Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Hard x-ray nanobeam characterization by coherent diffraction microscopy

We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field-driven sense elements for chirality-dependent domain wall detection and storage

A method for locally sensing and storing data of transverse domain wall chirality in planar nanowire logic and memory systems is presented. Patterned elements, in close proximity to the nanowires, respond to the asymmetry in the stray field from the domain wall to produce a chirality-dependent response. When a bias field is applied, a stray field-assisted reversal of the element magnetization results in a reversed remanent state, measurable by scanning electron microscopy with polarization analysis (SEMPA). The elements are designed as triangles with tips pointing toward the nanowire, allowing the shape anisotropy to be dominated by the base but having a portion with lower volume and lower energy barrier closest to the domain wall. Micromagnetic modeling assists in the design of the nanowire-triangle systems and experiments using SEMPA confirm the importance of aspect ratio and spacing given a constant bias field magnitude.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

60 APPLIED LIFE SCIENCES↗

Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution scanning electron microscope for in situ investigation of swift heavy ion induced modification of solid surfaces

A new in situ high resolution electron microscope (HRSEM) setup has been designed and integrated into the materials science beamline (M-branch) of the universal linear accelerator at Gesellschaft fuer Schwerionenforschung, Darmstadt for in situ investigations of swift heavy ion induced surface modifications. Special ports for in situ experiments are installed at the HRSEM chamber to connect it to the high vacuum beamline, which is equipped with suitable beam control and shaping devices. In order to demonstrate the feasibility and power of this new instrument, first experiments were performed on a 50-nm-thick Fe{sub 2}O{sub 3} film on Si substrate, which exhibited submicrometer size holes due to irradiation induced dewetting in a previous experiment. We have demonstrated that with our new instrument, the development of individual dewetting holes as a function of the ion fluence can be investigated and even the interaction between them can be studied. To illustrate pattern formation during grazing incidence, 3.6 MeV/u {sup 131}Xe ion irradiation was carried out on a 25-nm-thick NiO film on SiO{sub 2}/Si at a tilt angle of 75 deg. The SEM image sequence recorded during the experiment reveals the development of a lamellaelike structure also seen before in ex situ experiments. With our new in situ setup, however, we are able to not only investigate the overall average pattern formation, but also to track the formation and decay of individual linking structures, which would be hardly possible in a standard ex situ experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrathoracic Patterns of Failure for Non-Small-Cell Lung Cancer With Positron-Emission Tomography/Computed Tomography-Defined Target Delineation

Purpose: Dosimetric studies suggested several advantages to defining the radiotherapy target by using positron-emission tomography (PET)/computed tomography (CT) compared with CT alone. We investigated patterns of treatment failure in patients treated to a PET-defined radiotherapy target and evaluated the effect of standardized uptake value (SUV) on recurrence after radiotherapy. Methods and Materials: Thirty-five patients with non-small-cell lung cancer who underwent PET/CT simulation for definitive radiotherapy were included. The PET/CT scans were obtained with patients in the treatment position with custom immobilization for use in radiation treatment planning. Nine to 11 regions of interest (ROIs) were identified for each patient, including the primary tumor and regional nodes. Maximum SUV, volume, and mean dose received were recorded for each ROI, and follow-up scans were used to evaluate for recurrence in each ROI. Results: We identified 353 ROIs from 35 patients; 5.7% of patients developed isolated out-of-field recurrences. Recursive partitioning analysis was used to divide ROIs into low, intermediate, and high risk by using volume and SUV. All low-risk ROIs with volumes less than 1.2 cm{sup 3} were recurrence free compared with 73% of intermediate-risk ROIs (volume {>=}1.2 cm{sup 3}; SUV {<=}13.8) and 29% of high-risk ROIs (SUV > 13.8). Conclusion: Limiting the target volume to predominantly PET-positive disease resulted in a low rate of isolated out-of-field recurrences. The SUV and volume were predictors of recurrence. Recursive partitioning analysis identified SUVs greater than 13.8 as the best identifier of ROIs at the greatest risk of recurrence; control rates for this subgroup did not show a dose-response relationship within the range of doses administered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stacking of lamellae in Mg/Al hydrotalcites: Effect of metal ion concentrations on morphology

A hybrid nanocomposite based on the intercalation of carbonate anion has been synthesized through co-precipitation technique. Powder X-ray diffraction patterns (PXRD) showed pure layered double hydroxide (LDH) phases having crystallite size around 20 and 13 nm in 'a' and 'c' crystallographic directions, respectively. Fourier transform infrared and Raman spectroscopy measurements exhibit shifting of bands with increase of divalent metal ion concentration and it further suggests the presence of carbonate anions. Differential scanning calorimetry (DSC) and thermogravimetry analysis (TGA) exhibit the three stages of thermal degradation, which is characteristic behaviour of layered double hydroxide. CHN and energy dispersive X-ray analysis support the PXRD and spectroscopy results. The nature of charge observed through Zeta potential analyzer is positive. Transmission electron microscope (TEM) exhibits the characteristic LDH platelet morphology with the platelets stacked one above the other.

36 MATERIALS SCIENCE↗

Toward In Situ Synchrotron Mapping of Crystal Selection Processes during Crystal Growth

In this work, we present an automated and rapid method for non-destructive mapping of crystal grains in a rod-shaped sample. The approach was designed for application to in situ float-zone crystal growth experiments at an x-ray synchrotron source, but could be useful in other applications. The methods have been tested on a TiO 2 boule grown in an optical float zone furnace. The approach applies a statistical filter to polycrystalline diffraction patterns on 2D detectors to rapidly determine the degree of powder-quality 1of the signal. When larger crystals emerge in the growth, their position, size and shape can be tracked using an automated blob-tracking algorithm that follows individual Bragg peaks as a function of position in a grid-scan, even when multiple crystals are contributing spots to diffraction images. This method is found to be robust as the same crystal shape can be independently reconstructed using different sets of Bragg reflections. Image segmentation methods are then used to map out the polycrystalline grains. We also note that other information about crystal quality, such as mosaicity or strain state, may be inferred and mapped from the intensity variation of the Bragg peaks at different locations within the sample.

36 MATERIALS SCIENCE↗

Bulk and Surface Morphologies of ABC Miktoarm Star Terpolymers Composed of PDMS, PI, and PMMA Arms

DIM miktoarm star copolymers, composed of polydimethylsiloxane [D], poly(1,4-isoprene) [I], and poly(methyl methacrylate) [M], were synthesized using a newly developed linking methodology with 4-allyl-1,1-diphenylethylene as a linking agent. The equilibrium bulk morphologies of the DIM stars were found to range from [6.6.6] tiling patterns to alternating lamellar and alternating cylindrical morphologies, as determined experimentally by small-angle X-ray scattering and transmission electron microscopy and confirmed by dissipative particle dynamics and self-consistent field theory based arguments. The thin film morphologies, which differ from those found in the bulk, were identified by scanning electron microscopy, coupled with oxygen plasma etching. Finally, square arrays of the PDMS nanodots and empty core cylinders were formed on silica after oxygen plasma removal of the poly(1,4-isoprene) and poly(methyl methacrylate) which generated nanostructured substrates decorated with these features readily observable.

36 MATERIALS SCIENCE↗

Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector

A method for x-ray phase contrast imaging is introduced in which only one absorption grating and a microfocus x-ray source in a tabletop setup are used. The method is based on precise subpixel position determination of the x-ray pattern projected by the grating directly from the pattern image. For retrieval of the phase gradient and absorption image (both images obtained from one exposure), it is necessary to measure only one projection of the investigated object. Thus, our method is greatly simplified compared with the phase-stepping method and our method can significantly reduce the time-consuming scanning and possibly the unnecessary dose. Furthermore, the technique works with a fully polychromatic spectrum and gives ample variability in object magnification. Consequently, the approach can open the way to further widespread application of phase contrast imaging, e.g., into clinical practice. The experimental results on a simple testing object as well as on complex biological samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Backscatter Diffraction in Low Vacuum Conditions

Most current scanning electron microscopes (SEMs) have the ability to analyze samples in a low vacuum mode, whereby a partial pressure of water vapor is introduced into the SEM chamber, allowing the characterization of nonconductive samples without any special preparation. Although the presence of water vapor in the chamber degrades electron backscatter diffraction (EBSD) patterns, the potential of this setup for EBSD characterization of nonconductive samples is immense. In this chapter we discuss the requirements, advantages and limitations of low vacuum EBSD (LV-EBSD), and present how this technique can be applied to a two-phase ceramic composite as well as hydrated biominerals as specific examples of when LV-EBSD can be invaluable.

36 MATERIALS SCIENCE↗

Ultrasonic imaging of materials under unconventional circumstances

This paper reflects the contents of the plenary talk given by Nico Felicien Declercq. “Ultrasonic Imaging of materials” covers a wide technological area with main purpose to look at and to peek inside materials. In an ideal world one would manage to examine materials like a clairvoyant. Fortunately this is impossible hence nature has offered sufficient challenges to mankind to provoke curiosity and to develop science and technology. Here we focus on the appearance of certain undesired physical effects that prohibit direct imaging of materials in ultrasonic C-scans. Furthermore we try to make use of these effects to obtain indirect images of materials and therefore make a virtue of necessity. First we return to one of the oldest quests in the progress of mankind: how thick is ice? Our ancestors must have faced this question early on during migration to Northern Europe and to the America’s and Asia. If a physicist or engineer is not provided with helpful tools such as a drill or a device based on ultrasound, it is difficult to determine the ice thickness. Guided waves, similar to those used for nondestructive testing of thin plates in structural health monitoring can be used in combination with the human ear to determine the thickness of ice. To continue with plates, if an image of its interior is desired high frequency ultrasonic pulses can be applied. It is known by the physicist that the resolution depends on the wavelength and that high frequencies usually result in undesirably high damping effects inhibiting deep penetration into the material. To the more practical oriented engineer it is known that it is advantageous to polish surfaces before examination because scattering and diffraction of sound lowers the image resolution. Random scatterers cause some blurriness but cooperating scatters, causing coherent diffraction effects similar to the effects that cause DVD’s to show rainbow patterns under sunlight, can cause spooky images and erroneous measurements of material properties. However when properly understood, diffraction effects, for instance if one has no other options but to work with frequencies that are fortuitously very effectively diffracted by the surface structure of a material under investigation, can be used to obtain high contract images or to obtain information that would normally be hidden from standard C-scan techniques. Similar contrast enhancement is also obtained for oblique C-scans of composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative SEM and TEM analyses of apatite phases prepared by a multi-sample loading device

Highlights: • A multi-sample loading device which ultrasonically disperses samples was developed. • Comparative EM analyses on various apatite phases were efficiently carried out. • SEM-EDS data revealed distinctive values of O/P and Ca/P intensity ratios. • TEM-SAED data presented characteristic structural features of apatite phases. • Lattice parameters of bone and fossil apatite were affected by CO{sub 3} content. - Abstract: Comparative chemical and structural characterization of various apatite phases from both synthetic and natural sources were carried out by utilizing a multi-sample loading device developed for scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses. The device is capable of spraying nanoparticles via ultrasonication, and four separate samples were loaded on a single TEM grid by a masking tool to characterize different apatite phases in consistent instrumental and analytical conditions. SEM energy dispersive spectroscopy (EDS) analysis of the apatite samples revealed distinctive values of O/P and Ca/P intensity ratios except for the fossil apatite due to its high proportion of externally originating phases. Selected area electron diffraction (SAED) pattern analysis presented the characteristic lattice parameters of the apatite phases, especially the bone and fossil apatite which had CO{sub 3}in their chemistry. Analyzing distinctive chemical and structural features among varied apatite phases can be efficiently carried out through electron microscopy with multiple samples on a single TEM grid, and such methods can be employed for characterizing a wider range of materials.

36 MATERIALS SCIENCE↗

Patterns of Failure After Proton Therapy in Medulloblastoma; Linear Energy Transfer Distributions and Relative Biological Effectiveness Associations for Relapses

Purpose: The pattern of failure in medulloblastoma patients treated with proton radiation therapy is unknown. For this increasingly used modality, it is important to ensure that outcomes are comparable to those in modern photon series. It has been suggested this pattern may differ from photons because of variations in linear energy transfer (LET) and relative biological effectiveness (RBE). In addition, the use of matching fields for delivery of craniospinal irradiation (CSI) may influence patterns of relapse. Here we report the patterns of failure after the use of protons, compare it to that in the available photon literature, and determine the LET and RBE values in areas of recurrence. Methods and Materials: Retrospective review of patients with medulloblastoma treated with proton radiation therapy at Massachusetts General Hospital (MGH) between 2002 and 2011. We documented the locations of first relapse. Discrete failures were contoured on the original planning computed tomography scan. Monte Carlo calculation methods were used to estimate the proton LET distribution. Models were used to estimate RBE values based on the LET distributions. Results: A total of 109 patients were followed for a median of 38.8 months (range, 1.4-119.2 months). Of the patients, 16 experienced relapse. Relapse involved the supratentorial compartment (n=8), spinal compartment (n=11), and posterior fossa (n=5). Eleven failures were isolated to a single compartment; 6 failures in the spine, 4 failures in the supratentorium, and 1 failure in the posterior fossa. The remaining patients had multiple sites of disease. One isolated spinal failure occurred at the spinal junction of 2 fields. None of the 70 patients treated with an involved-field-only boost failed in the posterior fossa outside of the tumor bed. We found no correlation between Monte Carlo-calculated LET distribution and regions of recurrence. Conclusions: The most common site of failure in patients treated with protons for medulloblastoma was outside of the posterior fossa. The most common site for isolated local failure was the spine. We recommend consideration of spinal imaging in follow-up and careful attention to dose distribution in the spinal junction regions. Development of techniques that do not require field matching may be of benefit. We did not identify a direct correlation between lower LET values and recurrence in medulloblastoma patients treated with proton therapy. Patterns of failure do not appear to differ from those in patients treated with photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molten salt synthesis, characterization, and luminescence properties of GdNbO{sub 4}/LuTaO{sub 4}:Eu{sup 3+} phosphors

Graphical abstract: Well crystallized GdNbO4:Eu3{sup +} and LuTaO{sub 4}:Eu3{sup +} in the presence of fluxes were formed under reduced temperature in contrast to conventional method and their photophysical properties were studied. - Highlights: • Molten salt method was used to assemble two phosphors. • Both GdNbO{sub 4}:Eu{sup 3+} and LuTaO{sub 4}:Eu{sup 3+} could be red emissive. • The two powders were well dispersed as nano-particles. - Abstract: GdNbO{sub 4}:Eu{sup 3+} and LuTaO{sub 4}:Eu{sup 3+} have been successfully prepared with different fluxes (NaCl, KCl, NaCl and KCl) by the molten salt method. X-ray diffraction (XRD) patterns illustrated that well crystallized GdNbO{sub 4}:Eu{sup 3+} and LuTaO{sub 4}:Eu{sup 3+} in the presence of fluxes were formed under reduced temperature (900 °C) in contrast to conventional method (GdNbO{sub 4}:Eu{sup 3+}: around 1200 °C; LuTaO{sub 4}:Eu{sup 3+}: around 1500 °C). Scanning electron microscope (SEM) images revealed that well dispersed particles were achieved (granular or rod-like structures). Meanwhile, the photo-luminescent studies demonstrated that both niobate and tantalate are efficient hosts to sensitize europium red emissions. The results indicated that GdNbO{sub 4}:Eu{sup 3+} using NaCl as the flux gave much enhanced red emission whereas LuTaO{sub 4}:Eu{sup 3+} synthesized with the assistance of mixed salts (NaCl–KCl) achieved the best luminescence.

36 MATERIALS SCIENCE↗

Nanometer-scale striped surface terminations on fractured SrTiO{sub 3} surfaces.

Using cross-sectional scanning tunneling microscopy on in situ fractured SrTiO{sub 3}, one of the most commonly used substrates for the growth of complex oxide thin films and superlattices, atomically smooth terraces have been observed on (001) surfaces. Furthermore, it was discovered that fracturing this material at room temperature results in the formation of stripe patterned domains having characteristic widths ({approx}10 to {approx}20 nm) of alternating surface terminations that extend over a long range. Spatial characterization utilizing spectroscopy techniques revealed a strong contrast in the electronic structure of the two domains. Combining these results with topographic data, we are able to assign both TiO{sub 2} and SrO terminations to their respective domains. The results of this experiment reveal that fracturing this material leads to reproducibly flat surfaces that can be characterized at the atomic-scale and suggest that this technique can be utilized for the study of technologically relevant complex oxide interfaces.

36 MATERIALS SCIENCE↗

Anomalous and planar Hall effects in Co 1−x Ho x thin films across the magnetic sublattice compensation temperature

Metallic amorphous ferrimagnets derived from alloying 3d transition metals with 4f-electron rare earths host fascinating effects of compensation between the 3d and 4f magnetic sublattices. Here, a detailed study of the anisotropic magnetoresistance (Δρ xx ), planar Hall effect (ρ xy PHE ), and anomalous Hall effect (ρ xy AHE ) is reported on a series of Co 1−x Ho x thin films over a wide field–temperature (H–T) phase space. Close to the magnetic compensation temperature, the ρ xy AHE –H loops show a double sign reversal and signatures of spin-flop transition at higher fields. The Δρ xx and ρ xy PHE also display strong deviations from the classical angular dependence seen in soft ferromagnets like permalloy as the angle ϕ between in-plane current and magnetic field is scanned from 0 to 2π. It is argued that the non-zero orbital angular momentum of Ho ions in the lattice and stabilization of bubble domains below magnetic saturation may be responsible for such features. Direct imaging of magnetic textures with x-ray photoelectron microscopy shows the formation of stripe domain patterns in the regime of sublattice compensation. Such stripes are likely to transform into magnetic bubbles before full saturation is reached in a large magnetic field.

36 MATERIALS SCIENCE↗

Universality of scanning tunneling microscopy in cuprate superconductors

We consider the problem of local tunneling into cuprate superconductors, combining model-based calculations for the superconducting order parameter with wave function information obtained from first-principles electronic structure. For some time it has been proposed that scanning tunneling microscopy (STM) spectra do not reflect the properties of the superconducting layer in the CuO 2 plane directly beneath the STM tip, but rather a weighted sum of spatially proximate states determined by the details of the tunneling process. These ``filter'' ideas have been countered with the argument that similar conductance patterns have been seen around impurities and charge ordered states in systems with atomically quite different barrier layers. Here we use a recently developed Wannier function-based method to calculate topographies, spectra, conductance maps, and normalized conductance maps close to impurities. We find that it is the local planar Cu d x 2 –y 2 Wannier function, qualitatively similar for many systems, that controls the form of the tunneling spectrum and the spatial patterns near perturbations. Furthermore we explain how, despite the fact that STM observables depend on the materials-specific details of the tunneling process and setup parameters, there is an overall universality in the qualitative features of conductance spectra. In particular, we discuss why STM results on Bi 2 Sr 2 CaCu 2 O 8 (BSCCO) and Ca 2–x Na x CuO 2 Cl 2 (NaCCOC) are essentially identical.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗