Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Growth from Solutions: Kink dynamics, Stoichiometry, Face Kinetics and stability in turbulent flow

1. Kink dynamics. The first segment of a polygomized dislocation spiral step measured by AFM demonstrates up to 60% scattering in the critical length l*- the length when the segment starts to propagate. On orthorhombic lysozyme, this length is shorter than that the observed interkink distance. Step energy from the critical segment length based on the Gibbs-Thomson law (GTL), l* = 20(omega)alpha/(Delta)mu is several times larger than the energy from 2D nucleation rate. Here o is tine building block specific voiume, a is the step riser specific free energy, Delta(mu) is the crystallization driving force. These new data support our earlier assumption that the classical Frenkel, Burton -Cabrera-Frank concept of the abundant kink supply by fluctuations is not applicable for strongly polygonized steps. Step rate measurements on brushite confirms that statement. This is the1D nucleation of kinks that control step propagation. The GTL is valid only if l* <Dk/vk, the diffusion path of a kink that has diffusivity Dk and average growth velocity vk. This is equivalent to supersaturations sigma less than approx. alpha/2l*, where alpha is the building block size. For lysozyme, sigma much less than (1%). Conventionally used interstep distance generated by screw dislocation, 19(omega)alpha/Delta(mu) should be replaced by the very different real one, approx.4l*. 2. Stoichiometry. Kink, and thus step and face rates of a non-Kossel complex molecular monocomponent or any binary, AB, lattice was found theoretically to be proportional to 1/(zeta(sup 1/2) + zeta(sup - 1/2)), where zeta = [B]/[A] is the stoichiometry ratio in solution. The velocities reach maxima at zeta = 1. AFM studies of step rates on CaOxalate monohydrate (kidney stones) from aqueous solution was found to obey the law mentioned above. Generalization for more complex lattice will be discussed. 3. Turbulence. In agreement with theory, high precision in-situ laser interferometry of the (101) KDP crystal face shows step bunching if solution flows parallel to the step flow. The bunch height increases with the distance the bunch travels, i.e. with the face size. However, when the flow rate, u, increases, at u greater than approx. 1 m / s , the average step bunch height decreases as 1/u. The pheonomenon is attributed to the turbulent rather than laminar viscous boundary layer where diffusivity Dt = 0.5u(sub tau),y, i.e. increases linearly with the distance y from the solid face. Friction velocity, u(sub tau) approx. u(sup 7/8). Dramatically larger rate of the mass/heat transport within the turbulent, as compared to the laminar, viscous layer will be discussed.

Chernov, A. A.↗

Radiation damage in cubic ZrO 2 and yttria-stabilized zirconia from molecular dynamics simulations

Here, we perform molecular dynamics simulation on cubic ZrO 2 and yttria-stabilized zirconia (YSZ) to elucidate defect cluster formation resulting from radiation damage, and evaluate the impact of Y-dopants. Interstitial clusters composed of split-interstitial building blocks, i.e., Zr-Zr or Y-Zr are formed. Moreover, oxygen vacancies control cation defect migration; in their presence, Zr interstitials aggregate to form split-interstitials whereas in their absence Zr interstitials remain immobile, as isolated single-interstitials. Y-doping prevents interstitial cluster formation due to sequestration of oxygen vacancies.

36 MATERIALS SCIENCE↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear flexure and torsion of rotating beams, with application to helicopter rotor blades. I - Formulation. II - Response and stability results

The dynamic response and aeroelastic stability of rotating beams such as helicopter blades is investigated analytically. The Hamilton principle is used to formulate the equations of motion for extensional and inextensional beams with precone angles and variable pitch angles, taking higher-order nonlinearities into account. The derivation of the equations and their approximate solution by a Galerkin procedure are explained in detail, and numerical results of equilibrium solutions and stability analyses are presented graphically.

Crespo Da Silva, M. R. M.↗

Power system observability and dynamic state estimation for stability monitoring using synchrophasor measurements

Growing penetration of intermittent resources such as renewable generations increases the risk of instability in a power grid. This paper introduces the concept of observability and its computational algorithms for a power grid monitored by the wide-area measurement system (WAMS) based on synchrophasors, e.g. phasor measurement units (PMUs). The goal is to estimate real-time states of generators, especially for potentially unstable trajectories, the information that is critical for the detection of rotor angle instability of the grid. The paper studies the number and siting of synchrophasors in a power grid so that the state of the system can be accurately estimated in the presence of instability. An unscented Kalman filter (UKF) is adopted as a tool to estimate the dynamic states that are not directly measured by synchrophasors. The theory and its computational algorithms are illustrated in detail by using a 9-bus 3-generator power system model and then tested on a 140-bus 48-generator Northeast Power Coordinating Council power grid model. Case studies on those two systems demonstrate the performance of the proposed approach using a limited number of synchrophasors for dynamic state estimation for stability assessment and its robustness against moderate inaccuracies in model parameters.

Observability, Dynamic state estimation, Synchroph↗

Simultaneous stabilization and simultaneous pole placement by nonswitching dynamic compensation

The 'simultaneous stabilization problem' is defined and theorems are proposed for its solution. The problem consists in answering the question: given an r-tuple G sub 1(s), G sub r(s) of p x m proper transfer functions, does there exist a compensator K(s) such that the closed loop systems G sub 1(s) (I+K(s)G sub 1(s)) (-1), G sub r(s) (I+K(s) G sub r(s)) (-1) are (internally) stable. This question arises in reliability theory, where G sub 2(s), G sub r(s) represents a plant G sub 1(s) operating in various modes of failure and K(s) is a nonswitching stabilizing compensator. It is important in the stability analysis and design of a plant which can be switched into various operating modes. The simultaneous stabilization problem can also apply to the stabilization of a nonlinear system which is linearized at several equilibria. Conditions are defined for pole placement and the generalized Sylvestor matrix is discussed.

Ghosh, B. K.↗

Signal Processing Methods for Liquid Rocket Engine Combustion Stability Assessments

The J2X Gas Generator engine design specifications include dynamic, spontaneous, and broadband combustion stability requirements. These requirements are verified empirically based high frequency chamber pressure measurements and analyses. Dynamic stability is determined with the dynamic pressure response due to an artificial perturbation of the combustion chamber pressure (bomb testing), and spontaneous and broadband stability are determined from the dynamic pressure responses during steady operation starting at specified power levels. J2X Workhorse Gas Generator testing included bomb tests with multiple hardware configurations and operating conditions, including a configuration used explicitly for engine verification test series. This work covers signal processing techniques developed at Marshall Space Flight Center (MSFC) to help assess engine design stability requirements. Dynamic stability assessments were performed following both the CPIA 655 guidelines and a MSFC in-house developed statistical-based approach. The statistical approach was developed to better verify when the dynamic pressure amplitudes corresponding to a particular frequency returned back to pre-bomb characteristics. This was accomplished by first determining the statistical characteristics of the pre-bomb dynamic levels. The pre-bomb statistical characterization provided 95% coverage bounds; these bounds were used as a quantitative measure to determine when the post-bomb signal returned to pre-bomb conditions. The time for post-bomb levels to acceptably return to pre-bomb levels was compared to the dominant frequency-dependent time recommended by CPIA 655. Results for multiple test configurations, including stable and unstable configurations, were reviewed. Spontaneous stability was assessed using two processes: 1) characterization of the ratio of the peak response amplitudes to the excited chamber acoustic mode amplitudes and 2) characterization of the variability of the peak response's frequency over the test duration. This characterization process assists in evaluating the discreteness of a signal as well as the stability of the chamber response. Broadband stability was assessed using a running root-mean-square evaluation. These techniques were also employed, in a comparative analysis, on available Fastrac data, and these results are presented here.

Kenny, R. Jeremy↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fully Coupled Aeroelastic Stability Analysis of Adaptive Shape Memory Alloy Structural Technologies for Airframe Noise Reduction

The objective of this work is the development of computational models and analysis of the coupled fluid-structure response of a slat gap filler (SGF) noise treatment applied to the leading-edge-slat component of a high-lift system typical of modern transport aircraft. The representative airframe chosen for this work is NASA’s High-lift Common Research Model (CRM-HL) in a baseline high-lift configuration. Superelastic shape memory alloys (SMAs) have been identified as enabling materials for these structural treatments. Since the technology elements rely upon having a highly reconfigurable structure, designs must be assessed for static aeroelastic deflection as well as dynamic aeroelastic stability using coupled computational fluid dynamics (CFD) and nonlinear computational structural dynamics (NL CSD) tools. The technical approach consists of solving for the flow field around the entire vehicle using a global CFD model, followed by extraction of relevant local subdomain data for CFD and NL-CSD co-simulations. The SGF design is assessed using both 2D and 3D co-simulations to predict quasi-static aeroelastic deformations and to assess dynamic aeroelastic stability.

Fluid structure interaction↗

Effect of rotation on plasma stability in the gas-dynamic trap

The effects of the centrifugal force and finite Larmor radius on plasma stability in the gas-dynamic trap are considered. Estimates show that the stability is governed by the strong effect of the finite Larmor radius of fast particles. If this stabilizing mechanism does not operate, then the instability ceases to be exponential when the sheared plasma rotation becomes sufficiently intense. In this case, the potential perturbation amplitude increases according to a power law, and the instability threshold remains unchanged. These effects do not influence the stability of the first azimuthal perturbation mode in a plasma with a free boundary. But when the plasma is in good electrical contact with the conducting wall of the device and when the plasma density profile is not too peaked at the axis, the first mode is stabilized by the finite Larmor radius effect because of the radial variation of the perturbed electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous stabilization and simultaneous pole-placement by nonswitching dynamic compensation

The 'simultaneous stabilization problem' is defined and theorems are proposed for its solution. The problem consists in answering the question: given an r-tuple G sub 1(s), G sub r(s) of p x m proper transfer functions, does there exist a compensator K(s) such that the closed loop systems G sub 1(s) (I+K(s)G sub 1(s)) (-1), G sub r(s) (I+K(s) G sub r(s)) (-1) are (internally) stable. This question arises in reliability theory, where G sub 2(s), G sub r(s) represents a plant G sub 1(s) operating in various modes of failure and K(s) is a nonswitching stabilizing compensator. It is important in the stability analysis and design of a plant which can be switched into various operating modes. The simultaneous stabilization problem can also apply to the stabilization of a nonlinear system which is linearized at several equilibria. Conditions are defined for pole placement and the generalized Sylvestor matrix is discussed. Previously announced in STAR as N82-31031

Ghosh, B. K.↗