Unintentional islanding detection via wide-area communication of reference signals.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.
Oak Ridge National Laboratory is conducting a project for the Environmental Protection Agency (EPA) Office of Superfund Remediation and Technology Innovation involving derivation of cancer risk coefficients for ingestion of radionuclides in soil. EPA provides guidance on quantifying gastrointestinal (GI) absorption of a chemical in a given medium for use in risk evaluations including assessments for Superfund sites. Essentially, a medium-specific GI absorption fraction may be applied if and only if there is sound information to support that value. Otherwise, the applied GI absorption fraction should be the best estimate of fractional absorption of the chemical when ingested in highly soluble form. Based on our review of the literature on GI absorption of elements in soil, we have concluded that for many elements there is convincing evidence of substantially reduced absorption in ingested soil compared with ingestion in readily dissolved form. This report summarizes the reviewed information and proposes a comprehensive set of GI absorption fractions for ingestion of elements in soil. For most elements, the proposed GI absorption fractions are lower than the default absorption fractions recommended by the International Commission on Radiological Protection for radionuclides ingested in highly soluble form, even though considerable conservatism has been incorporated into the proposed soil-specific GI absorption fractions.
Reactive oxygen species are one of the most important species produced in a plasma. In particular the role of atomic oxygen and the hydroxyl radical OH has attracted many studies ranging from plasma medicine to plasma-driven biocatalysis and water treatment. Atomic oxygen and the hydroxyl radical OH are very reactive and react unselectively with many different substrates. The quantification of atomic oxygen and OH is challenging because of their reactivity and unknown reactions and rate constants.
The U.S. Department of Energy launched the Advanced Building Construction (ABC) Initiative in 2019 to modernize and streamline building renovation and construction processes that facilitate the integration of high-performance and low-carbon solutions in the U.S. building stock. There are four attributes of ABC that are the focus of the Initiative: affordable, fast, appealing, and low carbon. Substantial improvements have been made to reduce operational carbon emissions of buildings through efficiency and electrification. However, to achieve low-carbon new construction buildings, increased efforts to reduce the embodied carbon of buildings are needed. Embodied carbon emissions in buildings come primarily from the manufacturing of building envelope materials such as concrete, steel, lumber, and glass, among others. Recent studies show that construction and renovation of buildings account for 5% of energy use and 10% of carbon emissions globally.
The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.1. The most significant changes for HyRAM+ version 5.1 from HyRAM+ version 5.0 are updated default leak frequency values for propane, new default component counts for different fuel types, and an improved fuel specification view in the graphical user interface.
This report aims to bridge the gap between advanced nuclear reactor vendors and methanol producers seeking decarbonization. It equips both parties with tools and preliminary information for integrating clean heat from advanced reactors into novel methanol production processes. The proposed investigation in this report involves a three-step approach: 1. Design of Current and Decarbonized Process Models for Methanol Production. This report initiates process modeling of two novel methanol production pathways, with their overall energy requirements comparative to classical methanol production (see Figure ES1). The two process models provide the foundation for analyzing integration of hermos-electric generation from advanced nuclear reactors. 2. Identification of Coupling Points to Integrate Advanced Reactors. This report investigates the integration with two advanced reactor technologies: light-water reactors (LWRs) and high-temperature gas reactors (HTGRs). The key coupling points between advanced nuclear reactors and the production facilities associated with the two decarbonized methanol process pathways are identified. 3. Preliminary Heat and Electricity Transfer Design from Reactors to Methanol Production Sites. The preliminary designs for piping and instrumentation to transfer heat from the boundary of advanced reactor technology location to the boundary of methanol production site are evaluated within the context of decarbonized pathways. The pipe analysis for heat transfer adheres to relevant codes and specifications from American Society of Mechanical Engineering. A simplified design for transmission of electricity to the industrial site has been provided.
Port electrification can take many forms, such as electrifying cargo handling equipment or deploying a microgrid to power critical port infrastructure. To help evaluate the growing challenge of increased electrification and its impacts on the system, Pacific Northwest National Laboratory developed this Port Electrification Handbook with support from the U.S. Department of Energy, Office of Electricity’s Microgrids R&D [research and development] program. The goals of this handbook are the following: (1) Help port operators and planners evaluate different electrification technologies; (2) Explain how these technologies could aid and impact ports and surrounding communities; and (3) Provide step-by-step considerations for port electrification.
Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.
The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).
Port electrification can take many forms, such as electrifying cargo handling equipment or deploying a microgrid to power critical port infrastructure. To help evaluate the growing challenge of increased electrification and its impacts on the system, the U.S. Department of Energy, Office of Electricity’s Microgrids R&D [research and development] program created this Port Electrification Handbook through a project led by Pacific Northwest National Laboratory. The goals of this handbook are the following: help port operators and planners evaluate different electrification technologies, explain how these technologies could aid and impact ports and surrounding communities, provide step-by-step considerations for port electrification.
The deployment of heavy-duty (HD) hydrogen fuel cell vehicles that are entering the market now is driving the need for expanded HD hydrogen refueling station infrastructure to meet demand. This expansion must prioritize safety and reliability, necessitating careful consideration of the associated risks. In this study, we use a light-duty (LD) hydrogen refueling station as a comparative tool to quantify the risks for a HD station, which is essentially a scaled-up version of a LD station.
The HyRAM+ software is an open-source toolkit that provides publicly available models and default input values to enable straightforward and consistent safety assessments for hydrogen and other alternative fuel systems, such as natural gas and propane. The HyRAM+ quantitative risk assessment calculation incorporates annual likelihood of leaks or failures for both compressed gaseous and liquefied flammable fuels, as well as probabilistic models for the effects of heat flux and overpressure. HyRAM
Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.