Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

47 OTHER INSTRUMENTATION↗

Performance of a size-selected nanocluster deposition facility and in situ characterization of grown films by x-ray photoelectron spectroscopy

We report here on a newly installed gas aggregation type nanocluster deposition unit based on magnetron sputtering ion source with mass selection of the clusters by quadrupole mass filter. The system is ultra high vacuum compatible and is equipped with an in situ X-ray Photoelectron Spectroscopy facility, giving compositional information of the films formed by nanoclusters deposition on a substrate. Detailed descriptions and working of the components of the system are presented. For the characterization of the nanocluster source and associated mass filter for size selected clusters, the dependence of output performance as a function of aggregation length, sputter gas flow and magnetron power of the cluster source have been studied. Copper nanoclusters deposited on Silicon (100) surface and on transmission electron microscope grids are, respectively, studied with scanning electron microscopy and transmission electron microscopy for the morphology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of the Two-Dimensional Power Spectral Density into Specifications for the X-ray Domain -- Problems and Opportunities

An implementation of the two-dimensional statistical scattering theory of Church and Takacs for the prediction of scattering from x-ray mirrors is presented with a graphical user interface. The process of this development has clarified several problems which are of significant interest to the synchrotron community. These problems have been addressed to some extent, for example, for large astronomical telescopes, and at the National Ignition Facility for normal incidence optics, but not in the synchrotron community for grazing incidence optics. Since it is based on the Power Spectral Density (PSD) to provide a description of the deviations from ideal shape of the surface, accurate prediction of the scattering requires an accurate estimation of the PSD. Specifically, the spatial frequency range of measurement must be the correct one for the geometry of use of the optic--including grazing incidence and coherence effects, and the modifications to the PSD of the Optical Transfer Functions (OTF) of the measuring instruments must be removed. A solution for removal of OTF effects has been presented previously, the Binary Pseudo-Random Grating. Typically, the frequency range of a single instrument does not cover the range of interest, requiring the stitching together of PSD estimations. This combination generates its own set of difficulties in two dimensions. Fitting smooth functions to two dimensional PSDs, particularly in the case of spatial non-isotropy of the surface, which is often the case for optics in synchrotron beam lines, can be difficult. The convenient, and physically accurate fractal for one dimension does not readily transfer to two dimensions. Finally, a completely statistical description of scattering must be integrated with a deterministic low spatial frequency component in order to completely model the intensity near the image. An outline for approaching these problems, and our proposed experimental program is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single detector laser-induced fluorescence imager and raman spectral instrument

Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.

Gasda, Patrick J.↗

Note: Fabrication and characterization of molybdenum tips for scanning tunneling microscopy and spectroscopy

We present a method for the preparation of bulk molybdenum tips for Scanning Tunneling Microscopy and Spectroscopy and we assess their potential in performing high resolution imaging and local spectroscopy by measurements on different single crystal surfaces in UHV, namely, Au(111), Si(111)-7 × 7, and titanium oxide 2D ordered nanostructures supported on Au(111). The fabrication method is versatile and can be extended to other metals, e.g., cobalt.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinematic analysis of in situ measurement during chemical mechanical planarization process

Chemical mechanical planarization (CMP) is the most widely used planarization technique in semiconductor manufacturing presently. With the aid of in situ measurement technology, CMP tools can achieve good performance and stable productivity. However, the in situ measurement has remained unexplored from a kinematic standpoint. The available related resources for the kinematic analysis are very limited due to the complexity and technical secret. In this paper, a comprehensive kinematic analysis of in situ measurement is provided, including the analysis model, the measurement trajectory, and the measurement time of each zone of wafer surface during the practical CMP process. In addition, a lot of numerical calculations are performed to study the influences of main parameters on the measurement trajectory and the measurement velocity variation of the probe during the measurement process. All the efforts are expected to improve the in situ measurement system and promote the advancement in CMP control system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and characterization of a laterally-driven inertial micro-switch

A laterally-driven inertial micro-switch was designed and fabricated using surface micromachining technology. The dynamic response process was simulated by ANSYS software, which revealed the vibration process of movable electrode when the proof mass is shocked by acceleration in sensitive direction. The test results of fabricated inertial micro-switches with and without anti-shock beams indicated that the contact process of micro-switch with anti-shock beams is more reliable than the one without anti-shock beams. The test results indicated that three contact signals had been observed in the contact process of the inertial switch without anti-shock beams, and only one contact signal in the inertial switch with anti-shock beams, which demonstrated that the anti-shock beams can effectively constrain the vibration in non-sensitive direction.

36 MATERIALS SCIENCE↗

HI-SCALE Nanoparticle Composition and Precursors Field Campaign Report

From 21 August to 27 September, 2016, during the second Intensive Operational Period (IOP) of the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecoystems (HI-SCALE) field campaign, a suite of instruments were placed in the Guest Instrument Facility (GIF) at the Central Facility of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site in Lamont, Oklahoma. The goal of these measurements was to fully characterize the formation and evolution of atmospheric aerosol particles through measurements of gas-phase precursor and ambient nanoparticle composition. Specifically, we sought to: 1. investigate the role of acid-base chemistry in new-particle growth through measurements of ammonia and amines as well as organic and inorganic acids in both atmospheric nanoparticles and the gas phase; 2. investigate the contribution of other surface-area or volume-controlled processes to nanoparticle formation and growth, such as the uptake of extremely low volatility organic compounds (ELVOCs); 3. evaluate the performance of a new instrument being developed with funding from the DOE Small Business Innovation Research (SBIR) program for measuring gas-phase amines and related compounds; and 4. together with colleagues measuring on the ground and onboard the ARM Gulfstream-1 (G-1) aircraft during HI-SCALE, create a comprehensive data set related to new particle formation and growth that can be used in modeling efforts by the research team as well as DOE collaborators.

54 ENVIRONMENTAL SCIENCES↗

Hydrostatic Microextrusion of Steel and Copper

The paper presents an experimental investigation based on hydrostatic micro extrusion of billets in low carbon steel and commercially pure copper, and the relevant results. The starting billets have a diameter of 0.3 mm and are 5 mm long; a high pressure generator consisting of a manually operated piston screw pump is used to pressurize the fluid up to 4200 bar, the screw pump is connected through a 3-way distribution block to the extrusion die and to a strain gauge high pressure sensor. The sensor has a full scale of 5000 bar and the extrusion pressure is acquired at a sampling rate of 2 kHz by means of an acquisition program written in the LabVIEW environment. Tests have been conducted at room temperature and a lubricant for wire drawing (Chemetall Gardolube DO 338) acts both as the pressurizing fluid and lubricant too. In addition, billets were graphite coated. Different fluid pressures and process durations have been adopted, resulting in different extrusion lengths. The required extrusion pressure is much higher than in non-micro forming operations (this effect is more evident for steel). On the cross section of the extruded parts, hardness and grain size distribution have been measured, the former through Vickers micro hardness (10 g load) tests. In the case of the extrusion of copper, the material behaves as in microdrawing process. In the case of the extrusion of steel, the hardness increases from the core to the surface as in the drawing process, but with lower values. The analysis evidenced the presence of the external layer, but its thickness is about 1/3 of the external layer in the drawn wire and the grains appear smaller than in the layer of the drawn wire. The extruding force required along the extruding direction is higher (22-24 N) than the drawing force along the same direction (12 N): being the material, the reduction ratio, the die sliding length the same in both cases, the higher extrusion force should be caused by a higher tangential friction force and/or a higher redundant work of deformation and/or a different material behaviour. Which is the real mechanism is not clear at present, but surface layer grains in extrusion are more deformed than in wire drawing. For this reason the deformation inhomogeneity increases in extrusion and the material under the highly deformed surface layer should be subjected to lower strains, strain hardening and finally resulting in lower hardness.

36 MATERIALS SCIENCE↗

Thermo-mechanical analysis of ITER first mirrors and its use for the ITER equatorial visible/infrared wide angle viewing system optical design

ITER first mirrors (FMs), as the first components of most ITER optical diagnostics, will be exposed to high plasma radiation flux and neutron load. To reduce the FMs heating and optical surface deformation induced during ITER operation, the use of relevant materials and cooling system are foreseen. The calculations led on different materials and FMs designs and geometries (100 mm and 200 mm) show that the use of CuCrZr and TZM, and a complex integrated cooling system can limit efficiently the FMs heating and reduce their optical surface deformation under plasma radiation flux and neutron load. These investigations were used to evaluate, for the ITER equatorial port visible/infrared wide angle viewing system, the impact of the FMs properties change during operation on the instrument main optical performances. The results obtained are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deposition of dielectric films on silicon using a fore-vacuum plasma electron source

We describe an experiment on the use of a fore-vacuum-pressure, plasma-cathode, electron beam source with current up to 100 mA and beam energy up to 15 keV for deposition of Mg and Al oxide films on Si substrates in an oxygen atmosphere at a pressure of 10 Pa. The metals (Al and Mg) were evaporated and ionized using the electron beam with the formation of a gas-metal beam-plasma. The plasma was deposited on the surface of Si substrates. The elemental composition of the deposited films was analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speckle-based at-wavelength metrology of X-ray mirrors with super accuracy

X-ray active mirrors, such as bimorph and mechanically bendable mirrors, are increasingly being used on beamlines at modern synchrotron source facilities to generate either focused or “tophat” beams. As well as optical tests in the metrology lab, it is becoming increasingly important to optimise and characterise active optics under actual beamline operating conditions. Recently developed X-ray speckle-based at-wavelength metrology technique has shown great potential. The technique has been established and further developed at the Diamond Light Source and is increasingly being used to optimise active mirrors. Details of the X-ray speckle-based at-wavelength metrology technique and an example of its applicability in characterising and optimising a micro-focusing bimorph X-ray mirror are presented. Importantly, an unprecedented angular sensitivity in the range of two nanoradians for measuring the slope error of an optical surface has been demonstrated. Such a super precision metrology technique will be beneficial to the manufacturers of polished mirrors and also in optimization of beam shaping during experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NGEE Arctic Tram: Overview of Tram-mounted Instruments, Co-located Data, Measurement Position, Elevation and Polygon Characterization, Utqiagvik (Barrow), Alaska, 2014-2018

The NGEE-Arctic Tram operated from 2014 - 2018. It was installed on the Barrow Environmental Observatory in Barrow, Alaska in late May of 2014 and operated through mid-November 2014. The subsequent 2015 through 2018 years followed a similar schedule, but with different deployment dates and data gaps, with the goal always to capture the surface dynamics of the snow melt, growing, and freeze-up seasons. This Tram overview dataset has three objectives: (1) provide new data users with a brief description of the Tram system and its research purposes; (2) provide generally useful Tram site characterization details, including measurement position ground surface elevation, characteristics of the Arctic polygonal tundra under the Tram, vegetation community composition (future), and derived image products; and (3) reference all of the data products and archived datasets that were collected with the Tram-mounted sensors and co-located instruments. This dataset contains two csv files, two zipped files, one tif file, and one pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Mimicking Martian dust: An in-vacuum dust deposition system for testing the ultraviolet sensors on the Curiosity rover

We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severely affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of Surface Properties Pre-Rad and Post-Rad of n-in-p Silicon Sensors for Very High Radiation Environment

We are developing n{sup +}-in-p, p-bulk and n-readout, microstrip sensors as a non-inverting radiation hard silicon detector for the ATLAS Tracker Upgrade at the super LHC experiment. The surface radiation damages of the sensors fabricated by Hamamatsu Photonics are characterized on the interstrip capacitance, interstrip resistance and punch-through protection evolution. The detector should provide acceptable strip isolation, exceeding the input impedance of the signal readout chip {approx}1 k{Omega}, after the integrated luminosity of 6 ab{sup -1}, which is twice the luminosity goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a momentum microscope for time resolved band structure imaging

We demonstrate the use of a novel design of a photoelectron microscope in combination to an imaging energy filter for momentum resolved photoelectron detection. Together with a time resolved imaging detector, it is possible to combine spatial, momentum, energy, and time resolution of photoelectrons within the same instrument. The time resolution of this type of energy analyzer can be reduced to below 100 ps. The complete ARUPS pattern of a Cu(111) sample excited with He I, is imaged in parallel and energy resolved up to the photoelectron emission horizon. Excited with a mercury light source (h{nu}=4.9 eV), the Shockley surface state at the energy threshold is clearly imaged in k-space. Electron-electron interactions are observed in momentum space as a correlation hole in two-electron photoemission. With the high transmission and the time resolution of this instrument, possible new measurements are discussed: Time and polarization resolved ARUPS measurements, probing change of bandstructure due to chemical reaction, growth of films, or phase transitions, e.g., melting or martensitic transformations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connecting Galactic Outflows and Star Formation: Inferences from Hα Maps and Absorption-line Spectroscopy at 1 ≲ z ≲ 1.5

We investigate the connection between galactic outflows and star formation using two independent data sets covering a sample of 22 galaxies between 1 ≲ z ≲ 1.5. The Hubble Space Telescope WFC3/G141 grism provides low spectral resolution, high spatial resolution spectroscopy yielding Hα emission-line maps from which we measure the spatial extent and strength of star formation. In the rest-frame near-UV, Keck/DEIMOS observes Fe ii and Mg ii interstellar absorption lines, which provide constraints on the intensity and velocity of the outflows. We compare outflow properties from individual and composite spectra with the star formation rate (SFR) and SFR surface density (Σ{sub SFR}), as well as the stellar mass and specific SFR (sSFR). The Fe ii and Mg ii equivalent widths (EWs) increase with both SFR and Σ{sub SFR} at ≳3σ significance, while the composite spectra show larger Fe ii EWs and outflow velocities in galaxies with higher SFR, Σ{sub SFR}, and sSFR. Absorption-line profiles of the composite spectra further indicate that the differences between subsamples are driven by outflows rather than the interstellar medium. While these results are consistent with those of previous studies, the use of Hα images makes them the most direct test of the relationship between star formation and outflows at z > 1 to date. Future facilities such as the James Webb Space Telescope and the upcoming Extremely Large Telescopes will extend these direct, Hα-based studies to lower masses and SFRs, probing galactic feedback across orders of magnitude in galaxy properties and augmenting the correlations we find here.

47 OTHER INSTRUMENTATION↗