Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Electric currents in flare ribbons: Observations and three-dimensional standard model

We present for the first time the evolution of the photospheric electric currents during an eruptive X-class flare, accurately predicted by the standard three-dimensional (3D) flare model. We analyze this evolution for the 2011 February 15 flare using Helioseismic and Magnetic Imager/Solar Dynamics Observatory magnetic observations and find that localized currents in J-shaped ribbons increase to double their pre-flare intensity. Our 3D flare model, developed with the OHM code, suggests that these current ribbons, which develop at the location of extreme ultraviolet brightenings seen with Atmospheric Imaging Assembly imagery, are driven by the collapse of the flare's coronal current layer. These findings of increased currents restricted in localized ribbons are consistent with the overall free energy decrease during a flare, and the shapes of these ribbons also give an indication of how twisted the erupting flux rope is. Finally, this study further enhances the close correspondence obtained between the theoretical predictions of the standard 3D model and flare observations, indicating that the main key physical elements are incorporated in the model.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment-theory comparison for low frequency BAE modes in the strongly shaped H-1NF stellarator

Here, recent advances in the modeling, analysis, and measurement of fluctuations have significantly improved the diagnosis and understanding of Alfvén eigenmodes in the strongly shaped H-1NF helical axis stellarator. Experimental measurements, including 3D tomographic inversions of high resolution visible light images, are in close agreement with beta-induced Alfvén eigenmodes (BAEs) calculated using the compressible ideal MHD code, CAS3D. This is despite the low β in H-1NF, providing experimental evidence that these modes can exist due to compression that is induced by the strong shaping in stellarators, in addition to high β, as is the case in tokamaks. This is confirmed using the CONTI and CAS3D codes, which show significant gap structures at lower frequencies which contain BAE and beta-acoustic Alfvén eigenmodes (BAAEs). The BAEs are excited in the absence of a well confined energetic particle source, further confirming previous studies that thermal particles, electrons, or even radiation fluctuations can drive these modes. Datamining of magnetic probe data shows the experimentally measured frequency of these modes has a clear dependence on the rotational transform profile, which is consistent with a frequency dependency due to postulated confinement related temperature variations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

DeepLensSBI: Deep inference of simulated strong lenses in ground-based surveys

This code is used to train and test machine learning models and generate results and plots presented in 2501.08524 [astro-ph.IM]. The code is written in python. The goal of this work is to train ML models trained on simulated images of strong gravitational lenses. The trained model can then quickly infer properties of the lensed objects with uncertainty quantification.

Poh, Jason [Univ. of Chicago, IL (United States)] ↗

GRinding Automated Classification Engine

This work is an ML-driven framework for automated surface analysis of microscopy images. We create a training dataset by imaging stainless steel samples to benchmark four developed deep neural network architectures. These models, based on a YOLOv8n-cls backend, integrate image features and process metadata using various fusion methods to distinguish between acceptable and unacceptable surface finishes. This code is associated with publication "Classifying Alloy Surface Preparation Quality with Metadata-Infused Machine Learning for Rapid Alloy Discovery" for project APEX LDRD-ER (25-ERD-039)

Gongora, AldairE [Lawrence Livermore National Labo↗

Science Campaign-1 Pulsed Power Efforts [Slides]

The PHELIX portable pulsed-power driver is discussed. It is composed of two air-insulated, single Marx modules capable of storing 300 kJ of electrical energy. The Marx are cable coupled to a toroidal transformer with a 4:1 winding ratio. The experimental load is located at the center of the transformer. The components are mounted in a 8’x10’x18’ boxcar which can be moved in and out of the beam line at the LANL proton radiography facility and prevents EMI within the facility. PHELIX has successfully completed two liner implosion experiments with full diagnostic return from flash X-ray imaging, optical Faraday load current, and multi-channel PDV. Computational modeling with both the legacy 1D MHD code RAVEN and the LANL ASC-LAP FLAG code show good agreement with data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Technology Research and Development (NTRD) Technical Monthly February FY18

[LANL] Energy-resolved neutron imaging data on transmutation fuels (Figure 1A) containing Am and Np were reanalyzed. The analysis using the SAMMY code was focused on retrieving absolute densities for five isotopes, 238U, 239Pu, 240Pu, 241Am and 237Np. The bulk composition described by partial densities of the main isotopes 237Np, 239Pu, 240Pu, and 242Am, resultant from the initial analysis agreed to better than 0.1 g/cc with the partial densities determined by mass spectrometry, except for 238U, which was overestimated by the initial approach. It was found that due to only a single resonance of 238U present in the fitted energy range of 1eV to 9eV (Figure 1 B), the refined areal densities for 238U were statistically insignificant, resulting in large errors. Consequently, the fitted energy range was extended to 24eV to include a second 238U resonance (Figure 1C, D), which stabilized the 238U areal densities, providing excellent agreement for all five isotopes. (A. Losko and S. Vogel)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CALIBRATED ULTRA FAST IMAGE SIMULATIONS FOR THE DARK ENERGY SURVEY

Image simulations are becoming increasingly important in understanding the measurement process of the shapes of galaxies for weak lensing and the associated systematic effects. For this purpose we present the first implementation of the Monte Carlo Control Loops (MCCL), a coherent framework for studying systematic effects in weak lensing. It allows us to model and calibrate the shear measurement process using image simulations from the Ultra Fast Image Generator (UFig) and the image analysis software SExtractor. We apply this framework to a subset of the data taken during the Science Verification period (SV) of the Dark Energy Survey (DES). We calibrate the UFig simulations to be statistically consistent with one of the SV images, which covers ∼0.5 square degrees. We then perform tolerance analyses by perturbing six simulation parameters and study their impact on the shear measurement at the one-point level. This allows us to determine the relative importance of different parameters. For spatially constant systematic errors and point-spread function, the calibration of the simulation reaches the weak lensing precision needed for the DES SV survey area. Furthermore, we find a sensitivity of the shear measurement to the intrinsic ellipticity distribution, and an interplay between the magnitude-size and the pixel value diagnostics in constraining the noise model. This work is the first application of the MCCL framework to data and shows how it can be used to methodically study the impact of systematics on the cosmic shear measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

The molecular baryon cycle of M82

Baryons cycle into galaxies from the intergalactic medium and are converted into stars; a fraction of the baryons are ejected out of galaxies by stellar feedback. Here we present new high-resolution (3.″9; 68 pc) {sup 12}CO(2–1) and {sup 12}CO(3–2) images that probe these three stages of the baryon cycle in the nearby starburst M82. We combine these new observations with previous {sup 12}CO(1–0) and [Fe ii] images to study the physical conditions within the molecular gas. Using a Bayesian analysis and the radiative transfer code RADEX, we model temperatures and densities of molecular hydrogen, as well as column densities of CO. Besides the disk, we concentrate on two regions within the galaxy: an expanding super-bubble and the base of a molecular streamer. Shock diagnostics, kinematics, and optical extinction suggest that the streamer is an inflowing filament, with a mass inflow rate of molecular gas of 3.5 M{sub ⊙} yr{sup −1}. We measure the mass outflow rate of molecular gas of the expanding super-bubble to be 17 M{sub ⊙} yr{sup −1}, five times higher than the inferred inflow rate and 1.3 times the star formation rate of the galaxy. The high mass outflow rate and large star formation rate will deplete the galaxy of molecular gas within eight million years, unless there are additional sources of molecular gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory measurements of large-scale carbon sequestration flows in saline reservoirs

Brine saturated with CO{sub 2} is slightly denser than the original brine causing it to sink to the bottom of a saline reservoir where the CO{sub 2} is safely sequestered. However, the buoyancy of pure CO{sub 2} relative to brine drives it to the top of the reservoir where it collects underneath the cap rock as a separate phase of supercritical fluid. Without additional processes to mix the brine and CO{sub 2}, diffusion in this geometry is slow and would require an unacceptably long time to consume the pure CO{sub 2}. However, gravity and diffusion-driven convective instabilities have been hypothesized that generate enhanced CO{sub 2}-brine mixing promoting dissolution of CO{sub 2} into the brine on time scale of a hundred years. These flows involve a class of hydrodynamic problems that are notoriously difficult to simulate; the simultaneous flow of mUltiple fluids (CO{sub 2} and brine) in porous media (rock or sediment). The hope for direct experimental confirmation of simulations is dim due to the difficulty of obtaining high resolution data from the subsurface and the high pressures ({approx}100 bar), long length scales ({approx}100 meters), and long time scales ({approx}100 years) that are characteristic of these flows. We have performed imaging and mass transfer measurements in similitude-scaled laboratory experiments that provide benchmarks to test reservoir simulation codes and enhance their predictive power.

58 GEOSCIENCES↗

SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.

60 APPLIED LIFE SCIENCES↗

SU-F-J-53: A 3D Printed Phantom for the Use of Daily Quality Assurance Alignment Tests

Purpose: To discuss experiences and results for a 3D printed QA phantom used for daily alignment purposes for a six degrees-of-freedom (6DoF) table Methods: A 3D model was created using a fused deposition modeling (FDM) printer using free online computer-aided design (CAD) software. The model has been under use for daily QA alignment tests for a 6DoF couch. An aligned and angled baseplate were also printed in order to introduce known angles for 6DoF corrections during image-guidance. Unique registration contours were created on the faces of the phantom in order to achieve a better cone-beam computed tomography (CBCT) match using an auto-registration algorithm. A BB was also introduced at the center of the phantom in order to deliver an integrated daily Winston-Lutz (WL) test. Translational, rotational, and WL results were tabulated over one month. Results: The ’honeycomb’ structure of the print was apparent in the EPID images for the WL test, which affected the results of the analysis software. This was fixed by inserting a cube made of polyoxymethylene within the 3D phantom that encompass the BB. Auto-registration results for the three translational and three rotational from a known offset to the BB isocenter consistently fell within 1 mm and 0.2°, respectively. WL tests resulted in an average of 0.71 ± 0.14 mm. Conclusion: 3D printed models allow for accurate builds that can be customized to a variety of clinical needs. Results from translational, rotational, and WL show consistent results over a month’s time. Given its relatively cheap and streamlined workflow, 3D printing could be implemented into any clinic looking to create customized phantoms.

60 APPLIED LIFE SCIENCES↗

Three-dimensional tomographic imaging for dynamic radiation behavior study using infrared imaging video bolometers in large helical device plasma

A three-dimensional (3D) tomography system using four InfraRed imaging Video Bolometers (IRVBs) has been designed with a helical periodicity assumption for the purpose of plasma radiation measurement in the large helical device. For the spatial inversion of large sized arrays, the system has been numerically and experimentally examined using the Tikhonov regularization with the criterion of minimum generalized cross validation, which is the standard solver of inverse problems. The 3D transport code EMC3-EIRENE for impurity behavior and related radiation has been used to produce phantoms for numerical tests, and the relative calibration of the IRVB images has been carried out with a simple function model of the decaying plasma in a radiation collapse. The tomography system can respond to temporal changes in the plasma profile and identify the 3D dynamic behavior of radiation, such as the radiation enhancement that starts from the inboard side of the torus, during the radiation collapse. The reconstruction results are also consistent with the output signals of a resistive bolometer. These results indicate that the designed 3D tomography system is available for the 3D imaging of radiation. The first 3D direct tomographic measurement of a magnetically confined plasma has been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue assignment within lung contours are employed in generated phantoms, this erroneous assignment is reduced, generally resulting in higher doses. Lung-constrained tissue assignment also results in increased doses in regions of interest due to a reduction in the erroneous assignment of adipose to voxels within lung contours. Differences in dose metrics calculated for different computational phantoms are sensitive to radionuclide photon spectra with the largest differences for{sup 103}Pd seeds and smallest but still considerable differences for {sup 131}Cs seeds. Conclusions: Despite producing differences in CT images, dose metrics calculated using the STR, fan beam + STR, and 3D median filter techniques produce similar dose metrics. Results suggest that the accuracy of dose distributions for permanent implant lung brachytherapy is improved by applying lung-constrained tissue assignment schemes to metallic artifact corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: A fast online adaptive replanning method for VMAT using flattening filter free beams

Purpose: To develop a fast replanning algorithm based on segment aperture morphing (SAM) for online replanning of volumetric modulated arc therapy (VMAT) with flattening filter free (FFF) beams. Methods: A software tool was developed to interface with a VMAT research planning system, which enables the input and output of beam and machine parameters of VMAT plans. The SAM algorithm was used to modify multileaf collimator positions for each segment aperture based on the changes of the target from the planning (CT/MR) to daily image [CT/CBCT/magnetic resonance imaging (MRI)]. The leaf travel distance was controlled for large shifts to prevent the increase of VMAT delivery time. The SAM algorithm was tested for 11 patient cases including prostate, pancreatic, and lung cancers. For each daily image set, three types of VMAT plans, image-guided radiation therapy (IGRT) repositioning, SAM adaptive, and full-scope reoptimization plans, were generated and compared. Results: The SAM adaptive plans were found to have improved the plan quality in target and/or critical organs when compared to the IGRT repositioning plans and were comparable to the reoptimization plans based on the data of planning target volume (PTV)-V100 (volume covered by 100% of prescription dose). For the cases studied, the average PTV-V100 was 98.85% ± 1.13%, 97.61% ± 1.45%, and 92.84% ± 1.61% with FFF beams for the reoptimization, SAM adaptive, and repositioning plans, respectively. The execution of the SAM algorithm takes less than 10 s using 16-CPU (2.6 GHz dual core) hardware. Conclusions: The SAM algorithm can generate adaptive VMAT plans using FFF beams with comparable plan qualities as those from the full-scope reoptimization plans based on daily CT/CBCT/MRI and can be used for online replanning to address interfractional variations.

60 APPLIED LIFE SCIENCES↗

YNOGK: A NEW PUBLIC CODE FOR CALCULATING NULL GEODESICS IN THE KERR SPACETIME

Following the work of Dexter and Agol, we present a new public code for the fast calculation of null geodesics in the Kerr spacetime. Using Weierstrass's and Jacobi's elliptic functions, we express all coordinates and affine parameters as analytical and numerical functions of a parameter p, which is an integral value along the geodesic. This is the main difference between our code and previous similar ones. The advantage of this treatment is that the information about the turning points does not need to be specified in advance by the user, and many applications such as imaging, the calculation of line profiles, and the observer-emitter problem, become root-finding problems. All elliptic integrations are computed by Carlson's elliptic integral method as in Dexter and Agol, which guarantees the fast computational speed of our code. The formulae to compute the constants of motion given by Cunningham and Bardeen have been extended, which allow one to readily handle situations in which the emitter or the observer has an arbitrary distance from, and motion state with respect to, the central compact object. The validation of the code has been extensively tested through applications to toy problems from the literature. The source FORTRAN code is freely available for download on our Web site http://www1.ynao.ac.cn/{approx}yangxl/yxl.html.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-H-BRA-04: A Novel Superconducting Magnet Design for Optimized Patient Access and Minimal SSD for Use in a Linac-MR Hybrid

Purpose: A prototype rotating hybrid MR imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B{sub 0}. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-surface distance (SSD) is challenging. This work presents a novel superconducting magnet design that allows for a reduced SSD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. Methods: The surface of the pole plate for the magnet assembly is optimized. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package and externally controlled by MATLAB, with its key geometries defined as variables. The particle swarm optimization algorithm is used to optimize the variables subject to the minimization of a cost function. At each iteration, Opera-3D will solve the magnetic field solution over a field-of-view suitable for MR imaging and the degree of field uniformity will be assessed to calculate the value of the cost function associated with that iteration. Results: An optimized magnet assembly that generates a homogenous 0.2T magnetic field over an ellipsoid with large axis of 30 cm and small axes of 20 cm is obtained. Conclusion: The distinct features of this model are the minimal distance between the yoke’s top and the isocentre and the improved patient access. On the other hand, having homogeneity over an ellipsoid give us a larger field-of-view, essential for geometric accuracy of the MRI system. The increase of B{sub 0} from 0.2T in the present model to 0.5T is the subject of future work. Funding Sources: Alberta Innovates - Health Solutions (AIHS)| Disclosure and Conflict of Interest: B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta biplanar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗