to follow similar trends to what was reported under neutron exposure to even higher dpa damage. At T irr ~600 ± 20 °C the cold-worked DS copper alloy exhibited softening accompanied by elongation reduction while at T irr ~200 ± 10 °C the as-wrought experienced hardening with elongation increase. Furthermore, high resolution X-ray diffraction revealed that even low-dose neutron irradiation has a strong influence on the size and distribution of dispersed Al 2 O 3 particles.

36 MATERIALS SCIENCE↗

Proton irradiation effects in Molybdenum-Carbide-Graphite composites

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) has prompted the investigation of novel materials for beam-intercepting devices, and in particular for the collimators responsible for protecting the machine from beam losses. The HL-LHC collimation system will inevitably experience increased levels of radiation damage and undergo changes in their crucial physio-mechanical properties. Graphite-matrix composite materials containing molybdenum carbide particles, along with small amounts of titanium carbide, were developed with the objective of enhanced in-beam performance and tested under proton irradiation. The physical degradation observed in early grades of molybdenum carbide compounds, even after modest proton fluences, has prompted the development of advanced compounds. In this work, we examine the effects of proton irradiation on the microstructural and thermophysical properties of new grades of Molybdenum-carbide-graphite compounds up to fluences of ~2 × 10 20 p/cm 2 . Here, we employ a combination of precision dilatometry and high-energy X-ray diffraction to quantify the dimensional stability and crystallographic phase evolution both pre- and post-irradiation. Our results reveal that these new compounds exhibit superior resilience to radiation damage than their predecessors.

36 MATERIALS SCIENCE↗

Effects of Packaging SrI2(Eu) Scintillator Crystals

Recent renewed emphasis placed on gamma-ray detectors for national security purposes has motivated 13 researchers to identify and develop new scintillator materials capable of high energy resolution and 14 growable to large sizes. We have discovered that SrI2(Eu) has many desirable properties for gamma-ray 15 detection and spectroscopy, including high light yield of ~90,000 photons/MeV and excellent light yield 16 proportionality. Furthermore, we have demonstrated growth of crack-free 2 diameter boules. We 17 have measured <2.7% FWHM at 662 keV with small detectors (<1 cm3) in direct contact with a 18 photomultiplier tube, and ~3% resolution at 662 keV is obtained for 1 in3 crystals. Due to the 19 hygroscopic nature of SrI2(Eu), proper packaging is required for field use. This work describes a 20 systematic study performed to determine the key factors in the packaging process to optimize 21 performance. These factors include proper polishing of the surface, the geometry of the crystal, 22 reflector materials and windows. A technique based on use of a collimated Cs-137 source was developed 23 to examine light collection uniformity. Employing this technique, we found that when the crystal is 24 packaged properly, the variance in the pulse height at 662 keV from events near the bottom of the 25 crystal compared to those near the top of the crystal could be reduced to <1%. This paper describes the 26 design and engineering of our detector package in order to improve energy resolution of 1 in3-scale 27 SrI2(Eu) crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

The X-ray counterpart to the gravitational-wave event GW170817

We present a long-standing paradigm in astrophysics is that collisions—or mergers—of two neutron stars form highly relativistic and collimated outflows (jets) that power γ-ray bursts of short (less than two seconds) duration. The observational support for this model, however, is only indirect. A hitherto outstanding prediction is that gravitational-wave events from such mergers should be associated with γ-ray bursts, and that a majority of these bursts should be seen off-axis, that is, they should point away from Earth. Here we report the discovery observations of the X-ray counterpart associated with the gravitational-wave event GW170817. Although the electromagnetic counterpart at optical and infrared frequencies is dominated by the radioactive glow (known as a ‘kilonova’) from freshly synthesized rapid neutron capture (r-process) material in the merger ejecta, observations at X-ray and, later, radio frequencies are consistent with a short γ-ray burst viewed off-axis. Lastly, our detection of X-ray emission at a location coincident with the kilonova transient provides the missing observational link between short γ-ray bursts and gravitational waves from neutron-star mergers, and gives independent confirmation of the collimated nature of the γ-ray-burst emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Gate-tunable Veselago interference in a bipolar graphene microcavity

The relativistic charge carriers in monolayer graphene can be manipulated in manners akin to conventional optics. Klein tunneling and Veselago lensing have been previously demonstrated in ballistic graphene pn-junction devices, but collimation and focusing efficiency remains relatively low, preventing realization of advanced quantum devices and controlled quantum interference. Here, we present a graphene microcavity defined by carefully-engineered local strain and electrostatic fields. Electrons are manipulated to form an interference path inside the cavity at zero magnetic field via consecutive Veselago refractions. The observation of unique Veselago interference peaks via transport measurement and their magnetic field dependence agrees with the theoretical expectation. We further utilize Veselago interference to demonstrate localization of uncollimated electrons and thus improvement in collimation efficiency. Our work sheds new light on relativistic single-particle physics and provide a new device concept toward next-generation quantum devices based on manipulation of ballistic electron trajectory.

36 MATERIALS SCIENCE↗

Low-divergence femtosecond X-ray pulses from a passive plasma lens

Electron and X-ray beams originating from compact laser-wakefield accelerators have very small source sizes that are typically on the micrometre scale. Therefore, the beam divergences are relatively high, which makes it difficult to preserve their high quality during transport to applications. To improve on this, tremendous efforts have been invested in controlling the divergence of the electron beams, but no mechanism for generating collimated X-ray beams has yet been demonstrated experimentally. Here we propose and realize a scheme where electron bunches undergoing focusing in a dense, passive plasma lens can emit X-ray pulses with divergences approaching the incoherent limit. Furthermore, compared with conventional betatron emission, the divergence of this so-called plasma lens radiation is reduced by more than an order of magnitude in solid angle, while maintaining a similar number of emitted photons per electron. This X-ray source offers the possibility of producing brilliant and collimated few-femtosecond X-ray pulses for ultra-fast science, in particular for studies based on X-ray diffraction and absorption spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress and prospects for an FI relevant point design

The physics issues involved in scaling from sub ignition to high gain fast ignition are discussed. Successful point designs must collimate the electrons and minimize the stand off distance to avoid multi mega-joule ignition energies. Collimating B field configurations are identified and some initial designs are explored.

42 ENGINEERING↗

Neutron Radiographic Inspection of Industrial Components using Kamini Neutron Source Facility

Kamini (Kalpakkam Mini) reactor is a U{sup 233} fuelled, demineralised light water moderated and cooled, beryllium oxide reflected, low power (30 kW) nuclear research reactor. This reactor functions as a neutron source with a flux of 10{sup 12} n/cm{sup 2} s{sup -1} at core centre with facilitates for carrying out neutron radiography, neutron activation analysis and neutron shielding experiments. There are two beam tubes for neutron radiography. The length/diameter ratio of the collimators is about 160 and the aperture size is 220 mmx70 mm. Flux at the outer end of the beam tube is {approx}10{sup 6}-10{sup 7} n/cm{sup 2} s. The north end beam tube is for radiography of inactive object while the south side beam tube is for radiography of radioactive objects. The availability of high neutron flux coupled with good collimated beam provides high quality radiographs with short exposure time. The reactor being a unique national facility for neutron radiography has been utilized in the examination of irradiated components, aero engine turbine blades, riveted plates, automobile chain links and for various types of pyro devices used in the space programme. In this paper, an overview of the salient features of this reactor facility for neutron radiography and our experience in the inspection of a variety of industrial components will be given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Compact, Multiangle Electron Spectrometer for Ultraintense Laser-Plasma Interaction Experiments

Experiments on the multiterawatt (MTW) laser at the Laboratory for Laser Energetics will study the effect of the focal-spot shape on the forward acceleration and collimation of electrons. A compact electron spectrometer has been developed to record the energy spectra of electrons ejected in the interaction of the laser at multiple angular locations simultaneously. The modular system with replaceable magnets provides an adjustable energy band, currently 0.2-6 MeV. The detector is an array of imaging plates. The device is designed to operate in the high-noise environment (bremsstrahlung and Compton x rays, gamma rays, and scattered electrons), while being compact enough to fit in the 30 cm radius MTW target chamber. The detector geometry and shielding were optimized with the particle/radiation transport code GEANT4. Calibration was performed with beta sources. The required dynamic range, sensitivity, and resolution were confirmed with initial MTW experimental data.

Gotchev, O V↗

Planar nanowire arrays formed by atomic-terrace low-angle shadowing

A relatively simple method for preparation of planar nanowire arrays on vicinal substrates by molecular beam epitaxy is presented. The atomic step-and-terrace morphology of vicinal substrates is used to produce a shadowing effect on a highly collimated molecular beam at an oblique incidence to the substrate. The collimation is achieved by placing the evaporation source at a large working distance (40-100 cm) from the substrate. The method's capabilities have been demonstrated by preparation of arrays of Ag and Au nanowires on vicinal Si(111) and {alpha}-Al{sub 2}O{sub 3} (0001) substrates. Nanowires with a width of down to 10-15 nm and a thickness of 1.5 nm have been readily achieved.

36 MATERIALS SCIENCE↗

Relativistic hydrodynamic simulation of jet deceleration in GRB

Using the novel adaptive mesh refinement code, AMRVAC, we investigate the interaction between collimated ejecta (jetlike fireball models with various opening angle) with its surrounding cold Interstellar Medium (ISM). This is relevant for Gamma Ray Bursts, and we demonstrate that, thanks to the AMR strategy, we resolve the internal structure of the shocked shell-ISM matter. We determine the deceleration from an initial Lorentz factor {gamma} = 100 up to the almost Newtonian {gamma}{approx}O(3) phase of the flow. We discuss the effect of varying the opening angle on the deceleration, and pay attention to differences with their 1D isotropic GRB equivalents. These are due to thermally induced sideways expansions of both shocked shell and shocked ISM regions. The propagating 2D ultrarelativistic shell does not accrete all the surrounding medium located within its initial opening angle. The difference with isotropic GRB models is quite pronounced for shells with small opening angle. In the most collimated ejecta (open angle of 1 deg.), the deceleration phase (once the reverse shock has traversed the shell structure) shows distinct modulation, attributed to repeated rarefactions traversing the shell. These may have a clear impact on the emitted afterglow radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Astrophysical Jets with Conical Wire Arrays: Radiative Cooling, Rotation and Deflection

Highly collimated outflows or jets are produced by a number of astrophysical objects including protostars. The morphology and collimation of these jets is thought to be strongly influenced by the effects of radiative cooling, angular momentum and the interstellar medium surrounding the jet. Astrophysically relevant experiments are performed with conical wire array z-pinches investigating each of these effects. It is possible in each case to enter the appropriate parameter regime, leading the way towards future experiments where these different techniques can be more fully combined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Dosimetry for Radiobiology Experiments Using 25 MeV LINAC

The next generation of radiobiology research requires increasingly more complex radiation sources to address questions ranging from the effects of space-based radiation to the influence of dose rate on biological systems. The Idaho Accelerator Center (IAC) has developed a radiobiology research facility to address some of these questions. The irradiation challenge is to deliver stable and reproducible conditions of high dose rate with well-controlled beam uniformity, dose, and dose rate under controlled temperature. In this work, we used a 25 MeV modified medical grade linear accelerator (LINAC) to obtain a high and adjustable electron dose rate. To overcome electron beam drift we used a collimator that both assisted the LINAC operator to steer the beam and ensured that regardless of beam drift, only the fixed collimated beam would irradiate the specimens. In addition, we utilized a beam flattener to keep the beam variation as low as 3% at 2.5 cm from the beam's center, and 1% variation between the simultaneously irradiated sample tubes. We also demonstrated that a segmented Faraday 'cup'(FC) array provides a useful real-time beam scanning and monitoring system, and is promising for implementing real-time dosimetry and control.

43 PARTICLE ACCELERATORS↗

Doppler Broadening Analysis of Steel Specimens Using Accelerator Based In Situ Pair Production

Positron Annihilation Spectroscopy (PAS) techniques can be utilized as a sensitive probe of defects in materials. Studying these microscopic defects is very important for a number of industries in order to predict material failure or structural integrity. We have been developing gamma-induced pair-production techniques to produce positrons in thick samples ({approx}4-40 g/cm{sup 2}, or {approx}0.5-5 cm in steel). These techniques are called 'Accelerator-based Gamma-induced Positron Annihilation Spectroscopy'(AG-PAS). We have begun testing the capabilities of this technique for imaging of defect densities in thick structural materials. As a first step, a linear accelerator (LINAC) was employed to produce photon beams by stopping 15 MeV electrons in a 1 mm thick tungsten converter. The accelerator is capable of operating with 30-60 ns pulse width, up to 200 mA peak current at 1 kHz repetition rate. The highly collimated bremsstrahlung beam impinged upon our steel tensile specimens, after traveling through a 1.2 m thick concrete wall. Annihilation radiation was detected by a well-shielded and collimated high-purity germanium detector (HPGe). Conventional Doppler broadening spectrometry (DBS) was performed to determine S, W and T parameters for our samples.

36 MATERIALS SCIENCE↗