Fabrication of Flexible Perovskite Solar Cells via Rapid Thermal Annealing

Adaptability, lightweight, and low cost of materials make flexible perovskite solar cells essential for the perovskite technology to breach commercial photovoltaic market. Roll-to-roll manufacturing has great potential for high-throughput perovskite manufacturing; however, conventional annealing methods are not capable of producing flexible perovskite solar cells at scale. Rapid thermal annealing (RTA), a radiative method, is utilized on roll-to-roll lines within many different industries and has shown promising potential for perovskite annealing. Here, we introduce a blade-coated perovskite thin film on flexible ITO-coated PET annealed via RTA that reduces post-deposition processing time from ~150 seconds to ~14 seconds. Performance was not sacrificed for scalability as a perovskite solar cell was produced with a power conversion efficiency (PCE) of 14.58%.

Martin, Blake↗

SU-F-J-221: Adjusted Dose and Its Relation to Radiation Induced Liver Disease During Hepatocellular Carcinoma Radiotherapy

Purpose: Many patients with hepatocellular carcinoma (HCC) had hepatic anatomy variations as a result of inter-fraction deformation during fractionated radiotherapy, which may result in difference from the planned dose. This study aimed to investigate the relationship between adjusted dose and radiation induced liver disease (RILD) in HCC patients receiving three dimensional conformal radiotherapy (3DCRT). Methods: Twenty-three HCC patients received conventional fractionated 3DCRT were enrolled in this retrospective investigation. Among them, seven patients had been diagnosed of RILD post-radiotherapy, including 4 cases of grade 2, 3 cases of grade 3 according to the CTCAE Version 3.0. Daily cone-beam CT (CBCT) scans were acquired throughout the whole treatment course for each patient. To reconstruct the daily dose to a patient considering the interfraction anatomy variations, the planned beams from each patient’s treatment plan were firstly applied to each daily modified CBCT (mCBCT). The daily doses were then summed together with the help of deformable image registration (DIR) to obtain the adjusted dose (Dadjusted) of the patient. Finally, the dose changes in normal liver between planned dose (Dplan) and Dadjusted were evaluated by V20, V30, V40 and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Results: Among the twenty-three patients, the adjusted liver V20, V30, V40 and MDTNL showed significant changes from the planned ones (p<0.05) and averagely increased by 4.1%, 4.7%, 4.5% and 3.9Gy, respectively. And the adjusted liver dose in twenty-one patients (91%) were higher than planned value, the adjusted dose of patients with RILD (6/7) exceeds to the hepatic radiation tolerance. Conclusion: The adjusted dose of all the studied patients significantly differs from planned dose, and mCBCT-based dose reconstruction can aid in evaluating the robustness of the planning solutions, and adjusted dose has the potential to reduce the risk of RILD. The author would like to express great thanks to Lei Xing, Daniel S Kapp and Yong Yang in the Stanford University School of Medicine for their valuable suggestions to this work.This work is supported by NSFC(61471226),China Postdoctoral Science Foundation (2015T80739, 2014M551949) and research funding from Shandong Province(JQ201516).

60 APPLIED LIFE SCIENCES↗

A Radiation-Tolerant, Low-Power Non-Volatile Memory Based on Silicon Nanocrystal Quantum Dots

Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in SiO2 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled in program/erase threshold voltage swing was seen during 100,000 program and erase cycles. Additional near-term goals for this project include extensive testing for radiation hardness and the development of artificial layered tunnel barrier heterostructures which have the potential for large speed enhancements for read/write of nanocrystal memory elements, compared with conventional flash devices. Additional information is contained in the original extended abstract.

Bell, L. D.↗

Quantum well, beam deflecting surface emitting lasers

This invention relates to surface emitting semiconductor lasers (SELs), with integrated 45 deg. beam deflectors. A SEL is formed on a wafer including vertical mirrors and 45 deg. beam deflectors formed in grooves by tilted ion beam etching. A SEL is a lattice matched, or unstrained, AlGaAs/GaAs GRINSCH SQW SEL. An alternate embodiment is shown, in which a SEL is lattice mismatched, strained or pseudomorphic, or InGaAs/AlGaAs GRINSCH SQW SEL which emits radiation at a wavelength to which its substrate is transparent. Both SELs exhibit high output power, low threshold current density, and relatively high efficiency, and each are processing compatible with conventional large scale integration technology. Such SELs may be fabricated in large numbers from single wafers. The novel features of this invention include the use of tilted ion beam etching to form a pair of grooves each including vertical mirrors and 45 deg. beam deflectors. The embodiment provides substantial circuit design flexibility because radiation may be coupled both up and/or down through the substrate.

Kim, Jae H.↗

Comparison of sigma(o) obtained from the conventional definition with sigma(o) appearing in the radar equation for randomly rough surfaces

A comparison is made of the radar cross section of rough surface calculated in one case from the conventional definition and obtained in the second case directly from the radar equation. The validity of the conventional definition representing the cross section appearing in the radar equation is determined. The analysis is executed in the special case of perfectly conducting, randomly corrugated surfaces in the physical optics limit. The radar equation is obtained by solving for the radiation scattered from an arbitrary source back to a colocated antenna. The signal out of the receiving antenna is computed from this solution and the result put into a form recognizeable as the radar equation. The conventional definition is obtained by solving a similar problem but for backscatter from an incident planewave. It is shown that these tow forms for sigma are the same if the observer is far enough from the surface.

Levine, D. M.↗

Recent evolution of risk analyses in atomic bomb survivor studies: new methods and applications

Abstract Several decades ago a dramatic leap forward occurred in the development and application of statistical methods for modeling radiation risk at the Radiation Effects Research Foundation (RERF). Poisson regression analysis for grouped person-year cohort data and the linear excess relative risk model were introduced, and subsequently a devoted software system, Epicure® (https://www.hirosoft.com), was developed by researchers at RERF and at the U.S. National Cancer Institute. Numerous advancements in understanding radiation effects on humans were made possible with these methods, which are still the state-of-the-art for risk assessment at RERF and have remained part of the standard toolbox for radiation—and other environmental—epidemiological studies worldwide. Nevertheless, as our understanding of radiation risk has increased, so have the breadth and depth of questions that require answers based on emerging data that are not amenable to these conventional methods. This overview briefly recounts the conventional methods and then describes our recent diversification into the use or development of new statistical approaches to meet the challenges of burgeoning biological data and emerging mechanistic information. We briefly discuss the development and application of new methods, current and planned, that are part of the RERF Statistics Department’s role in supporting institution-wide research, especially in our collaborations involving the Life Span Study, Adult Health Study, and First-generation Offspring Clinical Study. Some approaches to modeling and assessing radiation risk with newer methods mentioned herein have already been published, while some are still in development or are only beginning at the proposal stage.

Oncology↗

Design and evaluation of a rotating variable conductance heat pipe system

Analysis of the Dynamics Explorer high orbiter spacecraft showed that the proposed louver system, along with existing radiator heat rejection areas on the S/C surface were insufficient to safely control the S/C's thermal excursions caused by highly varying internal power levels and solar input angles. A variable conductance heat pipe system in conjunction with a conventional radial heat pipe system was designed, built, tested, and shown to resolve this problem. The conventional pipes, radial, spinning at 10 rpm were required to carry 35 watts each after experiencing despin from 80 rpm. The VCHPs attached to the radial pipes at the S/C perimeter distributed the excess energy via a finned radiator attached around the S/C's center.

Marshburn, J. P.↗

Remote sensor response study in the regime of the microwave radiation-induced magnetoresistance oscillations

A concurrent remote sensing and magneto-transport study of the microwave excited two dimensional electron system (2DES) at liquid helium temperatures has been carried out using a carbon detector to remotely sense the microwave activity of the 2D electron system in the GaAs/AlGaAs heterostructure during conventional magneto-transport measurements. Various correlations are observed and reported between the oscillatory magnetotransport and the remotely sensed reflection. In addition, the oscillatory remotely sensed signal is shown to exhibit a power law type variation in its amplitude, similar to the radiation-induced magnetoresistance oscillations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Size and density distribution of very small dust grains in the Barnard 5 cloud

The effects of the temperature fluctuations in small graphite grains on the energy spectrum and the IR surface brightness of an isolated dust cloud heated externally by the interstellar radiation field were investigated using a series of models based on a radiation transport computer code. This code treats self-consistently the thermal coupling between the transient heating of very small dust grains and the equilibrium heating of conventional large grains. The model results were compared with the IRAS observations of the Barnard 5 (B5) cloud, showing that the 25-micron emission of the cloud must be produced by small grains with a 6-10 A radius, which also contribute about 50 percent to the observed 12-micron emission. The remaining 12 micron flux may be produced by the polycyclic aromatic hydrocarbons. The 60-and 100-micron radiation is dominated by emission from large grains heated under equilibrium conditions.

Lis, Dariusz C.↗

SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

60 APPLIED LIFE SCIENCES↗

Association of human T-cell leukemia virus type 1 with prevalent rheumatoid arthritis among atomic bomb survivors: A cross-sectional study

Previous studies have suggested that human T-cell leukemia virus type 1 (HTLV-1) might act as a pathogen in rheumatoid arthritis (RA), but epidemiological evidence of an association is scarce. We measured anti-HTLV-1 antibodies among Nagasaki atomic bomb survivors to determine whether HTLV-1 is related to RA and whether radiation exposure is associated with HTLV-1 and RA prevalence. This is a cross-sectional study among atomic bomb survivors who participated in biennial health examinations from 2006 to 2010. Serum levels of anti-HTLV-1 antibodies were measured using a chemiluminescent enzyme immunoassay and confirmed by Western blotting. Association between HTLV-1 and RA was analyzed by a logistic regression model. Of 2091 participants (women 61.5%; median age, 73 years), 215 (10.3%) had anti-HTLV-1 antibodies. HTLV-1 prevalence was higher among women (13.1% vs 5.8%; P<.001). Twenty-two participants (1.1%) were diagnosed with RA. HTLV-1 prevalence among RA participants was significantly higher than that among non-RA participants (27.3% vs 10.1%; P=.020). After adjustment for age, sex, and hepatitis C virus infection, HTLV-1 was significantly associated with prevalent RA (odds ratio, 2.89; 95% confidence interval, 1.06, 7.03). There was no association between radiation dose and either the prevalence of HTLV-1 or RA. This study, among a well-defined group of atomic bomb survivors, suggests that HTLV-1 is associated with RA. Abbreviations: AHS = Adult Health Study, ATL/ATLL = adult T cell leukemia/lymphoma, bioDMARDs = biological disease modifying antirheumatic drugs, CCP = cyclic citrullinated peptide, CI = confidence interval, CLEIA = chemiluminescent enzyme immunoassay, CRP = C-reactive protein, csDMARDs = conventional synthetic disease modifying antirheumatic drugs, Gy = gray, HCV = hepatitis C virus, HTLV-1 = human T-cell leukemia virus type 1, IF = immunofluorescent, RA = rheumatoid arthritis, RERF = Radiation Effects Research Foundation, RF = rheumatoid factor, SS = Sjogren syndrome.

59 BASIC BIOLOGICAL SCIENCES↗

KiT-RT: An Extendable Framework for Radiative Transfer and Therapy

Here, in this article, we present Kinetic Transport Solver for Radiation Therapy (KiT-RT), an open-source C++-based framework for solving kinetic equations in therapy applications available at https://github.com/CSMMLab/KiT-RT . This software framework aims to provide a collection of classical deterministic solvers for unstructured meshes that allow for easy extendability. Therefore, KiT-RT is a convenient base to test new numerical methods in various applications and compare them against conventional solvers. The implementation includes spherical harmonics, minimal entropy, neural minimal entropy, and discrete ordinates methods. Solution characteristics and efficiency are presented through several test cases ranging from radiation transport to electron radiation therapy. Due to the variety of included numerical methods and easy extendability, the presented open-source code is attractive for both developers, who want a basis to build their numerical solvers, and users or application engineers, who want to gain experimental insights without directly interfering with the codebase.

97 MATHEMATICS AND COMPUTING↗

Radiation Damage Studies on Titanium Alloys as High Intensity Proton Accelerator Beam Window Materials

A high-strength dual a+ß phase titanium alloy Ti–6Al–4V is utilized as a material for beam windows in several accelerator target facilities. However, relatively little is known about how material properties of this alloy are affected by high-intensity proton beam irradiation. With plans to upgrade neutrino facilities at J-PARC and Fermilab to over 1 MW beam power, the radiation damage in the window material will reach a few displacements per atom (dpa) per year, significantly above the ~0.3 dpa level of existing data. The international RaDIATE collaboration, Radiation Damage In Accelerator Target Environments, has conducted a high intensity proton beam irradiation of various target and window material specimens at Brookhaven Linac Isotope Producer (BLIP) facility, including a variety of titanium alloys. Post-Irradiation Examination (PIE) of the specimens in the 1st capsule, irradiated at up to 0.25 dpa, is in progress. Tensile tests in a hot cell at Pacific Northwest National Laboratory (PNNL) exhibited a clear signature of radiation hardening and loss of ductility for Ti–6Al–4V, while Ti–3Al–2.5V, with less ß phase, exhibited less severe hardening. Microstructural investigations will follow to study the cause of the difference in tensile behavior between these alloys. High-cycle fatigue (HCF) performance is critical to the lifetime estimation of beam windows exposed to a periodic thermal stress from a pulsed proton beam. The first HCF data on irradiated titanium alloys are to be obtained by a conventional bend fatigue test at Fermilab and by an ultrasonic mesoscale fatigue test at Culham Laboratory. Specimens in the 2nd capsule, irradiated at up to ~1 dpa, cover typical titanium alloy grades, including possible radiation-resistant candidates. These systematic studies on the effects of radiation damage of titanium alloy materials are intended to enable us not only to predict realistic lifetimes of current beam windows made of Ti–6Al–4V, but also to extend the lifetime by choosing a more radiation and thermal shock tolerant alloy with a preferable heat treatment, or even by developing new materials.

Titanium Alloy, Beam Window, Proton Beam, Radiatio↗

A New Approach for Short-Term Solar Radiation Forecasting Using the Estimation of Cloud Fraction and Cloud Albedo

Solar generation is an increasing part of the energy portfolio in the United States. An accurate forecast of the available solar resource and power is essential to managing the electric grid, market operations, and reducing the cost of solar energy. High-frequency forecasts of solar radiation in intra-hour horizons is important for real-time electric power system energy management, especially at the distribution level. Conventional Numerical Weather Prediction models perform poorly in intra-hour, high-frequency forecasts because of the limits on real-time computing, spatial resolution, and infrequent availability of observations. Although a number of alternative technologies, e.g., time-series analysis and machine learning, have been used to fill this gap, the smart persistence model is among the top-performing models in short-term forecasting and therefore often serves as the baseline to evaluate other forecasting models. Although the smart persistence model often serves as the baseline model in these intra-hour forecasts, obvious uncertainties exist in the current smart persistence model: (1) clear-sky index does not respond to the variation of the solar incident angle when cloud conditions are persistent within the forecast horizon, and (2) cloud coverage is inherently persistent though it is constrained by cloud advection. In this study, we developed a Physics-Based Smart Persistence Model for Intra-Hour Solar Forecasting (PSPI) that integrates cloudy property estimation, a radiative transfer model, and cloud fraction forecasts to improve the performance of the smart persistence model. Compared to the smart persistence model, PSPI does not require additional observations of various atmospheric parameters past global horizontal irradiance, but it is customizable because additional observations, if available, can be ingested to further improve the forecast. Our results show that the PSPI outperforms the persistence and smart persistence model on 5-minute, 15-minute, and 30-minute forecast horizons. The software package of PSPI is flexible to users' needs and provides low computational time to run at site-specific locations across the continental United States.

14 SOLAR ENERGY↗

Ultrafast x-ray photoelectron spectroscopy in the microsecond time domain

We introduce a new approach for ultrafast in situ high-resolution X-ray photoelectron spectroscopy (XPS) to study surface processes and reaction kinetics on the microsecond timescale. The main idea is to follow the intensity at a fixed binding energy using a commercial 7 channeltron electron analyzer with a modified signal processing setup. This concept allows for flexible switching between measuring conventional XP spectra and ultrafast XPS. The experimental modifications are described in detail. As an example, we present measurements for the adsorption and desorption of CO on Pt(111), performed at the synchrotron radiation facility BESSY II, with a time resolution of 500 μs. Due to the ultrafast measurements, we are able to follow adsorption and desorption in situ at pressures of 2 × 10{sup −6} mbar and temperatures up to 500 K. The data are consistently analyzed using a simple model in line with data obtained with conventional fast XPS at temperatures below 460 K. Technically, our new approach allows measurement on even shorter timescales, down to 20 μs.

36 MATERIALS SCIENCE↗

Shear viscosity and thermal conductivity of nuclear 'pasta'

We calculate the shear viscosity {eta} and thermal conductivity {kappa} of a nuclear pasta phase in neutron star crusts. This involves complex nonspherical shapes. We use semiclassical molecular dynamics simulations involving 40, 000 to 100, 000 nucleons. The viscosity {eta} can be simply expressed in terms of the height Z* and width {delta}q of the peak in the static structure factor S{sub p}(q). We find that {eta} increases somewhat, compared to a lower density phase involving spherical nuclei, because Z* decreases from form factor and ion screening effects. However, we do not find a dramatic increase in {eta} from nonspherical shapes, as may occur in conventional complex fluids.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface-peaked effective mass in the nuclear energy density functional and its influence on single-particle spectra

Calculations for infinite nuclear matter with realistic nucleon-nucleon interactions suggest that the isoscalar effective mass of a nucleon at the saturation density m*/m equals 0.8+-0.1. This result is at variance with empirical data on the level density in finite nuclei, which are consistent with m*/mapprox =1. Ma and Wambach suggested that these two contradicting results may be reconciled within a single theoretical framework by assuming a radial-dependent effective mass, peaked at the nuclear surface. The aim of this exploratory work is to investigate this idea within the density functional theory by using a Skyrme-type local functional enriched with new terms, tau(nablarho){sup 2} and tau(drho/dr), where tau and rho denote the kinetic and particle densities, respectively. We show that each of these terms can give rise to a surface peak in the effective mass, but of a limited height. We investigate the influence of the radial profile of the effective mass on the spin-orbit splittings and centroids. In particular, we demonstrate that the tau(drho/dr) term quenches the 1f{sub 5/2}-1f{sub 7/2} splitting in {sup 40}Ca, which is strongly overestimated within conventional Skyrme parametrizations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inclusive neutrino scattering off the deuteron at low energies in chiral effective field theory

Cross sections for inclusive neutrino scattering off deuteron induced by neutral and charge-changing weak currents are calculated from threshold up to 150 MeV energies in a chiral effective field theory including high orders in the power counting. The contributions beyond leading order (LO) in the weak current are found to be small, and increase the cross sections obtained with the LO transition operators by a couple of percent over the whole energy range (0--150) MeV. Furthermore, the cutoff dependence is negligible, and the predicted cross sections are within ~2% of, albeit consistently larger than, corresponding predictions obtained in conventional meson-exchange frameworks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗