Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Measurements of Optically Transparent and Mirrored Specimens from the POSA and EOIM III Space Flight Experiments

A selected set of optically transparent specimens and first surface mirror specimens have been examined subsequent to on-orbit exposure. Certain specimens were from the Passive Optical Sample Assembly I and II experiments flown on the MIR Space Station. Other specimens were from the Energetic Oxygen Interaction with materials III experiment flown on the STS in August 1992. A comparison of pre- and post-flight transmission of reflectance measurements, as appropriate, has been carried out. Data from different specimens includes results of measurements for IR, optical, UV and/or vacuum UV wavelength intervals. Results of these measurements clearly show the effects of molecular contamination deposits on the surfaces during the on-orbit exposures. Surface analysis on a attracted set of specimens provides and estimate of contaminant thickness and composition and provides an insight into on-orbit deposition rates and surface oxidation reactions. For both the EOIM III and POSA I & II experiments, the primary source of contamination were outgassed silicones. Both experiments received approximately the same fluence of atomic oxygen (approx. 1-2 x 1020 atoms per square centimeter). ROSA specimens received between approx. 400 and 580 equivalent sun hours (ESH) of solar radiation over an 18 month period in orbit. The EOIM specimens were on an STS flight of about 1 week duration and received only approx. 5-10 ESH of solar radiation.

Pippin, Gary↗

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force. METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL). RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

NASA Program Biomedical Research and Countermeasur↗

Broadband Noise Prediction When Turbulence Simulation Is Available - Derivation of Formulation 2B and Its Statistical Analysis

We show that a simple modification of Formulation 1 of Farassat results in a new analytic expression that is highly suitable for broadband noise prediction when extensive turbulence simulation is available. This result satisfies all the stringent requirements, such as permitting the use of the exact geometry and kinematics of the moving body, that we have set as our goal in the derivation of useful acoustic formulas for the prediction of rotating blade and airframe noise. We also derive a simple analytic expression for the autocorrelation of the acoustic pressure that is valid in the near and far fields. Our analysis is based on the time integral of the acoustic pressure that can easily be obtained at any resolution for any observer time interval and digitally analyzed for broadband noise prediction. We have named this result as Formulation 2B of Farassat. One significant consequence of Formulation 2B is the derivation of the acoustic velocity potential for the thickness and loading terms of the Ffowcs Williams-Hawkings (FW-H) equation. This will greatly enhance the usefulness of the Fast Scattering Code (FSC) by providing a high fidelity boundary condition input for scattering predictions.

Farassat, Fereidoun↗

Evaluation of Aerosol Data Assimilation and Forecasts in the NASA GEOS Model during the ASIA-AQ Campaign

Fine particulate matter (PM2.5) poses significant risks to human health and the environment by penetrating the lungs and causing respiratory and cardiovascular diseases, making it crucial to understand its sources and behavior for effective air quality management. The Goddard Earth Observing System (GEOS) Forward Processing (FP) system model, operated by the Global Modeling and Assimilation Office (GMAO) at NASA's Goddard Space Flight Center, provides real-time weather and aerosol analyses and forecasts. In addition to meteorological data assimilation, the GEOS-FP system also assimilates aerosol using Moderate Resolution Imaging Spectroradiometer (MODIS) Aerosol Optical Depth (AOD) and Aerosol Robotic Network (AERONET) AOD data. In this study, the aerosol data assimilation and forecasts performance of the GEOS-FP model were evaluated for predicting PM2.5 in Korea using observations from the Airborne and Satellite Investigation of Asian Air Quality (ASIA-AQ) campaign. The ASIA-AQ campaign, an international collaborative field study initiative, aims to enhance understanding of local air quality issues and address common challenges in interpreting satellite data and air quality modeling. Conducted in South Korea from February 15 to March 13, 2024, during the high PM2.5 concentration winter season, this campaign provided extensive airborne and ground observations for intensive analysis of PM2.5 model simulations. We demonstrate how the assimilation runs and the forecasting performance of PM2.5 at 24-hour and 48-hour intervals vary. Additionally, we analyzed the differences and characteristics of PM2.5 composition in cases of long-range transport and local emissions. Using ASIA-AQ airborne data, we also examined the vertical profile of fine particulate matter. Through the intensive observations of this campaign, the GEOS model was assessed over South Korea using both in situ and airborne measurements to establish a baseline and identify priorities for future development.

Seunghee Lee↗

Shallow Soil Polychlorinated Biphenyl Site Assessment Report: General Services Administration Reclamation Yard Solid Waste Management Unit 010

This report presents a summary of the shallow soil polychlorinated biphenyl (PCB) site assessment activities that occurred from December 2020 through July 2022 at General Services Administration Reclamation Yard, Solid Waste Management Unit (SWMU) 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, three separate shallow soil plumes, known as the Northeast Shallow Soil PCB Plume, Southeast Shallow Soil PCB Plume, and West Shallow Soil PCB Plume, were identified for this site. The activities presented in this report include seven field events conducted between December 2020 and July 2022, which include shallow soil sample collection in the Northeast, Southeast, and West Shallow Soil PCB Plumes. AECOM Technical Services, Inc., personnel collected 330 soil samples from 118 boring locations. The samples were collected at 0.5-foot depth intervals to various depths based on analytical results and depth to groundwater. The soil samples were submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 8082A for total PCBs. Several soil samples had PCB concentrations above the State of Florida Direct Exposure Residential and Industrial Soil Cleanup Target Levels (SCTLs), and two soil samples had PCB concentrations above the State of Florida Leachability for Groundwater. No soil borings were located beneath impervious surfaces, such as concrete or asphalt. The current Land Use Control Implementation Plan (LUCIP) covers PCBs in soils above the residential SCTL, which includes the paved areas.

soil assessment↗

Data-free inference of the joint distribution of uncertain model parameters.

It is known that, in general, the correlation structure in the joint distribution of model parameters is critical to the uncertainty analysis of that model. Very often, however, studies in the literature only report nominal values for parameters inferred from data, along with confidence intervals for these parameters, but no details on the correlation or full joint distribution of these parameters. When neither posterior nor data are available, but only summary statistics such as nominal values and confidence intervals, a joint PDF must be chosen. Given the summary statistics it may not be reasonable nor necessary to assume the parameters are independent random variables. We demonstrate, using a Bayesian inference procedure, how to construct a posterior density for the parameters exhibiting self consistent correlations, in the absence of data, given (1) the fit-model, (2) nominal parameter values, (3) bounds on the parameters, and (4) a postulated statistical model, around the fit-model, for the missing data. Our approach ensures external Bayesian updating while marginalizing over possible data realizations. We then address the matching of given parameter bounds through the choice of hyperparameters, which are introduced in postulating the statistical model, but are not given nominal values. We discuss some possible approaches, including (1) inferring them in a separate Bayesian inference loop and (2) optimization. We also perform an empirical evaluation of the algorithm showing the posterior obtained with this data free inference compares well with the true posterior obtained from inference against the full data set.

99 GENERAL AND MISCELLANEOUS↗

Data-free inference of uncertain model parameters.

It is known that, in general, the correlation structure in the joint distribution of model parameters is critical to the uncertainty analysis of that model. Very often, however, studies in the literature only report nominal values for parameters inferred from data, along with confidence intervals for these parameters, but no details on the correlation or full joint distribution of these parameters. When neither posterior nor data are available, but only summary statistics such as nominal values and confidence intervals, a joint PDF must be chosen. Given the summary statistics it may not be reasonable nor necessary to assume the parameters are independent random variables. We demonstrate, using a Bayesian inference procedure, how to construct a posterior density for the parameters exhibiting self consistent correlations, in the absence of data, given (1) the fit-model, (2) nominal parameter values, (3) bounds on the parameters, and (4) a postulated statistical model, around the fit-model, for the missing data. Our approach ensures external Bayesian updating while marginalizing over possible data realizations. We then address the matching of given parameter bounds through the choice of hyperparameters, which are introduced in postulating the statistical model, but are not given nominal values. We discuss some possible approaches, including (1) inferring them in a separate Bayesian inference loop and (2) optimization. We also perform an empirical evaluation of the algorithm showing the posterior obtained with this data free inference compares well with the true posterior obtained from inference against the full data set.

99 GENERAL AND MISCELLANEOUS↗

Adaptive time scaling for accelerating explicit finite element analysis

A method for accelerating an explicit finite element analysis (FEA) simulation of a modeled system or process includes performing an initial iteration of the FEA simulation according to a baseline time interval via an FEA computing network, and calculating a criteria ratio of a predetermined set of scaling criteria for the modeled system or process. The method includes determining a time-scaling factor using the criteria ratio via the FEA computing network as a function of the criteria ratio, and then applying the time-scaling factor to the baseline time interval to generate a scaled time interval. The scaled time interval accelerates simulation time of the FEA simulation. The method includes performing a subsequent iteration of the explicit FEA simulation at the scaled time interval using the FEA computing network. The process continues for subsequent iterations, with the time-scaling factor adapting with each iteration.

Chen, Jian↗

Modern Era Retrospective Restrospective-Analysis for Research and Applications (MERRA) Data and Services at the GES DISC

The Modern Era Retrospective-analysis for Research and Applications (MERRA) dataset is a NASA satellite era, 30 year (1979 - present), reanalysis using the Goddard Earth Observing System Data Assimilation System, Version 5 (GEOS-5). The project, run out of NASA's Global Modeling and Assimilation Office at Goddard Space Flight Center, provides the science and application communities with a state-of-the-art global analysis with emphasis on improved estimates of the hydrological cycle over a broad range of weather and climate time scales. MERRA products are generated as a long-term synthesis that places the NASA EOS suite of observations in a climate context. The MERRA analysis is performed at a horizontal resolution of 2/3 longitude x 1/2 latitude (540x361 global gridpoints) with observational analyses every 6 hours. The MERRA output data will include 3 dimensional state fields for every 6 hourly analysis cycle on 42 pressure levels (or 72 terrain following model coordinate levels) from the surface through the stratosphere. Several data products are specifically designed to support chemistry and stratosphere transport modeling. The 2 dimensional surface and atmospheric diagnostics (numbering 259) are being stored on the native grid at 1 hourly intervals. These include radiation and vertical integrals of the atmosphere for water and energy budget studies and also surface diagnostics where the diurnal cycle is important. The one hourly surface and near surface data product will also facilitate research on the integrated analysis of Earth system observations in the land, ocean and cryosphere. The MERRA products are archived and distributed by the Goddard Earth Sciences Data and Information Services Center (GES DISC) through its Modeling DISC Web (MDISC) portal. Multiple data access methods and services are available for MERRA data through MDISC: (1) Mirador offers a quick, comprehensive search of MERRA and all GES DISC archived data holdings, allowing searches on keywords, location names or latitude/longitude box, and date/time, with responses within a few seconds. (2) Giovanni is a GES DISC developed Web application that provides data visualization and analysis online. Giovanni features popular visualizations such as latitude-longitude maps, animations, cross sections, profiles, time series, etc. and some basic statistical analysis functions such as scatter plots and correlation coefficient maps. Users are able to download results in several different formats, including Google Earth. (3) On-the-fly parameter subsetting of data within a spatial/temporal window is provided through a simple select and click Web page. (4) MERRA data are also available via OPeNDAP, GrADS Data Server (GDS) and can be converted to netCDF on the fly.

Berrick, Stephen W.↗

Systematic study of projection biases in weak lensing analysis

We present a systematic study of projection biases in the weak lensing analysis of the first year of data from the Dark Energy Survey (DES) experiment. In the analysis we used a $\Lambda$CDM model and three two-point correlation functions. We show that these biases are a consequence of projecting, or marginalizing, over parameters like $h$, $\Omega_b$, $n_s$ and $\Omega_\nu h^2$ that are both poorly constrained and correlated with the parameters of interest like $\Omega_m$, $\sigma_8$ and $S_8$. Covering the relevant parameter space we show that the projection biases are a function of where the true values of the poorly constrained parameters lie with respect to the parameter priors. For example, biases in the position of the posteriors can exceed the 1.5$\sigma$ level if the true values of $h$ and $n_s$ are close to the top of the prior's range and the true values of $\Omega_b$ and $\Omega_\nu h^2$ are close to the bottom of the range of their priors. We also show that in some cases the 1D credible intervals can be over-specified by as much as 30% and coverage can be as low as 27%. Finally we estimate these projection biases for the analysis of three and six years worth of DES data.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine Temperature Grid Continuous Energy Cross Section Generation for Monte Carlo Analysis of Xe-100 Design

The standard “A Compact ENDF (ACE)” data libraries used by Monte Carlo based reactor physics codes calculations are provided by Los Alamos National Laboratory (LANL) with a temperature interval mostly of 300 K (e.g. 300 K, 600 K, 900 K) for the cross sections and between 100 K and 200 K for the thermal scattering libraries (TSL). However, some codes such as MCNP lack capability to perform on-the-fly temperature interpolation during simulation both for neutron and TSL cross-sections. To evaluate the impact related to Doppler broadening and spectrum shift associated with TSL changes, this paper explores the potential of adopting a temperature grid finer than the ones contained in the standard data libraries. A 50 K temperature grid was employed to quantify the error in neutronics calculations due to temperature grid resolution. This was achieved by comparing the results of this study (50 K temperature interval) against the results obtained with standard data libraries (>100 K temperature interval). While the adopted grid primarily relies on the ENDF/B-VII.1 library, for neutron cross-sections, it utilizes ENDF/B-VIII.0 library for TSL. The analyses confirmed that the accuracy of neutronics calculations is satisfactory when using a 50 K temperature grid. Notably, adopting a 50 K temperature grid, as opposed to standard libraries or coarser temperature grids, could lead to a difference of no more than a few hundred pcm in dk for both fresh fuel and burnt fuel. The most sensitive reaction type to the temperature grid was as expected identified as the capture cross-section of U-238.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of Weibull strength parameters and Batdorf flow-density constants for volume- and surface-flaw-induced fracture in ceramics

The calculation of shape and scale parameters of the two-parameter Weibull distribution is described using the least-squares analysis and maximum likelihood methods for volume- and surface-flaw-induced fracture in ceramics with complete and censored samples. Detailed procedures are given for evaluating 90 percent confidence intervals for maximum likelihood estimates of shape and scale parameters, the unbiased estimates of the shape parameters, and the Weibull mean values and corresponding standard deviations. Furthermore, the necessary steps are described for detecting outliers and for calculating the Kolmogorov-Smirnov and the Anderson-Darling goodness-of-fit statistics and 90 percent confidence bands about the Weibull distribution. It also shows how to calculate the Batdorf flaw-density constants by uing the Weibull distribution statistical parameters. The techniques described were verified with several example problems, from the open literature, and were coded. The techniques described were verified with several example problems from the open literature, and were coded in the Structural Ceramics Analysis and Reliability Evaluation (SCARE) design program.

Pai, Shantaram S.↗

Analysis of transit users’ waiting tolerance in response to unplanned service disruptions

Public transit not only provides an affordable, efficient, and green service but also plays a critical role in the development of resilient transportation systems in urban areas. Transit disruption as a common incident in transit service operation can severely affect the resiliency of the transportation system as well as users’ satisfaction. While it is of great interest to transportation authorities to understand passengers’ decision behavior during unplanned transit disruptions in order to implement efficacious recovery strategies, still little is known about users’ behavior in case of such incidents. The scarcity of available data is a major underlying factor for this gap. Utilizing a recently collected data of transit users in the Chicago metropolitan area, this study investigates transit users’ waiting tolerance during unplanned service disruptions and disclose the factors that affect their behavior. A set of interval-censored accelerated failure time models using different survival distributions are developed, compared, and the factors influencing the survival functions of the waiting tolerance are identified. The results of the analysis reveal that, for instance, having experience of using ridesharing services decreases users’ waiting tolerance during a disruption. Further, built-environment attributes (such as the density of pedestrian-oriented links and transit service frequency), availability of alternative modes, transit service type, user’s attitudes, and trip characteristics turn to be significant in users’ decision behavior.

99 GENERAL AND MISCELLANEOUS↗

Clinical Implications of the Tumor Volume Reduction Rate in Head-and-Neck Cancer During Definitive Intensity-Modulated Radiotherapy for Organ Preservation

Purpose: To investigate the prognostic value of the volume reduction rate (VRR) in patients with head-and-neck cancer treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Seventy-six patients with oropharyngeal cancer (OPC) and another 76 with hypopharyngeal cancer (HPC) were enrolled in volumetric analysis. All patients received allocated radiotherapy courses. Adaptive computed tomography was done 4 to 5 weeks after the start of IMRT. Primary tumor volume measurement was derived using separate images for the pretreatment gross tumor volume (pGTV) and the interval gross tumor volume. Results: In the OPC group, the pGTV ranged from 6.6 to 242.6 mL (mean, 49.9 mL), whereas the value of the VRR ranged from 0.014 to 0.74 (mean, 0.43). In HPC patients, the pGTV ranged from 4.1 to 152.4 mL (mean, 35.6 mL), whereas the VRR ranged from -1.15 to 0.79 (mean, 0.33). Multivariate analysis of the primary tumor relapse-free survival for OPC revealed three prognostic factors: T4 tumor (p = 0.0001, hazard ratio 7.38), pGTV {>=}20 mL (p = 0.01, hazard ratio 10.61), and VRR <0.5 (p = 0.001, hazard ratio 6.49). Multivariate analysis of the primary tumor relapse-free survival for HPC showed two prognostic factors: pGTV {>=}30 mL (p = 0.001, hazard ratio 2.87) and VRR <0.5 (p = 0.03, hazard ratio 2.25). Conclusion: The VRR is an outcome predictor for local control in OPC and HPC patients treated with IMRT. Those with large tumor volumes or a VRR <0.5 should be considered for a salvage operation or a dose-escalation scheme.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Simple Statistical Analysis of Historical Data to Understand Wind Ramp Events

As renewable resources start providing an increasingly larger percentage of our energy needs, we need to improve our understanding of these intermittent resources so we can manage them better. In the case of wind resources, large unscheduled changes in the energy output, called ramp events, make it challenging to keep the load and the generation balanced. In this report, we show that simple statistical analysis of the historical data on wind energy generation can provide insights into these ramp events. In particular, this analysis can help answer questions such as the time period during the day when these events are likely to occur, the relative severity of positive and negative ramps, and the frequency of their occurrence. As there are several ways in which ramp events can be defined and counted, we also conduct a detailed study comparing different options. Our results indicate that the statistics are relatively insensitive to these choices, but depend on utility-specific factors, such as the magnitude of the ramp and the time interval over which this change occurs. These factors reflect the challenges faced by schedulers and operators in keeping the load and generation balanced and can change over the years. We conduct our analysis using data from wind farms in the Tehachapi Pass region in Southern California and the Columbia Basin region in Northern Oregon; while the results for other regions are likely to be different, the report describes the benefits of conducting simple statistical analysis on wind generation data and the insights that can be gained through such analysis.

99 GENERAL AND MISCELLANEOUS↗

Photosynthetic fractionation of 13C and concentrations of dissolved CO2 in the central equatorial Pacific during the last 255,000 years

Carbon isotopically based estimates of CO2 levels have been generated from a record of the photosynthetic fractionation of 13C [is equivalent to epsilon(p)] in a central equatorial Pacific sediment core that spans the last approximately 255 ka. Contents of 13C in phytoplanktonic biomass were determined by analysis of C37 alkadienones. These compounds are exclusive products of Prymnesiophyte algae which at present grow most abundantly at depths of 70-90 m in the central equatorial Pacific. A record of the isotopic composition of dissolved CO2 was constructed from isotopic analyses of the planktonic foraminifera Neogloboquadrina dutertrei, which calcifies at 70-90 m in the same region. Values of epsilon(p), derived by comparison of the organic and inorganic delta values, were transformed to yield concentrations of dissolved CO2 [is equivalent to c(e)] based on a new, site-specific calibration of the relationship between epsilon(p) and c(e). The calibration was based on reassessment of existing epsilon(p) versus c(e) data, which support a physiologically based model in which epsilon(p) is inversely related to c(e). Values of PCO2, the partial pressure of CO2 that would be in equilibrium with the estimated concentrations of dissolved CO2, were calculated using Henry's law and the temperature determined from the alkenone-unsaturation index U(K/37). Uncertainties in these values arise mainly from uncertainties about the appropriateness (particularly over time) of the site-specific relationship between epsilon(p) and 1/c(e). These are discussed in detail and it is concluded that the observed record of epsilon(p) most probably reflects significant variations in delta pCO2, the ocean-atmosphere disequilibrium, which appears to have ranged from approximately 110 microatmospheres during glacial intervals (ocean > atmosphere) to approximately 60 microatmospheres during interglacials. Fluxes of CO2 to the atmosphere would thus have been significantly larger during glacial intervals. If this were characteristic of large areas of the equatorial Pacific, then greater glacial sinks for the equatorially evaded CO2 must have existed elsewhere. Statistical analysis of air-sea pCO2 differences and other parameters revealed significant (p<0.01) inverse correlations of delta pCO2 with sea surface temperature and with the mass accumulation rate of opal. The former suggests response to the strength of upwelling, the latter may indicate either drawdown of CO2 by siliceous phytoplankton or variation of [CO2]/[Si(OH)4] ratios in upwelling waters.

NASA Discipline Exobiology↗

Incidence of Second Malignancies in Prostate Cancer Patients Treated With Low-Dose-Rate Brachytherapy and Radical Prostatectomy

Purpose: To compare the second malignancy incidence in prostate cancer patients treated with brachytherapy (BT) relative to radical prostatectomy (RP) and to compare both groups with the cancer incidence in the general population. Methods and Materials: From 1998 to 2010, 2418 patients were treated with Iodine 125 prostate BT monotherapy at the British Columbia Cancer Agency, and 4015 referred patients were treated with RP. Cancer incidence was compared with the age-matched general population using standardized incidence ratios (SIRs). Pelvic malignancies included invasive and noninvasive bladder cancer and rectal cancer. Cox multivariable analysis was performed with adjustment for covariates to determine whether treatment (RP vs BT) was associated with second malignancy risk. Results: The median age at BT was 66 years and at RP 62 years. The SIR comparing BT patients with the general population was 1.06 (95% confidence interval [CI] 0.91-1.22) for second malignancy and was 1.53 (95% CI 1.12-2.04) for pelvic malignancy. The SIR comparing RP patients with the general population was 1.11 (95% CI 0.98-1.25) for second malignancy and was 1.11 (95% CI 0.82-1.48) for pelvic malignancy. On multivariable analysis, older age (hazard ratio [HR] 1.05) and smoking (HR 1.65) were associated with increased second malignancy risk (P<.0001). Radical prostatectomy was not associated with a decreased second malignancy risk relative to BT (HR 0.90, P=.43), even when excluding patients who received postprostatectomy external beam radiation therapy (HR 1.13, P=.25). Older age (HR 1.09, P<.0001) and smoking (HR 2.17, P=.0009) were associated with increased pelvic malignancy risk. Radical prostatectomy was not associated with a decreased pelvic malignancy risk compared with BT (HR 0.57, P=.082), even when excluding postprostatectomy external beam radiation therapy patients (HR 0.87, P=.56). Conclusions: After adjustment for covariates, BT patients did not have an increased second malignancy risk compared with RP patients. Further follow-up of this cohort is needed given the potential latency of radiation-induced malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods

Purpose: To compare the reproducibility and accuracy of R2-relaxometry MRI for estimation of liver iron concentration (LIC) between in-house analysis and FDA-approved commercially available third party results. Methods: All MR studies were performed on a 1.5T scanner. Multi-echo spin-echo scans with a fixed TR and increasing TE values of 6 ms, 9 ms, 12 ms, 15 ms, and 18 ms (spaced at 3 ms intervals) were used. Post-processing of the images to calculate mean relaxivity, R2, included drawing of regions of interest to include the whole liver on mid-slice. The relationship between liver R2 values and estimated LIC calculated with in-house analysis and values reported by an external company (FerriScan{sup ®}, Resonance Health, Australia) were assessed with correlation coefficients and Bland–Altman difference plots. Continuous variables are presented as mean ± standard deviation. Significance was set at p value < 0.05. Results: 474 studies from 175 patients were included in the study (mean age 10.4 ± 4.2 years (range 1–18 years); 254 studies from girls, 220 studies from boys). LIC ranged from 0.6 to 43 mg/g dry tissue, covering a broad range from normal levels to extremely high iron levels. Linearity between proprietary and in-house methods was excellent across the observed range for R2 (31.5 to 334.8 s{sup −1}); showing a correlation coefficient of r = 0.87, p < 0.001. Bland–Altman R2 difference plot between the two methods shows a mean bias of + 21.5 s{sup −1} (range − 47.0 to + 90.0 s{sup −1} between two standard deviations). LIC reported by FerriScan{sup ®} compared with LIC estimated in-house with R2 as reported by FerriScan{sup ®} agreed strongly, (r = 1.0, p < 0.001). Conclusion: R2 relaxometry MR imaging for liver iron concentration estimation is reproducible between proprietary FDA-approved commercial software and in-house analysis methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗