Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Progress on detection of liquid explosives using ultra-low field MRI

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) methods are widely used in medicine, chemistry and industry. Over the past several years there has been increasing interest in performing NMR and MRI in the ultra-low field (ULF) regime, with measurement field strengths of 10-100 microTesla and pre-polarization fields of 30-50 mTesla. The real-time signal-to-noise ratio for such measurements is about 100. Our group at LANL has built and demonstrated the performance of SQUID-based ULF NMR/MRI instrumentation for classification of materials and detection of liquid explosives via their relaxation properties measured at ULF, using T{sub 1}, and T{sub 2}, and T{sub 1} frequency dispersion. We are also beginning to investigate the performance of induction coils as sensors. Here we present recent progress on the applications of ULF MR to the detection of liquid explosives, in imaging and relaxometry.

42 ENGINEERING↗

Magnetic, Mechanical and Thermal Modeling of Superconducting, Whole-Body, Actively Shielded, 3 T MRI Magnets Wound Using MgB 2 Strands for Liquid Cryogen Free Operation

Here we present magnetic, mechanical and thermal modeling results for a 3 Tesla actively shielded whole body MRI (Magnetic Resonance Imaging) magnet consisting of coils with a square cross section of their windings. The magnet design was a segmented coil type optimized to minimize conductor length while hitting the standard field quality and DSV (Diameter of Spherical Volume) specifications as well as a standard, compact size 3 T system. It had an overall magnet length and conductor length which can lead to conduction cooled designs comparable to NbTi helium bath cooled 3 T MRI magnets. The design had a magnetic field homogeneity better than 10 ppm (part-per-million) within a DSV (Diameter of Spherical Volume) of 48 cm and the total magnet winding length of 1.37 m. A new class of MgB 2 strand especially designed for MRI applications was considered as a possible candidate for winding such magnets. This work represents the first magnetic, mechanical and thermal design for a whole-body 3 T MgB 2 short (1.37 m length) MRI magnet based on the performance parameters of existing MgB 2 wire. 3 Tesla MRI magnet can operate at 20 K at 67% of its critical current.

43 PARTICLE ACCELERATORS↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Evanescent wave decomposition in a novel resonator comprising unmagnetized and magnetized plasma layers

A 4 Multiplication-Sign 4 transfer matrix method has been applied to study the decomposition of any elliptically polarized wave in a magnetized resonator. When the incident elliptically polarized wave passes through the structure, it is orthogonally decomposed into two circular polarizations at two resonance frequencies. Without changing the structure of the resonator, the positions of the resonant frequencies of the right- and left-handed circularly polarized waves can be modulated by changing the external magnetized field. The results show that the proposed magnetized structure can be used to design a novel resonator, which can be applied in the decomposition of polarized electromagnetic waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and Resonant Properties of Fe–Bi Films

Film structures in the Fe–Bi system have been studied experimentally. The magnetic state of the two-layer structures is shown by electron magnetic resonance to be dependent on the order of depositing magnetic and nonmagnetic layers. The three-layer structures demonstrate the effect of the exchange bias, the value of which is dependent on the bismuth interlayer thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated microchip incorporating atomic magnetometer and microfluidic channel for NMR and MRI

An integral microfluidic device includes an alkali vapor cell and microfluidic channel, which can be used to detect magnetism for nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Small magnetic fields in the vicinity of the vapor cell can be measured by optically polarizing and probing the spin precession in the small magnetic field. This can then be used to detect the magnetic field of in encoded analyte in the adjacent microfluidic channel. The magnetism in the microfluidic channel can be modulated by applying an appropriate series of radio or audio frequency pulses upstream from the microfluidic chip (the remote detection modality) to yield a sensitive means of detecting NMR and MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Sequences for Hyperpolarized Solids

Hyperpolarization is one of the approaches to enhance Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) signal by increasing the population difference between the nuclear spin states. Imaging hyperpolarized solids opens up extensive possibilities, yet is challenging to perform. The highly populated state is normally not replenishable to the initial polarization level by spin-lattice relaxation, which regular MRI sequences rely on. This makes it necessary to carefully “budget” the polarization to optimize the image quality. In this paper, we present a theoretical framework to address such challenge under the assumption of either variable flip angles or a constant flip angle. In addition, we analyze the gradient arrangement to perform fast imaging to overcome intrinsic short decoherence in solids. Hyperpolarized diamonds imaging is demonstrated as a prototypical platform to test the theory.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic Mesocellular Foam Functionalized by Curcumin for Potential Multifunctional Therapeutics

The study investigates curcumin/SPIONs hybridized mesocellular foam type silica for potential dual purpose of drug delivery (curcumin) and magnetic resonance imaging. Magnetization capability and curcumin release was assessed for different structured silica such as spherical silica (Q-10), Si-MCM-41, Si-SBA-16, mesocellular foam (MSU-Foam), Si-KIT-6, ULPFDU-12, and silicalite. The phase, textural, and morphological variation was systematically scrutinized using various physico-chemical techniques. Ten weight percent SPIONs loading was found to generate magnetically active SPIONs in the following order: Q-10 (1.44 emu/g) > SBA-16 (0.80 emu/g) > MSU-Foam (0.24 emu/g) > Si-MCM-41 (0.07 emu/g) > Si-KIT-6 (0.07 emu/g) > silicalite (0.08 emu/g), respectively. The iron oxide dispersion, specific surface area, and porosity play a major role in various structured silicas. MSU-Foam with wormhole structure showed highest specific surface area occupation of SPIONs (73%). The presence of interconnected porosity of foam tends to generate external agglomeration of SPIONs (7–18 nm) at the pore surface contributing to expansion of pore sizes from 16.4 to 40.2 nm. The SPIONs over spherical micron-sized silica Q-10 showed the formation of large nanoclusters (10–25 nm). Thirty to 390 μg/ml of curcumin was loaded over silica and SPIONs/silica structured hybrid, and drug release was studied at pH 5.6 for 72 h. SPIONs/MSU-Foam with less magnetization showed the highest cumulative curcumin release (53.2%), while Q-10 spherical silica with high magnetization property showed less cumulative release of curcumin (12%).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A magnetic gradient induced force in NMR restricted diffusion experiments

We predict that the phase cancellation of a precessing magnetisation field carried by a diffusing species in a bounded geometry under certain nuclear magnetic resonance pulsed magnetic field gradient sequences results in a small force over typically micrometre length scales. Our calculations reveal that the total magnetisation energy in a pore under the influence of a pulsed gradient will be distance-dependent thus resulting in a force acting on the boundary. It is shown that this effect of the magnetisation of diffusing particles will appear as either an attractive or repulsive force depending on the geometry of the pore and magnetic properties of the material. A detailed analysis is performed for the case of a pulsed gradient spin-echo experiment on parallel planes. It is shown that the force decays exponentially in terms of the spin-spin relaxation. The proof is based on classical electrodynamics. An application of this effect to soft matter is suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which could aid in individualizing therapy, particularly for patients at risk for liver injury after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multifrequency spin resonance in diamond

Magnetic resonance techniques provide a powerful tool for controlling spin systems, with applications ranging from quantum information processing to medical imaging. Nevertheless, the behavior of a spin system under strong excitation remains a rich dynamical problem. In this paper, we examine spin resonance of the nitrogen-vacancy center in diamond under conditions outside the regime where the usual rotating-wave approximation applies, focusing on effects of multifrequency excitation and excitation with orientation parallel to the spin quantization axis. Strong-field phenomena such as multiphoton transitions and coherent destruction of tunneling are observed in the spectra and analyzed via numerical and analytic theory. In addition to illustrating the response of a spin system to strong multifrequency excitation, these observations may inform techniques for manipulating electron-nuclear spin quantum registers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prevention of disuse osteoporosis: Effect of sodium fluoride during five weeks of bed rest

An attempt was made to modify factors which promote disuse osteoporosis and thereby prevent it from occurring. Since fluoride is currently used to enhance bone formation in the treatment of low turnover osteoporosis, it was hypothesized that if the fluoride ion was available over a long period of time that it would slow the demonstrated loss of calcium by inhibiting bone resorption and enhancing bone formation. This study was used to determine whether oral medication with sodium F will modify or prevent 5 weeks of bed rest induced disuse osteoporosis, to determine the longitudinal effects of 5 weeks of bed rest on PTH, CT and calcitriol, to measure muscle volume changes and metabolic activity by magnetic resonance imaging and magnetic resonance spectroscopy during prolonged bed rest, to measure changes in peak muscle strength and fatigability, and to measure bone turnover in bone biopsies. Subjects were studied during 1 week of equilibration, 4 weeks of control ambulation, 5 weeks of bed rest, and 1 week of reambulation.

Schneider, Victor S.↗

Making Superconducting Welds between Superconducting Wires

A technique for making superconducting joints between wires made of dissimilar superconducting metals has been devised. The technique is especially suitable for fabrication of superconducting circuits needed to support persistent electric currents in electromagnets in diverse cryogenic applications. Examples of such electromagnets include those in nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) systems and in superconducting quantum interference devices (SQUIDs). Sometimes, it is desirable to fabricate different parts of a persistent-current-supporting superconducting loop from different metals. For example, a sensory coil in a SQUID might be made of Pb, a Pb/Sn alloy, or a Cu wire plated with Pb/Sn, while the connections to the sensory coil might be made via Nb or Nb/Ti wires. Conventional wire-bonding techniques, including resistance spot welding and pressed contact, are not workable because of large differences between the hardnesses and melting temperatures of the different metals. The present technique is not subject to this limitation. The present technique involves the use (1) of a cheap, miniature, easy-to-operate, capacitor-discharging welding apparatus that has an Nb or Nb/Ti tip and operates with a continuous local flow of gaseous helium and (2) preparation of a joint in a special spark-discharge welding geometry. In a typical application, a piece of Nb foil about 25 m thick is rolled to form a tube, into which is inserted a wire that one seeks to weld to the tube (see figure). The tube can be slightly crimped for mechanical stability. Then a spark weld is made by use of the aforementioned apparatus with energy and time settings chosen to melt a small section of the niobium foil. The energy setting corresponds to the setting of a voltage to which the capacitor is charged. In an experiment, the technique was used to weld an Nb foil to a copper wire coated with a Pb/Sn soft solder, which is superconducting. The joint was evaluated as part of a persistent-current circuit having an inductance of 1 mH. A current was induced in a loop, and no attenuation of the current after a time interval 1,000 s was discernible in a measurement having a fractional accuracy of 10(exp -4): This observation supports the conclusion that the weld had an electrical resistance <10(exp -10) omega.

Penanen, Konstantin I.↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytic description of atomic interaction at ultracold temperatures. II. Scattering around a magnetic Feshbach resonance

Starting from a multichannel quantum-defect theory, we derive analytic descriptions of a magnetic Feshbach resonance in an arbitrary partial wave l and the atomic interactions around it. An analytic formula, applicable to both broad and narrow resonances of arbitrary l, is presented for ultracold atomic scattering around a Feshbach resonance. Other related issues addressed include (a) the parametrization of a magnetic Feshbach resonance of arbitrary l, (b) rigorous definitions of ''broad'' and ''narrow'' resonances of arbitrary l and their different scattering characteristics, and (c) the tuning of the effective range and the generalized effective range by a magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗