Search NASA⌕ Search

SEARCH · Search NASA

Results for “probability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Probability of illness definition for the Skylab flight crew health stabilization program

Management and analysis of crew and environmental microbiological data from SMEAT and Skylab are discussed. Samples were collected from ten different body sites on each SMEAT and Skylab crew-member on approximately 50 occasions and since several different organisms could be isolated from each sample, several thousand lab reports were generated. These lab reports were coded and entered in a computer file and from the file various tabular summaries were constructed.

Source record↗

Spectroscopic analysis of transition state energy levels - Bending-rotational spectrum and lifetime analysis of H3 quasibound states

Converged quantum mechanical calculations of scattering matrices and transition probabilities are reported for the reaction of H with H2 with total angular momentum 0, 1, and 4 as functions of total energy in the range 0.85-1.15 eV on an accurate potential energy surface. The resonance structure is illustrated with Argand diagrams. State-to-state reactive collision delay times and lifetimes are presented. For J = 0, 1, and 4, the lowest-energy H3 resonance is at total energies of 0.983, 0.985, and 1.01 eV, respectively, with lifetimes of about 16-17 fs. For J = 1 and 4 there is a higher-energy resonance at 1.10-1.11 eV. For J = 1 the lifetime is about 4 fs and for J = 4 it is about 1 fs.

Zhao, Meishan↗

Functional Data Analysis Applied to Modeling of Severe Acute Mucositis and Dysphagia Resulting From Head and Neck Radiation Therapy

Purpose: Current normal tissue complication probability modeling using logistic regression suffers from bias and high uncertainty in the presence of highly correlated radiation therapy (RT) dose data. This hinders robust estimates of dose-response associations and, hence, optimal normal tissue–sparing strategies from being elucidated. Using functional data analysis (FDA) to reduce the dimensionality of the dose data could overcome this limitation. Methods and Materials: FDA was applied to modeling of severe acute mucositis and dysphagia resulting from head and neck RT. Functional partial least squares regression (FPLS) and functional principal component analysis were used for dimensionality reduction of the dose-volume histogram data. The reduced dose data were input into functional logistic regression models (functional partial least squares–logistic regression [FPLS-LR] and functional principal component–logistic regression [FPC-LR]) along with clinical data. This approach was compared with penalized logistic regression (PLR) in terms of predictive performance and the significance of treatment covariate–response associations, assessed using bootstrapping. Results: The area under the receiver operating characteristic curve for the PLR, FPC-LR, and FPLS-LR models was 0.65, 0.69, and 0.67, respectively, for mucositis (internal validation) and 0.81, 0.83, and 0.83, respectively, for dysphagia (external validation). The calibration slopes/intercepts for the PLR, FPC-LR, and FPLS-LR models were 1.6/−0.67, 0.45/0.47, and 0.40/0.49, respectively, for mucositis (internal validation) and 2.5/−0.96, 0.79/−0.04, and 0.79/0.00, respectively, for dysphagia (external validation). The bootstrapped odds ratios indicated significant associations between RT dose and severe toxicity in the mucositis and dysphagia FDA models. Cisplatin was significantly associated with severe dysphagia in the FDA models. None of the covariates was significantly associated with severe toxicity in the PLR models. Dose levels greater than approximately 1.0 Gy/fraction were most strongly associated with severe acute mucositis and dysphagia in the FDA models. Conclusions: FPLS and functional principal component analysis marginally improved predictive performance compared with PLR and provided robust dose-response associations. FDA is recommended for use in normal tissue complication probability modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Objectively Quantifying Radiation Esophagitis With Novel Computed Tomography–Based Metrics

Purpose: To study radiation-induced esophageal expansion as an objective measure of radiation esophagitis in patients with non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy. Methods and Materials: Eighty-five patients had weekly intra-treatment CT imaging and esophagitis scoring according to Common Terminlogy Criteria for Adverse Events 4.0, (24 Grade 0, 45 Grade 2, and 16 Grade 3). Nineteen esophageal expansion metrics based on mean, maximum, spatial length, and volume of expansion were calculated as voxel-based relative volume change, using the Jacobian determinant from deformable image registration between the planning and weekly CTs. An anatomic variability correction method was validated and applied to these metrics to reduce uncertainty. An analysis of expansion metrics and radiation esophagitis grade was conducted using normal tissue complication probability from univariate logistic regression and Spearman rank for grade 2 and grade 3 esophagitis endpoints, as well as the timing of expansion and esophagitis grade. Metrics' performance in classifying esophagitis was tested with receiver operating characteristic analysis. Results: Expansion increased with esophagitis grade. Thirteen of 19 expansion metrics had receiver operating characteristic area under the curve values >0.80 for both grade 2 and grade 3 esophagitis endpoints, with the highest performance from maximum axial expansion (MaxExp1) and esophageal length with axial expansion ≥30% (LenExp30%) with area under the curve values of 0.93 and 0.91 for grade 2, 0.90 and 0.90 for grade 3 esophagitis, respectively. Conclusions: Esophageal expansion may be a suitable objective measure of esophagitis, particularly maximum axial esophageal expansion and esophageal length with axial expansion ≥30%, with 2.1 Jacobian value and 98.6 mm as the metric value for 50% probability of grade 3 esophagitis. The uncertainty in esophageal Jacobian calculations can be reduced with anatomic correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revisiting pressure-induced phase transition in silicon clathrates using Ge substitution

Ba 8 Si 39 Ge 7 and Ba 8 Si 29 Ge 17 have been studied at high pressure using x-ray diffraction and x-ray absorption spectroscopy (XAS) at the Ge K edge. In Ba 8 Si 39 Ge 7 , a transition is observed similar to the one in Ba 8 Si 46 , apparently isostructural. However, the XAS data analysis shows that the transformation is related to the off-centering of the Ba atoms. A theoretical model based on a Landau potential suggests that this transition is second order, with a symmetry-breaking mechanism related to the Ba displacement probably initiated by the vacancy creation or local distortion predicted theoretically. Lastly, this analysis gives a coherent picture of the phase transition mechanism. In the case of Ba 8 Si 29 Ge 17 , such phase transition is not observed as the Ba atoms appear already off-center at ambient pressure.

36 MATERIALS SCIENCE↗

Evaluation of a Class of Simple and Effective Uncertainty Methods for Sparse Samples of Random Variables and Functions

When very few samples of a random quantity are available from a source distribution of unknown shape, it is usually not possible to accurately infer the exact distribution from which the data samples come. Under-estimation of important quantities such as response variance and failure probabilities can result. For many engineering purposes, including design and risk analysis, we attempt to avoid under-estimation with a strategy to conservatively estimate (bound) these types of quantities -- without being overly conservative -- when only a few samples of a random quantity are available from model predictions or replicate experiments. This report examines a class of related sparse-data uncertainty representation and inference approaches that are relatively simple, inexpensive, and effective. Tradeoffs between the methods' conservatism, reliability, and risk versus number of data samples (cost) are quantified with multi-attribute metrics use d to assess method performance for conservative estimation of two representative quantities: central 95% of response; and 10 -4 probability of exceeding a response threshold in a tail of the distribution. Each method's performance is characterized with 10,000 random trials on a large number of diverse and challenging distributions. The best method and number of samples to use in a given circumstance depends on the uncertainty quantity to be estimated, the PDF character, and the desired reliability of bounding the true value. On the basis of this large data base and study, a strategy is proposed for selecting the method and number of samples for attaining reasonable credibility levels in bounding these types of quantities when sparse samples of random variables or functions are available from experiments or simulations.

97 MATHEMATICS AND COMPUTING↗

Density estimation via measure transport: Outlook for applications in the biological sciences

Abstract One among several advantages of measure transport methods is that they allow or a unified framework for processing and analysis of data distributed according to a wide class of probability measures. Within this context, we present results from computational studies aimed at assessing the potential of measure transport techniques, specifically, the use of triangular transport maps, as part of a workflow intended to support research in the biological sciences. Scenarios characterized by the availability of limited amount of sample data, which are common in domains such as radiation biology, are of particular interest. We find that when estimating a distribution density function given limited amount of sample data, adaptive transport maps are advantageous. In particular, statistics gathered from computing series of adaptive transport maps, trained on a series of randomly chosen subsets of the set of available data samples, leads to uncovering information hidden in the data. As a result, in the radiation biology application considered here, this approach provides a tool for generating hypotheses about gene relationships and their dynamics under radiation exposure.

gene expression data↗

Risk Management of NPP Incidents

A diagnostic model for managing the risk of NPP incidents attending different irregularities of equipment operation is examined for the example of the oil delivery system of the main circulation pump. The model includes the construction of a graph of the operation of the oil system and ranking in order to obtain indices of priority for monitoring information flow that reflect the actuation probability of each form of protection. The results of the analysis can used as input data for predicting the duration of a stable state of a technological system in the course of operation on the basis of stochastic extrapolation of the parameters by means of single-channel queuing systems with finite storage – technological protection and blocking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surface Structure and Corrosion Behavior of Mg{sub 68−x}Zn{sub 28+x}Ca{sub 4}(x = 0.4) Bulk Metallic Glasses after Immersion in Ringer’s Solution

The main aim of the present study was to determine the impact of Zn on the surface structure and corrosion behavior of Mg-based metallic glasses after immersion in Ringer’s solution. The corrosion rate expressed by the volume of released hydrogen in the form of a function of immersion time in Ringer’s solution at 37 °C was presented. The surface structure and corrosion products, which were formed during the immersion tests, were examined by means of scanning electron microscopy and the following spectroscopic methods: x-ray photoelectron spectroscopy, x-ray diffractometry, secondary ion mass spectrometry and energy-dispersive x-ray spectroscopy. As a result of the investigations of the surface structure, oxides (MgO, CaO, ZnO), hydroxides (Mg(OH){sub 2}, Ca(OH){sub 2}) and carbonates (CaCO{sub 3}) were identified. The analysis of the research results allowed the determination of a probable course and corrosion mechanism of the above-mentioned metallic glasses during immersion in Ringer’s solution.

36 MATERIALS SCIENCE↗

Collective motion in prolate γ-rigid nuclei within minimal length concept via a quantum perturbation method

Based on the minimal length concept, inspired by Heisenberg algebra, a closed analytical formula is derived for the energy spectrum of the prolate γ-rigid Bohr–Mottelson Hamiltonian of nuclei, within a quantum perturbation method (QPM), by considering a scaled Davidson potential in β shape variable. In the resulting solution, called X(3)-D-ML, the ground state and the first β-band are all studied as a function of the free parameters. The fact of introducing the minimal length concept with a QPM makes the model very flexible and a powerful approach to describe nuclear collective excitations of a variety of vibrational-like nuclei. The introduction of scaling parameters in the Davidson potential enables us to get a physical minimum of this latter in comparison with previous works. The analysis of the corrected wave function, as well as the probability density distribution, shows that the minimal length parameter has a physical upper bound limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design Considerations for Financing a National Trust to Advance the Deployment of Geologic CO2 Storage and Motivate Best Practices

This paper explores how the flawed, widely held public policy view of an ever growing risk associated with long-term carbon dioxide (CO2) storage profoundly influences the public policy dialogue about how to best address the long term risk profile for geologic storage. In order to accomplish this, the authors present evidence from the rapidly emerging science and engineering of CO2 storage which demonstrates that, with proper site characterization and sound operating practices, retention of stored CO2 will increase with time thus invalidating the premise of an ever growing risk. The authors focus on key issues of fit, interplay, and scalability associated with a trust fund funded by a hypothetical $1/tonCO2 tipping fee for each ton of CO2 stored in the United States under WRE450 and WRE550 climate policies. The authors conclude there is no intrinsic value in creating a trust fund predicated solely on collecting a fixed fee that is not mapped to site-specific risk profiles. If left to grow unchecked, a trust fund that is predicated on a constant stream of annual payments unrelated to the site’s risk profile could result in the accumulation of hundreds of billions to more than a trillion dollars in real terms contributing to significant opportunity cost of capital. Further, rather than mitigating the financial consequences of long-term CCS risks, this analysis suggests a blanket $1/tonCO2 tipping fee may increase the probability and frequency of long-term risk by eliminating financial incentives for sound operating behavior and site selection criteria – contribute to moral hazard. At a minimum, effective use of a trust fund requires: (1) strong oversight regarding site selection and fund management, and (2) a clear process by which the fund is periodically valued and funds collected are mapped to the risk profile of the pool of covered CCS sites. Without appropriate checks and balances, there is no a priori reason to believe that the amount of funds held in trust will map to the actual amount of funds needed to address long-term care expenses and delimited compensatory damages. For this reason, the authors conclude that the financing of a trust fund or other risk management instrument should be based on a site delimited estimate of future expected financial consequences rather than on the random adoption of a fixed funding stream, e.g., a blanket $1/ton , because it ‘sounds’ reasonable.

carbon dioxide capture and storage↗

Accelerated Partial Breast Irradiation: 5-Year Results of the German-Austrian Multicenter Phase II Trial Using Interstitial Multicatheter Brachytherapy Alone After Breast-Conserving Surgery

Purpose: To evaluate the impact of accelerated partial breast irradiation on local control, side effects, and cosmesis using multicatheter interstitial brachytherapy as the sole method for the adjuvant local treatment of patients with low-risk breast cancer. Methods and Materials: 274 patients with low-risk breast cancer were treated on protocol. Patients were eligible for the study if the tumor size was < 3 cm, resection margins were clear by at least 2 mm, no lymph node metastases existed, age was >35 years, hormone receptors were positive, and histologic grades were 1 or 2. Of the 274 patients, 175 (64%) received pulse-dose-rate brachytherapy (D{sub ref} = 50 Gy). and 99 (36%) received high-dose-rate brachytherapy (D{sub ref} = 32.0 Gy). Results: Median follow-up was 63 months (range, 9-103). Only 8 of 274 (2.9%) patients developed an ipsilateral in-breast tumor recurrence at the time of analysis. The 5-year actuarial local recurrence-free survival probability was 98%. The 5- year overall and disease-free survival probabilities of all patients were 97% and 96%, respectively. Contralateral in-breast malignancies were detected in 2 of 274 (0.7%) patients, and distant metastases occurred in 6 of 274 (2.2%). Late side effects {>=}Grade 3 (i.e., breast tissue fibrosis and telangiectasia) occurred in 1 patient (0.4%, 95%CI:0.0-2.0%) and 6 patients (2.2%, 95%CI:0.8-4.7%), respectively. Cosmetic results were good to excellent in 245 of 274 patients (90%). Conclusions: The long-term results of this prospective Phase II trial confirm that the efficacy of accelerated partial breast irradiation using multicatheter brachytherapy is comparable with that of whole breast irradiation and that late side effects are negligible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM Polymorphisms Predict Severe Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: The ataxia telangiectasia mutated (ATM) gene mediates detection and repair of DNA damage. We investigated associations between ATM polymorphisms and severe radiation-induced pneumonitis (RP). Methods and Materials: We genotyped 3 potentially functional single nucleotide polymorphisms (SNPs) of ATM (rs1801516 [D1853N/5557G>A], rs189037 [-111G>A] and rs228590) in 362 patients with non-small cell lung cancer (NSCLC), who received definitive (chemo)radiation therapy. The cumulative severe RP probabilities by genotypes were evaluated using the Kaplan-Meier analysis. The associations between severe RP risk and genotypes were assessed by both logistic regression analysis and Cox proportional hazard model with time to event considered. Results: Of 362 patients (72.4% of non-Hispanic whites), 56 (15.5%) experienced grade ≥3 RP. Patients carrying ATM rs189037 AG/GG or rs228590 TT/CT genotypes or rs189037G/rs228590T/rs1801516G (G-T-G) haplotype had a lower risk of severe RP (rs189037: GG/AG vs AA, adjusted hazard ratio [HR] = 0.49, 95% confidence interval [CI], 0.29-0.83, P=.009; rs228590: TT/CT vs CC, HR=0.57, 95% CI, 0.33-0.97, P=.036; haplotype: G-T-G vs A-C-G, HR=0.52, 95% CI, 0.35-0.79, P=.002). Such positive findings remained in non-Hispanic whites. Conclusions: ATM polymorphisms may serve as biomarkers for susceptibility to severe RP in non-Hispanic whites. Large prospective studies are required to confirm our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LUX trigger efficiency

The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. Here, the trigger efficiency, which is defined as the probability that an event of interest is selected for offline analysis, is studied using raw data obtained from both electron recoil (ER) and nuclear recoil (NR) calibrations. The measured efficiency exceeds 98% at a pulse area of 90 detected photons, which is well below the WIMP analysis threshold on the S2 pulse area. The efficiency also exceeds 98% at recoil energies of 1.3 keV and above, for both ER and NR. In conclusion, the measured trigger efficiency varies between 99% and 100% over the fiducial volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size-dependent quantum diffusion of Gd atoms within Fe nano-corrals

We systematically studied the size-dependent quantum diffusion of Gd atoms within Fe circular quantum corrals on Ag(111). By varying the size of the quantum corrals, different types of patterns are observed inside the corrals, including a single dot and circular orbits for the diffusion of Gd adatoms. In addition, the motion of the adatoms also forms circular-like orbits outside the corral. Via quantitative analysis, we confirm that the regions with adatoms' high visiting probability are consistent with the positions of the local electronic density-of-states maxima, both inside and outside the corrals within a < 0.2 nm offset. The results agree well with kinetic Monte Carlo simulations that utilize the experimentally determined interaction between Gd and Fe circular corrals. These findings demonstrate that one can engineer adatom motion by controlling the size of the quantum corrals.

36 MATERIALS SCIENCE↗

One-bond 13 C– 13 C spin-coupling constants in saccharides: a comparison of experimental and calculated values by density functional theory using solid-state 13 C NMR and X-ray crystallography

Methyl aldohexopyranosides were 13 C-labeled at contiguous carbons, crystallized, and studied by single-crystal X-ray crystallography and solid-state 13 C nuclear magnetic resonance (NMR) spectroscopy to examine the degree to which density functional theory (DFT) can calculate one-bond 13C–13C spin-coupling constants ( 1 J CC ) in saccharides with sufficient accuracy to permit their use in MA'AT analysis, a newly-reported hybrid DFT/NMR method that provides probability distributions of molecular torsion angles in solution (Zhang et al., J. Phys. Chem. B, 2017, 121, 3042–3058; Meredith et al., J. Chem. Inf. Model., 2022, 62, 3135–3141). Experimental 1 J CC values in crystalline samples of the doubly 13 C-labeled compounds were measured by solid-state 13 C NMR and compared to those calculated from five different DFT models: (1) 1 J CC values calculated from single structures identical to those observed in crystalline samples by X-ray crystallography (all atom refinement); (2) 1 J CC values calculated from the single structures in (1) but after Hirshfeld atom refinement (HAR); (3) 1 J CC values calculated from the single structures in (1) after DFT-optimization of hydrogen atoms only; and (4 and 5) 1 J CC values calculated in rotamers of torsion angle θ 2 (C1–C2–O2–O2H) or ω(C4–C5–C6–O6) from which either specific or generalized parameterized equations were obtained and used to calculate 1 J CC values in the specific θ 2 or ω rotamers observed in crystalline samples. Good qualitative agreement was observed between calculated 1 J CC values and those measured by solid-state 13 C NMR regardless of the DFT model, but in no cases were calculated 1 J CC values quantitative, differing (over-estimated) on average by 4–5% from experimental values. These findings, and those reported recently from solution NMR studies (Tetrault et al., J. Phys. Chem. B 2022, 126, 9506–9515), indicate that improvements in DFT calculations are needed before calculated 1 J CC values can be used directly as reliable constraints in MA'AT analyses of saccharides in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗