Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

A Lunar Farside Low Radio Frequency Array for Dark Ages 21-cm Cosmology

An array of low-frequency dipole antennas on the lunar farside surface will probe a unique, unexplored epoch in the early Universe called the Dark Ages. It begins at Recombination when neutral hydrogen atoms formed, first revealed by the cosmic microwave background. This epoch is free of stars and astrophysics, so it is ideal to investigate high energy particle processes including dark matter, early Dark Energy, neutrinos, and cosmic strings. A NASA-funded study investigated the design of the instrument and the deployment strategy from a lander of 128 pairs of antenna dipoles across a 10 kmx10 km area on the lunar surface. The antenna nodes are tethered to the lander for central data processing, power, and data transmission to a relay satellite. The array, named FARSIDE, would provide the capability to image the entire sky in 1400 channels spanning frequencies from 100 kHz to 40 MHz, extending down two orders of magnitude below bands accessible to ground-based radio astronomy. The lunar farside can simultaneously provide isolation from terrestrial radio frequency interference, the Earth's auroral kilometric radiation, and plasma noise from the solar wind. It is thus the only location within the inner solar system from which sky noise limited observations can be carried out at sub-MHz frequencies. Through precision calibration via an orbiting beacon and exquisite foreground characterization, the farside array would measure the Dark Ages global 21-cm signal at redshifts z~35-200. It will also be a pathfinder for a larger 21-cm power spectrum instrument by carefully measuring the foreground with high dynamic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront detector

A wavefront sensor system suitable for integration into an integrated circuit light detector may provide for wave angle sensors having varying functional relationships between the wave angle and signal to provide improved dynamic range. These wave angle sensors may be combined with integrated circuit phase angle sensors for a more complete analysis of the waveform.

Yu, Zongfu↗

Beyond RMS: Understanding the Evolution of Beam Distributions in High Intensity Linacs

Understanding the evolution of beams with space charge is crucial to design and operation of high intensity linacs. While the community holds a broad understanding of the mechanisms leading to emittance growth and halo formation, there is outstanding discrepancy between measurements and beam evolution models that precludes prediction of halo losses. This may be due in part to insufficient information of the initial beam distribution. This talk will describe work at the SNS Beam Test Facility to directly measure the 6D beam distribution. Full-and-direct 6D measurement has revealed hidden but physically significant dependence between the longitudinal distribution and transverse coordinates. This nonlinear correlation is driven by space charge and reproduced by self-consistent simulation of the RFQ. Omission of this interplane correlation, common when bunches are reconstructed from lower-dimensional measurements, degrades downstream predictions. This talk will also describe the novel diagnostics supporting this work. This includes ongoing improvements to efficiency of the 6D phase space measurement as well as recent achievement of six orders of dynamic range in 2D phase space.

Ruisard, Kiersten↗

Photo Doppler Velocimetry and Gamma/Neutron Yield Measurements of Godiva-IV Critical Assembly

The purpose of this experiment was to collect data for a dynamic benchmark of the Godiva-IV burst assembly. Data were taken using two different measurement systems. The gamma & neutron flux was measured using a calibrated, high-dynamic-range scintillator detector, the MHD-240. The measurement will be used to determine the total fission yield and alpha throughout the burst and shutdown sequence of Godiva-IV. The Photon Doppler Velocimetry (PDV) measurement detected the surface motion of the burst assembly as a function of time. The combined data will be used in a multi-physics simulation of the Godiva-IV burst assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power handling digitizer using photonics

Devices, methods for analog-to-digital converters (ADCs) that perform high-dynamic range measurements based on optical techniques are disclosed. In one example aspect, an optical encoder includes a polarization rotator configured to receive a train of optical pulses, and an electro-optic (EO) modulator coupled to an output of the polarization rotator. The EO modulator is configured to receive a radio frequency (RF) signal and to produce a phase modulated signal in accordance with the RF signal. The optical encoder also includes a polarizing beam splitter coupled to the output of the EO modulator; and an optical hybrid configured to receive two optical signals from the polarizing beam splitter and to produce four optical outputs that are each phase shifted with respect to one another.

DeVore, Peter Thomas Setsuda↗

Snowmass2021 Cosmic Frontier White Paper: Cosmological Simulations for Dark Matter Physics

Over the past several decades, unexpected astronomical discoveries have been fueling a new wave of particle model building and are inspiring the next generation of ever-more-sophisticated simulations to reveal the nature of Dark Matter (DM). This coincides with the advent of new observing facilities coming online, including JWST, the Rubin Observatory, the Nancy Grace Roman Space Telescope, and CMB-S4. The time is now to build a novel simulation program to interpret observations so that we can identify novel signatures of DM microphysics across a large dynamic range of length scales and cosmic time. This white paper identifies the key elements that are needed for such a simulation program. We identify areas of growth on both the particle theory side as well as the simulation algorithm and implementation side, so that we can robustly simulate the cosmic evolution of DM for well-motivated models. We recommend that simulations include a fully calibrated and well-tested treatment of baryonic physics, and that outputs should connect with observations in the space of observables. We identify the tools and methods currently available to make predictions and the path forward for building more of these tools. A strong cosmic DM simulation program is key to translating cosmological observations to robust constraints on DM fundamental physics, and provides a connection to lab-based probes of DM physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Readout for Calorimetry at Future Colliders: A Snowmass 2021 White Paper

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and precision timing the readout systems will become increasingly complex. This white paper reviews the challenges and opportunities in calorimeter readout at future collider detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INITIAL COMMISSIONING EXPERIENCE WITH THE SPALLATION NEUTRON SOURCE VERTICAL TEST AREA RF SYSTEM

The Spallation Neutron Source (SNS) has developed a vertical test area (VTA) for the testing and qualification of superconducting radio frequency cavities. The associated RF System successfully supported the initial commissioning of the VTA system and has been utilized for cavity testing at both 4 and 2 K. As operational experience was gained, improvements to the RF system were implemented to better utilize the dynamic range of the system, and software updates and additions were made to meet operational needs. The system continues to evolve as we gain better understanding of the testing needs.

Crofford, Mark↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL CGI and PHIL Platform for Validation of Multi-Technology Energy Systems at Scale

The presentation is an update on National Renewable Energy Laboratory Flatirons Campus' capabilities around multi-megawatt grid simulation and power hardware-in-the-loop. Recent improvements in operational and dynamic range of existing 7MVA Controllable Grid Interface (CGI) are described together with improvements in site-wide automation and data acquisition systems. In later part of presentation, a second 19.9MVA CGI that is currently under development is introduced. Its features are described further explaining future site's capabilities.

acquisition↗

Deep sub electron noise readout in CCD systems using digital filtering techniques

Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10 K pixels per second and keep the full CCD spatial resolution and signal dynamic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical array for high-quality imaging in harsh environments

Methods and apparatus are disclosed for producing high quality images in uncontrolled or impaired environments. In some examples of the disclosed technology, groups of cameras for high dynamic range (HDR), polarization diversity, and optional other diversity modes are arranged to concurrently image a common scene. For example, in a vehicle checkpoint application, HDR provides discernment of dark objects inside a vehicle, while polarization diversity aids in rejecting glare. Spectral diversity, infrared imaging, and active illumination can be applied for better imaging through a windshield. Preprocessed single-camera images are registered and fused. Faces or other features of interest can be detected in the fused image and identified in a library. Impairments can include weather, insufficient or interfering lighting, shadows, reflections, window glass, occlusions, or moving objects.

Baba, Justin S.↗

Signal Processing Board for Beam Loss Monitors

This paper describes a new VME based machine protection Beam Loss Monitor (BLM) signal processing board designed at Jefferson Lab which features high sensitivity, high resolution, and low cost per channel. This double-wide VME board provides eight-channel signal processing with each channel having linear, logarithmic, and integrating amplifiers that simultaneously provide the optimal signal processing for both machine protection and beam diagnostics. Amplified signals are independently sampled by 16-bit, fast ADCs and then further processed through a Field Programmable Gate Array (FPGA). It also has features of fast shutdown interface (FSD), beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer. The initial experimental test shows that the BLM board has fast response (<< 1us) for integrating and wide dynamic range from 10 nA to 1 mA (>50 dB) for logarithmic signals. The board is suitable for signal processing from photomultiplier (PMT) and ion chamber detectors. Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

Yan, Jianxun↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗