Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

WE-G-204-02: Utility of a Channelized Hotelling Model Observer Over a Large Range of Angiographic Exposure Levels

Purpose: Mathematical model observers provide a figure of merit that simultaneously considers a test object and the contrast, noise, and spatial resolution properties of an imaging system. The purpose of this work was to investigate the utility of a channelized Hotelling model observer (CHO) to assess system performance over a large range of angiographic exposure conditions. Methods: A 4 mm diameter disk shaped, iodine contrast test object was placed on a 20 cm thick Lucite phantom and 1204 image frames were acquired using fixed x-ray beam quality and for several detector target dose (DTD) values in the range 6 to 240 nGy. The CHO was implemented in the spatial domain utilizing 96 Gabor functions as channels. Detectability index (DI) estimates were calculated using the “resubstitution” and “holdout” methods to train the CHO. Also, DI values calculated using discrete subsets of the data were used to estimate a minimally biased DI as might be expected from an infinitely large dataset. The relationship between DI, independently measured CNR, and changes in results expected assuming a quantum limited detector were assessed over the DTD range. Results: CNR measurements demonstrated that the angiography system is not quantum limited due to relatively increasing contamination from electronic noise that reduces CNR for low DTD. Direct comparison of DI versus CNR indicates that the CHO relatively overestimates DI for low DTD and/or underestimates DI values for high DTD. The relative magnitude of the apparent bias error in the DI values was ∼20% over the 40x DTD range investigated. Conclusion: For the angiography system investigated, the CHO can provide a minimally biased figure of merit if implemented over a restricted exposure range. However, bias leads to overestimates of DI for low exposures. This work emphasizes the need to verify CHO model performance during real-world application.

60 APPLIED LIFE SCIENCES↗

Space medicine research publications: 1984-1986

A list is given of the publications of investigators supported by the Biomedical Research and Clinical Medicine Programs of the Space Medicine and Biology Branch, Life Sciences Division, Office of Space Science and Applications. It includes publications entered into the Life Sciences Bibliographic Database by the George Washington University as of December 31, 1986. Publications are organized into the following subject areas: Clinical Medicine, Space Human Factors, Musculoskeletal, Radiation and Environmental Health, Regulatory Physiology, Neuroscience, and Cardiopulmonary.

Wallace, Janice S.↗

F-15B QuietSpike(TradeMark) Aeroservoelastic Flight Test Data Analysis

System identification or mathematical modelling is utilised in the aerospace community for the development of simulation models for robust control law design. These models are often described as linear, time-invariant processes and assumed to be uniform throughout the flight envelope. Nevertheless, it is well known that the underlying process is inherently nonlinear. The reason for utilising a linear approach has been due to the lack of a proper set of tools for the identification of nonlinear systems. Over the past several decades the controls and biomedical communities have made great advances in developing tools for the identification of nonlinear systems. These approaches are robust and readily applicable to aerospace systems. In this paper, we show the application of one such nonlinear system identification technique, structure detection, for the analysis of F-15B QuietSpike(TradeMark) aeroservoelastic flight test data. Structure detection is concerned with the selection of a subset of candidate terms that best describe the observed output. This is a necessary procedure to compute an efficient system description which may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modelling may be of critical importance for the development of robust, parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion which may save significant development time and costs. The objectives of this study are to demonstrate via analysis of F-15B QuietSpike(TradeMark) aeroservoelastic flight test data for several flight conditions (Mach number) that (i) linear models are inefficient for modelling aeroservoelastic data, (ii) nonlinear identification provides a parsimonious model description whilst providing a high percent fit for cross-validated data and (iii) the model structure and parameters vary as the flight condition is altered.

Kukreja, Sunil L.↗

Structure Computation of Quiet Spike[Trademark] Flight-Test Data During Envelope Expansion

System identification or mathematical modeling is used in the aerospace community for development of simulation models for robust control law design. These models are often described as linear time-invariant processes. Nevertheless, it is well known that the underlying process is often nonlinear. The reason for using a linear approach has been due to the lack of a proper set of tools for the identification of nonlinear systems. Over the past several decades, the controls and biomedical communities have made great advances in developing tools for the identification of nonlinear systems. These approaches are robust and readily applicable to aerospace systems. In this paper, we show the application of one such nonlinear system identification technique, structure detection, for the analysis of F-15B Quiet Spike(TradeMark) aeroservoelastic flight-test data. Structure detection is concerned with the selection of a subset of candidate terms that best describe the observed output. This is a necessary procedure to compute an efficient system description that may afford greater insight into the functionality of the system or a simpler controller design. Structure computation as a tool for black-box modeling may be of critical importance for the development of robust parsimonious models for the flight-test community. Moreover, this approach may lead to efficient strategies for rapid envelope expansion, which may save significant development time and costs. The objectives of this study are to demonstrate via analysis of F-15B Quiet Spike aeroservoelastic flight-test data for several flight conditions that 1) linear models are inefficient for modeling aeroservoelastic data, 2) nonlinear identification provides a parsimonious model description while providing a high percent fit for cross-validated data, and 3) the model structure and parameters vary as the flight condition is altered.

Kukreja, Sunil L.↗

Human Centered Hardware Modeling and Collaboration

In order to collaborate engineering designs among NASA Centers and customers, to in clude hardware and human activities from multiple remote locations, live human-centered modeling and collaboration across several sites has been successfully facilitated by Kennedy Space Center. The focus of this paper includes innovative a pproaches to engineering design analyses and training, along with research being conducted to apply new technologies for tracking, immersing, and evaluating humans as well as rocket, vehic le, component, or faci lity hardware utilizing high resolution cameras, motion tracking, ergonomic analysis, biomedical monitoring, wor k instruction integration, head-mounted displays, and other innovative human-system integration modeling, simulation, and collaboration applications.

Stambolian Damon↗

Intercalation and Exfoliation of Hexagonal Boron Nitride

Innovators at NASA's Glenn Research Center have made several breakthroughs in treating hexagonal boron nitride (hBN) nanomaterials, improving their properties to supplant carbon nanotubes in many applications. These advances have hBN nanomaterials set to transform applications such as heat sinks, electrical insulators, lightweight piezoelectric polymers for satellites and unmanned aerial vehicles, ceramic composites for jet engines, biomedical components, and radiation shielding technology.

Hexagonal Boron Nitride↗

Cross-sections for (p,x) reactions on natural chromium for the production of 52,52m,54 Mn radioisotopes

The production of positron-emitting isotopes of manganese is potentially important for developing contrast agents for dual-modality positron emission tomography and magnetic resonance (PET/MR) imaging, as well as for in vivo imaging of the biodistribution and toxicity of manganese. Furthermore, the decay properties of 52 Mn make it an excellent candidate for these applications, and it can easily be produced by bombardment of a chromium target with protons or deuterons from a low-energy biomedical cyclotron. There are several parameters essential to this mode of production—target thickness, beam energy, beam current, and bombardment time—depend heavily on the availability of reliable, reproducible cross-section data. Our paper contributes to the routine production of 52g Mn for biomedical research by contributing experimental cross-sections for natural chromium ( nat Cr) targets for the nat Cr(p,x) 52g Mn reaction, as well as for the production of the radiocontaminants 52m, 54 Mn.

07 ISOTOPE AND RADIATION SOURCES↗

Studies Relating to EVA

In this session, Session JA1, the discussion focuses on the following topics: The Staged Decompression to the Hypobaric Atmosphere as a Prophylactic Measure Against Decompression Sickness During Repetitive EVA; A New Preoxygenation Procedure for Extravehicular Activity (EVA); Metabolic Assessments During Extra-Vehicular Activity; Evaluation of Safety of Hypobaric Decompressions and EVA From Positions of Probabilistic Theory; Fatty Acid Composition of Plasma Lipids and Erythrocyte Membranes During Simulation of Extravehicular Activity; Biomedical Studies Relating to Decompression Stress with Simulated EVA, Overview; The Joint Angle and Muscle Signature (JAMS) System - Current Uses and Future Applications; and Experimental Investigation of Cooperative Human-Robotic Roles in an EVA Work Site.

Source record↗

Compact Microscope Imaging System With Intelligent Controls Improved

The Compact Microscope Imaging System (CMIS) with intelligent controls is a diagnostic microscope analysis tool with intelligent controls for use in space, industrial, medical, and security applications. This compact miniature microscope, which can perform tasks usually reserved for conventional microscopes, has unique advantages in the fields of microscopy, biomedical research, inline process inspection, and space science. Its unique approach integrates a machine vision technique with an instrumentation and control technique that provides intelligence via the use of adaptive neural networks. The CMIS system was developed at the NASA Glenn Research Center specifically for interface detection used for colloid hard spheres experiments; biological cell detection for patch clamping, cell movement, and tracking; and detection of anode and cathode defects for laboratory samples using microscope technology.

McDowell, Mark↗

Teleoperation, Telerobotics

In a general sense, teleoperator devices enable human operators to remotely perform mechanical actions that usually are performed by the human arm and hand.

applications↗

F-15B Quiet Spike(TradeMark) Aeroservoelastic Flight-Test Data Analysis

System identification is utilized in the aerospace community for development of simulation models for robust control law design. These models are often described as linear, time-invariant processes and assumed to be uniform throughout the flight envelope. Nevertheless, it is well known that the underlying process is inherently nonlinear. Over the past several decades the controls and biomedical communities have made great advances in developing tools for the identification of nonlin ear systems. In this report, we show the application of one such nonlinear system identification technique, structure detection, for the an alysis of Quiet Spike(TradeMark)(Gulfstream Aerospace Corporation, Savannah, Georgia) aeroservoelastic flight-test data. Structure detectio n is concerned with the selection of a subset of candidate terms that best describe the observed output. Structure computation as a tool fo r black-box modeling may be of critical importance for the development of robust, parsimonious models for the flight-test community. The ob jectives of this study are to demonstrate via analysis of Quiet Spike(TradeMark) aeroservoelastic flight-test data for several flight conditions that: linear models are inefficient for modelling aeroservoelast ic data, nonlinear identification provides a parsimonious model description whilst providing a high percent fit for cross-validated data an d the model structure and parameters vary as the flight condition is altered.

Kukreja, Sunil L.↗

Electrospun fibers of poly( l ‐lactic acid) containing lovastatin with potential applications in drug delivery

ABSTRACT Lovastatin (Merck's Mevacor) is a statin drug designed to lower cholesterol, and reduce the risk of heart attack and stroke. We use electrospinning to combine the biomedical properties of lovastatin with the advantages of electrospun fibers to prepare a composite biomaterial for lovastatin delivery. Poly( l ‐lactic acid) (PLLA), a biodegradable and biocompatible polymer, was co‐spun with lovastatin. Incorporation of lovastatin at 5 or 10 wt % improved fiber alignment and surface smoothness, and increased fiber diameter. Influence of lovastatin on the phase structure (crystal, mobile amorphous, and rigid amorphous fractions) was investigated using scanning calorimetry and synchrotron X‐ray scattering. Addition of lovastatin resulted in increased crystallinity and reduced mobile amorphous fraction. PLLA fibers were characterized in terms of their drug release kinetics in comparison to PLLA film. High drug entrapment efficiency (ranging from 72% to 82%) and appropriate release profiles were achieved. In vitro drug release studies demonstrated that release occurred in two stages: an initial rapid release over the first day and a slower second stage of release which approached a plateau after 7 days. PLLA fibers have a higher release rate than comparable film. Electrospun biomaterial fibers of PLLA provide a promising new release strategy for delivery of lovastatin. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2017 , 134 , 45287.

Zhu, Yazhe↗

Facile synthesis of QD-anchored composite particles with magnetite cluster cores ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs)

Highlights: ► Triple layered Fe{sub 3}O{sub 4}/SiO{sub 2}/QDs were designed as fluorescent magnetic nanocomposites. ► Magnetite cluster-embedded silica exhibited strong and controllable magnetism. ► Effective conjugation between QDs and magnetic silica occurred at pH3. - Abstract: Magnetism-controlled fluorescent composite particles ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs) were prepared as QD-anchored silica nanoparticles with magnetite cluster cores. First, citrate-capped magnetites (C-Fe{sub 3}O{sub 4}) were prepared by the co-precipitation method and subsequently complexed with 3-aminopropyl-trimethoxysilane (APTMS) at room temperature, consequently leading to the formation of magnetite clusters (A-{sup n}Fe{sub 3}O{sub 4}) with alkoxy terminated interfaces. The sol–gel reaction between A-{sup n}Fe{sub 3}O{sub 4} and tetraethoxysilane (TEOS) produced the core-shell {sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}. The resulting core-shell particles exhibited superparamagnetic properties and controllable magnetism simply by adjusting the thickness of nonmagnetic silica layer. After then, amine-terminated {sup n}Fe{sub 3}O{sub 4}@SiO{sub 2} (NH{sub 2}–{sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}) was conjugated with carboxy quantum dots (QDs) using an EDC coupling agent. The QD conjugation with NH{sub 2}–{sup n}Fe{sub 3}O{sub 4}@SiO{sub 2} of lower pH exhibited the higher photoluminescence (PL) intensity, and the resulting composite particles ({sup n}Fe{sub 3}O{sub 4}@SiO{sub 2}@QDs) can be a useful biomedical agent. This chemical strategy can be further applied to prepare the core-shell magnetic nanostructure with various oxide layers for specific applications.

36 MATERIALS SCIENCE↗

In Situ TEM Study of Radiation Resistance of Metallic Glass–Metal Core–Shell Nanocubes

Radiation damage can cause significantly more surface damage in metallic nanostructures than bulk materials. Structural changes from displacement damage compromise the performance of nanostructures in radiation environments such as nuclear reactors and outer space, or used in radiation therapy for biomedical treatments. As such, it is important to develop strategies to prevent this from occurring if nanostructures are to be incorporated into these applications. In this work, in situ transmission electron microscope ion irradiation was used to investigate whether a metallic glass (MG) coating mitigates sputtering and morphological changes in metallic nanostructures. Dislocation-free Au nanocubes and Au nanocubes coated with a Ni–B MG were bombarded with 2.8 MeV Au 4+ ions. The formation of internal defects in bare Au nanocubes was observed at a fluence of 7.5 × 10 11 ions/cm 2 (0.008 dpa), and morphological changes such as surface roughening, rounding of corners, and formation of nanofilaments began at 4 × 10 12 ions/cm 2 (0.04 dpa). In contrast, the Ni–B MG-coated Au nanocubes (Au@NiB) showed minimal morphological changes at a fluence of 1.9 × 10 13 ions/cm 2 (0.2 dpa). Finally, the MG coating maintains its amorphous nature under all irradiation conditions investigated.

36 MATERIALS SCIENCE↗

Two-Photon Fluorescence Microscopy for Biomedical Research

This viewgraph presentation gives an overview of two-photon microscopy as it applies to biomedical research. The topics include: 1) Overview; 2) Background; 3) Principles of Operation; 4) Advantages Over Confocal; 5) Modes of Operation; and 6) Applications.

Fischer, David↗

Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides

The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N{sup 4}-methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the oxygen retention of the tissue and the significantly greater retention amounting in hypoxic tissue. This hypothesis was confirmed in a series of animal studies. Cu-64 can be used both as an imaging radionuclide and a therapeutic radionuclide. The therapeutic efficacy of Cu-64 ATSM was proven in hamsters bearing the CW39 human colorectal tumors. The administration of Cu-64 ATSM significantly increased the survival time of tumor-bearing animals with no acute toxicity. This copper agent therefore shows promise for radiotherapy. The flow tracer Cu-64 PTSM also demonstrates therapeutic potential by inhibiting cancer cells implanted in animal models. Again, this inhibition occurred at doses which showed no sign of toxicity to the animals. Cu-ATSM was translated to humans, under other support a series of tumors were investigated; these included head and neck cancer, non-small cell lung cancer, cervical cancer and renal cancer. Another radionuclide that was investigated was titanium 45. This radionuclide was successfully produced by radiation of a scandium foil with 15 MeV protons. The titanium 45 was processed and separated from residual scandium by high exchange chomotrophy. Titanium titanocene has been utilized as a therapeutic agent; this compound was prepared and studied in vitro and in vivo. Another project was the preparation of cyclodextrin dimers as a new pre-targeting approach for tumor uptake. Beta-cyclodextradin and two other dimers were synthesized. These dimers were studied for the in vivo application. Work continued on the application of the radionuclide already discussed. Technetium 94m, a positron emitting radionuclide of the widely used 99m Tc nuclide was also prepared. This allows the quantification of the uptake of technetium radiopharmaceuticals. In collaboration with Professor David Piwnica-Worms, technetium 94m, sestamibi was studied in animal models and in a limited number of human subjects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Food and nutrition in space: application to human health

The National Aeronautics and Space Administration begins the new millennium with the hope of expanding human space exploration beyond Earth's orbit. These extended-duration missions (3-5 years) require an in-depth assessment of the critical risks (referred to as "show stoppers") to humans when exposed to the remote environment and reduced gravity conditions for such long periods of time. Food, and the nutrition it provides, is paramount to crew health. For short-duration spaceflight (30 days), the nutrient requirements pertaining to physiological adaptations are likely to be satisfied without significant impact on crew performance or health. However, prolonged exposure to reduced gravity, or microgravity, and isolation may alter human nutrient requirements as well as increase the psychosocial role of food/meals in daily activities. An outline of critical questions and related research needs in the area of food and nutrition has been drafted (1) at NASA JSC with the help of the National Space Biomedical Research Institute (http://www.nsbri.org). The research areas outlined in this plan will directly impact the success of extended-duration human space missions. Findings from this research will have direct applications to human health issues faced here on Earth.

NASA Discipline Regulatory Physiology↗