Search NASA⌕ Search

SEARCH · Search NASA

Results for “INGESTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Evaluation of Cutaneous Blood Flow During Lower Body Negative Pressure to Prevent Orthostatic Intolerance of Bedrest

Orthostatic tolerance is markedly impaired in most of the crewmembers during space flight and could seriously compromise crew safety during and immediately after landing. NASA investigators are studying the use of lower body negative pressure (LBNP) as a countermeasure to this intolerance. It is hypothesized that the continuously changing vascular pressure induced by sinusoidal LBNP with an additional countermeasure of salt and water will help crewmembers to be in a more acceptable physiologic condition to enter the earth's atmosphere. In ground based studies, subjects on bedrest provide the model for studying the physiologic effects of weightlessness. When subjects are treated with sinusoidal LBNP, negative pressures ranging from 0 to -60 mm/Hg are administered during a two hour period. This increases body fluids in the legs and lower body. This paper reports the results of two subjects who were placed on bedrest for six days. The subjects were randomly selected for either the control or treatment mode. The subject receiving the treatment mode ingested salt tablets and water on day 4 of the bedrest period. A ramp LBNP of two hours was next administered to this subject. The control subject did not receive anything during the bedrest period. Laser Doppler was used to measure the cutaneous blood flow of the forearm and calf to monitor vasoconstrictor effects of the baroreceptor reflex. Data indicated that skin blood flow in the treatment subject was higher than baseline in the forearm while the skin blood flow was decreased in the control subject.

Rubin, Marilyn↗

Noninvasive Ph-telemetric Measurement of Gastrointestinal Function

The purpose of this study was to gain experience with and validate the Heidelberg pH-telemetric methodology in order to determine if the pH-telemetric methodology would be a useful noninvasive measure of gastrointestinal transit time for future ground-based and in-flight drug evaluation studies. The Heidelberg pH metering system is a noninvasive, nonradioactive telemetric system that, following oral ingestion, continuously measures intraluminal pH of the stomach, duodenum, small bowel, ileocecal junction, and large bowel. Gastrointestinal motility profiles were obtained in normal volunteers using the lactulose breath-hydrogen and Heidelberg pH metering techniques. All profiles were obtained in the morning after an overnight fast. Heidelberg pH profiles were obtained in the fasting and fed states; lactulose breath-hydrogen profiles were obtained after a standard breakfast. Mouth-to-cecum transit time was measured as the interval from administration of lactulose (30 ml; 20 g) to a sustained increase in breath-hydrogen of 10 ppm or more. Gastric emptying time was measured as the interval from the administration of the Heidelberg capsule to a sustained increase in pH of three units or more.

Tietze, Karen J.↗

Low Temperature Environment Operations of Turboengines (Design and User's Problems)

The author summarizes and links together a number of papers that were presented at the Propulsion and Energetics (PEP) symposium on low temperature environment operation of turbojet engines that was held October 8 to 12, 1990. Topics covered include operational experience of ice ingestion in the turboprop engine in the 2,000 hp class, icing on helicopter turbo engines, icing test facilities, ice relevant cloud physical parameters, and low temperature and fuel problems.

R Jacques↗

Nutritional Requirements for Space Station Freedom Crews

The purpose of this report was to set preliminary nutritional requirements for crewmembers flying from 90 to 180 day missions on Space Station Freedom. Specific recommendations included providing crewmembers with in flight feedback on nutritional intake, weight and strength, and incorporating issues of energy intake, body weight, body composition, strength, and protein intake in the flight medicine program. Exercise must be considered an integral part of any plan to maintain nutritional status, especially those modes that stress the skeleton and maintain body weight. Nutrient intake, amount of exercise, and drugs ingested must be recorded daily; high priority should be given to development of fully automated record systems that minimize astronauts' effort. A system of nutritional supplements should be developed to provide a method for reducing intake deficits that become apparent. Finally, post flight monitoring should include bone density, muscle mass and function, and iron status at three and six months after landing.

Lane, Helen W.↗

Comparison of central axis and jet ring coolant supply for turbine disk cooling on a SSME-HPOTP model

The test facility, test methods and results are presented for an experimental study modeling the cooling of turbine disks in the blade attachment regions with multiple impinging jets, in a configuration simulating the disk cooling method employed on the Space Shuttle Main Engine oxygen turbopump. The study's objective was to provide a comparison of detailed local convection heat transfer rates obtained for a single center-supply of disk coolant with those obtained with the present flight configuration where disk coolant is supplied through an array of 19 jets located near the disk outer radius. Specially constructed disk models were used in a program designed to evaluate possible benefits and identify any possible detrimental effects involved in employing an alternate disk cooling scheme. The study involved the design, construction and testing of two full scale rotating model disks, one plane and smooth for baseline testing and the second contoured to the present flight configuration, together with the corresponding plane and contoured stator disks. Local heat transfer rates are determined from the color display of encapsulated liquid crystals coated on the disk in conjunction with use of a computer vision system. The test program was composed of a wide variety of disk speeds, flowrates, and geometrical configurations, including testing for the effects of disk boltheads and gas ingestion from the gas path region radially outboard of the disk-cavity.

Kim, Y. W.↗

Three-dimensional simulation of a translating strut inlet

A three-dimensional Navier-Stokes code is used to numerically simulate the flow through a translating strut scramjet inlet. The inlet has variable geometry for efficient operation over a wide speed range. Overall flow-field features such as the corner flow, topwall separation, shockwave coalescence, cowl pressure increase, and flow distortion at the throat are investigated. Comparisons are made with experimental results to provide for the assessment of the present analysis. Effects of boundary-layer ingestion on the overall flow features are also investigated.

Singh, D. J.↗

Liquid hydrogen suction dip and slosh wave excitation during draining under normal and reduced gravity environments

The paper discusses the dynamical behavior of vapor ingestion, liquid residual at the incipience of suction dip, slosh wave excitation under normal and reduced gravity and different flow rates during liquid hydrogen draining. Liquid residuals at the incipience of suction dip increase as the values of gravity decrease. Also liquid residuals increase with the draining flow rates. Lower ratio of Bond number and Weber number are unable to excite slosh waves. Lower flow rates and higher gravity excites waves with lower frequencies and higher wave amplitude slosh waves.

Hung, R. J.↗

Thyroid effects of iodine and iodide in potable water

Experiments are reviewed which examine the comparative toxicological effects of iodide (I) and iodine (I2) when used to disinfect drinking water. References are made to a subchronic study in rats, a comparison of the distribution of radiolabeled I and I2, and a demonstration of thyroxine formation in the gastrointestinal tract. The results of the study of the rats are examined in detail; the findings show that I and I2 have opposite effects on the concentrations of thyroid hormones in blood. Iodide slightly decreases circulating thyroxine, while I2 significantly increases the thyroxine concentrations, decreases triiodothyronine levels, and does not change the weight of the thyroid gland. The related effects of I2 ingestion are set forth in detail and are shown to be unique to I2 contamination. Iodine can counteract the effects of iodide and should therefore be used as a disinfectant in drinking water.

Bull, Richard J.↗

Simulation of the 1979 spring bloom in the Mid-Atlantic Bight - A coupled physical/biological/optical model

A coupled physical/biological/optical model is developed for studies of phytoplankton variability in the spring 1979 Mid-Atlantic Bight, as observed by CZCS imagery. The model incorporates advection, mixing, sinking, growth as a function of light, temperature, nutrient availability, and death as a function of ingestion. It produced chlorophyll concentrations within the first attenuated depth within 1 standard deviation of CZCS imagery on large scale. The primary production estimates obtained using this model were within reasonable agreement with those measured in situ.

Gregg, Watson W.↗

A procedure for sizing propulsion system filter capacity

A propulsion system filter has the function of protecting downstream components from propellant-borne particulate matter. A the same time, it must be designed with sufficient capacity to ensure that it will not clog during the life of the spacecraft. This capacity can be quantitatively calculated by means of the procedure described here. Previous work has presented limited data which suggest that filter clogging is a function of the number and size of ingested particles. Cleaning specifications for propusion system components are also normally given in terms of the number and size of particles removed by the flow of test fluid. It is proposed here that the filter capacity be given in terms of the number and size of particles, which in turn may be convected to an equivalent quantity of test dust.

Jan, Darrell L.↗

Investigations of the mechanisms by which lower body negative pressure (LBNP) improves orthostatic responses

Saline ingestion during LBNP is a counter measure proposed to improve orthostatic function during space flight. To understand the mechanism(s) responsible for this effect, body fluid, endocrine, and orthostatic responses (graded LBNP tests) were measured during bed rest (BR) and after 2 hr and 4 hr LBNP/saline treatments (-30 mm Hg and 1 liter of isotonic saline). PV (from I-125 and hematocrit measurements) decreased during BR but was restored to the pre-bed rest level (3157 +/- 161 ml) 20 hrs after both 2 hr (3109 +/- 146 ml) and 4 hr (3144 +/- 173 ml) LBNP. The heart rate response to graded LBNP tests was significantly improved after the 4 hr, but not after the 2 hr treatment. These results suggest PV expansion may be responsible for some improvement in orthostatic responses, but other mechanisms also must contribute.

Fortney, S. M.↗

Therapeutic effectiveness of medications taken during spaceflight

The therapeutic effectiveness of medications during spaceflight is considered in light of extensive anecdotal and experimental evidence. Attention is given to a range of medications for space motion sickness, sleeplessness, and physical discomfort. About 70 individual cases are reviewed in which crewmembers used such medications as: (1) scopolamine hydrobromide, dextroamphetamine sulfate, and promethazine hydrochloride for motion sickness; (2) metoclopramide hydrochloride and naloxone hydrochloride for bowel motility; and (3) aspirin and acetaminophen for headache and back pain. The effectiveness of orally ingested medications for space motion sickness is shown to be very low, while promethazine hydrochloride is effective when administered intramuscularly. The medications for pain are shown to be generally effective, and the use of sleep-inducing medications is limited by potentially detrimental performance effects.

Pool, Sam L.↗

Health-risk based approach to setting drinking water standards for long-term space missions

In order to develop plausible and appropriate drinking water contaminant standards for longer-term NASA space missions, such as those planned for the Space Exploration Initiative, a human health risk characterization was performed using toxicological and exposure values typical of space operations and crew. This risk characterization showed that the greatest acute waterborne health concern was from microbial infection leading to incapacitating gastrointestinal illness. Ingestion exposure pathways for toxic materials yielded de minimus acute health risks unlikely to affect SEI space missions. Risks of chronic health problems were within acceptable public health limits. Our analysis indicates that current Space Station Freedom maximum contamination levels may be unnecessarily strict. We propose alternative environmental contaminant values consistent with both acceptable short and long-term crew health safety.

Macler, Bruce A.↗

Liquid draining shut-off induced geyser and slosh wave excitation at suction dip during draining in microgravity

The dynamical behavior of vapor ingestion, liquid residual at the incipience of suction dip, liquid hydrogen shut-off at the incipience of suction dip, and slosh wave excitation under normal and various reduced gravity environments and different flow rates of liquid during draining have been investigated. It shows that the liquid residual at the incipience of suction dip increases as the values of gravity environment decrease from normal gravity to lower reduced gravity, and also that the liquid residual increases as the flow rates of liquid increase during the courses of liquid hydrogen draining. It also shows that slosh waves accompanied by strong geyser are developed for surge-related flowfields at the moment of liquid hydrogen shut-off. Slosh wave excitation, during the liquid hydrogen shut-off, shift the fluid mass distribution in the container which imposes time-dependent variation in spacecraft moment of inertia.

Hung, R. J.↗

EOSDIS/DADS requirements

A brief summary of the Earth Observing System Data and Information System (EOSDIS) Core System (ECS) Data Archive and Distribution System (DADS) requirements is given. Among the requirements are the following: the ECS relationship to EOSDIS Version-O; phased implementation of ECS; and data ingest, archive, and distribution daily data volumes anticipated at each of the 7 Distributed Active Archive Centers (DAAC's).

Berbert, John↗

A three channel telemetry system

A three channel telemetry system intended for biomedical applications is described. The transmitter is implemented in a single chip using a 2 micron BiCMOS processes. The operation of the system and the test results from the latest chip are discussed. One channel is always dedicated to temperature measurement while the other two channels are generic. The generic channels carry information from transducers that are interfaced to the system through on-chip general purpose operational amplifiers. The generic channels have different bandwidths: one from dc to 250 Hz and the other from dc to 1300 Hz. Each generic channel modulates a current controlled oscillator to produce a frequency modulated signal. The two frequency modulated signals are summed and used to amplitude modulate the temperature signal which acts as a carrier. A near-field inductive link telemeters the combined signals over a short distance. The chip operates on a supply voltage anywhere from 2.5 to 3.6 Volts and draws less than 1 mA when transmitting a signal. The chip can be incorporated into ingestible, implantable and other configurations. The device can free the patient from tethered data collection systems and reduces the possibility of infection from subcutaneous leads. Data telemetry can increase patient comfort leading to a greater acceptance of monitoring.

Lesho, Jeffery C.↗

SUMS experiment flight results on STS-35

Calibrated pressure measurements for species with mass to charge ratios up to 50 amu/e(-) were obtained from the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) experiment during reentry on the STS-35 mission. Data were collected from 180 km, when the signal rose above the background, to about 87 km, when the SUMS system automatically closed the gas inlet value. However, data above 115 km was contaminated from a source of gas emanating from pressure transducers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data is compared with the mass spectrometer total pressure with excellent agreement. The free-stream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. standard atmosphere model, exhibits the wave-like nature seen on previous flights using accelerometry. In addition, selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump. An analysis of the spectra data from this event is presented to show that no significant permanent changes occurred which affected the data interpretation at lower altitudes. Further, the localized chemistry from the individual species during the onset of aerodynamic heating is examined to the extent possible for a closed source system, such as SUMS. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions with the carbon panels of the Orbiter and absorbed oxygen on the system tubing.

Blanchard, Robert C.↗

Comparison of total body water estimates from O-18 and bioelectrical response prediction equations

Identification of an indirect, rapid means to measure total body water (TBW) during space flight may aid in quantifying hydration status and assist in countermeasure development. Bioelectrical response testing and hydrostatic weighing were performed on 27 subjects who ingested O-18, a naturally occurring isotope of oxygen, to measure true TBW. TBW estimates from three bioelectrical response prediction equations and fat-free mass (FFM) were compared to TBW measured from O-18. A repeated measures MANOVA with post-hoc Dunnett's Test indicated a significant (p less than 0.05) difference between TBW estimates from two of the three bioelectrical response prediction equations and O-18. TBW estimates from FFM and the Kushner & Schoeller (1986) equation yielded results that were similar to those given by O-18. Strong correlations existed between each prediction method and O-18; however, standard errors, identified through regression analyses, were higher for the bioelectrical response prediction equations compared to those derived from FFM. These findings suggest (1) the Kushner & Schoeller (1986) equation may provide a valid measure of TBW, (2) other TBW prediction equations need to be identified that have variability similar to that of FFM, and (3) bioelectrical estimates of TBW may prove valuable in quantifying hydration status during space flight.

Barrows, Linda H.↗