Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Airborne Carbon Dioxide Laser Absorption Spectrometer for IPDA Measurements of Tropospheric CO2: Recent Results

The National Research Council's decadal survey on Earth Science and Applications from Space[1] recommended the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission for launch in 2013-2016 as a logical follow-on to the Orbiting Carbon Observatory (OCO) which is scheduled for launch in late 2008 [2]. The use of a laser absorption measurement technique provides the required ability to make day and night measurements of CO2 over all latitudes and seasons. As a demonstrator for an approach to meeting the instrument needs for the ASCENDS mission we have developed the airborne Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) which uses the Integrated Path Differential Absorption (IPDA) Spectrometer [3] technique operating in the 2 micron wavelength region.. During 2006 a short engineering checkout flight of the CO2LAS was conducted and the results presented previously [4]. Several short flight campaigns were conducted during 2007 and we report results from these campaigns.

lidar↗

Remote gate capacitance-voltage studies for noninvasive surface characterization

A measurement technique has been developed which allows noncontact capacitance-voltage measurements to be made using a gate electrode located remote from the semiconductor surface under study. With gate electrodes about 0.5 mm in diameter and gate to semiconductor separations of about 1500 A, it was possible to generate data entirely comparable to that obtained with integrated MIS structures but with the advantage that there was access directly to the free-semiconductor surface. This technique was applied to bulk single-crystal Si and InP samples.

Chang, R. R.↗

Biophotonic in situ sensor for plant leaves

Knowledge of the water concentration of plants can be helpful in several environmental and agricultural domains. There are many methods for the determination of water content in plant leaves; however, most of them give a relative moisture level or an analytical measure after a previous calibration procedure. Even for other biochemical compounds such as dry matter or chlorophyll, the measurement techniques could be destructive. For this reason, a nondestructive method has been developed to measure the biochemical compounds of a plant leaf, using an infrared spectroscopy technique. One important advantage is the simplicity of the device (RAdiometre portatif de Mesure In Situ, RAMIS) and its capability to perform measurements in situ. The prototype is a leaf-clip configuration and is made of LEDs at five wavelengths (656, 721, 843, 937, and 1550 nm), and a silicon/germanium photosensor. To compute the water content of vegetative leaves, the radiative transfer model PROSPECT was implemented. This model can accurately predict spectral transmittances in the 400 nm to 2500 nm spectral region as a function of the principal leaf biochemical contents: water, dry matter, and chlorophyll. Using the transmittance measured by RAMIS into an inversion procedure of PROSPECT: A Model of Leaf Optical Properties Spectra, we are able to compute the values of water contents that show an agreement with the water contents measured directly using dry weight procedures. This method is presented as a possibility to estimate other leaf biochemical compounds using appropriate wavelengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of the Optical Connectivity Method to X-Ray spray measurements in the near field of a diesel injector

For diesel sprays, the primary breakup processes are only rarely understood due to the high optical density and the resulting difficulties to measure them with extremely high spatial and sufficient temporal resolution. The Optical Connectivity Method (OCM) has been proposed in the last years to allow the determination of the breakup length of the connected liquid core, thus giving a measurement quantity of the primary breakup. In this research, an improved optical setup of the OCM is applied to a three-hole test injector nozzle where several measurement techniques are compared currently under well-defined conditions up to 100 MPa injection pressure. In this work, the direct comparison with X-Ray measurements done at the Advanced Photon Source of the Argonne National Laboratory will be described. This allows an evaluation of the OCM technique and a comparison of the different measurement quantities in the first 500 μm range of the spray. The structure of the spray is measured by X-Ray phase contrast imaging and the fuel mass distribution is measured by X-Ray absorption imaging. A detailed comparison of the two X-Ray techniques and the OCM technique has been possible for the first time. It is found that the measurement data of the spray near field are very congruent with all three methods. Due to this comparison, the measurement of the non-perturbed length, which describes the distance from the nozzle orifice up to the point where the formation of surface disturbances is starting, by the OCM is validated for the first time. Within this non-perturbed length of the spray, the OCM signal is weak before it starts to illuminate from the scattering of the perturbed surface. Hence, the OCM technique can deliver two characteristic length scales, the non-perturbed length and the breakup length , characterizing the primary spray breakup.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal Property Characterization of Molten Salt Reactor–Relevant Salts

The thermochemical and thermophysical properties of molten salt systems are necessary input for the design, licensing, and deployment of molten salt reactor concepts. The thermochemical and thermophysical property measurement capabilities being used and developed at Oak Ridge National Laboratory (ORNL) include liquid density, volumetric thermal expansion, viscosity, vapor pressure, phase behavior, and heat capacity and thermal conductivity measurement capabilities. Properties of eutectic LiF-NaF-KF (FLiNaK) and NaCl-KCl are being measured to validate the measurement techniques to be used to provide data to reactor developers and to better quantify the uncertainty of measurements. This report summarizes the status of thermal conductivity, viscosity, specific heat capacity, and density. A method for property estimation using Redlich Kister expansion is also described. This technique will be used to help validate measured properties and to guide future experiments by targeting mixtures or components for which data are uncertain or lacking.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WellSTIC: A Cost-Effective Sensor for Performing Point Dilution Tests to Measure Groundwater Velocity in Shallow Aquifers

Many individual measurement points are required to characterize groundwater velocity within an aquifer. Groundwater velocity is most commonly measured using a network of >5 cm diameter monitoring wells, which, if not already present at a site, are expensive and labor-intensive to install. Drive-point piezometers—simple, cost-effective wells that can be installed by hand—are a common tool for sampling groundwater in shallow, alluvial aquifers, but most groundwater velocity measurement techniques require equipment that is too large for these narrow (usually <2 cm inside diameter) piezometers. In this technical note, we introduce a low-cost sensor and well packer system (<$90 USD) for performing point dilution tests in narrow piezometers. Field data show that the magnitude of groundwater velocity measured with this technique agrees with velocities computed from natural gradient tracer tests. Additionally, with proper calibration, these sensors can be used to continuously monitor in-well specific conductance, either during inter-well tracer tests with saline tracers or for water quality monitoring. Finally, this system is a viable tool for rapid assessment of the magnitude of groundwater velocity in shallow aquifers.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation and Loss Modeling of WBG Devices based on a Novel Double-Pulse Test Method for Current Source Inverter

Careful measurements of the power device characteristics are necessary to accurately estimate a power converter's losses and efficiency. The conventional double-pulse test (DPT) circuit is a well-known method to implement this laboratory characterization of power devices and power modules. However, the switching characteristics of a power device depend on the power electronics circuit in which it is connected as well as the power circuit's physical layout, in addition to the device's internal structure. Hence, the conventional DPT circuit configuration, which is tailored for a standard voltage-source inverter (VSI), is not well-suited for a current-source inverter (CSI). This paper demonstrates a previously-proposed CSI-based DPT measurement technique that is appropriate for normal CSI operation. The characteristics of SiC MOSFETs and series-connected SiC Schottky diodes used in a CSI are measured using this improved technique while taking temperature effects into account to yield more accurate loss predictions. The CSI losses, including the switching and conduction losses of SiC MOSFETs and SiC Schottky diodes, have been modeled using this approach. The total CSI losses and efficiency have been estimated based on the CSI DPT results and loss models.

42 ENGINEERING↗

Discriminating Uranium Isotopes Using the Time-Emission Profiles of Long-Lived Delayed Neutrons

In nuclear nonproliferation and safeguards, detecting and accurately characterizing special nuclear material remains one of the greatest challenges. Uranium enrichment determination is typically achieved by measuring the ratio of characteristic γ -ray emissions from 235 U and 238 U. Fission also produces β -delayed neutrons, which have been used in the past to determine uranium enrichment from the time dependence of the long-lived delayed-neutron emission rate. Such measurements typically use moderated 3 He-tube detectors. We demonstrate an alternative measurement technique that employs a fast neutron active-interrogation probe and a scintillation detector to measure the enrichment of uranium using both the buildup and decay of β -delayed-neutron emission. Instead of 3 He tubes, a capture-based heterogeneous composite detector consisting of scintillating Li glass and polyvinyl toluene is constructed and used, offering a prospect to scale delayed-neutron measurements to larger detector sizes. Since the technique relies on the existing tabulated nuclear data, no calibration standards are required. It is shown that the buildup of delayed-neutron emission can be used to distinguish between uranium samples and infer the uranium enrichment level, with accuracy that rivals the method that employs the time-dependent decay of delayed-neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗

Solvent residue content measured by light scattering technique

Photometric analyzer measures NVR /nonvolatile residue/ in trichloroethylene and other organic solvents. The analyzer converts the liquid solvent to aerosol and passes it between an optically focused light beam and a photodetector that is connected to standard amplifying and readout equipment.

Salkowski, M. J.↗

X-ray scattering measurements of dissociation-induced metallization of dynamically compressed deuterium

Hydrogen, the simplest element in the universe, has a surprisingly complex phase diagram. Because of applications to planetary science, inertial confinement fusion and fundamental physics, its high-pressure properties have been the subject of intense study over the past two decades. While sophisticated static experiments have probed hydrogen’s structure at ever higher pressures, studies examining the higher-temperature regime using dynamic compression have mostly been limited to optical measurement techniques. Here we present spectrally resolved x-ray scattering measurements from plasmons in dynamically compressed deuterium. Combined with Compton scattering, and velocity interferometry to determine shock pressure and mass density, this allows us to extract ionization state as a function of compression. Finally, the onset of ionization occurs close in pressure to where density functional theory-molecular dynamics (DFT-MD) simulations show molecular dissociation, suggesting hydrogen transitions from a molecular and insulating fluid to a conducting state without passing through an intermediate atomic phase.

36 MATERIALS SCIENCE↗

Influence of environmental thoron on radon measurements and related issues

Recently importance of thoron measurements has also been recognized from the viewpoint of accurate radon measurements. The present study covers specification of the NIRS thoron chamber, passive measurement technique of radon and thoron and thoron interference on radon measurements from both experimental studies and field experiences on epidemiological study area.

54 ENVIRONMENTAL SCIENCES↗

Characterization of interface states in Al{sub 2}O{sub 3}/AlGaN/GaN structures for improved performance of high-electron-mobility transistors

We have investigated the relationship between improved electrical properties of Al{sub 2}O{sub 3}/AlGaN/GaN metal-oxide-semiconductor high-electron-mobility transistors (MOS-HEMTs) and electronic state densities at the Al{sub 2}O{sub 3}/AlGaN interface evaluated from the same structures as the MOS-HEMTs. To evaluate Al{sub 2}O{sub 3}/AlGaN interface state densities of the MOS-HEMTs, two types of capacitance-voltage (C-V) measurement techniques were employed: the photo-assisted C-V measurement for the near-midgap states and the frequency dependent C-V characteristics for the states near the conduction-band edge. To reduce the interface states, an N{sub 2}O-radical treatment was applied to the AlGaN surface just prior to the deposition of the Al{sub 2}O{sub 3} insulator. As compared to the sample without the treatment, the N{sub 2}O-radical treated Al{sub 2}O{sub 3}/AlGaN/GaN structure showed smaller frequency dispersion of the C-V curves in the positive gate bias range. The state densities at the Al{sub 2}O{sub 3}/AlGaN interface were estimated to be 1 × 10{sup 12} cm{sup −2} eV{sup −1} or less around the midgap and 8 × 10{sup 12} cm{sup −2} eV{sup −1} near the conduction-band edge. In addition, we observed higher maximum drain current at the positive gate bias and suppressed threshold voltage instability under the negative gate bias stress even at 150 °C. Results presented in this paper indicated that the N{sub 2}O-radical treatment is effective both in reducing the interface states and improving the electrical properties of the Al{sub 2}O{sub 3}/AlGaN/GaN MOS-HEMTs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric characterization of round HDR {sup 192}Ir AccuBoost applicators for breast brachytherapy

Purpose: The AccuBoost brachytherapy system applies HDR {sup 192}Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR {sup 192}Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. Methods: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. Results: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. Conclusions: Monte Carlo benchmarking simulations of the HDR {sup 192}Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗