Search NASA⌕ Search

SEARCH · Search NASA

Results for “Counting statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

The Analysis of the Patterns of Radiation-Induced DNA Damage Foci by a Stochastic Monte Carlo Model of DNA Double Strand Breaks Induction by Heavy Ions and Image Segmentation Software

To create a generalized mechanistic model of DNA damage in human cells that will generate analytical and image data corresponding to experimentally observed DNA damage foci and will help to improve the experimental foci yields by simulating spatial foci patterns and resolving problems with quantitative image analysis. Material and Methods: The analysis of patterns of RIFs (radiation-induced foci) produced by low- and high-LET (linear energy transfer) radiation was conducted by using a Monte Carlo model that combines the heavy ion track structure with characteristics of the human genome on the level of chromosomes. The foci patterns were also simulated in the maximum projection plane for flat nuclei. Some data analysis was done with the help of image segmentation software that identifies individual classes of RIFs and colocolized RIFs, which is of importance to some experimental assays that assign DNA damage a dual phosphorescent signal. Results: The model predicts the spatial and genomic distributions of DNA DSBs (double strand breaks) and associated RIFs in a human cell nucleus for a particular dose of either low- or high-LET radiation. We used the model to do analyses for different irradiation scenarios. In the beam-parallel-to-the-disk-of-a-flattened-nucleus scenario we found that the foci appeared to be merged due to their high density, while, in the perpendicular-beam scenario, the foci appeared as one bright spot per hit. The statistics and spatial distribution of regions of densely arranged foci, termed DNA foci chains, were predicted numerically using this model. Another analysis was done to evaluate the number of ion hits per nucleus, which were visible from streaks of closely located foci. In another analysis, our image segmentaiton software determined foci yields directly from images with single-class or colocolized foci. Conclusions: We showed that DSB clustering needs to be taken into account to determine the true DNA damage foci yield, which helps to determine the DSB yield. Using the model analysis, a researcher can refine the DSB yield per nucleus per particle. We showed that purely geometric artifacts, present in the experimental images, can be analytically resolved with the model, and that the quantization of track hits and DSB yields can be provided to the experimentalists who use enumeration of radiation-induced foci in immunofluorescence experiments using proteins that detect DNA damage. An automated image segmentaiton software can prove useful in a faster and more precise object counting for colocolized foci images.

Ponomarev, Artem↗

Descriptors of water aggregation

For this work, we rely on a total of 23 (cluster size, 8 structural, and 14 connectivity) descriptors to investigate structural patterns and connectivity motifs associated with water cluster aggregation. In addition to the cluster size n (number of molecules), the 8 structural descriptors can be further categorized into (i) one-body (intramolecular): covalent OH bond length (r OH ) and HOH bond angle (θ HOH ), (ii) two-body: OO distance (r OO ), OHO angle (θ OHO ), and HOOX dihedral angle ($\phi$ HOOX ), where X lies on the bisector of the HOH angle, (iii) three-body: OOO angle (θ OOO ), and (iv) many-body: modified tetrahedral order parameter (q) to account for two-, three-, four-, five-coordinated molecules (q m , m = 2, 3, 4, 5) and radius of gyration (R g ). The 14 connectivity descriptors are all many-body in nature and consist of the AD, AAD, ADD, AADD, AAAD, AAADD adjacencies [number of hydrogen bonds accepted (A) and donated (D) by each water molecule], Wiener index, Average Shortest Path Length, hydrogen bond saturation (% HB), and number of non-short-circuited three-membered cycles, four-membered cycles, five-membered cycles, six-membered cycles, and seven-membered cycles. We mined a previously reported database of 4 948 959 water cluster minima for (H 2 O) n , n = 3–25 to analyze the evolution and correlation of these descriptors for the clusters within 5 kcal/mol of the putative minima. It was found that r OH and % HB correlated strongly with cluster size n, which was identified as the strongest predictor of energetic stability. Marked changes in the adjacencies and cycle count were observed, lending insight into changes in the hydrogen bond network upon aggregation. A Principal Component Analysis (PCA) was employed to identify descriptor dependencies and group clusters into specific structural patterns across different cluster sizes. The results of this study inform our understanding of how water clusters evolve in size and what appropriate descriptors of their structural and connectivity patterns are with respect to system size, stability, and similarity. The approach described in this study is general and can be easily extended to other hydrogen-bonded systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyper Spectral Anomaly Detection

The HSA is a statistics based anomaly detection model. The model performs unsupervised anomaly detection, based on a datapoint's density and similarity within a dataset. Density and similarity data are encoded into an affinity matrix. The affinity matrix is evolved to summarize the data's structure on greater topographical scales within the data's function space. The set of evolved affinity matrices and an anomaly score vector are passed to a user defined penalized objective function. The penalized objective function of anomaly scores is then minimized. Data points where the absolute value of the z-scores of anomaly scores greater than a specified threshold are predicted as anomalies. A novel multi-filter feature has also been implemented. To reduce false positive rates, the multi-filter records the indexes of the HSA predictions. A new dataset and data loader are instantiated consisting of all the initial HSA predictions and non-anomalous data points in a 10% and 90% split respectively. The HSA is then run through this data set and a count of number of times a data point is predicted is kept. In this way the initial predictions may be compared with data spanning the entire dataset. After the multi-filter is complete, all datapoints will have an associated anomaly score, as well as a multi-filter prediction count to further filter the anomalous predictions.

Rogers, DempseyD [Idaho National Laboratory (INL),↗

THE OPTICAL COLORS OF GIANT ELLIPTICAL GALAXIES AND THEIR METAL-RICH GLOBULAR CLUSTERS INDICATE A BOTTOM-HEAVY INITIAL MASS FUNCTION

We report a systematic and statistically significant offset between the optical (g - z or B - I) colors of seven massive elliptical galaxies and the mean colors of their associated massive metal-rich globular clusters (GCs) in the sense that the parent galaxies are redder by {approx}0.12-0.20 mag at a given galactocentric distance. However, spectroscopic indices in the blue indicate that the luminosity-weighted ages and metallicities of such galaxies are equal to that of their averaged massive metal-rich GCs at a given galactocentric distance, to within small uncertainties. The observed color differences between the red GC systems and their parent galaxies cannot be explained by the presence of multiple stellar generations in massive metal-rich GCs, as the impact of the latter to the populations' integrated g - z or B - I colors is found to be negligible. However, we show that this paradox can be explained if the stellar initial mass function (IMF) in these massive elliptical galaxies was significantly steeper at subsolar masses than canonical IMFs derived from star counts in the solar neighborhood, with the GC colors having become bluer due to dynamical evolution, causing a significant flattening of the stellar MF of the average surviving GC.

79 ASTRONOMY AND ASTROPHYSICS↗

Euratom Fast Collar (EFC) Calibration Report

Neutron collars are used by international inspectorates to determine the amount of 235U in fresh LWR fuel assemblies. Standard neutron collars can operate in two modes: “fast” and “thermal”. In fast mode (using cadmium liners), thermal neutron are excluded from the assembly and the measurement results are not very sensitive to the presence of neutron poison loaded pins. In thermal mode, the thermal neutrons are affected by the presence of poison rods leading to significant effect, requiring corrections. These corrections depend on the declaration of the operator, reducing the independence of the inspectors’ measurements. The thermal mode signal is much higher than the fast mode signal and can give statistically acceptable results in ~600 seconds compared with ~1 hr for the fast mode. This report describes the calibration of a new fast neutron collar designed to use fast mode to reduce the effect of poison pins on verification measurements and with increased efficiency to reduce the measurement times to those normally used on inspection. The work was done in cooperation with the safeguards division of the European Commission and so the new collar is named the Euratom Fast Collar (EFC). The motivation and design work is presented in reference 2. The Monte Carlo simulations presented in reference 2 cover a larger parameter range than can be experimentally measured with the mock up assembly and so we base the performance on the simulation results, benchmarked to the measurements. The work presented here follows that of the “bible” of LWR fuel assembly measurements and uses the same mock-up assembly, with the same enriched, depleted and gadolinium poisoned fuel rods as were used in that work. Reference 1 describes how the measured count rate of the detector is corrected for AmLi source strength, electronic stability, efficiency, poison rods effects and heavy metal effects as well as other perturbing factors. These will be discussed below. INCC is the normal software that is used to collect and analyze neutron collar data. The results of this work have been formulated to fit into this existing INCC data analysis framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compositional analysis of projectile residues on LDEF instrument AO187-1

Impact craters greater than 30 microns and associated projectile residues were analyzed by Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Analysis (EDXA). Objectives were to analyze a statistically significant number of projectiles to evaluate their chemical variability and possible clustering into discrete particle types. Bay A11 exposed six collector surfaces of anodized 1100-T4 (greater than 99 percent pure) aluminum sheets, 0.32 cm thick, yielding an exposed surface area of 1.1 sq. m. Four of the six panels have been retained at JSC, and were optically scanned, one (A11E00E) was prepared for SEM/EDX analysis. Bay A03 was occupied by high purity (99.99 percent) gold sheets, 0.5 mm thick, yielding an exposed surface area of 0.85 sq. m. Sample processing included the optical scanning (6X), labeling, and dislodging (by a punch-die device) of each individual impact greater than 75 microns for the aluminum and 30 microns for the gold. The 209 craters were dislodged form A11E00E, having crater diameters up to 3500 microns. Optical examination of the gold surfaces detected 238 craters, 198 of which were retained at JSC and analyzed via SEM/EDX. The analytical procedures included maximizing the geometric efficiency (take-off angles), using relatively long count times (500-1000 sec) and sufficiently high accelerating currents (25-30Kev). Despite diligent examination, a large number of craters did not exhibit measurable signals above background. Detectable resides were classified as either micrometeoritic or as man-made debris.

Bernhard, Ronald P.↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

Livingston, R. A.↗

Effects of hypergravity on immunologic function

The purpose of this study was to compare the effects of hypergravity exposure (2g) with those of exposure to space flight in the Cosmos 2044 flight. To do so, rats were centrifuged continuously for 14 days. Two different experiments were carried out on tissue obtained from the centrifuged rats. In the first experiment, rat bone marrow cells were examined for their response to recombinant murine colony stimulating factor-granulocyte/monocyte (GM-CSF). In the second experiment, rat spleen and bone marrow cells were stained in with a variety of antibodies directed against cell surface antigenic markers. These cells were preserved and analyzed on a flow cytometer. The results of the studies indicated that bone marrow cells from centrifuged rats showed no significant change in response to GM-CSF as compared to bone marrow cells from control rats. Spleen cells from flown rats showed some statistically significant changes in leukocytes subset distribution, but no differences that appeared to be of biological significance. These results indicate that hypergravity did not greatly affect the same immunological parameters affected by space flight in the Cosmos 2044 mission.

NASA Program Flight↗

Evaluation of portable air samplers for monitoring airborne culturable bacteria

Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

NASA Center JSC↗

Approximate Bayesian Computation applied to the Diffuse Gamma-Ray Sky

ABSTRACT Many sources contribute to the diffuse gamma-ray background (DGRB), including star forming galaxies, active galactic nuclei, and cosmic ray interactions in the Milky Way. Exotic sources, such as dark matter annihilation, may also make some contribution. The photon counts-in-pixels distribution is a powerful tool for analysing the DGRB and determining the relative contributions of different sources. However, including photon energy information in a likelihood analysis of the counts-in-pixels distribution quickly becomes computationally intractable as the number of source types and energy bins increase. Here, we apply the likelihood-free method of approximate Bayesian computation (ABC) to the problem. We consider a mock analysis that includes contributions from dark matter annihilation in Galactic subhaloes as well as astrophysical backgrounds. We show that our results using ABC are consistent with the exact likelihood when energy information is discarded, and that significantly tighter parameter constraints can be obtained with ABC when energy information is included. ABC presents a powerful tool for analysing the DGRB and understanding its varied origins.

79 ASTRONOMY AND ASTROPHYSICS↗

Targeted coherent search for gravitational waves from compact binary coalescences

We introduce a method for conducting a targeted, coherent search for compact binary coalescences. The search is tailored to be used as a follow-up to electromagnetic transients such as gamma-ray bursts. We derive the coherent search statistic for Gaussian detector noise and discuss the benefits of a coherent, multidetector search over coincidence methods. To mitigate the effects of nonstationary data, we introduce a number of signal consistency tests, including the null signal-to-noise ratio, amplitude consistency, and several {chi}{sup 2} tests. We demonstrate the search performance on Gaussian noise and on data from LIGO's fourth science run and verify that the signal consistency tests are capable of removing the majority of noise transients, giving the search an efficiency comparable to that achieved in Gaussian noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian chain graph models to characterize microbe-environment dynamics

Microbiome data require statistical models that can simultaneously decode microbes' reaction to the environment and interactions among microbes. While a multiresponse linear regression model seems like a straight-forward solution, we argue that treating it as a graphical model is problematic given that the regression coefficient matrix does not encode the conditional dependence structure between response and predictor nodes. This observation is especially important in biological settings when we have prior knowledge on the edges from specific experimental interventions that can only be properly encoded under a conditional dependence model. Here, we propose a chain graph model with two sets of nodes (predictors and responses) whose solution yields a graph with edges that indeed represent conditional dependence, thus agreeing with the experimenter's intuition on the average behavior of nodes under treatment. The solution to our model is sparse via the Bayesian linear regression (LASSO). In addition, we propose an adaptive extension so that different shrinkages can be applied to different edges to incorporate edge-specific prior knowledge. Our model is computationally inexpensive through an efficient Gibbs sampling algorithm and can account for binary, counting, and compositional responses via an appropriate hierarchical structure. We test the performance of our model in a variety of simulated datasets, thereby showing superior performance to state-of-the-art approaches. We further apply our model to human gut and soil microbial compositional datasets, and we highlight that CG-LASSO can estimate biologically meaningful network structures in the data.

compositional data↗

Accurate small and wide angle x-ray scattering profiles from atomic models of proteins and nucleic acids

A new method is introduced to compute X-ray solution scattering profiles from atomic models of macromolecules. The three-dimensional version of the Reference Interaction Site Model (RISM) from liquid-state statistical mechanics is employed to compute the solvent distribution around the solute, including both water and ions. X-ray scattering profiles are computed from this distribution together with the solute geometry. We describe an efficient procedure for performing this calculation employing a Lebedev grid for the angular averaging. The intensity profiles (which involve no adjustable parameters) match experiment and molecular dynamics simulations up to wide angle for two proteins (lysozyme and myoglobin) in water, as well as the small-angle profiles for a dozen biomolecules taken from the BioIsis.net database. The RISM model is especially well-suited for studies of nucleic acids in salt solution. Use of fiber-diffraction models for the structure of duplex DNA in solution yields close agreement with the observed scattering profiles in both the small and wide angle scattering (SAXS and WAXS) regimes. In addition, computed profiles of anomalous SAXS signals (for Rb{sup +} and Sr{sup 2+}) emphasize the ionic contribution to scattering and are in reasonable agreement with experiment. In cases where an absolute calibration of the experimental data at q = 0 is available, one can extract a count of the excess number of waters and ions; computed values depend on the closure that is assumed in the solution of the Ornstein–Zernike equations, with results from the Kovalenko–Hirata closure being closest to experiment for the cases studied here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report on 240 Am(n,x) surrogate cross section test measurement

The main goal of the test measurement was to determine the feasibility of the 243 Am(p,t) reaction as a surrogate for 240 Am(n,f). No data cross section data exists for neutron induced reactions on 240 Am; the half-life of this isotope is only 2.1 days making direct measurements difficult, if not impossible. The 48-hour experiment was conducted using the STARS/LIBERACE experimental facility located at the 88 Inch Cyclotron at Lawrence Berkeley National Laboratory in August 2011. A description of the experiment and results is given. The beam energy was initially chosen to be 39 MeV in order to measure an equivalent neutron energy range from 0 to 20 MeV. However, the proton beam was not stopped in the farady cup and the beam was deposited in the surrounding shielding material. The shielding material was not conductive, and a beam current, needed for proper tuning of the beam as well as experimental monitoring, could not be read. If the 240 Am(n,f) surrogate experiment is to be run at LBNL, simple modifications to the beam collection site will need to be made. The beam energy was reduced to 29 MeV, which was within an energy regime of prior experiments and tuning conditions at STARS/LIBERACE. At this energy, the beam current was successfully tuned and measured. At 29 MeV, data was collected with both the 243 Am and 238 U targets. An example particle identification plot is shown in Fig. 1. The triton-fission coincidence rate for the 243 Am target and 238 U target were measured. Coincidence rates of 0.0233(1) cps and 0.150(6) cps were observed for the 243 Am and 238 U targets, respectively. The difference in count rate is largely attributed to the available target material - the 238 U target contains approximately 7 times more atoms than the 243 Am. A proton beam current of ~0.7 nA was used for measurements on both targets. Assuming a full experimental run under similar conditions, an estimate for the run time needed was made. Figure 2 shows the number of days needed as a function of acceptable uncertainty for a measurement of 1-20 MeV equivalent neutron energy, binned into 200 keV increments. A 5% measurement will take 3 days for U, but 20 days for Am. It may be difficult to be the sole user of the LBNL cyclotron, or another facility, for such an extended period. However, a 10% measurement will take 19 hours for U, and 5 days for Am. Such a run period is more reasonable and will allow for the first ever measurement of the 240 Am(n,f) cross section. We also anticipate 40% more beam time being available at Texas A&M Cyclotron Institute compared to LBNL in FY2012. The increased amount of beam time will allow us to accumulate better statistics then what would have been available at LBNL.

43 PARTICLE ACCELERATORS↗

Robotic NDA of Holdup Deposits in Gaseous Diffusion Piping by Gamma Assay of Uranium-235 - 18331

This research exploits in-pipe access to develop robotically deployed, high-cadence, accurate, certain, paperless assay of U-235 in holdup deposits within process piping. Prior radiometric assay from outside the pipes suffered from manual deployment challenges, attenuation of detection through pipe walls, long counting times, approximate modeling, and shortfalls associated with transcription and human interpretation. These downsides limited the speed, quality, and economy of assay resulting in vast cost and budget consequences to D and D. D and D of outdated facilities cuts into these pipes as part of the demolition process, creating the unique, previously unexploited possibility of robotic in-pipe assay. The assay collimates radiation emanating from all but a short segment of pipe wall from reaching a gamma detector. Hence, the detector only views and measures source from a short segment of pipe at a given time. This is achieved by an innovative pair of collimating discs that are coaxial with the pipe and positioned fore and aft of the detector. The detector assembly is translated through pipes by an autonomous mobile robot. Beyond radiometric assay of U-235, the robot images and geometrically models the pipe interior and deposit appearance. The robot is recovered from the same pipe opening from which it is launched, hence it drives the same distance out and back, measuring the same deposits twice. This achieves redundant radiometric and odometric measurements which adds further to statistical significance of the method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The influence of environmental microseismicity on detection and interpretation of small-magnitude events in a polar glacier setting

Glacial environments exhibit temporally variable microseismicity. To investigate how microseismicity influences event detection, we implement two noise-adaptive digital power detectors to process seismic data from Taylor Glacier, Antarctica. We add scaled icequake waveforms to the original data stream, run detectors on the hybrid data stream to estimate reliable detection magnitudes and compare analytical magnitudes predicted from an ice crack source model. We find that detection capability is influenced by environmental microseismicity for seismic events with source size comparable to thermal penetration depths. When event counts and minimum detectable event sizes change in the same direction (i.e. increase in event counts and minimum detectable event size), we interpret measured seismicity changes as ‘true’ seismicity changes rather than as changes in detection. Generally, one detector (two degree of freedom (2dof)) outperforms the other: it identifies more events, a more prominent summertime diurnal signal and maintains a higher detection capability. We conclude that real physical processes are responsible for the summertime diurnal inter-detector difference. One detector (3dof) identifies this process as environmental microseismicity; the other detector (2dof) identifies it as elevated waveform activity. Our analysis provides an example for minimizing detection biases and estimating source sizes when interpreting temporal seismicity patterns to better infer glacial seismogenic processes.

54 ENVIRONMENTAL SCIENCES↗