Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Material gauge factor of directional electric potential drop sensors for creep monitoring

Directional electric potential drop measurements can be exploited for in-situ monitoring of creep in metals. The sensor monitors the variation in the ratio of the resistances measured simultaneously in the axial and lateral directions using a square-electrode configuration. This method can efficiently separate the mostly isotropic common part of the resistivity variation caused by reversible temperature variations from the mostly anisotropic differential part caused by direct geometrical (size and shape) and indirect material (resistivity) effects of creep. Similarly to ordinary strain gauges, the relative sensitivity of the sensor is defined as a gauge factor that can be approximated as the sum of geometrical and material parts. Initially, subtle material changes produce weak electric anisotropy via reversible and irreversible piezoresistivity due to elastic and plastic strains, respectively. At high temperature, much stronger irreversible resistivity changes also occur due to preferentially aligned clusters of cavities developing along grain boundaries approximately perpendicular to the applied stress and subsequent cracks forming between these cavities. The ensuing electric anisotropy is detected by the directional sensor. Although the material effects remain smaller than the geometrical ones up to the initiation of preferentially oriented cracks, later the material gauge factor sharply increases and close to rupture can reach a value of more than 10.

36 MATERIALS SCIENCE↗

Demonstration of a Fiber Optic Regression Probe in a High-Temperature Flow

The capability to provide localized, real-time monitoring of material regression rates in various applications has the potential to provide a new stream of data for development testing of various components and systems, as well as serving as a monitoring tool in flight applications. These applications include, but are not limited to, the regression of a combusting solid fuel surface, the ablation of the throat in a chemical rocket or the heat shield of an aeroshell, and the monitoring of erosion in long-life plasma thrusters. The rate of regression in the first application is very fast, while the second and third are increasingly slower. A recent fundamental sensor development effort has led to a novel regression, erosion, and ablation sensor technology (REAST). The REAST sensor allows for measurement of real-time surface erosion rates at a discrete surface location. The sensor is optical, using two different, co-located fiber-optics to perform the regression measurement. The disparate optical transmission properties of the two fiber-optics makes it possible to measure the regression rate by monitoring the relative light attenuation through the fibers. As the fibers regress along with the parent material in which they are embedded, the relative light intensities through the two fibers changes, providing a measure of the regression rate. The optical nature of the system makes it relatively easy to use in a variety of harsh, high temperature environments, and it is also unaffected by the presence of electric and magnetic fields. In addition, the sensor could be used to perform optical spectroscopy on the light emitted by a process and collected by fibers, giving localized measurements of various properties. The capability to perform an in-situ measurement of material regression rates is useful in addressing a variety of physical issues in various applications. An in-situ measurement allows for real-time data regarding the erosion rates, providing a quick method for empirically anchoring any analysis geared towards lifetime qualification. Erosion rate data over an operating envelope could also be useful in the modeling detailed physical processes. The sensor has been embedded in many regressing media to demonstrate the capabilities in a number of regressing environments. In the present work, sensors were installed in the eroding/regressing throat region of a converging-diverging flow, with the working gas heated to high temperatures by means of a high-pressure arc discharge at steady-state discharge power levels up to 500 kW. The amount of regression observed in each material sample was quantified using a later profilometer, which was compared to the in-situ erosion measurements to demonstrate the efficacy of the measurement technique in very harsh, high-temperature environments.

Korman, Valentin↗

Novel Battery Management System with Distributed Wireless and Fiber Optic Sensors for Early Detection and Suppression of Thermal Runaway in Large Battery Packs, FY13 Q4 Report, ARPA-E Program: Advanced Management Protection of Energy Storage Devices (AMPE

Technology has been developed that enables monitoring of individual cells in highcapacity lithium-ion battery packs, with a distributed array of wireless Bluetooth 4.0 tags and sensors, and without proliferation of extensive wiring harnesses. Given the safety challenges facing lithium-ion batteries in electric vehicle, civilian aviation and defense applications, these wireless sensors may be particularly important to these emerging markets. These wireless sensors will enhance the performance, reliability and safety of such energy storage systems. Specific accomplishments to date include, but are not limited to: (1) the development of wireless tags using Bluetooth 4.0 standard to monitor a large array of sensors in battery pack; (2) sensor suites enabling the simultaneous monitoring of cell voltage, cell current, cell temperature, and package strain, indicative of swelling and increased internal pressure, (3) small receivers compatible with USB ports on portable computers; (4) software drivers and logging software; (5) a 7S2P battery simulator, enabling the safe development of wireless BMS hardware in the laboratory; (6) demonstrated data transmission out of metal enclosures, including battery box, with small variable aperture opening; (7) test data demonstrating the accurate and reliable operation of sensors, with transmission of terminal voltage, cell temperature and package strain at distances up to 110 feet; (8) quantification of the data transmission error as a function of distance, in both indoor and outdoor operation; (9) electromagnetic interference testing during operation with live, high-capacity battery management system at Yardney Technical Products; (10) demonstrated operation with live high-capacity lithium-ion battery pack during charge-discharge cycling; (11) development of special polymer-gel lithium-ion batteries with embedded temperature sensors, capable of measuring the core temperature of individual of the cells during charge-discharge cycling at various temperatures, thereby enabling earlier warning of thermal runaway than possible with external sensors. Ultimately, the team plans to extend this work to include: (12) flexible wireless controllers, also using Bluetooth 4.0 standard, essential for balancing large-scale battery packs. LLNL received $925K for this project, and has $191K remaining after accomplishing these objectives.

25 ENERGY STORAGE↗

Micro-differential scanning calorimeter for liquid biological samples

Here, we developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. Our design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. Furthermore, we demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturized sample consumption.

42 ENGINEERING↗

Facile synthesis of α-Fe{sub 2}O{sub 3} nanoparticles for high-performance CO gas sensor

Highlights: • We have demonstrated a facile method to prepare Fe{sub 2}O{sub 3} nanoparticles. • The gas sensing properties of α-Fe{sub 2}O{sub 3} have been invested. • The results show potential application of α-Fe{sub 2}O{sub 3} NPs for CO sensors in environmental monitoring. - Abstract: Iron oxide nanoparticles (NPs) were prepared via a simple hydrothermal method for high performance CO gas sensor. The synthesized α-Fe{sub 2}O{sub 3} NPs were characterized by X-ray diffraction, nitrogen adsorption/desorption isotherm, scanning electron microscopy (SEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), and selected area electron diffraction (SAED). The SEM, TEM results revealed that obtained α-Fe{sub 2}O{sub 3} particles had a peanut-like geometry with hemispherical ends. The response of the α-Fe{sub 2}O{sub 3} NPs based sensor to carbon monoxide (CO) and various concentrations of other gases were measured at different temperatures. It found that the sensor based on the peanut-like α-Fe{sub 2}O{sub 3} NPs exhibited high response, fast response–recovery, and good selectivity to CO at 300 °C. The experimental results clearly demonstrated the potential application of α-Fe{sub 2}O{sub 3} NPs as a good sensing material in the fabrication of CO sensor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low power sensor for NO x detection

Detection and capture of toxic nitrogen oxides (NO x ) is important for emissions control of exhaust gases and general public health. The low power sensor provides direct electrically detection of trace (0.5-5 ppm) NO 2 at relatively low temperatures (50° C.) via changes in the electrical properties of nitrogen-oxide-capture active materials. For example, the high impedance of MOF-74 enables applications requiring a near-zero power sensor or dosimeter, such as for smart industrial systems and the internet of things, with 0.8 mg MOF-74 active material drawing <15 pW for a macroscale sensor 35 mm 2 area.

Small, Leo J.↗

Hyporheic Zone Microbiome Assembly Is Linked to Dynamic Water Mixing Patterns in Snowmelt-Dominated Headwater Catchments

We report that terrestrial and aquatic elemental cycles are tightly linked in upland fluvial networks. Biotic and abiotic mineral weathering, microbially mediated degradation of organic matter, and anthropogenic influences all result in the movement of solutes (e.g., carbon, metals, and nutrients) through these catchments, with implications for downstream water quality. Within the river channel, the region of hyporheic mixing represents a hot spot of microbial activity, exerting significant control over solute cycling. To investigate how snowmelt-driven seasonal changes in river discharge affect microbial community assembly and carbon biogeochemistry, depth-resolved pore water samples were recovered from multiple locations around a representative meander on the East River near Crested Butte, CO, USA. Vertical temperature sensor arrays were also installed in the streambed to enable seepage flux estimates. Snowmelt-driven high river discharge led to an expanding zone of vertical hyporheic mixing and introduced dissolved oxygen into the streambed that stimulated aerobic microbial respiration. These physicochemical processes contributed to microbial communities undergoing homogenizing selection, in contrast to other ecosystems where lower permeability may limit the extent of mixing. Conversely, lower river discharge conditions led to a greater influence of upwelling groundwater within the streambed and a decrease in microbial respiration rates. Finally, associated with these processes, microbial communities throughout the streambed exhibited increasing dissimilarity between each other, suggesting that the earlier onset of snowmelt and longer periods of base flow may lead to changes in the composition (and associated function) of streambed microbiomes, with consequent implications for the processing and export of solutes from upland catchments.

58 GEOSCIENCES↗

Design and fabrication of a differential scanning nanocalorimeter

This paper describes the design, fabrication, and characterization of a differential scanning nanocalorimeter that significantly reduces the sample volume to microliters and can potentially improve the temperature sensitivity to 10 µK. The nanocalorimeter consists of a polymeric freestanding membrane, four high-sensitive low-noise thermistors based on silicon carbide (SiC), and a platinum heater and temperature sensor. With the integrated heater and sensors, temperature scanning and power compensation can be achieved for calorimetric measurement. Temperature sensing SiC film was prepared by using sintered SiC target and DC magnetron sputtering under different gas pressures and sputtering power. The SiC sensing material is characterized through the measurement of current–voltage curves and noise levels. The thermal performance of a fabricated nanocalorimeter is studied in simulation and experiment. The experiment results show the device has excellent thermal isolation to hold thermal energy. As a result, the noise test together with the simulation show the device is promising for micro 10 µK temperature sensitivity and nanowatt resolution which will lead to low-volume ultra-sensitive nanocalorimetry for biological processes, such as protein folding and ligand binding.

42 ENGINEERING↗

OPET Hardware (Open PV Electrical Tool Hardware) [SWR-25-42]

OPET (Open-source Photovoltaic Electrical Tool) is used for performance measurements of solar photovoltaic (PV) devices in the field under natural sunlight or in the lab under artificial light. Its primary use is in research and development of solar cells and modules, specifically in reliability and durability research of PV devices. Some features and functions include: -IV curve measurements with linear or cosine distributed measurement points -PV device active loading at open circuit voltage (Voc), short circuit current (Isc) and maximum power point (Pmp) -Bias power supply to overcome series resistance in contact wires for Isc measurements and loading -PV voltage input in five ranges from 1V to 100V -PV current input ranges -Low current version, six current ranges from 1.1mA to 340mA -High current version, six current ranges from 50mA to 15A -IO ports for I2C and SPI temperature sensor Arduino extension boards -Integrated fan control This repository contains everything relating to the hardware of the OPET device. If you are looking for the firmware or software repositories, links are below: https://github.com/NREL/opet-firmware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

Radiation hardness test results on a new anisotropic adhesive to replace bump-bonding in HEP detectors

Standard technique widely used for hybrid detectors Sensors are connected to CMOS read-out chip pixel by pixel in parallel Several lithography steps required after completion of foundry sensor or foundry CMOS process Flatness – variation must be less than bump height Requires a “tall” bumps Temperature and pressure applied Potential to damage components, especially as sensors and ASICS are made thinner for high luminosity upgrades

Segal, Julie↗

IMS Rapid Response 2023-2 (RR 2023-RND-2): Magnetic order in layered bismuthide RhMnBi 3 (Final Report)

Microelectronics are technologies (mostly theoretical at this point) to create electronic circuits with components of atomic length scale. One of the key materials innovations enabling this technology is exfoliatable two-dimensional materials. These materials allow thin sheets of only a few atoms thick to be easily created in the laboratory. More and more of these materials are reported every year, but few have been characterized in detail. Thus a major goal in materials research in pursuit of microelectronic devices is characterizing newly discovered materials to evaluate their properties. The goal of this project was the measure and understand the magnetic order in a newly discovered van der Waals magnet RhMnBi 3 . Bulk property experiments indicated very complicated magnetic behavior, with multiple phase transitions between 2K and 300K (room temperature). This potentially indicated highly sensitive and tunable magnetism appropriate for single-layer magnetic switches and sensors.

36 MATERIALS SCIENCE↗

High-temperature irradiation-resistant thermocouple instability model for in-pile reactor use

This article presents an instability model for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Here the term instability defines the superposition of both drift and inhomogeneity of TC thermoelements occurring simultaneously. The HTIR-TC is an advanced thermocouple (TC) that uses the refractory metals niobium and molybdenum as sensing thermoelements for generating electromotive force (EMF) in a field of neutrons and at temperatures upward of 1,600°C. In the Advanced Gas Reactor (AGR) 5/6/7 tests conducted at Idaho National Laboratory’s Advanced Test Reactor (ATR), the HTIR-TCs showed low to moderate instability throughout the life of the test. The instability model reveals that HTIR-TCs can, when the operating temperature of the reactor fuel is normal, maintain performance throughout an 18-month refueling cycle typical of nuclear power plants, reflecting an instability of less than ±1%. The HTIR-TC is also qualified for incorporation into a test fixture during the testing of new fuels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wind-tunnel calibration and requirements for in-flight use of fixed hemispherical head angle-of-attack and angle-of-sideslip sensors

Wind-tunnel tests were conducted with three different fixed pressure-measuring hemispherical head sensor configurations which were strut-mounted on a nose boom. The tests were performed at free-stream Mach numbers from 0.2 to 3.6. The boom-angle-of-attack range was -6 to 15 deg, and the angle-of-sideslip range was -6 to 6 deg. The test Reynolds numbers were from 3.28 million to 65.6 million per meter. The results were used to obtain angle-of-attack and angle-of-sideslip calibration curves for the configurations. Signal outputs from the hemispherical head sensor had to be specially processed to obtain accurate real-time angle-of-attack and angle-of-sideslip measurements for pilot displays or aircraft systems. Use of the fixed sensors in flight showed them to be rugged and reliable and suitable for use in a high temperature environment.

Montoya, E. J.↗

Detection of moisture and moisture related phenomena from Skylab

The author has identified the following significant results. The high correlations between radiometric temperature and soil moisture content are shown to remain quite high for independent footprints of the S194 sensor. Since an analysis based on overlapping footprints had previously been reported with a high correlation, it was necessary to verify that the correlation did not arise from dependent data.

Eagleman, J. R.↗

High-Resolution Thermal X-Ray Detector

Thermal pulses from single photons measured. Detector, consists of X-ray absorber, temperature sensor in absorber, and thermal link from absorber to heat sink. X-ray photon detected by measuring temperature rise immediately following absorption of photon. Thermal X-ray detector, tested successfully in prototype, in theory operates as spectrometer that provides 100 times spectral resolution of conventional to detect trace constituents in materials by X-ray fluorescence. Also used for measuring energies of energetic electrons and weak pulses of light.

Moseley, S. H.↗

Acoustic and thermal testing of the Titan/Centaur upper stage

A new version of the Centaur high-energy upper stage is being produced by General Dynamics for the USAF/Martin Marietta Titan launch vehicle. The Titan/Centaur upper stage is subject to consecutive acoustic and thermal testing in General Dynamics' Acoustic and Thermal Test Facility (ATTF). All data is acquired and processed digitally using the high-speed data acquisition system located in the ATTF. Processed data from over 250 sensors measuring acceleration, temperature, and sound pressure level is made available to the test team in minutes for use in making real-time test decisions. These tests represent the first consecutive large-scale environmental tests conducted on a complete, pressure stabilized, cryogenically tanked space launch vehicle. Some of the unique challenges involved in testing the Titan/Centaur and how these challenges were met using the ATTF are described.

Gehringer, Mark↗