Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

High data density temperature measurement for quasi steady-state flows

A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermocouple and the two data sets show excellent agreement This instrument maintains the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with very high data density and with automated data reduction.

Mercer, Carolyn R.↗

High Data Density Temperature Measurement for Quasi Steady-State Flows

A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermo-couple and the two data sets show excellent agreement. This instrument maintains the compact, robust design of Linniks point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts with very high data density and with automated data reduction.

Mercer, C. R.↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Optical performance of synthetic aperture telescope configurations

The diffraction-limited performances of synthetic aperture configuration arrays of four telescopes, used for coherent imaging or beam transmission, are calculated and compared. The optical performance of phased telescope arrays was found to be more sensitive to rms piston errors than to rms tilt errors. Image degradation due to pupil mapping errors imposes tight tolerances upon the structural integrity of the telescope. One part in 10,000 pupil mapping error limits the field-of-view to approximately 30 arcsec. Field curvature of the independent telescopes provides a fundamental limit to the field-of-view for phased arrays made up of two-mirror telescopes. These field-of-view limitations may profoundly affect target acquisition, tracking, or imaging applications.

Harvey, J. E.↗

Cu{sub 2}ZnSnS{sub 4} nanoflakes prepared by one step microwave irradiation technique: Effect of Cu concentration

Cu{sub 2}ZnSnS{sub 4} (CZTS) nanoflakes were synthesized in one step by microwave irradiation method. Controlling the secondary phases in Copper Zinc Tin Sulfide (CZTS) material is critical, but it is necessary to control secondary phases in order to achieve the high efficiency solar cells made from CZTS. In the recent years, CZTS has shown its growing importance in thin film photovoltaic application because of its favorable optical and electrical properties. In this work, a systematic study has been carried out by properly controlling the copper concentration to get the pure phase of CZTS. X-ray diffraction shows the CZTS kesterite structure. Optical band gap estimated from UV-Visible spectroscopy was around 1.37eV. Systematic Raman study reveals the suppression of Cu{sub 2}S peak with variation in copper concentration which otherwise was not clear from XRD and UV-visible data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Linear polarization sensitivity specifications for space-borne instruments

The radiometric accuracy of space-borne instruments such as radiometers and spectroradiometers which make measurements of the earth and other celestial objects can be compromised by the linear polarization sensitivity (LPS) induced by the optical system. Most of these optical systems contain optical elements whose reflectance or transmission is polarization dependent, such as diffraction gratings, folding and scanning mirrors, dichroic filters, and optical fibers. Optical system incorporating such elements generally display linear polarization sensitivity; different linear polarization states incident with equal radiometric power will be measured as different power levels. If the incident polarization state is unknown, the linear polarization sensitivity cannot be compensated during the data reduction. The light reflected from the earth and other planets and moons is usually partially linearly polarized, but in a random distribution. Thus, to make accurate radiometric measurements of these bodies, a radiometer or spectrometer should have a low level of linear polarization sensitivity. This paper contains a mathematical description of LPS, contains references to systems which have imposed a LPS specification, describes some of the sources of LPS, describes how to model LPS by polarization ray tracing, and discusses methods to reduce the LPS of an optical system.

Maymon, Peter W.↗

Low-Flow-Rate Dry-Powder Feeder

Apparatus feeds small, precise flow of dry powder through laser beam of optical analyzer measuring patterns of light created by forward scattering (Fraunhofer diffraction) of laser beam from powder particles. From this optical measurement, statistical distribution of sizes of powder particles computed. Rates of flow optimized for measurement of particle-size distributions. Developed for analyzing particle-size distributions of solid-propellant powders. Also adapted to pharmaceutical industry, in manufacture of metal powder, and in other applications where particle-size distributions of materials used to control rates of chemical reactions and/or physical characteristics of processes.

Ramsey, Keith E.↗

Diffraction-controlled backscattering threshold and application to Raman gap

In most classic analytical models of linear stimulated scatter, light diffraction is omitted, a priori. However, modern laser optic typically includes a variant of the random phase plate [Y. Kato et al., Phys. Rev. Lett. 53, 1057 (1984)], resulting in diffraction limited laser intensity fluctuations - or localized speckles - which may result in explosive reflectivity growth as the average laser intensity approaches a critical value [H. A. Rose and D. F. DuBois, Phys. Rev. Lett. 72, 2883 (1994)]. Among the differences between stimulated Raman scatter (SRS) and stimulated Brillouin scatter is that the SRS scattered light diffracts more strongly than the laser light with increase of electron density. This weakens the tendency of the SRS light to closely follow the most amplified paths, diminishing gain. Let G{sub 0} be the one-dimensional power gain exponent of the stimulated scatter. In this paper we show that differential diffraction gives rise to an increase of G{sub 0} at the SRS physical threshold with increase of electron density up to a drastic disruption of SRS as electron density approaches one fourth of its critical value from below. For three wave interaction lengths not small compared to a speckle length, this is a physically robust Raman gap mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring multiband excitations of interacting Bose gases in a one-dimensional optical lattice by coherent scattering

We use a coherent Bragg diffraction method to impart an external momentum to ultracold bosonic atoms trapped in a one-dimensional optical lattice. This method is based on the application of a single light pulse, with conditions where scattering of photons can be resonantly amplified by atomic density grating. An oscillatory behavior of the momentum distribution resulting from the time evolution in the lattice potential is then observed. By measuring the oscillating frequencies, we extract multiband energy structures of single-particle excitations with zero pseudomomentum transfer for a wide range of lattice depths. The excitation energy structures reveal the interaction effect through the whole range of lattice depths.

74 ATOMIC AND MOLECULAR PHYSICS↗

Use of Beacon Satellites for Efficient Uplink Transmission for Free-Space Quantum Entanglement Distribution

Efficient transmission of optical beams from ground to space is important for free-space entanglement distribution in a dual-uplink architecture in which photons from entanglement sources at two ground locations interact in an optical Bell-state measurement implemented on a satellite. Efficient transmission requires large transmitting apertures to minimize diffraction losses and high-performance adaptive optics to overcome the effects of atmospheric turbulence. Achieving good atmospheric compensation for beams transmitted to satellites is challenging because the need to point ahead of the satellite introduces anisoplanatism error that limits the effectiveness of the adaptive optics. An attractive approach for solving the point-ahead problem is to position a separate small satellite at the point-ahead location to provide a beacon source for the adaptive optics. This paper presents analysis of the requirements for the beacon source(s) for a dual-uplink entanglement-distribution demonstration. A relative performance metric is defined and evaluated for multiple beacon configurations, from a single, fixed beacon serving both ground sites to a dedicated beacon for each site continually adjusted to be at the correct point-ahead distance from the target satellite.

quantum↗

Angle-resolved diffraction grating biosensor based on porous silicon

In this study, an optical biosensor based on a porous silicon composite structure was fabricated using a simple method. This structure consists of a thin, porous silicon surface diffraction grating and a one-dimensional porous silicon photonic crystal. An angle-resolved diffraction efficiency spectrum was obtained by measuring the diffraction efficiency at a range of incident angles. The angle-resolved diffraction efficiency of the 2nd and 3rd orders was studied experimentally and theoretically. The device was sensitive to the change of refractive index in the presence of a biomolecule indicated by the shift of the diffraction efficiency spectrum. The sensitivity of this sensor was investigated through use of an 8 base pair antifreeze protein DNA hybridization. The shifts of the angle-resolved diffraction efficiency spectrum showed a relationship with the change of the refractive index, and the detection limit of the biosensor reached 41.7 nM. This optical device is highly sensitive, inexpensive, and simple to fabricate. Using shifts in diffraction efficiency spectrum to detect biological molecules has not yet been explored, so this study establishes a foundation for future work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Process for rapid detection of fratricidal defects on optics using Linescan Phase Differential Imaging

Phase-defects on optics used in high-power lasers can cause light intensification leading to laser-induced damage of downstream optics. We introduce Linescan Phase Differential Imaging (LPDI), a large-area dark-field imaging technique able to identify phase-defects in the bulk or surface of large-aperture optics with a 67 second scan-time. Potential phase-defects in the LPDI images are indentified by an image analysis code and measured with a Phase Shifting Diffraction Interferometer (PSDI). The PSDI data is used to calculate the defects potential for downstream damage using an empirical laser-damage model that incorporates a laser propagation code. A ray tracing model of LPDI was developed to enhance our understanding of its phase-defect detection mechanism and reveal limitations.

42 ENGINEERING↗

One‐Step Synthesis of Hybrid Core–Shell Metal–Organic Frameworks

Abstract Epitaxial growth of MOF‐on‐MOF composite is an evolving research topic in the quest for multifunctional materials. In previously reported methods, the core–shell MOFs were synthesized via a stepwise strategy that involved growing the shell‐MOFs on top of the preformed core‐MOFs with matched lattice parameters. However, the inconvenient stepwise synthesis and the strict lattice‐matching requirement have limited the preparation of core–shell MOFs. Herein, we demonstrate that hybrid core–shell MOFs with mismatching lattices can be synthesized under the guidance of nucleation kinetic analysis. A series of MOF composites with mesoporous core and microporous shell were constructed and characterized by optical microscopy, powder X‐ray diffraction, gas sorption measurement, and scanning electron microscopy. Isoreticular expansion of microporous shells and orthogonal modification of the core was realized to produce multifunctional MOF composites, which acted as size selective catalysts for olefin epoxidation with high activity and selectivity.

Yang, Xinyu↗

Magnetic Helicity in a Chiral-Polar Magnet Ni 2 InSbO 6

The class of chiral-polar magnets has recently captured significant interest in scientific study due to their intriguing physical phenomena. Among all the chiral-polar magnets, Ni 2 InSbO 6 stands out because of its unique attributes, such as the emergence of the topological chiral soliton lattice in the presence of an external magnetic field perpendicular to the chiral-polar axis. However, the magnetic structure of Ni 2 InSbO 6 at zero field has not been well understood yet. This work presents an analysis including polarized optical microscopy and polarized neutron diffraction on a carefully chosen Ni 2 InSbO 6 crystal. Here, results confirm the predominance of a single chiral-polar domain within the crystal and indicate the likelihood of cycloidal magnetic ordering under zero magnetic field, alongside the observation of net magnetic helicity. The existence of both a dominant chiral-polar domain and a dominant cycloidal magnetic domain within Ni 2 InSbO 6 provides an excellent platform for further exploration of its unconventional physical attributes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surface Modification by Friction Stir Processing of Low-Carbon Steel: Microstructure Investigation and Wear Performance

A low-carbon steel sheet with a thickness of 5 mm was subjected to friction stir processing (FSP) by one to four different passes. The microstructures of different regions were characterized using the optical microscopy and electron backscatter diffraction. The Vickers micro-harness was measured at the distance of 200 μm below the processed surfaces. The influence of pass numbers (PNs) on wear resistance was studied in terms of coefficients of friction (CoFs), weight losses and wear rates. SEM topographies of the worn surfaces were also studied to evaluate the wear mechanisms. Microstructure observations showed that Widmänstatten ferrite plates were formed in stir zones (SZs) and heat affected zones. As PN increased, these grains were widened due to the increment of the carbon diffusivity and lengthened because of the high heat input and microstructure anisotropy. Besides, increasing the PN causes increasing of the hardness and wear resistance, simultaneously. Specifically, the wear rate in the SZ was reduced from 2.8 × 10{sup −2} mm{sup 3} m{sup −1} in base metal to 0.3 × 10{sup −2} mm{sup 3} m{sup −1} in sample which was subjected to 4 FSP passes. However, variation in PN had no considerable effect on CoFs. Oxidative wear mechanism was observed on the worn surface of the steel and the FSPed samples while more debris was formed by increasing the PNs.

36 MATERIALS SCIENCE↗

Effects of Nd Addition on the Microstructure and Mechanical Properties of Extruded Mg-6Gd-2.5Y-0.5Zr Alloy

The microstructure, age-hardening behavior, mechanical properties and texture of extruded Mg-6Gd-2.5Y-0.5Zr alloys with various additions of Nd have been investigated through optical microscopy, x-ray diffraction, scanning electron microscopy, transmission electron microscopy, electron back-scattered diffraction, hardness and tensile tests. The results indicate that the number of second-phase particles in the as-extruded alloys increases (especially with the addition of 1.5 wt.% Nd), and the amount of the strengthening β′ phase in the peak-aged sample initially increases, and then decreases when the content of Nd increases above 1.0 wt.%. The precipitation of second-phase particles in the extrusion process weakens the age strengthening. The peak-aged Mg-6Gd-2.5Y-1Nd-0.5Zr alloy shows a maximum yield strength of 259 MPa and an ultimate tensile strength of 350 MPa, which can be attributed to the finely dispersed strengthening β′ phase. All as-extruded alloys exhibit that (0001) planes are aligned perpendicular to the extrusion direction, and the maximum intensity of the texture increases gradually with Nd addition.

36 MATERIALS SCIENCE↗

Mechanical Properties and Microstructural Evolution of Yb-Modified Al-20%Si Alloy

In the study, the mechanical properties and microstructural evolution of hypereutectic Al-20%Si-xYb alloys (x = 0, 0.1, 0.3, 0.5 and 0.7 wt.%) were studied. The as-prepared samples were characterized by scanning electron microscopy, optical microscope, x-ray diffraction (XRD) and electron probe microanalysis. The characterization results showed with the addition amount of Yb increasing to 0.5%, the eutectic Si structure was gradually modified from coarse needle-like/platelet-like structure into fine coral-like fibrous structure and the primary Si phases were gradually converted from coarse platelet-like/star-like/polygonal shape into fine blocky shape. In particular, according to the results of WDS and XRD analyses, the Yb-rich intermetallic phase in the Al-20%Si alloy is Al{sub 3}Yb. Tensile test was carried out to study the mechanical properties of Al-20%Si-x%Yb alloys, and results showed that the elongation and ultimate tensile strength increased by 73.6% and 64.5%, respectively.

36 MATERIALS SCIENCE↗

Fabrication of Ta-Reinforced Cu-Based Bulk Metallic Glass Composites by High-Pressure Torsion

Ex situ Cu{sub 54}Zr{sub 22}Ti{sub 18}Ni{sub 6} matrix bulk metallic glass composites (BMGCs) reinforced with Ta particles (10–30 vol.%) were fabricated by high-pressure torsion (HPT) under applied pressure of 6 GPa for 1–3 turns at temperatures of 25 or 200 °C. The densification, structure, thermal, and mechanical properties of BMGC samples were investigated by Archimedes densitometry, optical microscopy, x-ray diffraction, differential scanning calorimetry, small punch test, and microhardness measurements. Near full-density BMGC disks (relative densities higher than 0.97) are fabricated using HPT, irrespective of the processing strain and temperature. The microhardness of BMGCs is improved by increasing the number of turns, or the processing temperature due to the improvement in the deformation degree of both the amorphous and Ta particles as well as the reduction in the interlayer spacing of Ta particles. Nevertheless, there is an optimal amount of Ta which gives rise to the peak hardness in the BMGC samples, depending on the amount of imposed strain during HPT. The results of small punch test indicate that the addition of Ta to the monolithic BMG and increasing the HPT temperature significantly enhance the fracture load and deflection.

36 MATERIALS SCIENCE↗