Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

A discourse on sensitivity analysis for discretely-modeled structures

A descriptive review is presented of the most recent methods for performing sensitivity analysis of the structural behavior of discretely-modeled systems. The methods are generally but not exclusively aimed at finite element modeled structures. Topics included are: selections of finite difference step sizes; special consideration for finite difference sensitivity of iteratively-solved response problems; first and second derivatives of static structural response; sensitivity of stresses; nonlinear static response sensitivity; eigenvalue and eigenvector sensitivities for both distinct and repeated eigenvalues; and sensitivity of transient response for both linear and nonlinear structural response.

Adelman, Howard M.↗

Controls Algorithms, Models, and Stability Assessments of the RCS and TVC systems on Mars Ascent Vehicle

This paper presents a control systems overview of the Mars Ascent Vehicle (MAV) control design and stability analysis with two separate control methods: Thrust Vector Control (TVC) based control using main engine thrust and Reaction Control System (RCS) via thrusters. A pole-placement TVC controller is proposed to address quickly peaking thrust produced by the MAV solid propulsion engine. The controllerutilizes real-time parameter estimation to calculate control gains using an online pole-placement method. The pole-placement technique allows the controller to maintain constant stability margins throughout the flight under changing parameters and rapidly peaking thrust. A mathematical stability proof via Lyapunov inequality and Nichols method is demonstrated to support the stability of the method. In addition to the TVC control, a phase-plane based RCS control logic is applied to the vehicle for roll control during ascent and all axes during coast phases of flight. The logic implemented is an on-off type logic that applies pre-determined thrusters firings in reference to boundary parameters of pointing and rate error chosen to balance desired pointing with stability. A describing function methodology is applied to the non-linear phase plane loop response to determine linear stability across all flight phases. The controller additionally applies command alteration logic to output signals to account for RCS hardware limitations. The following paper will provide the methodology for controller implementation of the TVC and RCS, and provide a summary of results of the MAV performance applying the aforementioned control design.

Han Woong Bae↗

Collaborative Research: Polymer Macrocycles: A novel topology to control dynamics of rubbery materials

Understanding the dynamics of polymers of different topologies is an important field of study and one of the most important unanswered questions in this field is "how do circular polymers move," particularly in the melt state. New information suggests that molecular topology, specifically circular rings, impacts the response of materials in nanometer- scale confinement. The work performed here tackles these subjects through a collaboration in which specialists in polymer synthesis, polymer rheology and scattering methods, and in the physics of nanoconfinement work together to investigate the thermophysical behavior of circular macromolecules. The project goals are to use a novel synthesis method of "green" oxidative polymerization to produce high purity macrocycles and to investigate their linear viscoelastic behavior in order to fully characterize the dynamics of circular macromolecules to sizes that correspond to linear molecule entanglement densities higher than previously obtainable with synthetic polymers. Chemical chain end characterization and critical edge fractionation coupled with direct visualization of the prepared polymers through the use of polymer amplification methods are proposed in order to quantify the numbers of circular and linear molecules in each sample. The study of the linear viscoelastic response of blends of linear and circular molecules is also to be undertaken in the project. Nonlinear viscoelastic measurements, including extensional viscosity, are to be made. Strong differences in behavior between linear chains and circular ones also provides an important opportunity for new technology to break the "magic triangle" for tires: it is believed that improving one of the three key attributes - traction, wear, rolling resistance - necessarily sacrifices at least one of the others. Rubber made from cyclic polymers has the potential to break out of this triangle by reducing the so-called Payne effect in reinforced rubbers because circular macromolecules are less sensitive to nanoconfinement than their linear counterparts. The work has as one objective to characterize the impact of nanoconfinement on the behavior of large circular macromolecules. In addition, the dynamics of carbon black filled circular macromolecules are to be studied to test the hypothesis that the resulting rubbery materials will exhibit a reduced Payne effect.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature and temporal dependence of the optical response for a radiochromic dosimeter

Purpose: Both temporal and thermal dependencies of the dose response have been observed in radiochromic dosimeters. As these dependencies may be influenced by the dose level, the present study investigates the temperature dependence during irradiation and the temporal change of the optical response following irradiation of radiochromic dosimeters at a range of doses. Methods: Cuvette samples of the PRESAGE Trade-Mark-Sign radiochromic dosimeter were irradiated within a dose range of 0-10 Gy at irradiation temperatures within 5-35 Degree-Sign C and postirradiation storage within 6-30 Degree-Sign C. The optical response due to irradiation was measured using a standard spectrophotometer and the data were analyzed in terms of thermal and temporal change. Results: The initial dose response was linear over the applied dose range independent of irradiation temperature. However, the optical response to a specific dose increased exponentially with irradiation temperature corresponding to an activation energy of 0.114 {+-} 0.007 eV. The temporal change in dose response after irradiation consisted of an offset, an auto-oxidation rate with activation energy 0.84 {+-} 0.03 eV, and an initial exponential increase in optical response (1.6 {+-} 0.2 eV) followed by an exponential decrease in optical response (0.98 {+-} 0.08 eV). These contributions depended on both storage temperature and the dose given, leading to a nonlinear dose response with time at low storage temperatures and a high auto-oxidation rate at high storage temperatures. Conclusions: Thermal equilibration is important to the radiochromic dosimeter investigated due to an exponential change in dose response with irradiation temperature and a considerable postirradiation temporal change in response. For the dosimeter version investigated in this study, a compromise in storage temperature has to be made between increasing the nonlinearity of the dose response with time and inducing a high auto-oxidation rate.

36 MATERIALS SCIENCE↗

Design and fabrication of engineering model fiber-optics detector

The design and fabrication of an annular ring detector consisting of optical fibers terminated with photodetectors is described. The maximum width of each concentric ring has to be small enough to permit the resolution of a Ronchi ruling transform with a dot spacing of 150 microns. A minimum of 100 concentric rings covering a circular area of 2.54 cm diameter also is necessary. A fiber-optic array consisting of approximately 89,000 fibers of 76 microns diameter was fabricated to meet the above requirements. The fibers within a circular area of 2.5 cm diameter were sorted into 168 adjacent rings concentric with the center fiber. The response characteristics of several photodetectors were measured, and the data used to compare their linearity of response and dynamic range. Also, coupling loss measurements were made for three different methods of terminating the optical fibers with a photodetector.

Mcsweeney, A.↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

Non-NASA Center↗

Observations on Dynamic Qualification Testing of a Component with Nonlinear Deadband Interfaces

Typical flight hardware dynamic qualification tests exhibit nearly linear structural response when exposed to acceleration inputs from low to full qualification levels. Even in these “linear” cases, there is typically a trend of increasing damping with test levels. The nonlinear mechanism behind this increase in energy dissipation well understood – typically stick/slip hysteresis at joint connections. This paper is concerned with a different type of nonlinearity: deadbands at structural interfaces. Deadband nonlinearities can have a significant influence on structural response and modal/spectral characteristics which can present difficulties in test, analysis, and structural certification. This subject nonlinear behaviour is observed during flight qualification testing of the AQUARIUS instrument and discussed here. Simple physical reasoning and analytical model is utilized to explain the behaviour which is consistent with the test findings.

Majed, Arya↗

Radiation-Related Risk of Cancers of the Upper Digestive Tract among Japanese Atomic Bomb Survivors

As a follow-up to the comprehensive work on solid cancer incidence in the Life Span Study (LSS) cohort of atomic bomb survivors between 1958 and 1998, we report here on updated radiation risk estimates for upper digestive tract cancers. In this study, we added 11 years of follow-up (1958–2009), used improved radiation dose estimates, considered effects of smoking and alcohol consumption and performed dose-response analyses by anatomical sub-site. In examining 52 years'worth of data, we ascertained the occurrence of 394 oral cavity/pharyngeal cancers, 486 esophageal cancers and 5,661 stomach cancers among 105,444 subjects. The radiation risk for oral cavity/pharyngeal cancer, other than salivary gland, was elevated but not significantly so. In contrast, salivary gland cancer exhibited a strong linear dose response with excess relative risk (ERR) of 2.54 per Gy [95% confidence interval (CI): 0.69 to 6.1]. Radiation risk decreased considerably with increasing age at time of exposure (–66% per decade, 95% CI: –88% to –32%). The dose response for esophageal cancer was statistically significant under a simple linear, linear-quadratic and quadratic model. Both linear-quadratic and quadratic models described the data better than a simple linear model and, of the two, the quadratic model showed a marginally better fit based on the Akaike Information Criteria. Sex difference in linear ERRs was not statistically significant; however, when the dose-response shape was allowed to vary by sex, statistically significant curvature was found among males, with no evidence of quadratic departure from linearity among females. The risk for stomach cancer increased significantly with dose and there was little evidence for quadratic departure from linearity among either males or females. The sex-averaged ERR at age 70 was 0.33 per Gy (95% CI: 0.20 to 0.47). The ERR decreased significantly (–1.93 power of attained age, 95% CI: –2.94 to –0.82) with increasing attained age, but not with age at exposure, and was higher in females than males (P = 0.02). Our results are largely consistent with the results of prior LSS analyses. Salivary gland, esophageal and stomach cancers continue to show significant increases in risk with radiation dose. Adjustment for lifestyle factors had almost no impact on the radiation effect estimates. Further follow-up of the LSS cohort is important to clarify the nature of radiation effects for upper digestive tract cancers, especially for oral cavity/pharyngeal and esophageal cancers, for which detailed investigation for dose-response shape could not be conducted due to the small number of cases.

60 APPLIED LIFE SCIENCES↗

Characterization of a novel two dimensional diode array the ''magic plate'' as a radiation detector for radiation therapy treatment

Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the ''magic plate'' (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. Methods: The prototype MP is an 11 x 11 detector array based on thin (50 {mu}m) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary ''drop-in'' technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Results: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180 deg. Angular dependence was within 3.5% for the gantry angles {+-} 75 deg. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 x 30 cm{sup 2} field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. Conclusions: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with ''drop-in'' packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non Linear Step By Step Seismic Response and the Push Over Analysis Comparison of a Reinforced Concrete of Ductile Frames 25 Level Building

Based on a ductile frames 25 level building, a non-linear analysis with increased monotonically lateral loads (Push-Over) was made in order to determine its collapse and its principal responses were compared against the time-history seismic responses determined with the SCT-EW-85 record. The seismic-resistance design and faced to gravitational loads was made according to the Complementary Technical Norms of Concrete Structures Design (NTC-Concrete) and the NTC-Seismic of the Mexico City Code (RDF-04), satisfying the limit service states (relative lateral displacement between story height maximum relations, story drifts {<=}0.012) and failure (seismic behavior factor, Q = 3). The compressible (soft) seismic zone III{sub b} and the office use type (group B) were considered. The non-lineal responses were determined with nominal and over-resistance effects. The comparison were made with base shear force-roof lateral displacement relations, global distribution of plastic hinges, failure mechanics tendency, lateral displacements and story drift and its distribution along the height of the building, local and global ductility demands, etc. For the non-linear static analysis with increased monotonically lateral loads, was important to select the type of lateral forces distribution.

58 GEOSCIENCES↗

Characterization of TLD-100 micro-cubes for use in small field dosimetry

At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-linear dynamic analysis of geared systems, part 2

A good understanding of the steady state dynamic behavior of a geared system is required in order to design reliable and quiet transmissions. This study focuses on a system containing a spur gear pair with backlash and periodically time-varying mesh stiffness, and rolling element bearings with clearance type non-linearities. A dynamic finite element model of the linear time-invariant (LTI) system is developed. Effects of several system parameters, such as torsional and transverse flexibilities of the shafts and prime mover/load inertias, on free and force vibration characteristics are investigated. Several reduced order LTI models are developed and validated by comparing their eigen solution with the finite element model results. Several key system parameters such as mean load and damping ratio are identified and their effects on the non-linear frequency response are evaluated quantitatively. Other fundamental issues such as the dynamic coupling between non-linear modes, dynamic interactions between component non-linearities and time-varying mesh stiffness, and the existence of subharmonic and chaotic solutions including routes to chaos have also been examined in depth.

Singh, Rajendra↗

Ab-initio modeling of electromechanical coupling at Si surfaces

The electromechanical coupling at the silicon (100) and (111) surfaces was studied via density functional theory by calculating the response of the ionization potential and the electron affinity to different types of strain. We find a branched strain response of those two quantities with different coupling coefficients for negative and positive strain values. This can be attributed to the reduced crystal symmetry due to anisotropic strain, which partially lifts the degeneracy of the valence and conduction bands. Only the Si(111) electron affinity exhibits a monotonously linear strain response, as the conduction band valleys remain degenerate under strain. The strain response of the surface dipole is linear and seems to be dominated by volume changes. Our results may help to understand the mechanisms behind electromechanical coupling at an atomic level in greater detail and for different electronic and atomic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ARE INTERNETWORK MAGNETIC FIELDS IN THE SOLAR PHOTOSPHERE HORIZONTAL OR VERTICAL?

Using many observations obtained during 2007 with the Spectro-Polarimeter of the Hinode Solar Optical Telescope , we explore the angular distribution of magnetic fields in the quiet internetwork regions of the solar photosphere. Our work follows from the insight of Stenflo, who examined only linear polarization signals in photospheric lines, thereby avoiding complications of the analysis arising from the differing responses to linear and circular polarization. We identify and isolate regions of a strong polarization signal that occupy only a few percent of the observed quiet Sun area yet contribute most to the net linear polarization signal. The center-to-limb variation of the orientation of linear polarization in these strong signal regions indicates that the associated magnetic fields have a dominant vertical orientation. In contrast, the great majority of the solar disk is occupied by much weaker linear polarization signals. The orientation of the linear polarization in these regions demonstrates that the field orientation is dominantly horizontal throughout the photosphere. We also apply our analysis to Stokes profiles synthesized from the numerical MHD simulations of Rempel as viewed at various oblique angles. The analysis of the synthetic data closely follows that of the observations, lending confidence to using the simulations as a guide for understanding the physical origins of the center-to-limb variation of linear polarization in the quiet Sun area.

79 ASTRONOMY AND ASTROPHYSICS↗

Finite Elements Analysis of a Composite Semi-Span Test Article With and Without Discrete Damage

AS&M Inc. performed finite element analysis, with and without discrete damage, of a composite semi-span test article that represents the Boeing 220-passenger transport aircraft composite semi-span test article. A NASTRAN bulk data file and drawings of the test mount fixtures and semi-span components were utilized to generate the baseline finite element model. In this model, the stringer blades are represented by shell elements, and the stringer flanges are combined with the skin. Numerous modeling modifications and discrete source damage scenarios were applied to the test article model throughout the course of the study. This report details the analysis method and results obtained from the composite semi-span study. Analyses were carried out for three load cases: Braked Roll, LOG Down-Bending and 2.5G Up-Bending. These analyses included linear and nonlinear static response, as well as linear and nonlinear buckling response. Results are presented in the form of stress and strain plots. factors of safety for failed elements, buckling loads and modes, deflection prediction tables and plots, and strainage prediction tables and plots. The collected results are presented within this report for comparison to test results.

Lovejoy, Andrew E.↗

Dynamic Tensile Response of a Fe–49Co–2V Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also required to bear mechanical load under various loading and environmental conditions. In this study, a Fe–49Co–2V alloy was dynamically characterized in tension with a Kolsky tension bar and a Drop–Hopkinson bar at various strain rates and temperatures. Dynamic tensile stress–strain curves of the Fe–49Co–2V alloy were obtained at strain rates ranging from 40 to 230 s -1 and temperatures from - 100 to 100 °C. All dynamic tensile stress–strain curves exhibited an initial linear elastic response to an upper yield followed by Lüders band response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature, whereas the hardening rate was independent of strain rate or temperature. The Fe–49Co–2V alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗