Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Predictive Engineering Tools for Injection-Molded Long-Carbon-Fiber Thermoplastic Composites - FY 2016 First Quarterly Report

During the first quarter of FY 2016, the following technical progress has been made toward project milestones: 1) Virginia Tech completed fiber orientation (FO) measurements for the samples taken at Locations A, B, C and D (Figure 1) from the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed and non-ribbed complex parts using Virginia Tech’s established procedure. Virginia Tech delivered to PNNL all the measured fiber orientation data for validating ASMI fiber orientation predictions. 2)Virginia Tech performed fiber length distribution (FLD) measurements for the samples taken at Locations A, B, C and D from these complex parts using Virginia Tech’s established procedure. Virginia also re-assessed previous data and measured fiber length distributions in the corresponding nozzle purging materials and delivered to PNNL all the measured length data for validating ASMI fiber length predictions. 3)Based on measured fiber orientation data, Autodesk identified the parameters of the anisotropic rotary diffusion reduced strain closure (ARD-RSC) model [1] and provided PNNL with the values of these parameters that were used in ASMI analyses of the complex parts. 4) Magna provided Virginia Tech with additional samples cut out from the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed parts (Figure 1) for fiber length and orientation measurements. 5) In discussion with Autodesk, PNNL performed 3D ASMI analyses of the 30wt% LCF/PP and 30wt% LCF/PA66 ribbed and non-ribbed complex parts to predict fiber orientations and length distributions in these parts. The issues observed through the analyses regarding fiber orientation distributions profiles and abnormal length distributions were reported to Autodesk. Autodesk is working to resolve these issues. 6) PNNL completed 3D ASMI analyses of the complex parts and compared predicted fiber orientation results at Locations A, B, and C on the non-ribbed parts, and at Locations A, B, C and D on the ribbed parts with the corresponding measured data. PNNL also evaluated the within-15%-agreement criterion using the principal tensile and flexural moduli computed based on predicted vs. measured fiber orientation results. 7) PNNL developed and discussed with Toyota, Magna and PlastiComp a method to perform weight and cost reduction for making the 30wt% LCF/PA66 ribbed part through comparative three-point bending simulations of this part and of similar parts in steel.

36 MATERIALS SCIENCE↗

Unzipping hBN with ultrashort mid-infrared pulses

Manipulating the nanostructure of materials is critical for numerous applications in electronics, magnetics, and photonics. However, conventional methods such as lithography and laser writing require cleanroom facilities or leave residue. We describe an approach to creating atomically sharp line defects in hexagonal boron nitride (hBN) at room temperature by direct optical phonon excitation with a mid-infrared pulsed laser from free space. We term this phenomenon “unzipping” to describe the rapid formation and growth of a crack tens of nanometers wide from a point within the laser-driven region. Formation of these features is attributed to the large atomic displacement and high local bond strain produced by strongly driving the crystal at a natural resonance. This process occurs only via coherent phonon excitation and is highly sensitive to the relative orientation of the crystal axes and the laser polarization. Its cleanliness, directionality, and sharpness enable applications such as polariton cavities, phonon-wave coupling, and in situ flake cleaving.

36 MATERIALS SCIENCE↗

Response of Al-Based Micro- and Nanocomposites to Rapid Fluctuations in Thermal Environments

The focus of this work is to highlight the relative response of Al-based micro- and nanocomposites in the form of enhancement in flexural strength via induced thermal stresses at high and cryogenic temperatures in ex situ and in situ atmospheres. In this investigation, we have tried to explore the reliability, matrix-reinforcement interaction and microstructural integrity of these materials in their service period by designing appropriate heat treatment regimes. Al-Al{sub 2}O{sub 3} micro- and nanocomposites had been fabricated by powder processing method. The micro- and nanocomposites were subjected to down-thermal shock (from positive to negative temperature) and up-thermal shock (from negative to positive temperature) with varying thermal gradients. For isothermal conditioning, the composites were exposed to + 80 and − 80 °C for 1 h separately. High-temperature three-point flexural tests were performed at 100 and 250 °C on the composites. All the composites subjected to thermal shock and isothermal conditioning was tested in three-point flexural mode post-treatments. Al-1 vol.% Al{sub 2}O{sub 3} nanocomposite’s flexural strength improved to 118 MPa post-thermal shock treatment of gradient of 160 °C. The Al-5 and 10 vol.% Al{sub 2}O{sub 3} microcomposites possessed flexural strength of 200 and 99.8 MPa after thermal shock treatment of gradient of 160 and 80 °C, respectively. The observed improvement in flexural strength of micro- and nanocomposites post-thermal excursions were compared and have been discussed with the support of fractography. The microcomposites showed a higher positive scale of response to the thermal excursions as compared to that of the nanocomposites.

36 MATERIALS SCIENCE↗

Inference of the phase-to-mechanical property link via coupled X-ray spectrometry and indentation analysis: Application to cement-based materials

A novel approach for the chemo-mechanical characterization of cement-based materials is presented, which combines the classical grid indentation technique with elemental mapping by scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDS). It is illustrated through application to an oil-well cement system with siliceous filler. The characteristic X-rays of major elements (silicon, calcium and aluminum) are measured over the indentation region and mapped back on the indentation points. Measured intensities together with indentation hardness and modulus are considered in a clustering analysis within the framework of Finite Mixture Models with Gaussian component density function. The method is able to successfully isolate the calcium-silica-hydrate gel at the indentation scale from its mixtures with other products of cement hydration and anhydrous phases; thus providing a convenient means to link mechanical response to the calcium-to-silicon ratio quantified independently via X-ray wavelength dispersive spectroscopy. A discussion of uncertainty quantification of the estimated chemo-mechanical properties and phase volume fractions, as well as the effect of chemical observables on phase assessment is also included.

36 MATERIALS SCIENCE↗

Final Report: Preparation and Evaluation of N-Type CdSeTe and CdTe as an Absorber in Thin Film PV

The primary objective of this project was to demonstrate n-type CdTe and CdSeTe films prepared by in-situ doping methods using pre-doped source material. Our goal was to achieve electron density (>10 17 cm -3 ) and lifetime (>10 ns) in n-type CdTe and CdSeTe films. The focus was on indium as the dopant, as it is suitable for incorporation during melt growth of CdTe. It was thought that indium doped bulk crystals might exhibit self compensation and high resistivity, so post-growth annealing studies were planned to manipulate crystal stoichiometry, defects and electrical activity. Single crystals of CdTe:In and CdSe 0.4 Te 0.6 :In, with target In concentration 10 19 cm -3 , were grown by the vertical Bridgman crystal growth method at Washington State University (WSU). Incorporation of the intended In into the crystals was ~25%-30%, (2.5-3) ×10 18 cm -3 , according to glow discharge mass spectrometry (GDMS). Carrier concentration in CdTe:In crystals were very low until after a Cd anneal, at which point the concentration reached 8 ×10 17 cm -3 (~27% activation) according to Hall effect and time resolved photoluminescence (TRPL). CdSeTe:In, on the other hand, had ~100% carrier activation with no post-growth treatments, resulting in ~3×10 18 cm -3 carriers with a lifetime of 1.5 ns, near the radiative limit for this material.

14 SOLAR ENERGY↗

A generalized method for high throughput in-situ experiment data analysis: An example of battery materials exploration

A generalized method is introduced to extract critical information from series of ranked correlated data. The method is generally applicable to all types of spectra evolving as a function of any arbitrary parameter. This approach is based on correlation functions and statistical scedasticity formalism. Numerous challenges in analyzing high throughput experimental data can be tackled using the herein proposed method. We applied this method to understand the reactivity pathway and formation mechanism of a Li-ion battery cathode material during high temperature synthesis using in-situ highenergy X-ray diffraction. We demonstrate that Pearson's correlation function can easily unravel all major phase transition and, more importantly, the minor structural changes which cannot be revealed by conventionally inspecting the series of diffraction patterns. Furthermore, a two-dimensional (2D) reactivity pattern calculated as the scedasticity along all measured reciprocal space of all successive diffraction pattern pairs unveils clearly the structural evolution path and the active areas of interest during the synthesis. The methods described here can be readily used for on-the-fly data analysis during various in-situ operando experiments in order to quickly evaluate and optimize experimental conditions, as well as for post data analysis and large data mining where considerable amount of data hinders the feasibility of the investigation through point-by-point inspection.

25 ENERGY STORAGE↗

Patient-Specific 3D Pretreatment and Potential 3D Online Dose Verification of Monte Carlo-Calculated IMRT Prostate Treatment Plans

Purpose: Fast and reliable comprehensive quality assurance tools are required to validate the safety and accuracy of complex intensity-modulated radiotherapy (IMRT) plans for prostate treatment. In this study, we evaluated the performance of the COMPASS system for both off-line and potential online procedures for the verification of IMRT treatment plans. Methods and Materials: COMPASS has a dedicated beam model and dose engine, it can reconstruct three-dimensional dose distributions on the patient anatomy based on measured fluences using either the MatriXX two-dimensional (2D) array (offline) or a 2D transmission detector (T2D) (online). For benchmarking the COMPASS dose calculation, various dose-volume indices were compared against Monte Carlo-calculated dose distributions for five prostate patient treatment plans. Gamma index evaluation and absolute point dose measurements were also performed in an inhomogeneous pelvis phantom using extended dose range films and ion chamber for five additional treatment plans. Results: MatriXX-based dose reconstruction showed excellent agreement with the ion chamber (<0.5%, except for one treatment plan, which showed 1.5%), film ({approx}100% pixels passing gamma criteria 3%/3 mm) and mean dose-volume indices (<2%). The T2D based dose reconstruction showed good agreement as well with ion chamber (<2%), film ({approx}99% pixels passing gamma criteria 3%/3 mm), and mean dose-volume indices (<5.5%). Conclusion: The COMPASS system qualifies for routine prostate IMRT pretreatment verification with the MatriXX detector and has the potential for on-line verification of treatment delivery using T2D.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involvement of Difference in Decrease of Hemoglobin Level in Poor Prognosis of Stage I and II Nasopharyngeal Carcinoma: Implication in Outcome of Radiotherapy

Purpose: To investigate the effect of hemoglobin (Hb) concentration and the difference in its decrease during treatment on outcome of radiotherapy (RT) alone for patients with Stage I and II nasopharyngeal carcinoma. Methods and Materials: A total of 572 patients with Stage I-II nasopharyngeal carcinoma with RT alone between January 2001 and December 2004 were retrospectively analyzed. Patient characteristics, tumor variables, and Hb level, including pre-RT Hb, mid-RT Hb, and dynamic change of Hb between pre- and post- RT and its difference in decrease ( White-Up-Pointing-Small-Triangle Hb) were subjected to univariate and multivariable analysis to identify factors that predict disease-specific survival (DSS), local regional recurrence-free survival (LRFS), and metastases-free survival (MFS). Results: The 5-year DSS was poorer in the Hb continuous decrease group than in the Hb noncontinuous decrease group (84% vs. 89%; p = 0.008). There was poorer 5-year DSS in patients with White-Up-Pointing-Small-Triangle Hb of >11.5 g/L than in those with White-Up-Pointing-Small-Triangle Hb of {<=}11.5 g/L (82% vs. 89%; p = 0.001), and poorer LRFS (79% vs. 83%; p = 0.035). Univariate and multivariate analysis showed that Hb decrease difference with greater than 11.5 g/L was an independent prognostic factor for DSS and LRFS. Conclusions: The difference in decrease of Hb level during the course of radiation treatment appeared as a poor prognostic factor in Stage I and II nasopharyngeal carcinoma patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the nexus between atom probe microscopy and density functional theory simulations

The capability of precisely determining the atomic identity and position, coupled with an understanding of the inter-atomic interactions is crucial to enabling microstructure-property relationships in modern materials science. Two approaches to the investigation of materials at the atomic-scale are atom probe microscopy (APM) and density functional theory (DFT). On the one hand, APM offers an ultimate in 3D elemental analysis by determining the chemical identity and atomic position in a material. On the other, first principles DFT simulations allow the prediction of atomic structure and, critically, the electronic structure which is the gateway to calculating the real-world properties of materials. Both approaches are undertaken at the atomic-scale, and so are intrinsically complementary. This paper provides a review of the opportunities and challenges in combining these approaches to do materials science. We first summarise the status of these approaches and set out a framework for the current main workflows by which APM experiments inform DFT simulations and vice-versa. We point out certain gaps between the approaches and ways that these may be bridged via a series of case-studies organised into the aforementioned workflow framework.

36 MATERIALS SCIENCE↗

Revealing origin of quasi-one dimensional current transport in defect rich two dimensional materials

The presence of defects in graphene have for a long time been recognized as a bottleneck for its utilization in electronic and mechanical devices. We recently showed that micro four-point probes may be used to evaluate if a graphene film is truly 2D or if defects in proximity of the probe will lead to a non-uniform current flow characteristic of lower dimensionality. In this work, simulations based on a finite element method together with a Monte Carlo approach are used to establish the transition from 2D to quasi-1D current transport, when applying a micro four-point probe to measure on 2D conductors with an increasing amount of line-shaped defects. Clear 2D and 1D signatures are observed at low and high defect densities, respectively, and current density plots reveal the presence of current channels or branches in defect configurations yielding 1D current transport. A strong correlation is found between the density filling factor and the simulation yield, the fraction of cases with 1D transport and the mean sheet conductance. The upper transition limit is shown to agree with the percolation threshold for sticks. Finally, the conductance of a square sample evaluated with macroscopic edge contacts is compared to the micro four-point probe conductance measurements and we find that the micro four-point probe tends to measure a slightly higher conductance in samples containing defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Formation and evolution of small B clusters in Si: Ion channeling study

B off-lattice displacement in B-doped Si was observed under Si self-interstitials (Is) supersaturation induced by ion irradiation at room temperature. B lattice location has a characteristic channeling mark and was studied by nuclear reaction analyses and ion channeling technique, through the comparison of the performed angular scans along the <100> and <110> crystal axes and the simulated scans by FLUX code. Solid and liquid-phase epitaxies and molecular beam epitaxy were used to prepare B-doped Si samples in order to investigate samples with B concentration in the range between 10{sup 19} and 10{sup 21} at/cm{sup 3}. B off-lattice displacement is limited by the fluence of excess Is per B atom. Small B-Is clusters (BICs) were formed as consequence of the interaction with Is produced during the ion irradiation. Clusters structures were investigated by simulating the channeling angular scans of cluster configurations predicted by theoretical calculations. In the early stage of Is injection, experimental observations are consistent with the presence of the predicted B{sub 2}I clusters. These small BICs evolved into different structures under further ion irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Pressure Electrochemical Synthesis of Complex High-Pressure Superconducting Superhydrides

There is great current interest in multicomponent superhydrides due to their unique quantum properties under pressure. A remarkable example is the ternary superhydride Li 2 MgH 16 computationally identified to have an unprecedented high superconducting critical temperature T c of ~470 K at 250 GPa. However, the very high synthesis pressures required remains a significant hurdle for detailed study and potential applications. In this Letter, we evaluate the feasibility of synthesizing ternary Li-Mg superhydrides by the recently proposed pressure-potential (P 2 ) method that uniquely combines electrochemistry and applied pressure to control synthesis and stability. Furthermore, the results indicate that it is possible to synthesize Li-Mg superhydrides at modest pressures by applying suitable electrode potentials. Using pressure alone, no Li-Mg ternary hydrides are predicted to be thermodynamically stable, but in the presence of electrode potentials, both Li 2 MgH 16 and Li 4 MgH 24 can be stabilized at modest pressures. Three polymorphs are predicted as ground states of Li 2 MgH 16 below 300 GPa, with transitions at 33 and 160 GPa. The highest pressure phase is superconducting, while the two at lower pressures are not. Our findings point out the potentially important role of the P 2 method in controlling phase stability of complex multicomponent superhydrides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying and Reducing Curve-Fitting Uncertainty in Isc: Preprint

Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data points can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.

14 SOLAR ENERGY↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Embedded Active Fiber Optic Sensing Network for Structural Health Monitoring in Harsh Environments

This report summarizes technical progress on the program “Embedded Active Fiber Optic Sensing Network for Structural Health Monitoring in Harsh Environments” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology at Virginia Tech. The objective of this project is to develop a first-of-a-kind technology for remote fiber optic generation and detection of acoustic waves for structural health monitoring in harsh environments. During the project period, which is from April 1, 2013 to Septemeber 30, 2016, three different acoustic generation mechanisms were studied in detail for their applications in building a fiber optic acoustic generation unit (AGU), including laser induced plasma breakdown (LIP), Erbium-doped fiber laser absorption, and metal laser absorption. By comparing the performance of the AGUs designed based on these three mechanisms and analyzing the experimental results with simulations, the metal laser absorption method was selected to build a complete fiber optic structure health monitoring (FO-SHM) system for the proposed high temperature multi-parameter structure health monitoring application. Based on the simulation of elastic wave propagation and fiber Bragg grating acoustic pulse detection, an FO-SHM element together with a completed interrogation system were designed and built. This system was first tested on an aluminum piece in the low-temperature range and successfully demonstrated its capability of multi-parameter monitoring and multi-point sensing. In the later stages of the project, the research was focused on improving the surface attachment design and preparing the FO-SHM element for high temperature environment tests. After several upgrades to the surface attachment methods, the FO-SHM element was able to work reliably up to 600oC when attached to P91 pipes, which are the target material of this project. In the final stage of this project, this FO-SHM sensing system was tested in the simulated harsh environment for its multi-parameter monitoring performance and high-temperature survivability.

20 FOSSIL-FUELED POWER PLANTS↗

Systems and methods for processing irradiation targets through a nuclear reactor

Apparatuses and methods produce radioisotopes in instrumentation tubes of operating commercial nuclear reactors. Irradiation targets may be inserted and removed from instrumentation tubes during operation and converted to radioisotopes otherwise unavailable during operation of commercial nuclear reactors. Example apparatuses may continuously insert, remove, and store irradiation targets to be converted to useable radioisotopes or other desired materials at several different origin and termination points accessible outside an access barrier such as a containment building, drywell wall, or other access restriction preventing access to instrumentation tubes during operation of the nuclear plant.

07 ISOTOPE AND RADIATION SOURCES↗

Deep Borehole Disposal: Options, Issues and Challenges - 16250

Different versions of deep borehole disposal vary in approach and detail and the differences raise issues and create options that need to be considered in the design of any practical implementation. Among the areas for which significant options exist are the size and depth of the disposal zone; container materials and design; the method and strategy for waste package deployment; filling of the annuli around the waste packages and the final sealing of the borehole. The options for these and other areas are discussed with a focus on their advantages and disadvantages and some conclusions reached that could provide guidance for the practical application of the concept. One particularly significant point is that the integrity of the final borehole seal(s) may not be required to survive for as long as is widely believed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

36 MATERIALS SCIENCE↗