Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

TH-E-17A-05: Optimizing Four Dimensional Cone Beam Computed Tomography Projection Allocation to Respiratory Bins

Purpose: Four dimensional cone beam computed tomography (4DCBCT) is an emerging image guidance strategy but it can suffer from poor image quality. To avoid repeating scans it is beneficial to make the best use of the imaging data obtained. For conventional 4DCBCT the location and size of respiratory bins is fixed and projections are allocated to the respiratory bin within which it falls. Strictly adhering to this rule is unnecessary and can compromise image quality. In this study we optimize the size and location of respiratory bins and allow projections to be sourced from adjacent phases of the respiratory cycle. Methods: A mathematical optimization framework using mixed integer quadratic programming has been developed that determines when to source projections from adjacent respiratory bins and optimizes the size and location of the bins. The method, which we will call projection sharing, runs in under 2 seconds of CPU time. Five 4DCBCT datasets of stage III-IV lung cancer patients were used to test the algorithm. The standard deviation of the angular separation between projections (SD-A) and the standard deviation in the volume of the reconstructed fiducial gold coil (SD-V) were used as proxies to measure streaking artefacts and motion blur respectively. Results: The SD-A using displacement binning and projection sharing was 30%–50% smaller than conventional phase based binning and 59%–76% smaller than conventional displacement binning indicating more uniformly spaced projections and fewer streaking artefacts. The SD-V was 20–90% smaller when using projection sharing than using conventional phase based binning suggesting more uniform marker segmentation and less motion blur. Conclusion: Image quality was visibly and significantly improved with projection sharing. Projection sharing does not require any modifications to existing hardware and offers a more robust replacement to phase based binning, or, an option if phase based reconstruction is not of a suitable quality. This project is supported by an NHMRC Australia Fellowship and NHMRC project grant number 1034060.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-11: Evaluation of Fully Automatic Volumetric GBM Segmentation in the TCGA-GBM Dataset: Prognosis and Correlation with VASARI Features

Purpose: Reproducible definition and quantification of imaging biomarkers is essential. We evaluated a fully automatic MR-based segmentation method by comparing it to manually defined sub-volumes by experienced radiologists in the TCGA-GBM dataset, in terms of sub-volume prognosis and association with VASARI features. Methods: MRI sets of 67 GBM patients were downloaded from the Cancer Imaging archive. GBM sub-compartments were defined manually and automatically using the Brain Tumor Image Analysis (BraTumIA), including necrosis, edema, contrast enhancing and non-enhancing tumor. Spearman’s correlation was used to evaluate the agreement with VASARI features. Prognostic significance was assessed using the C-index. Results: Auto-segmented sub-volumes showed high agreement with manually delineated volumes (range (r): 0.65 – 0.91). Also showed higher correlation with VASARI features (auto r = 0.35, 0.60 and 0.59; manual r = 0.29, 0.50, 0.43, for contrast-enhancing, necrosis and edema, respectively). The contrast-enhancing volume and post-contrast abnormal volume showed the highest C-index (0.73 and 0.72), comparable to manually defined volumes (p = 0.22 and p = 0.07, respectively). The non-enhancing region defined by BraTumIA showed a significantly higher prognostic value (CI = 0.71) than the edema (CI = 0.60), both of which could not be distinguished by manual delineation. Conclusion: BraTumIA tumor sub-compartments showed higher correlation with VASARI data, and equivalent performance in terms of prognosis compared to manual sub-volumes. This method can enable more reproducible definition and quantification of imaging based biomarkers and has a large potential in high-throughput medical imaging research.

60 APPLIED LIFE SCIENCES↗

The Effect of Membrane Casting Irregularities on Initial Fuel Cell Performance

Membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) may possess as-manufactured non-uniformities in any of its constituent components. This article studies casting irregularities located within the PEM to understand their potential impact on MEA initial performance. Membrane material was cast on a lab-scale polymer casting line operating either within or at the boundaries of the process window. The resulting membrane material was either pristine in the former case, or, in the latter case, contained air bubbles, cracks, and other irregularities, ranging in size from about 0.6 to 3 mm. Spatial polarization experiments were conducted using a 121-channel segmented fuel cell system, and thermal imaging was performed subsequently to map hydrogen crossover to spatial performance. While total-cell polarization data was minimally impacted by the irregularities, the spatial diagnostics showed local performance impacts that, in operation over time, could cause degradation in performance or earlier failure of the MEA. Such impacts could lead to these irregularities being classified as defects, i.e., manufacturing variations that should be identified and not included in a fuel cell stack. Classification of irregularities as defects will ultimately assist the industry by contributing to the development of threshold detection limits for in-line quality control diagnostics.

30 DIRECT ENERGY CONVERSION↗

An intensity-based post-processing tool for 3D instance segmentation of organelles in soft X-ray tomograms

Investigating the 3D structures and rearrangements of organelles within a single cell is critical for better characterizing cellular function. Imaging approaches such as soft X-ray tomography have been widely applied to reveal a complex subcellular organization involving multiple inter-organelle interactions. However, 3D segmentation of organelle instances has been challenging despite its importance in organelle characterization. Here we propose an intensity-based post-processing tool to identify and separate organelle instances. Our tool separates sphere-like (insulin vesicle) and columnar-shaped organelle instances (mitochondrion) based on the intensity of raw tomograms, semantic segmentation masks, and organelle morphology. We validate our tool using synthetic tomograms of organelles and experimental tomograms of pancreatic β -cells to separate insulin vesicle and mitochondria instances. As compared to the commonly used connected regions labeling, watershed, and watershed + Gaussian filter methods, our tool results in improved accuracy in identifying organelles in the synthetic tomograms and an improved description of organelle structures in β -cell tomograms. In addition, under different experimental treatment conditions, significant changes in volumes and intensities of both insulin vesicle and mitochondrion are observed in our instance results, revealing their potential roles in maintaining normal β -cell function. Our tool is expected to be applicable for improving the instance segmentation of other images obtained from different cell types using multiple imaging modalities.

59 BASIC BIOLOGICAL SCIENCES↗

A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem, we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress the illusory artifacts caused by the deficiency in valid data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

SU-E-P-13: Quantifying the Geometric Error Due to Irregular Motion in Four-Dimensional Computed Tomography (4DCT)

Purpose: Respiratory correlated 4DCT images are generated under the assumption of a regular breathing cycle. This study evaluates the error in 4DCT-based target position estimation in the presence of irregular respiratory motion. Methods: A custom-made programmable externally-and internally-deformable lung motion phantom was placed inside the CT bore. An abdominal pressure belt was placed around the phantom to mimic clinical 4DCT acquisitio and the motion platform was programmed with a sinusoidal (±10mm, 10 cycles per minute) motion trace and 7 motion traces recorded from lung cancer patients. The same setup and motion trajectories were repeated in the linac room and kV fluoroscopic images were acquired using the on-board imager. Positions of 4 internal markers segmented from the 4DCT volumes were overlaid upon the motion trajectories derived from the fluoroscopic time series to calculate the difference between estimated (4DCT) and “actual” (kV fluoro) positions. Results: With a sinusoidal trace, absolute errors of the 4DCT estimated markers positions vary between 0.78mm and 5.4mm and RMS errors are between 0.38mm to 1.7mm. With irregular patient traces, absolute errors of the 4DCT estimated markers positions increased significantly by 100 to 200 percent, while the corresponding RMS error values have much smaller changes. Significant mismatches were frequently found at peak-inhale or peak-exhale phase. Conclusion: As expected, under conditions of well-behaved, periodic sinusoidal motion, the 4DCT yielded much better estimation of marker positions. When an actual patient trace is used 4DCT-derived positions showed significant mismatches with the fluoroscopic trajectories, indicating the potential for geometric and therefore dosimetric errors in the presence of cycle-to-cycle respiratory variations.

60 APPLIED LIFE SCIENCES↗

Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary.

60 APPLIED LIFE SCIENCES↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unsupervised Azimuth Estimation of Solar Arrays in Low-Resolution Satellite Imagery through Semantic Segmentation and Hough Transform

This paper explains the use of a convolutional neural network (CNN) to segment solar panels in a satellite image containing solar arrays, and extract associated metadata from the arrays. A novel unsupervised technique is introduced to estimate the azimuth of each individual solar panel from the predicted mask of the convolutional neural network. This pipeline was developed with the aim of extracting necessary metadata for a solar installation, using only a set of latitude–longitude coordinates. Azimuth prediction results for 669 individual solar installations associated with 387 sites located across the United States are provided. A mean average error and median average error of 21.65 degrees and 1.0 degrees were obtained, respectively, when predicting the azimuth of the solar fleet data set, with about 80% of the results within an error of zero degrees of the ground truth azimuth value and about 85% within an error of 25 degrees. The predicted azimuth was then used to estimate the energy conversion of the solar arrays. Results show a 90.9 and 90.6 R-squared value for estimating alternating current (AC) and direct current (DC) energy, respectively, and a mean absolute percentage error (MAPE) of 1.70% in estimating the alternating current (AC) energy using the fully automated algorithm.

14 SOLAR ENERGY↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep medical image analysis with representation learning and neuromorphic computing

Deep learning is increasingly used in medical imaging, improving many steps of the processing chain, from acquisition to segmentation and anomaly detection to outcome prediction. Yet significant challenges remain: (i) image-based diagnosis depends on the spatial relationships between local patterns, something convolution and pooling often do not capture adequately; (ii) data augmentation, the de facto method for learning three-dimensional pose invariance, requires exponentially many points to achieve robust improvement; (iii) labelled medical images are much less abundant than unlabelled ones, especially for heterogeneous pathological cases; and (iv) scanning technologies such as magnetic resonance imaging can be slow and costly, generally without online learning abilities to focus on regions of clinical interest. To address these challenges, novel algorithmic and hardware approaches are needed for deep learning to reach its full potential in medical imaging.

60 APPLIED LIFE SCIENCES↗

An Application of Faster R-CNNs in Object Detection Efforts Applied to the Critical Infrastructure Domain

Object detection and segmentation approaches have been successfully applied to multiple interdisciplinary domains ranging from medical imaging to autonomous vehicles. The following study details efforts to apply segmentation methods to the critical infrastructure domain. Specifically, the identification of critical sub-components of four facilities: airports, hospitals, hydroelectric dams, and water treatment plants. Data for this study was extracted from the U.S. Department of Agriculture’s National Agriculture Imagery Program data set. Each facility class was considered independently of the other facilities, producing four different segmentation models during the testing and training process. Ultimately, the study team concluded there are significant challenges associated with object detection modeling when applied to facility analysis within the critical infrastructure domain. The study team was able to identify possible sources of these challenges that could be potentially addressed in future work.

97 MATHEMATICS AND COMPUTING↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm

Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymph nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% {+-} 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗