Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study

Purpose: To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. Methods: Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), antiscatter properties and sensitivity of the detector with a single pixel readout were measured using a 6-MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero-frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat-panel imager for readout. Results: The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation (f 50 ) of the measured MTF is 0.2 mm –1 at 6 MV, which is comparable to that of video-based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20 x 20 cm 2 field size is approximately 30% lower than that of ionization chamber–based detectors with a comparable QE. The detector noise which includes the x-ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat-panel imager at a dose of less than two LINAC pulses. Thus, the proposed detector is quantum noise limited down to very low doses (~a couple of radiation pulses of the LINAC). A proof-of-concept image has been obtained using a 6-MV beam. Conclusions: This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x-ray imaging. Due to the use of lead as the spacing material, the new detector also has antiscatter property, which will help improve the signal-to-noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially resolvable optical emission spectrometer for analyzing density uniformity of semiconductor process plasma

We proposed a spatially resolved optical emission spectrometer (SROES) for analyzing the uniformity of plasma density for semiconductor processes. To enhance the spatial resolution of the SROES, we constructed a SROES system using a series of lenses, apertures, and pinholes. We calculated the spatial resolution of the SROES for the variation of pinhole size, and our calculated results were in good agreement with the measured spatial variation of the constructed SROES. The performance of the SROES was also verified by detecting the correlation between the distribution of a fluorine radical in inductively coupled plasma etch process and the etch rate of a SiO{sub 2} film on a silicon wafer.

36 MATERIALS SCIENCE↗

Continuous motion scan ptychography: Characterization for increased speed in coherent x-ray imaging

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object’s complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous “fly-scan” mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.

43 PARTICLE ACCELERATORS↗

Projected Urban Morphology of the Los Angeles Area by the Year 2100

This dataset provides projections of urban building morphologies for the Los Angeles urban area at 30-meter spatial resolution. It contains 192 raster files that detail two primary building attributes: building footprint fractions (ranging from 0 to 1) and average building heights (ranging from 0 to 75 meters). The projections account for a wide range of future pathways, covering two Shared Socioeconomic Pathway (SSP) scenarios (SSP3 and SSP5), two population scenarios, two developed land intensification scenarios, and four distinct levels of intensification. The dataset was created using dual Generative Adversarial Networks (GANs) trained on 2015 land cover and building properties from the National Land Cover Database (NLCD) and Model America datasets. Supporting information on the dataset has been described in the LAUrbanAreaMorphologyProjections2100_README.txt file.

Pandey, Bhartendu↗

Forward modeling transient brightenings and microflares around an active region observed with Hi-C

Small-scale flare-like brightenings around active regions are among the smallest and most fundamental of energetic transient events in the corona, providing a testbed for models of heating and active region dynamics. In a previous study, we modeled a large collection of these microflares observed with Hinode/X-Ray Telescope (XRT) using EBTEL and found that they required multiple heating events, but could not distinguish between multiple heating events on a single strand, or multiple strands each experiencing a single heating event. We present here a similar study, but with extreme-ultraviolet data of Active Region 11520 from the High Resolution Coronal Imager (Hi-C) sounding rocket. Hi-C provides an order of magnitude improvement to the spatial resolution of XRT, and a cooler temperature sensitivity, which combine to provide significant improvements to our ability to detect and model microflare activity around active regions. We have found that at the spatial resolution of Hi-C (≈0.''3), the events occur much more frequently than expected (57 events detected, only 1 or 2 expected), and are most likely made from strands of the order of 100 km wide, each of which is impulsively heated with multiple heating events. These findings tend to support bursty reconnection as the cause of the energy release responsible for the brightenings.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanoscale analysis of unstained biological specimens in water without radiation damage using high-resolution frequency transmission electric-field system based on FE-SEM

Scanning electron microscopy (SEM) has been widely used to examine biological specimens of bacteria, viruses and proteins. Until now, atmospheric and/or wet biological specimens have been examined using various atmospheric holders or special equipment involving SEM. Unfortunately, they undergo heavy radiation damage by the direct electron beam. In addition, images of unstained biological samples in water yield poor contrast. We recently developed a new analytical technology involving a frequency transmission electric-field (FTE) method based on thermionic SEM. This method is suitable for high-contrast imaging of unstained biological specimens. Our aim was to optimise the method. Here we describe a high-resolution FTE system based on field-emission SEM; it allows for imaging and nanoscale examination of various biological specimens in water without radiation damage. The spatial resolution is 8 nm, which is higher than 41 nm of the existing FTE system. Our new method can be easily utilised for examination of unstained biological specimens including bacteria, viruses and protein complexes. Furthermore, our high-resolution FTE system can be used for diverse liquid samples across a broad range of scientific fields, e.g. nanoparticles, nanotubes and organic and catalytic materials. - Highlights: • We developed a high-resolution frequency transmission electric-field (FTE) system. • High-resolution FTE system is introduced in the field-emission SEM. • The spatial resolution of high-resolution FTE method is 8 nm. • High-resolution FTE system enables observation of the intact IgM particles in water.

60 APPLIED LIFE SCIENCES↗

Upcoming and Future Missions in the Area of Infrared Astronomy: Spacecraft and Ground-based Observations

The IRIS instrument on the Voyager spacecrafts made major discoveries with regard to the giant planets, their moons and rings and paved the way for future infrared observations for planetary missions within our solar system. The CIRS instrument of Cassini with much greater spectral-spatial resolution and sensitivity than that provided by IRIS is now rapidly approaching the Saturnian system with orbit insertion on July 1, 2004, for which CIRS is expected to provide an order of magnitude advance beyond that provided by IRIS. The Mars program is also presently dominated by infrared observations in the near to mid-infrared spectral bands for missions such as Mars Global Surveyor and its TES instrument and Odyssey with its THEMIS instrument. In the case of Earth science we have such missions as TIMED, which makes infrared observations of the thermosphere using the SABER instrument. With the newly formed New Frontiers Program we have the opportunity for $650M missions such as Kuiper Belt-Pluto Explorer and Jupiter Polar Orbiter with Probes. Under the Flagship line, once per decade, we have the opportunity for $1B missions for which Europa is presently being considered; for this mission infrared measurements could look for hot spots within the maze of cracks and faults on Europa s surface. On Kuiper Belt- Pluto there is an imaging near-IR spectrometer called LEISA. Another mission on the horizon is Titan Orbiter Aerorover Mission (TOAM) for which there is planned a state-of-art version of CIRS called TIRS on the orbiter that will map out the atmospheric composition with unprecedented wavelength coverage and spectral-spatial resolution. This instrument will also provide temperature maps of the surface of Titan to look for hot spots where life may form. On the same mission there will be a descent imager on the Aerorover (i.e., balloon) similar to that provided by LEISA on the Pluto mission to provide compositional-topographical maps of Titan s surface. Other future mission will also be discussed. Improved thermal detectors could have important applications in solar physics, specifically in the detection of far-IR synchrotron emission from energetic electrons in solar flares. For infrared astronomy we have missions like SIRTF and JWST, which will cover the spectral range from near-IR to far-IR in the search and probing of both new and old planetary systems in our galaxy and the measurement of the most distant galaxies of our universe. SIRTF is scheduled to be launched in August 2003, while JWST will be launched next decade. Another mission is TPF, which will use interferometer techniques at infrared wavelengths to search for planetary systems beyond 2010. With regard to ground based telescopes we have, for example, the twin 10 meter Keck telescopes and the IRTF telescope at Mauna Kea. The Keck telescopes are presently using interferometer techniques. Over the next several decades there are plans for 50 meter to 200 meter telescopes providing near-IR to far-IR measurements with the eventual plan to combine all telescopes using interferometer techniques to provide unprecedented spectral-spatial resolution and sensitivity.

Sittler, E. C., Jr.↗

Development of a Daily GRACE Mascon Solution for Terrestrial Water Storage

The Gravity Recovery and Climate Experiment (GRACE) and GRACE-Follow On missions have provided a global history of terrestrial water storage changes since 2002. Traditional GRACE products resolve monthly time-variable gravity at spatial resolutions of 300-500 km, with many recent efforts focusing on regularized mass concentration (mascon) solutions to better resolve signals spatially. However, monthly resolution inhibits the applicability of GRACE to investigations of sub-monthly signals. This study presents a new daily mass change solution estimated as deviations from the NASA Goddard Space Flight Center (GSFC) converged monthly mascon product and quantifies the fundamental trade-off between temporal and spatial resolution in GRACE-only solutions. As an iteration of the GSFC product, this daily solution represents a mixing of monthly information at higher relative spatial resolution with daily information at lower relative spatial resolution, resolving each temporal scale at the best resolution achievable without requiring hydrological model dependencies in the estimation. The resolution of the daily mascons is 300-400 km at high latitudes and 600-1,000 km lower, depending on each daily orbital track and the proximity of each mascon to constraint region boundaries (e.g., coastlines). Through simulations and model comparisons, we demonstrate that daily signals over areas larger than 400,000 km(2) are recoverable, with basins larger than 800,000 km(2) exhibiting strong signal recovery relative to leakage. This analysis establishes baselines for daily signal recovery from GRACE in the context of longer time scale solutions, characterizes leakage inherent in daily GRACE information, and creates new opportunities for applying GRACE to investigations of sub-monthly signals.

M. J. Croteau↗

Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT

Purpose : A method is presented for generating simulated low-dose cone-beam CT (CBCT) preview images from which patient- and task-specific minimum-dose protocols can be confidently selected prospectively in clinical scenarios involving repeat scans. Methods : In clinical scenarios involving a series of CBCT images, the low-dose preview (LDP) method operates upon the first scan to create a projection dataset that accurately simulates the effects of dose reduction in subsequent scans by injecting noise of proper magnitude and correlation, including both quantum and electronic readout noise as important components of image noise in flat-panel detector CBCT. Experiments were conducted to validate the LDP method in both a head phantom and a cadaveric torso by performing CBCT acquisitions spanning a wide dose range (head: 0.8–13.2 mGy, body: 0.8–12.4 mGy) with a prototype mobile C-arm system. After injecting correlated noise to simulate dose reduction, the projections were reconstructed using both conventional filtered backprojection (FBP) and an iterative, model-based image reconstruction method (MBIR). The LDP images were then compared to real CBCT images in terms of noise magnitude, noise-power spectrum (NPS), spatial resolution, contrast, and artifacts. Results : For both FBP and MBIR, the LDP images exhibited accurate levels of spatial resolution and contrast that were unaffected by the correlated noise injection, as expected. Furthermore, the LDP image noise magnitude and NPS were in strong agreement with real CBCT images acquired at the corresponding, reduced dose level across the entire dose range considered. The noise magnitude agreed within 7% for both the head phantom and cadaveric torso, and the NPS showed a similar level of agreement up to the Nyquist frequency. Therefore, the LDP images were highly representative of real image quality across a broad range of dose and reconstruction methods. On the other hand, naïve injection ofuncorrelated noise resulted in strong underestimation of the true noise, which would lead to overly optimistic predictions of dose reduction. Conclusions : Correlated noise injection is essential to accurate simulation of CBCT image quality at reduced dose. With the proposed LDP method, the user can prospectively select patient-specific, minimum-dose protocols (viz., acquisition technique and reconstruction method) suitable to a particular imaging task and to the user's own observer preferences for CBCT scans following the first acquisition. The method could provide dose reduction in common clinical scenarios involving multiple CBCT scans, such as image-guided surgery and radiotherapy.

60 APPLIED LIFE SCIENCES↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging performance comparison between a LaBr{sub 3}:Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera

The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr{sub 3}:Ce scintillator continuous crystal (49x49x5 mm{sup 3}) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14x14x1 mm{sup 3}) with 256x256 square pixels and a pitch of 55 {mu}m, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 {mu}m, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Field of View Soft X-Ray Fourier Transform Holography: Toward Imaging Ultrafast Evolution in a Single Shot

Panoramic full-field imaging is demonstrated by applying spatial multiplexing to Fourier transform holography. Multiple object and reference waves extend the effective field of view for lensless imaging without compromising the spatial resolution. In this way, local regions of interest distributed throughout a sample can be simultaneously imaged with high spatial resolution. A method is proposed for capturing multiple ultrafast images of a sample with a single x-ray pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Imaging of Molecular Functions at Surfaces

The focus of this project is on understanding the nature of intramolecular chemical bonds and intermolecular interactions using a unique technique developed in 2014 under DOE support: the inelastic tunneling probe (itProbe) with the scanning tunneling microscope (STM). By operating the STM at ~0.6 K, high energy resolution of ~0.6 meV is achieved, in combination with the inherent atomic scale spatial resolution of the STM. High energy and spatial resolutions of inelastic electron tunneling spectroscopy (IETS) with the STM enables itProbe to monitor energy shifts in the carbon monoxide (CO) hindered translational vibration as the CO-tip is scanned over an adsorbed molecule. Images are obtained that relate to the two-dimensional slices of the potential energy surface for different heights above the substrate, rendering a tomography of the molecule. Comparison of experimental results to density functional theory (DFT) calculations relates itProbe images to the potential energy surface of the CO-tip probing the potential of the adsorbed molecule. Results from this project provide information on the electronic, vibrational, and structural properties of single molecules, as well as how these properties relate to the reactivity, chemical sensing, self-assembly, and other chemical interactions of higher complexity. This research leads to new insights into the fundamental principles of chemistry that can be applied to the understanding of a broad range of phenomena, such as surface chemistry and catalysis, environmental processes and energy generation, electronic processing and electron transport through molecules as in molecular electronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-232: Micro Diamonds - Determination of Their Lateral Response Function Via Gap-Beam Dose Profiles

Purpose: The aim of this study is the measurement of the lateral response function of microDiamonds by comparison with radiochromic film dose measurement. In this study a TM60019 microDiamond (PTW Freiburg, Germany) and a prototype synthetic diamond detector with smaller sensitive volume were investigated. Methods: Two lead blocks were positioned below the gantry head of an Elekta Synergy accelerator using a gantry mount. Between the blocks two sheets of paper were fixed. The water phantom was positioned below the gantry mount, so that the block to water distance was 20 cm. The gap beam profile was measured at 5 cm water depth by radiochromic EBT3 film and diamond detectors. The film was fixed on a RW3 plate, moved by the step motor system of the phantom and digitized by an Epson 10000XL scanner using the red color channel. Results: The lateral response of the prototype diamond detector is comparable to that of film measurements, i.e. has negligible width. This corresponds to the small detector volume of the prototype detector. In contrast to this the FWHM values of the gap-beam dose profiles measured with the TM60019 detector are somewhat larger, which corresponds to the larger sensitive detector volume. Conclusion: This study has illustrated the high spatial resolution of the diamond detectors. In comparison with filmmeasured narrow-beam dose profiles, the TM60019 has a spatial resolution function of about 2 mm FWHM, whereas the FWHM for the prototype is practically negligible. However due to the low signal caused by the small sensitive volume, measurements with the prototype in clinical routine are a challenge. On the other hand the TM60019 is a good compromise between detector volume and signal output and thus a well suited detector for most clinically relevant small field situations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Imaging of Material Response Following Laser-Induced Breakdown in the Bulk and Surface of Fused Silica

Optical components within high energy laser systems are susceptible to laser-induced material modification when the breakdown threshold is exceeded or damage is initiated by pre-existing impurities or defects. These modifications are the result of exposure to extreme conditions involving the generation of high temperatures and pressures and occur on a volumetric scale of the order of a few cubic microns. The response of the material following localized energy deposition, including the timeline of events and the individual processes involved during this timeline, is still largely unknown. In this work, we investigate the events taking place during the entire timeline in both bulk and surface damage in fused silica using a set of time-resolved microscopy systems. These microscope systems offer up to 1 micron spatial resolution when imaging static or dynamic effects, allowing for imaging of the entire process with adequate temporal and spatial resolution. These systems incorporate various pump-probe geometries designed to optimize the sensitivity for detecting individual aspects of the process such as the propagation of shock waves, near-surface material motion, the speed of ejecta, and material transformations. The experimental results indicate that the material response can be separated into distinct phases, some terminating within a few tens of nanoseconds but some extending up to about 100 microseconds. Overall the results demonstrate that the final characteristics of the modified region depend on the material response to the energy deposition and not on the laser parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generic Sensor Modeling Using Pulse Method

Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.

Helder, Dennis L.↗