Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

LibERI—A portable and performant multi-GPU accelerated library for electron repulsion integrals via OpenMP offloading and standard language parallelism

A portable and performant graphics processing unit (GPU)-accelerated library for electron repulsion integral (ERI) evaluation, named LibERI, has been developed and implemented via directive-based (e.g., OpenMP and OpenACC) and standard language parallelism (e.g., Fortran DO CONCURRENT). Offloaded ERIs consist of integrals over low and high contraction s, p, and d functions using the rotated-axis and Rys quadrature methods. GPU codes are factorized based on previous developments with two layers of integral screening and quartet presorting. In this work, the density screening is moved to the GPU to enhance the computational efficacy for large molecular systems. Here, the L-shells in the Pople basis set are also separated into pure S and P shells to increase the ERI homogeneity and reduce atomic operations and the memory footprint. LibERI is compatible with any quantum chemistry drivers supporting the MolSSI Driver Interface. Benchmark calculations of LibERI interfaced with the GAMESS software package were carried out on various GPU architectures and molecular systems. The results show that the LibERI performance is comparable to other state-of-the-art GPU-accelerated codes (e.g., TeraChem and GMSHPC) and, in some cases, outperforms conventionally developed ERI CUDA kernels (e.g., QUICK) while fully maintaining portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature analysis of optical coupling using AlGaAs/GaAs LEDs for high-density integrated power modules

A low-temperature co-fired ceramic (LTCC)-based optocoupler design is demonstrated as a possible solution for optical isolation in high-density integrated power modules. The design and fabrication of LTCC based package are discussed. Commercially available aluminum gallium arsenide/gallium arsenide (AlGaAs/GaAs) double heterostructure is used both as emitter and photodetector in the proposed optocoupler. A detailed study on the electroluminescence and spectral response of the AlGaAs/GaAs structure is conducted at elevated temperatures. The material figure of merit parameter, D*, is calculated in the temperature range 77–800 K. The fabricated optocoupler is tested at elevated temperatures, and the results are presented.

42 ENGINEERING↗

Compilation of LLNL CUP-2 Data

The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results indicate that the CUP-2 standard has a natural isotopic ratio, and does not appear to have been isotopically enriched or depleted in any way, and was not contaminated by a source of uranium with a non-natural isotopic composition. Furthermore, the lack of 233 U and 236 U above the instrumental detection limit indicates that this sample was not exposed to a neutron flux, which would have generated one or both of these isotopes in measurable concentrations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

CASM Monte Carlo: Calculations of the thermodynamic and kinetic properties of complex multicomponent crystals

Monte Carlo techniques play a central role in statistical mechanics approaches that connect macroscopic thermodynamic and kinetic properties to the electronic structure of a material. This paper describes the implementation of Monte Carlo techniques for the study of multicomponent crystalline materials within the Clusters Approach to Statistical Mechanics (CASM) software suite, and demonstrates their use in model systems to calculate free energies and kinetic coefficients, study phase transitions, and construct phase diagrams from first principles. Many crystal structures are complex, with multiple sublattices occupied by differing sets of chemical species, along with the presence of vacancies or interstitial species. This imposes constraints on concentration variables, the form of thermodynamic potentials, and the values of kinetic transport coefficients. The framework used by CASM to formulate thermodynamic potentials and kinetic transport coefficients accounting for arbitrarily complex crystal structures is presented and demonstrated with examples of increasing complexity. Additionally, an overview of the capabilities of the CASM software specific to Monte Carlo methods is given, and a new CASM software package is introduced, casm-flow, which helps automate the setup, submission, management, and analysis of Monte Carlo simulations.

Cluster expansion↗

Plasma sputtering robotic device for in-situ thick coatings of long, small diameter vacuum tubes

A novel robotic plasma magnetron mole with a 50 cm long cathode was designed, fabricated, and operated. The reason for this endeavor is to alleviate the problems of unacceptable resistive heating of stainless steel vacuum tubes in the BNL Relativistic Heavy Ion Collider (RHIC). The magnetron mole was successfully operated to copper coat an assembly containing a full-size, stainless steel, cold bore, RHIC magnet tubing connected to two types of RHIC bellows, to which two additional pipes made of RHIC tubing were connected. To increase the cathode lifetime, a movable magnet package was developed, and the thickest possible cathode was made, with a rather challenging target to substrate (de facto anode) distance of less than 1.5 cm. Achieving reliable steady state magnetron discharges at such a short cathode to anode gap was rather challenging, when compared to commercial coating equipment, where the target to substrate distance is 10's cm; 6.3 cm is the lowest experimental target to substrate distance found in the literature. Additionally, the magnetron developed during this project provides unique omni-directional uniform coating. The magnetron is mounted on a carriage with spring loaded wheels that successfully crossed bellows and adjusted for variations in vacuum tube diameter, while keeping the magnetron centered. Electrical power and cooling water were fed through a cable bundle. The umbilical cabling system is driven by a motorized spool. Excellent coating adhesion was achieved. Measurements indicated that well-scrubbed copper coating reduced secondary electron yield to 1, i.e., the problem of electron clouds can be eliminated. Room temperature RF resistivity measurement indicated that a 10 μm copper coated stainless steel RHIC tube has a conductivity close to that of pure copper tubing. Excellent coating adhesion was achieved. The device details and experimental results are described.

36 MATERIALS SCIENCE↗

Short-range stabilizing potential for computing energies and lifetimes of temporary anions with extrapolation methods

The energy of a temporary anion can be computed by adding a stabilizing potential to the molecular Hamiltonian, increasing the stabilization until the temporary state is turned into a bound state, and then further increasing the stabilization until enough bound state energies have been collected so that these can be extrapolated back to vanishing stabilization. The lifetime can be obtained from the same data, but only if the extrapolation is done through analytic continuation of the momentum as a function of the square root of a shifted stabilizing parameter. This method is known as analytic continuation of the coupling constant, and it requires—at least in principle—that the bound-state input data are computed with a short-range stabilizing potential. In the context of molecules and ab initio packages, long-range Coulomb stabilizing potentials are, however, far more convenient and have been used in the past with some success, although the error introduced by the long-rang nature of the stabilizing potential remains unknown. Here, we introduce a soft-Voronoi box potential that can serve as a short-range stabilizing potential. The difference between a Coulomb and the new stabilization is analyzed in detail for a one-dimensional model system as well as for the {sup 2}Π{sub u} resonance of CO{sub 2}{sup −}, and in both cases, the extrapolation results are compared to independently computed resonance parameters, from complex scaling for the model, and from complex absorbing potential calculations for CO{sub 2}{sup −}. It is important to emphasize that for both the model and for CO{sub 2}{sup −}, all three sets of results have, respectively, been obtained with the same electronic structure method and basis set so that the theoretical description of the continuum can be directly compared. The new soft-Voronoi-box-based extrapolation is then used to study the influence of the size of diffuse and the valence basis sets on the computed resonance parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A numerical study of geometry dependent errors in velocity, temperature, and density measurements from single grid planar retarding potential analyzers

Planar retarding potential analyzers (RPAs) have been utilized numerous times on high profile missions such as the Communications/Navigation Outage Forecast System and the Defense Meteorological Satellite Program to measure plasma composition, temperature, density, and the velocity component perpendicular to the plane of the instrument aperture. These instruments use biased grids to approximate ideal biased planes. These grids introduce perturbations in the electric potential distribution inside the instrument and when unaccounted for cause errors in the measured plasma parameters. Traditionally, the grids utilized in RPAs have been made of fine wires woven into a mesh. Previous studies on the errors caused by grids in RPAs have approximated woven grids with a truly flat grid. Using a commercial ion optics software package, errors in inferred parameters caused by both woven and flat grids are examined. A flat grid geometry shows the smallest temperature and density errors, while the double thick flat grid displays minimal errors for velocities over the temperature and velocity range used. Wire thickness along the dominant flow direction is found to be a critical design parameter in regard to errors in all three inferred plasma parameters. The results shown for each case provide valuable design guidelines for future RPA development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DeePKS-kit: A package for developing machine learning-based chemically accurate energy and density functional models

We introduce DeePKS-kit, an open-source software package for developing machine learning based energy and density functional models. DeePKS-kit is interfaced with PyTorch, an open-source machine learning library, and PySCF, an ab initio computational chemistry program that provides simple and customized tools for developing quantum chemistry codes. It supports the DeePHF and DeePKS methods. In addition to explaining the details in the methodology and the software, we also provide an example of developing a chemically accurate model for water clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Noise-Aware Classical Optimizer for Variational Quantum Algorithms

A key component of variational quantum algorithms (VQAs) is the choice of classical optimizer employed to update the parameterization of an ansatz. It is well recognized that quantum algorithms will, for the foreseeable future, necessarily be run on noisy devices with limited fidelities. Thus, the evaluation of an objective function (e.g., the guiding function in the quantum approximate optimization algorithm (QAOA) or the expectation of the electronic Hamiltonian in variational quantum eigensolver (VQE)) required by a classical optimizer is subject not only to stochastic error from estimating an expected value but also to error resulting from intermittent hardware noise. Model-based derivative-free optimization methods have emerged as popular choices of a classical optimizer in the noisy VQA setting, based on empirical studies. However, these optimization methods were not explicitly designed with the consideration of noise. In this work we adapt recent developments from the “noise-aware numerical optimization” literature to these commonly used derivative-free model-based methods. We introduce the key defining characteristics of these novel noise-aware derivative-free model-based methods that separate them from standard model-based methods. In conclusion, we study an implementation of such noise-aware derivative-free model-based methods and compare its performance on demonstrative VQA simulations to classical solvers packaged in scikit-quant.

classical optimizers↗

Correlation between inter-spin interaction and molecular dynamics of organic radicals in organic 1D nanochannels

One-dimensional (1D) molecular chains of 4-substituted-2,2,6,6-tetramethyl-1-piperidinyloxyl (4-X-TEMPO) radicals were constructed in the crystalline 1D nanochannels of 2,4,6-tris(4-chlorophenoxy)-1,3,5-triazine (CLPOT) used as a template. The ESR spectra of CLPOT inclusion compounds (ICs) using 4-X-TEMPO were examined on the basis of spectral simulation using EasySpin program package for simulating and fitting ESR spectra. The ESR spectra of [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC were isotropic in the total range of temperatures. The peak-to-peak line width (ΔB{sub pp}) became monotonically narrower from 2.8 to 1.3 mT with increase in temperature in the range of 4.2–298 K. The effect of the rotational diffusion motion of TEMPO radicals in the CLPOT nanochannels for the inter-spin interaction of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC was found to be smaller than the case of [(TPP){sub 2}−(TEMPO){sub 1.0}] IC (TPP = tris(o-phenylenedioxy)cyclotriphosphazene) reported in our previous study. The ΔB{sub pp} of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC in the whole range of temperatures was much narrower than the estimation to be based on the Van Vleck’s formula for the second moment of the rigid lattice model where the electron spin can be considered as fixed; 11 mT of Gaussian line-width component. This suggests the possibility of exchange narrowing in the 1D organic-radical chains of the [(CLPOT){sub 2}-(TEMPO){sub 1.0}] IC. On the other hand, the ESR spectra of [(CLPOT){sub 2}-(MeO-TEMPO){sub 0.41}] IC (MeO-TEMPO = 4-methoxy-TEMPO) were reproduced by a superposition of major broad isotropic adsorption line and minor temperature-dependent modulated triplet component. This suggests that the IC has the part of 1D organic-radical chains and MeO-TEMPO molecules isolated in the CLPOT nanochannels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure prediction of epitaxial inorganic interfaces by lattice and surface matching with Ogre

We present a new version of the Ogre open source Python package with the capability to perform structure prediction of epitaxial inorganic interfaces by lattice and surface matching. In the lattice matching step, a scan over combinations of substrate and film Miller indices is performed to identify the domain-matched interfaces with the lowest mismatch. Subsequently, surface matching is conducted by Bayesian optimization to find the optimal interfacial distance and in-plane registry between the substrate and the film. For the objective function, a geometric score function is proposed based on the overlap and empty space between atomic spheres at the interface. The score function reproduces the results of density functional theory (DFT) at a fraction of the computational cost. The optimized interfaces are pre-ranked using a score function based on the similarity of the atomic environment at the interface to the bulk environment. Final ranking of the top candidate structures is performed with DFT. Ogre streamlines DFT calculations of interface energies and electronic properties by automating the construction of interface models. The application of Ogre is demonstrated for two interfaces of interest for quantum computing and spintronics, Al/InAs and Fe/InSb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic and embodied energy analysis of integrated circuit manufacturing processes

Integrated circuits (ICs) are the fundamental microelectronic building blocks of typical information and communication technology (ICT) devices such as laptops and smartphone. With the emergence of faster and cheaper low-power ICs for the growing ICT market, there is a limited information on their manufacturing energy and economic impacts owing to the lack of recurrent upgradation of proprietary IC manufacturing process data. In this work, economic and life cycle energy assessments (LCAs) of IC manufacturing and assembly processes were conducted using the latest bill of materials (BOM) manufacturing data in a state-of-the-art IC manufacturing cost software tool developed by IC Knowledge, LLC. IC manufacturing cost was estimated to be $\$$1.00-$\$$5.00/cm 2 ; the high-end cost represents the most advanced 3D NAND IC technology with the Wafer Level Chip Scale Package cost of $4/cm 2 . Total cumulative energy demand (CED) estimates of IC manufacturing using the OpenLCA software ranged from 9 to 38 MJ/cm 2 or 56–235 BJ/month with the largest share (~ 75%) from on-site energy. The IC manufacturing CED is projected to increase with the progress in IC technology node, which has increased by more than two times for technology node evolution from 110 to 14 nm. Furthermore, the representative detailed BOM data were considered to reduce the CED uncertainties of the estimated standard deviation of 35%- 42%.

97 MATHEMATICS AND COMPUTING↗

NWChem: a Comprehensive and Scalable Open-Source Solution for Large Scale Molecular Simulations

The NWChem computational chemistry package offers extensive capabilities for large scale simulations of chemical and biological systems. Utilizing a common computational framework, diverse theoretical descriptions can be used to provide the best solution for a given scientific problem. Scalable parallel implementations and modular software design enables efficient utilization of current computational architectures. This paper provides an overview of NWChem focusing primarily on the core theoretical descriptions provided by the code and their parallel performance. In addition, future plans are outlined.

99 GENERAL AND MISCELLANEOUS↗

Formulation and numerical analysis of a fully-coupled dynamically deforming electromagnetic wire

Here, an electromagnetic beam model is developed for the simulation of actuated electronic textiles. The beam is solved using a nonlinear director-based kinematic description with additional temperature and electric potential fields along its length. The three fields are fully coupled by mutual dependences on the deformation, Lorenz force, back electromotive force, temperature dependent constitutive responses, and the Seebeck effect. Instead of solving Maxwell's equations in full detail, a quasistatic approximation is used to solve the electric potential in the presence of a moving material medium. The current-carrying beam approximation is used to further simplify the solution space for the potential. While this formulation alleviates the spatial and temporal discretization restrictions, the coupled problem is an index-1 semi-explicit Differential Algebraic Equation requiring special treatment. The time dependent problem is solved using different Runge-Kutta methods. Diagonally implicit Runge-Kutta methods and explicit Runge-Kutta methods using implicit solution of the electric potential problem are explored. The finite element model is implemented using the open source package FEniCS, which is able to automatically generate the linearizations of the multiphysics equations required for the implicit solutions. A model problem is constructed with which to test and analyze the physical formulation and numerical solution techniques. The time stepping methods are verified using the convergence orders of the higher-order Runge-Kutta methods. Runtime comparisons show that the explicit methods are generally more computationally efficient than the implicit schemes used for this problem. For the implicit schemes, a staggered solution is significantly faster than a monolithic solution at most time step sizes. However, at very large time steps, such as those that would be used for dynamic relaxation, the monolithic solution can be more efficient than the staggered solution.

36 MATERIALS SCIENCE↗

Supersonic Gas Injector for Plasma Fueling in the National Spherical Torus Experiment

A supersonic gas injector (SGI) has been developed for fueling and diagnostic applications on the National Spherical Torus Experiment (NSTX). It is comprised of a graphite converging-diverging Laval nozzle and a commercial piezoelectric gas valve mounted on a movable probe at a low-field-side midplane port location. Also mounted on the probe is a diagnostic package: a Langmuir probe, two thermocouples, and five pick-up coils for measuring toroidal, radial, vertical magnetic field components and magnetic fluctuations at the location of the SGI tip. The SGI flow rate is up to 33.25 Pa m 3 / (1.75 × 10 22 euterium particles/s), comparable to conventional NSTX gas injectors. The nozzle operates in a pulsed regime at room temperature and a reservoir gas pressure up to 665 kPa (5000 Torr). The deuterium jet Mach number of about 4 and the divergence half-angle of 5 to 25 deg have been measured in laboratory experiments simulating the NSTX environment. Reliable operation of the SGI and all mounted diagnostics at distances 0.01 to 0.20 m from the plasma separatrix has been demonstrated in NSTX experiments. The SGI has been used for fueling of ohmic and 2- to 4-MW neutral beam injection–heated L- and H-mode plasmas. Fueling efficiency in the range 0.1 to 0.3 has been obtained from the plasma electron inventory analysis. In conclusion, the SGI-fueling–based plasma discharge scenarios enabling better density control have been developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗