Search NASA⌕ Search

SEARCH · Search NASA

Results for “Membrane Potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Separation of CO2 from flue gas using electrochemical cells

Past research with high temperature molten carbonate electrochemical cells has shown that carbon dioxide can be separated from flue gas streams produced by pulverized coal combustion for power generation. However, the presence of trace contaminants, i.e., sulfur dioxide and nitric oxides, will impact the electrolyte within the cell. If a lower temperature cell could be devised that would utilize the benefits of commercially-available, upstream desulfurization and denitrification in the power plant, then this CO2 separation technique can approach more viability in the carbon sequestration area. Recent work has led to the assembly and successful operation of a low temperature electrochemical cell. In the proof-of-concept testing with this cell, an anion exchange membrane was sandwiched between gas-diffusion electrodes consisting of nickel-based anode electrocatalysts on carbon paper. When a potential was applied across the cell and a mixture of oxygen and carbon dioxide was flowed over the wetted electrolyte on the cathode side, a stream of CO2 to O2 was produced on the anode side, suggesting that carbonate/ bicarbonate ions are the CO2 carrier in the membrane. Since a mixture of CO2 and O2 is produced, the possibility exists to use this stream in oxy-firing of additional fuel. From this research, a novel concept for efficiently producing a carbon dioxide rich effluent from combustion of a fossil fuel was proposed. Carbon dioxide and oxygen are captured from the flue gas of a fossilfuel combustor by one or more electrochemical cells or cell stacks. The separated stream is then transferred to an oxy-fired combustor which uses the gas stream for ancillary combustion, ultimately resulting in an effluent rich in carbon dioxide. A portion of the resulting flow produced by the oxy-fired combustor may be continuously recycled back into the oxy-fired combustor for temperature control and an optimal carbon dioxide rich effluent

Keywords: Carbon dioxide sequestration Carbon capt↗

Extracellular Polymeric Substances from Shewanella sp. HRCR-1 Biofilms: Characterization by Infrared Spectroscopy and Proteomics

This study characterizes the composition of extracellular polymeric substances (EPS) from Shewanella sp. HRCR-1 biofilms to provide insight into potential interactions of EPS with redox-active metals and radionuclides. Both bound and loosely associated EPS were extracted from Shewanella sp. HRCR-1 biofilms prepared using a hollow-fiber membrane biofilm reactor (HfMBR). FTIR spectra revealed the presence of proteins, polysaccharides, nucleic acids, membrane lipids, and fatty acids in both bound and loosely associated EPS. Using a global proteomic approach, a total of 58 extracellular and outer membrane proteins were identified in the EPS. These included homologues of multiple S. oneidensis MR-1 proteins that potentially contribute to key physiological biofilm processes, such as biofilm-promoting protein BpfA, surface-associated serine protease, nucleotidases (CpdB and UshA), an extracellular lipase, and oligopeptidases (PtrB and a M13 family oligopeptidase lipoprotein). In addition, 20 redox proteins were found in extracted EPS. Among the detected redox proteins were the homologues of two S. oneidensis MR-1 c-type cytochromes, MtrC and OmcA, which have been implicated in extracellular electron transfer. Given their detection in the EPS of Shewanella sp. HRCR 1 biofilms, c-type cytochromes may contribute to the possible redox activity of the biofilm matrix and play important roles in extracellular electron transfer reactions.

59 BASIC BIOLOGICAL SCIENCES↗

Nitrided Metallic Bipolar Plates

The objectives are: (1) Develop and optimize stainless steel alloys amenable to formation of a protective Cr-nitride surface by gas nitridation, at a sufficiently low cost to meet DOE targets and with sufficient ductility to permit manufacture by stamping. (2) Demonstrate capability of nitridation to yield high-quality stainless steel bipolar plates from thin stamped alloy foils (no significant stamped foil warping or embrittlement). (3) Demonstrate single-cell fuel cell performance of stamped and nitrided alloy foils equivalent to that of machined graphite plates of the same flow-field design ({approx}750-1,000 h, cyclic conditions, to include quantification of metal ion contamination of the membrane electrode assembly [MEA] and contact resistance increase attributable to the bipolar plates). (4) Demonstrate potential for adoption in automotive fuel cell stacks. Thin stamped metallic bipolar plates offer the potential for (1) significantly lower cost than currently-used machined graphite bipolar plates, (2) reduced weight/volume, and (3) better performance and amenability to high volume manufacture than developmental polymer/carbon fiber and graphite composite bipolar plates. However, most metals exhibit inadequate corrosion resistance in proton exchange membrane fuel cell (PEMFC) environments. This behavior leads to high electrical resistance due to the formation of surface oxides and/or contamination of the MEA by metallic ions, both of which can significantly degrade fuel cell performance. Metal nitrides offer electrical conductivities up to an order of magnitude greater than that of graphite and are highly corrosion resistant. Unfortunately, most conventional coating methods (for metal nitrides) are too expensive for PEMFC stack commercialization or tend to leave pinhole defects, which result in accelerated local corrosion and unacceptable performance.

30 DIRECT ENERGY CONVERSION↗

Bipolar membrane polarization behavior with systematically varied interfacial areas in the junction region

The palette of applications for bipolar membranes (BPMs) has expanded recently beyond electrodialysis as they are now being considered for fuel cell and electrolysis applications. Their deployment in emerging electrochemical technologies arises from the need to have a membrane separator that provides disparate pH environments and to prevent species crossover. Most materials research for BPMs has focused on water dissociation catalysts and less emphasis has been given to the design of the polycation–polyanion interface for improving BPM performance. Here, soft lithography fabricated a series of micropatterned BPMs with precise control over the interfacial area in the bipolar junction. Polarization experiments showed that a 2.28× increase in interfacial area led to a 250 mV reduction in the onset potential. Additionally, the same increase in interfacial area yielded marginal improvements in current density due to the junction region being under kinetics-diffusion control. A simple physics model based on the electric field of the junction region rationalized the reduction in the overpotential for water dissociation as a function of interfacial area. Finally, the soft lithography approach was also conducive for fabricating BPMs with different chemistries ranging from perfluorinated polymer backbones to alkaline stable poly(arylene) hydrocarbon polymers. These polymer chemistries are better suited for fuel cell and electrolysis applications. The BPM featuring the alkaline stable poly(terphenyl) anion exchange membrane had an onset potential of 0.84 V, which was near the thermodynamic limit, and was about 150 mV lower than a commercially available variant.

25 ENERGY STORAGE↗

Communication: Nanoscale ion fluctuations in Nafion polymer electrolyte

Ion conduction mechanisms and the nanostructure of ion conduction networks remain poorly understood in polymer electrolytes which are used as proton-exchange-membranes (PEM) in fuel cell applications. Here we study nanoscale surface-potential fluctuations produced by Brownian ion dynamics in thin films of low-hydration Nafion™, the prototype PEM. Images and power spectra of the fluctuations are used to derive the local conductivity-relaxation spectrum, in order to compare with bulk behavior and hopping-conductivity models. Conductivity relaxation-times ranged from hours to milliseconds, depending on hydration and temperature, demonstrating that the observed fluctuations are produced by water-facilitated hydrogen-ion hopping within the ion-channel network. Due to the small number of ions probed, non-Gaussian statistics of the fluctuations can be used to constrain ion conduction parameters and mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diel Transcriptional Oscillations of a Plastid Antiporter Reflect Increased Resilience of Thalassiosira pseudonana in Elevated CO 2

Acidification of the ocean due to high atmospheric CO 2 levels may increase the resilience of diatoms causing dramatic shifts in abiotic and biotic cycles with lasting implications on marine ecosystems. Here, we report a potential bioindicator of a shift in the resilience of a coastal and centric model diatom Thalassiosira pseudonana under elevated CO 2 . Specifically, we have discovered, through EGFP-tagging, a plastid membrane localized putative Na + (K + )/H + antiporter that is significantly upregulated at >800 ppm CO 2 , with a potentially important role in maintaining pH homeostasis. Notably, transcript abundance of this antiporter gene was relatively low and constant over the diel cycle under contemporary CO 2 conditions. In future acidified oceanic conditions, dramatic oscillation with >10-fold change between nighttime (high) and daytime (low) transcript abundances of the antiporter was associated with increased resilience of T. pseudonana. By analyzing metatranscriptomic data from the Tara Oceans project, we demonstrate that phylogenetically diverse diatoms express homologs of this antiporter across the globe. We propose that the differential between night- and daytime transcript levels of the antiporter could serve as a bioindicator of a shift in the resilience of diatoms in response to high CO 2 conditions in marine environments.

59 BASIC BIOLOGICAL SCIENCES↗

A combined experimental and computational study of the molecular interactions between anionic ibuprofen and water

In this work, we report a detailed study of the microsolvation of anionic ibuprofen, Ibu{sup −}. Stochastic explorations of the configurational spaces for the interactions of Ibu{sup −} with up to three water molecules at the DFT level lead to very rich and complex potential energy surfaces. Our results suggest that instead of only one preponderant structure, a collection of isomers with very similar energies would have significant contributions to the properties of the solvated drug. One of these properties is the shift on the vibrational frequencies of the asymmetric stretching band of the carboxylate group in hydrated Ibu{sup −} with respect to the anhydrous drug, whose experimental values are nicely reproduced using the weighted contribution of the structures. We found at least three types of stabilizing interactions, including conventional CO {sub 2}{sup −}⋯H{sub 2}O, H{sub 2}O⋯H{sub 2}O charge assisted hydrogen bonds (HBs), and less common H{sub 2}O⋯H–C and H{sub 2}O⋯π interactions. Biological water molecules, those in direct contact with Ibu{sup −}, prefer to cluster around the carboxylate oxygen atoms via cyclic or bridged charge assisted hydrogen bonds. Many of those interactions are strongly affected by the formal carboxylate charge, resulting in “enhanced” HBs with increased strengths and degree of covalency. We found striking similarities between this case and the microsolvation of dymethylphosphate, which lead us to hypothesize that since microsolvation of phosphatidylcholine depends mainly on the formal charge of its ionic PO {sub 2}{sup −} group in the polar head, then microsolvation of anionic ibuprofen and interactions of water molecules with eukaryotic cell membranes are governed by the same types of physical interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Commercialization of a Nanosegrated Oxygen Evolution Reaction Electrocatalyst (CRADA)

This collaborative project leverages advanced characterization tools, catalyst treatment and electrochemical testing capabilities at LBNL to help commercialize a bimetallic nanosegrated catalysts for oxygen evolution reaction in proton-exchange membrane water electrolyzers. This project also has three industrial partners who are involved in catalyst scale-up synthesis, large electrode fabrication and large electrode electrochemical testing. This project investigates a broad range of topics including electrocatalysis, ink rheology and electrode fabrication and testing. This knowledge could help bridge the performance and durability gap from laboratory-developed materials (such as electrocatalysts) to applications in commercial devices. The research results also bring fundamental understanding of possible degradation mechanisms that occur under extremely oxidative potentials including material and morphological changes. The project will help accelerate the deployment of proton-exchange membrane water electrolyzers. The public benefits could include creating jobs and increasing public awareness of potential clean technologies for green hydrogen production. Ultimately, the project will help national wide effort of flighting climate change and achieving carbon neutrality by 2050.

30 DIRECT ENERGY CONVERSION↗

Synthesis of polymer electrolyte membranes from cellulose acetate/poly(ethylene oxide)/LiClO{sub 4} for lithium ion battery application

This study was conducted to determine the effect of cellulose acetate on poly(ethylene oxide)-LiClO{sub 4} membranes as the polymer electrolyte. Cellulose acetate is used as an additive to increase ionic conductivity and mechanical property of polymer electrolyte membranes. The increase the percentage of cellulose acetate in membranes do not directly effect on the ionic conductivity, and the highest ionic conductivity of membranes about 5,7 × 10{sup −4} S/cm was observed in SA/PEO/LiClO{sub 4} membrane with cellulose ratio of 10-25% (w/w). Cellulose acetate in membranes increases mechanical strength of polymer electrolyte membranes. Based on TGA analysis, this polymer electrolyte thermally is stable until 270 °C. The polymer electrolyte membrane prepared by blending the cellulose acetate, poly(ethylene oxide), and lithium chlorate could be potentially used as a polymer electrolyte for lithium ion battery application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-regulation of signaling pathways: An example of nuclear hormone receptors and the canonical Wnt pathway

Predicting the potential physiological outcome(s) of any given molecular pathway is complex because of cross-talk with other pathways. This is particularly evident in the case of the nuclear hormone receptor and canonical Wnt pathways, which regulate cell growth and proliferation, differentiation, apoptosis, and metastatic potential in numerous tissues. These pathways are known to intersect at many levels: in the intracellular space, at the membrane, in the cytoplasm, and within the nucleus. The outcomes of these interactions are important in the control of stem cell differentiation and maintenance, feedback loops, and regulating oncogenic potential. The aim of this review is to demonstrate the importance of considering pathway cross-talk when predicting functional outcomes of signaling, using nuclear hormone receptor/canonical Wnt pathway cross-talk as an example.

60 APPLIED LIFE SCIENCES↗

Membrane Process to Capture CO 2 from Coal-Fired Power Plant Flue Gas

This final report describes work conducted for the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL) on development of an efficient membrane process to capture carbon dioxide (CO 2 ) from power plant flue gas (award number DE-NT0005312). The primary goal of this research program was to demonstrate, in a field test, the ability of a membrane process to capture up to 90% of CO 2 in coal-fired flue gas, and to evaluate the potential of a full-scale version of the process to perform this separation with less than a 35% increase in the levelized cost of electricity (LCOE). Membrane Technology and Research (MTR) conducted this project in collaboration with Arizona Public Services (APS), who hosted a membrane field test at their Cholla coal-fired power plant, and the Electric Power Research Institute (EPRI) and WorleyParsons (WP), who performed a comparative cost analysis of the proposed membrane CO 2 capture process.

20 FOSSIL-FUELED POWER PLANTS↗

Single-Layer Graphene Sandwiched between Proton-Exchange Membranes for Selective Proton Transmission

Proton transmission through single-layer CVD graphene in graphene/proton-exchange-membrane (PEM) sandwich structures is found to be more than 100 times faster than for any other cation. Ion transmission rates were measured for protons and a series of other cations including Li + , Na + , K + , Rb + , Cs + , and NH 4 + using a four-electrode method in which two platinum electrodes drive ionic current through the membrane and two reference electrodes installed in Luggin capillaries sense the transmembrane potential difference induced by the forced ion flow. Characterization studies including confocal Raman microscopy and X-ray photoelectron spectroscopy for graphene on Nafion, and defect visualization by etching through defects for graphene on copper, are also reported. All findings are consistent with a defect-based mechanism for transmission through graphene of all cations except protons, which likely follow a different mechanism, perhaps involving high-rate transmission through sites at which transmission of other ions is forbidden. Electrochemical impedance spectroscopy (EIS) was also used to study ion transmission rates through graphene in PEM sandwich structures. EIS gave much lower resistances for ion transmission through graphene than were obtained using the four-electrode method. Here, this latter finding is thought to reflect a capacitive coupling of mobile ions with/through graphene at the high frequencies (up to 100 kHz) used in the EIS measurement. Near-steady-state dc methods are thus necessary to evaluate true ion transmission rates through graphene.

Ion transmission↗

Effect of porous transport layer properties on the anode electrode in anion exchange membrane electrolyzers

Anion exchange membrane water electrolyzers (AEMELs) have recently received significant attention due to their potential advantages over existing commercial water electrolysis technologies. However, AEM electrolyzers have not yet met performance and durability targets. One of the critical components in achieving high AEMEL performance is the porous transport layer (PTL) which serves many critical functions in the oxygen evolution reaction (OER) electrode. In this study, several OER PTL attributes were investigated, including: material of construction, fabrication method, feature size, porosity/density, and thickness. It was found that higher porosity helped facilitate multiphase (O 2 , H 2 O, etc.) transport; however, as the porosity increased, the catalyst layer adhesion to the PTL decreased, the contact resistance with the bipolar plate increased and the cell operating voltage increased. It was found that nickel-based PTLs allowed for lower operating voltages than similarly-structured stainless steel PTLs. Improved operating voltages were achieved with both fiber felts and sintered structures by porosity optimization. Furthermore, an increase in thickness did not affect transient voltage response, however, it had a negative effect on performance stability. As a result, the experimental findings presented here provide important insights for development of PTL materials and structures for efficient and low-cost water electrolysis.

08 HYDROGEN↗

Computing Potential of the Mean Force Profiles for Ion Permeation Through Channelrhodopsin Chimera, C1C2

Umbrella sampling, coupled with a weighted histogram analysis method (US-WHAM), can be used to construct potentials of mean force (PMFs) for studying the complex ion permeation pathways of membrane transport proteins. Despite the widespread use of US-WHAM, obtaining a physically meaningful PMF can be challenging. Here, we provide a protocol to resolve that issue. Then, we apply that protocol to compute a meaningful PMF for sodium ion permeation through channelrhodopsin chimera, C1C2, for illustration.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient Nanoporous Silicon Membranes for Integrated Microfluidic Separation and Sensing Systems

Nanoporous devices constitute emerging platforms for selective molecule separation and sensing, with great potential for high throughput and economy in manufacturing and operation. Acting as mass transfer diodes similar to a solid-state device based on electron conduction, conical pores are shown to have superior performance characteristics compared to traditional cylindrical pores. Such phenomena, however, remain to be exploited for molecular separation. Here we present performance results from silicon membranes created by a new synthesis technique based on interferometric lithography. This method creates millimeter sized planar arrays of uniformly tapered nanopores in silicon with pore diameter 100 nm or smaller, ideally-suited for integration into a multi-scale microfluidic processing system. Molecular transport properties of these devices are compared against state-of-the-art polycarbonate track etched (PCTE) membranes. Mass transfer rates of up to fifteen-fold greater than commercial sieve technology are obtained. Complementary results from molecular dynamics simulations on molecular transport are reported.

36 MATERIALS SCIENCE↗

Long-term stability of nanostructured thin film electrodes at operating potentials

Long-term stability of nanostructured thin film (NSTF) catalysts at operating potentials has been investigated. Compared to high surface area Pt/C catalysts, NSTF electrodes show 20–50x smaller F – emission rates (FER) because of their high specific activity for oxygen reduction reaction (ORR), but are susceptible to poisoning by the products of membrane degradation because of their low electrochemically active surface area (ECSA). The observed voltage degradation rates at potentials corresponding to 1–1.5 A/cm 2 current density are much higher than the allowable 13–14 μV/h. Although F – is not itself responsible for performance decay, cumulative fluoride release (CFR) is a good marker for catalyst surface contamination. The observed performance decay is not only due to loss of active Pt sites but also adsorbed impurities impeding ORR kinetics. There is a strong correlation between measured CFR and observed decrease in specific ORR activity and limiting current density and increase in mass transfer overpotentials. Furthermore, the correlations indicate that the target of <10% lifetime performance degradation can be achieved by restricting CFR in NSTF electrodes to 0.7 μg/cm 2 , as may be possible with more stable membranes, higher surface area NSTF catalysts, and cell operation at lower temperatures and higher relative humidities.

36 MATERIALS SCIENCE↗

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

Gazda, Daniel B.↗