Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

TU-F-CAMPUS-T-04: Variations in Nominally Identical Small Fields From Photon Jaw Reproducibility and Associated Effects On Small Field Dosimetric Parameters

Purpose: To investigate uncertainties in small field output factors and detector specific correction factors from variations in field size for nominally identical fields using measurements and Monte Carlo simulations. Methods: Repeated measurements of small field output factors are made with the Exradin W1 (plastic scintillation detector) and the PTW microDiamond (synthetic diamond detector) in beams from the Elekta Precise linear accelerator. We investigate corrections for a 0.6x0.6 cm{sup 2} nominal field size shaped with secondary photon jaws at 100 cm source to surface distance (SSD). Measurements of small field profiles are made in a water phantom at 10 cm depth using both detectors and are subsequently used for accurate detector positioning. Supplementary Monte Carlo simulations with EGSnrc are used to calculate the absorbed dose to the detector and absorbed dose to water under the same conditions when varying field size. The jaws in the BEAMnrc model of the accelerator are varied by a reasonable amount to investigate the same situation without the influence of measurements uncertainties (such as detector positioning or variation in beam output). Results: For both detectors, small field output factor measurements differ by up to 11 % when repeated measurements are made in nominally identical 0.6x0.6 cm{sup 2} fields. Variations in the FWHM of measured profiles are consistent with field size variations reported by the accelerator. Monte Carlo simulations of the dose to detector vary by up to 16 % under worst case variations in field size. These variations are also present in calculations of absorbed dose to water. However, calculated detector specific correction factors are within 1 % when varying field size because of cancellation of effects. Conclusion: Clinical physicists should be aware of potentially significant uncertainties in measured output factors required for dosimetry of small fields due to field size variations for nominally identical fields.

07 ISOTOPE AND RADIATION SOURCES↗

ORNL Neutron Cross Section Measurements of 90 Zr

Nuclear criticality modeling and simulations rely on the quality of the existing evaluated nuclear data libraries such as Evaluated Nuclear Data File (ENDF)/B, the Joint Evaluated Fission and Fusion (JEFF) nuclear data library, or the Japanese Evaluated Nuclear Data Library (JENDL). In some cases, the cross-section evaluations of those libraries were found to be deficient in describing criticality benchmarks accurately. More than two decades ago, the US Nuclear Criticality Safety Program (NCSP) established a Nuclear Data (ND) task which encompassed experiments and evaluations. In response to this, the Oak Ridge National Laboratory (ORNL) formed a Nuclear Criticality and Data group which performed ND experiments, data analysis, and evaluations to produce ENDF files for the ND libraries as identified in the NCSP Five-Year Plan. Before being submitted to the ENDF library, files were processed and tested for performance by running benchmark calculations. This procedure was centralized in the ORNL group and is now often referred to as the ND pipeline. NCSP collaborates with the Joint Research Center (JRC) of the European Commission in Geel, Belgium, to perform high-resolution neutron-induced cross section measurements at the Geel Linear Accelerator (GELINA). The objective is to address emerging ND problems in criticality calculations. Difficulties with ND include insufficient neutron energy range, missing covariances, and previously unrecognized inaccuracies with experiments. New neutron total and capture cross sections of 90 Zr in the neutron energy range from 100 eV to several hundred keV were recently performed. These measured data will be used, together with existing high-resolution transmission data from a metallic 90 Zr sample, to improve representation of the cross sections.

97 MATHEMATICS AND COMPUTING↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

60 APPLIED LIFE SCIENCES↗

Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams

Purpose: For commercially available linear accelerators (Linacs), the electron energies of flattening filter free (FFF) and flattened (FF) beams are either identical or the electron energy of the FFF beam is increased to match the percentage depth dose curve (PDD) of the FF beam (in reference geometry). This study focuses on the primary dose components of FFF beams for both kinds of settings, studied on the same Linac. Methods: The measurements were conducted on a VersaHD Linac (Elekta, Crawley, UK) for both FF and FFF beams with nominal energies of 6 and 10 MV. In the clinical setting of the VersaHD, the energy of FFF{sub M} (Matched) beams is set to match the PDDs of the FF beams. In contrast the incident electron beam of the FFF{sub U} beam was set to the same energy as for the FF beam. Half value layers (HVLs) and a dual parameter beam quality specifier (DPBQS) were determined. Results: For the 6 MV FFF{sub M} beam, HVL and DPBQS values were very similar compared to those of the 6 MV FF beam, while for the 10 MV FFF{sub M} and FF beams, only %dd(10){sub x} and HVL values were comparable (differences below 1.5%). This shows that matching the PDD at one depth does not guarantee other beam quality dependent parameters to be matched. For FFF{sub U} beams, all investigated beam quality specifiers were significantly different compared to those for FF beams of the same nominal accelerator potential. The DPBQS of the 6 MV FF and FFF{sub M} beams was equal within the measurement uncertainty and was comparable to published data of a machine with similar TPR{sub 20,10} and %dd(10){sub x}. In contrast to that, the DPBQS’s two parameters of the 10 MV FFF{sub M} beam were substantially higher compared to those for the 10 MV FF beam. Conclusions: PDD-matched FF and FFF beams of both nominal accelerator potentials were observed to have similar HVL values, indicating similarity of their primary dose components. Using the DPBQS revealed that the mean attenuation coefficient was found to be the same within the uncertainty of 0.8% for 6 MV FF and 6 MV FFF{sub M} beams, while for 10 MV beams, they differed by 6.4%. This shows that the DPBQS can provide a differentiation of photon beam characteristics that would remain hidden by the use of a single beam quality specifier, such as %dd(10){sub x} or HVL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam

A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere with signals transmitted through the fiber. We determine the spectrum of the Cerenkov background signal generated in a poly(methyl methacrylate) optical fiber exposed to photon and electron therapeutic beams from a linear accelerator. This spectral measurement is relevant to discrimination of the signal from the background, as in scintillation dosimetry using optical fiber readouts. We find that the spectrum is approximated by the theoretical curve after correction for the wavelength dependent attenuation of the fiber. The spectrum does not depend significantly on the angle between the radiation beam and the axis of the fiber optic but is dependent on the depth in water at which the fiber is exposed to the beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-JeP2-04: Comparison Between Fricke-Type 3D Radiochromic Dosimeters for Real-Time Dose Distribution Measurements in MR-Guided Radiation Therapy

Purpose: To assess MR signal contrast for different ferrous ion compounds used in Fricke-type gel dosimeters for real-time dose measurements for MR-guided radiation therapy applications. Methods: Fricke-type gel dosimeters were prepared in 4% w/w gelatin prior to irradiation in an integrated 1.5 T MRI and 7 MV linear accelerator system (MR-Linac). 4 different ferrous ion (Fe2?) compounds (referred to as A, B, C, and D) were investigated for this study. Dosimeter D consisted of ferrous ammonium sulfate (FAS), which is conventionally used for Fricke dosimeters. Approximately half of each cylindrical dosimeter (45 mm diameter, 80 mm length) was irradiated to ∼17 Gy. MR imaging during irradiation was performed with the MR-Linac using a balanced-FFE sequence of TR/TE = 5/2.4 ms. An approximate uncertainty of 5% in our dose delivery was anticipated since the MR-Linac had not yet been fully commissioned. Results: The signal intensities (SI) increased between the un-irradiated and irradiated regions by approximately 8.6%, 4.4%, 3.2%, and 4.3% after delivery of ∼2.8 Gy for dosimeters A, B, C, and D, respectively. After delivery of ∼17 Gy, the SI had increased by 24.4%, 21.0%, 3.1%, and 22.2% compared to the un-irradiated regions. The increase in SI with respect to dose was linear for dosimeters A, B, and D with slopes of 0.0164, 0.0251, and 0.0236 Gy{sup −1} (R{sup 2} = 0.92, 0.97, and 0.96), respectively. Visually, dosimeter A had the greatest optical contrast from yellow to purple in the irradiated region. Conclusion: This study demonstrated the feasibility of using Fricke-type dosimeters for real-time dose measurements with the greatest optical and MR contrast for dosimeter A. We also demonstrated the need to investigate Fe{sup 2+} compounds beyond the conventionally utilized FAS compound in order to improve the MR signal contrast in 3D dosimeters used for MR-guided radiation therapy. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship Program under Grant No. LH- 102SPS.

60 APPLIED LIFE SCIENCES↗

Nucleon Form Factors from BLAST

The BLAST (Bates Large Acceptance Spectrometer Toroid) experiment has been carried out at the MIT-Bates Linear Accelerator Center to study spin-dependent electron scattering from protons and deuterons with small systematic uncertainties. The experiment used a longitudinally polarized, intense electron beam stored in the Bates South Hall Ring in combination with isotopically pure, highly-polarized internal targets of polarized hydrogen and vector- and tensor-polarized deuterium from an atomic beam source. The BLAST data have been used to extract precise results for the elastic form factor ratios G{sub E}/G{sub M} of the proton and the neutron at low momentum transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-D-BRD-01: Image Guided SBRT II: Challenges ' Pitfalls

Stereotactic body radiation therapy (SBRT) has been effective treatment for the management of various diseases, which often delivers high radiation dose in a single or a few fractions. SBRT therefore demands precise treatment delivery to the tumor while sparing adjacent healthy tissue. Recent developments in image guidance enable target localization with increased accuracy. With such improvements in localization, image-guided SBRT has been widely adopted into clinical practice. In SBRT, high radiation dose is generally delivered with small fields. Therefore, it is crucial to accurately measure dosimetric data for the small fields during commissioning. In addition, image-guided SBRT demands accurate image localization to ensure safety and quality of patient care. Lately, the reports of AAPM TG 142 and TG 104 have been published and added recommendations for imaging devices that are integrated with the linear accelerator for SBRT. Furthermore, various challenges and potential pitfalls lie in the clinical implementation of image-guided SBRT. In this lecture, these challenges and pitfalls of image-guided SBRT will be illustrated and discussed from dosimetric, technical and clinical perspectives.Being a promising technique, image-guided SBRT has shown great potentials, and will lead to more accurate and safer SBRT treatments. Learning Objectives: To understand dosimetric challenges and pitfalls for IGRT application in SBRT. To understand major clinical challenges and pitfalls for IGRT application in SBRT. To understand major technical challenges and pitfalls for IGRT application in SBRT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-679: Retrospective Analysis of the Sensitivity of Planar Dose Measurements To Gamma Analysis Criteria

Purpose: IMRT QA using planar dose measurements is still a widely used method for checking the accuracy of treatment plans. A pass/fail judgment is made using gamma analysis based on a single endpoint. Using more stringent criteria is a way to increase the sensitivity to planning and delivery errors. Before such implementation, it is necessary to understand how the sensitivity to different gamma criteria settings affects gamma passing rates (GPR). Methods: 752 IMRT QA measurements were re-analyzed with varying distance to agreement (DTA) and dose difference (DD) percentages using a Matlab program. Other quantifying information such as the mean dose difference in the treatment target (defined as points that are greater than 80% of maximal dose) were stored in a relational database for retrospective analysis. Results: The average and standard deviation of GPR (%) fell from 99.84 ± (0.43) to 89.61 ± (6.08) when restricting DD from 5 − 1% respectively, as compared to a drop from 99.15 ± (1.19) to 95.00 ± (4.43), when restricting the DTA from 5 − 1 mm respectively. The mean dose difference (%) in the treatment target between measured and calculated dose was −1.96 ± (0. 83), −0.09 ± (0.98), and 1.44 ± (0. 86) for each of our institution’s three matched linear accelerators (LINAC 1, 2, and 3 respectively). For plans that are approximately 2.7 sigma below the mean GPR, an average of 78.4% of those plans were measured on LINAC 1 or 3, while only 48% of the total plans were run on those machines. Conclusion: The data demonstrates that when restricting gamma criterion, such as the DD, the greatest indicator of reduced GPR in our institution is which matched LINAC the plan was measured on. While small, these differences manifest themselves to levels comparable to other treatment related differences and possibly confound the gamma analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Imaging of Radiation Dose for Stereotactic Radiosurgery

The distributions of radiation dose for stereotactic radiosurgery, using a modified linear accelerator (Philips SL-25 and SRS-200), have been studied by using three different dosimeters: (1) ferrous-agarose-xylenol orange (FAX) gels, (2) TLD, and (3) thick-emulsion GafChromic dye film. These dosimeters were loaded into a small volume of defect in a phantom head. A regular linac stereotactic radiosurgery treatment was then given to the phantom head for each type of dosimeter. The measured radiation dose and its distributions were found to be in good agreement with those calculated by the treatment planning computer.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Simple Approach to the Technical Aspects of Radiosurgery Treatments

An approach to radiosurgery treatment that can be readily adopted in most radiotherapy centers with linear accelerators is presented. In our institution, a Leksell-type of neurosurgical frame, a computed tomography scanner, locally fabricated cones, and 6 MV X-ray beams are used to perform radiosurgery treatments. Collimated arcs with dose distributions that conform to the shape of the lesion in the transverse and the sagittal planes are used. It is argued that the uncertainties in the localization of the isocenter within a lesion and the specifications of the size of the target volume do not justify high precision mechanical devices for most radiosurgery treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu{sup 2+} storage phosphor detectors

Purpose: The activator ion (Eu{sup 2+} in KCl:Eu{sup 2+}) plays an important role in the photostimulated luminescence (PSL) mechanism of storage phosphor radiation detectors. In order to design an accurate, effective, and robust detector, it is important to understand how the activator ion concentration affects the structure and, consequently, radiation detection properties of KCl:Eu{sup 2+}.Methods: Potassium chloride pellets were fabricated with various amounts of europium dopant (0.01–5.0 mol.% Eu{sup 2+}). Clinical radiation doses were given with a 6 MV linear accelerator. Radiation doses larger than 100 Gy were given with a {sup 137}Cs irradiator. Dose response curves, radiation hardness, and temporal signal stability were measured using a laboratory PSL readout system. The crystal structure of the material was studied using x ray diffraction and luminescence spectroscopy.Results: The most intense PSL signal was from samples with 1.0 mol.% Eu. However, samples with concentrations higher than 0.05 mol.% Eu exhibited significant degradation in PSL intensity for cumulated doses larger than 3000 Gy. Structural and luminescence spectroscopy showed clear evidence of precipitate phases within the KCl lattice, especially for high activator concentrations. Analysis of PL emission spectra showed that interactions between Eu-V{sub c} dipoles and Eu-V{sub c} trimers could explain trends in PSL sensitivity and radiation hardness observations.Conclusions: The concentration of the activator ion (Eu{sup 2+}) significantly affects radiation detection properties of the storage phosphor KCl:Eu{sup 2+}. An activator concentration between 0.01 and 0.05 mol.% Eu in KCl:Eu{sup 2+} storage phosphor detectors is recommended for linear dose response, good PSL sensitivity, predictable temporal stability, and high reusability for megavoltage radiation detection.

36 MATERIALS SCIENCE↗

Sci—Fri AM: Mountain — 05: Unified Optimization and Delivery of Intensity-modulated Radiation Therapy and Volume-modulated Arc Therapy

Purpose: To study the feasibility of a unified intensity-modulated arc therapy (UIMAT) that combines IMRT and VMAT optimization and delivery in order to produce efficient and superior radiation treatment plans. Methods: Inverse planning for UIMAT was prototyped on the Pinnacle treatment planning system (Philips Medical Systems). UIMAT integrates IMRT and VMAT delivery in the same arc where IMRT was delivered with gantry speed close to zero. Optimal gantry angles for the IMRT phases were selected automatically by the inverse optimization algorithm. Optimization of the VMAT phases and IMRT phases were done simultaneously using Pinnacle's direct machine parameter optimization algorithm. Five treatment plans each for prostate, head and neck, and lung were generated using our unified technique and compared with clinical VMAT or IMRT plans. Delivery verification was performed on an ArcCheck phantom (Sun Nuclear) and delivered in clinical mode on a Varian TrueBeam linear accelerator. Results: In this prototype implementation, compared to the VMAT or IMRT plans, with the plans normalized to the same dose coverage to the planning target volumes, the UIMAT plans produced improved OAR sparing for head and neck cases, while for lung and prostate cases, the dosimetric improvements for OARs were not as significant. In this proof-of-concept work, we demonstrated that a novel radiation therapy delivery technique combining VMAT and IMRT delivery in the same arc is feasible. Initial results showed UIMAT has the potential to be superior to either standard IMRT or VMAT.

60 APPLIED LIFE SCIENCES↗

Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac

Purpose: Due to the close proximity of the linear accelerator (linac) to the magnetic resonance (MR) imager in linac-MR systems, it will be subjected to magnet fringe fields larger than the Earth's magnetic field of 5x10{sup -5} T. Even with passive or active shielding designed to reduce these fields, some magnitude of the magnetic field is still expected to intersect the linac, causing electron deflection and beam loss. This beam loss, resulting from magnetic fields that cannot be eliminated with shielding, can cause a detuning of the waveguide due to excessive heating. The detuning, if significant, could lead to an even further decrease in output above what would be expected strictly from electron deflections caused by an external magnetic field. Thus an investigation of detuning was performed through various simulations. Methods: According to the Lorentz force, the electrons will be deflected away from their straight course to the target, depositing energy as they impact the linac copper waveguide. The deposited energy would lead to a heating and deformation of the copper structure resulting in resonant frequency changes. PARMELA was used to determine the mean energy and fraction of total beam lost in each linac cavity. The energy deposited into the copper waveguide from the beam losses caused by transverse magnetic fields was calculated using the Monte Carlo program DOSRZnrc. From the total energy deposited, the rise in temperature and ultimately the deformation of the structure was estimated. The deformed structure was modeled using the finite element method program COMSOL MULTIPHYSICS to determine the change in cavity resonant frequency. Results: The largest changes in resonant frequency were found in the first two accelerating cavities for each field strength investigated. This was caused by a high electron fluence impacting the waveguide inner structures coupled with their low kinetic energies. At each field strength investigated, the total change in accelerator frequency was less than a manufacturing tolerance of 10 kHz and is thus not expected to have a noticeable effect on accelerator performance. Conclusions: The amount of beam loss caused by magnetic fringe fields for a linac in a linac-MR system depends on the effectiveness of its magnetic shielding. Despite the best efforts to shield the linac from the magnetic fringe fields, some persistent magnetic field is expected which would result in electron beam loss. This investigation showed that the detuning of the waveguide caused by additional electron beam loss in persistent magnetic fields is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-111: Investigation of the Attila Deterministic Solver as a Supplement to Monte Carlo for Calculating Out-Of-Field Radiotherapy Dose

Purpose: To use the Attila deterministic solver as a supplement to Monte Carlo for calculating out-of-field organ dose in support of epidemiological studies looking at the risks of second cancers. Supplemental dosimetry tools are needed to speed up dose calculations for studies involving large-scale patient cohorts. Methods: Attila is a multi-group discrete ordinates code which can solve the 3D photon-electron coupled linear Boltzmann radiation transport equation on a finite-element mesh. Dose is computed by multiplying the calculated particle flux in each mesh element by a medium-specific energy deposition cross-section. The out-of-field dosimetry capability of Attila is investigated by comparing average organ dose to that which is calculated by Monte Carlo simulation. The test scenario consists of a 6 MV external beam treatment of a female patient with a tumor in the left breast. The patient is simulated by a whole-body adult reference female computational phantom. Monte Carlo simulations were performed using MCNP6 and XVMC. Attila can export a tetrahedral mesh for MCNP6, allowing for a direct comparison between the two codes. The Attila and Monte Carlo methods were also compared in terms of calculation speed and complexity of simulation setup. A key perquisite for this work was the modeling of a Varian Clinac 2100 linear accelerator. Results: The solid mesh of the torso part of the adult female phantom for the Attila calculation was prepared using the CAD software SpaceClaim. Preliminary calculations suggest that Attila is a user-friendly software which shows great promise for our intended application. Computational performance is related to the number of tetrahedral elements included in the Attila calculation. Conclusion: Attila is being explored as a supplement to the conventional Monte Carlo radiation transport approach for performing retrospective patient dosimetry. The goal is for the dosimetry to be sufficiently accurate for use in retrospective epidemiological investigations.

60 APPLIED LIFE SCIENCES↗