Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Probing electronic transport of individual nanostructures with atomic precision

Accessing individual nanostructures with atomic precision is an important process in the bottom-up fabrication and characterization of electronic nanodevices. Local electrical contacts, namely nanoelectrodes, are often fabricated by using top-down lithography and chemical etching techniques. These processes however lack atomic precision and introduce the possibility of contamination. Here, we review recent reports on the application of a field-induced emission process in the fabrication of local contacts onto individual nanowires and nanotubes with atomic spatial precision. In this method, gold nanoislands are deposited onto nanostructures precisely by using a scanning tunneling microscope tip, which provides a clean and controllable process to ensure both electrically conductive and mechanically reliable contacts. The applicability of the technique has been demonstrated in a wide variety of nanostructures, including silicide atomic wires, carbon nanotubes, and copper nanowires. These local contacts bridge the nanostructures and the transport probes, allowing for the measurements of both electrical transport and scanning tunneling microscopy on the same nanostructures in situ. The direct correlation between electronic and transport properties and atomic structures can be explored on individual nanostructures at the unprecedented atomic level.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

In Situ Heater Design for Nanoscale Synchrotron-Based Full-Field Transmission X-Ray Microscopy

Abstract The oxidation of nickel powder under a controlled gas and temperature environment was studied using synchrotron-based full-field transmission X-ray microscopy. The use of this technique allowed for the reaction to be imaged in situ at 55 nm resolution. The setup was designed to fit in the limited working distance of the microscope and to provide the gas and temperature environments analogous to solid oxide fuel cell operating conditions. Chemical conversion from nickel to nickel oxide was confirmed using X-ray absorption near-edge structure. Using an unreacted core model, the reaction rate as a function of temperature and activation energy were calculated. This method can be applied to study many other chemical reactions requiring similar environmental conditions.

in situ↗

Shape- and Orientation-Dependent Scattering of Isolated Gold Nanostructures Using Polarized Dark-Field Microscopy

In this work, we demonstrate a simple and robust method for measuring the shape- and orientation-dependent optical scattering of various plasmonic nanostructures adsorbed onto a solid surface using polarized dark-field microscopy. By analyzing the dark-field scattering images of gold nanostructures using grazing incidence polarized light with a bench-top microscope, we are able to correlate optical scattering from the individual nanostructures with their shape and orientation. Depending on the size, shape, and orientation of the plasmonic nanostructures, they exhibit characteristic angle- and polarization-dependent scattering signals. Extracting the red, green, and blue channels of the scattering signals from a color-imaging detector as a function of azimuthal angle provides a polar plot of color intensity values that is characteristic of the underlying nanostructure. Examples are presented for various nanostructures, including spherical nanoparticles, nanotriangles, and nanorods. Experimental results are complemented by numerical calculations of the scattering spectra of representative model nanostructures. We demonstrate that the polarization- and orientation-dependent scattering behavior is a consequence of various localized surface plasmon modes existing in the nanostructures and can be used to verify the shape of individual objects as well as quickly identify the orientation of numerous objects on a densely populated substrate. We anticipate that this method will provide a rapid and efficient complement to the typical structural analysis of nanoparticles that is achieved by electron microscopy as well as providing a simple method for generating detailed information of the optical scattering of various types of individual plasmonic nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic‐Scale Surface Imaging of Bulk Epitaxial CsPbBr 3 Perovskite Single Crystals on Mica Using Light Assisted Scanning Tunneling Microscopy at Low‐Temperature (80 K)

Epitaxial single-crystalline CsPbBr 3 perovskite films on mica, prepared ex situ, are explored using a low-temperature scanning tunneling microscope (STM) by probing the unoccupied electronic states of their surface in ultra-high vacuum (UHV) at 80 K. Light-assisted STM measurements under a broadband illumination with visible light were employed to enhance and stabilize surface conductivity. STM imaging across the surface of macroscopic bulk CsPbBr 3 films reveals large flat terraces characterized by a specific type of surface reconstruction, consisting of parallel rows of U-shaped atomic nanostructures. These structures are spaced by 12 Å and exhibit an internal feature size of 5.1 Å. Density functional theory (DFT) calculations reproduce the experimental observations and reveal a competition between different orthorhombic CsPbBr 3 (110) surface reconstructions: a Cs-rich structure, identified as the most energetically stable, and three alternative Pb–Br-rich reconstructions, which are slightly higher in energy yet remain consistent with the STM data. Additional analyses that explicitly account for the mica substrate exclude the cubic CsPbBr 3 phase and other orthorhombic surface orientations, while showing that variations in the mica surface termination do not alter the preferred CsPbBr 3 (110) reconstruction. In conclusion, this combined approach thereby confirms our assignment and resolves previous STM interpretations of CsPbBr 3 .

36 MATERIALS SCIENCE↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Study of the growth and switching kinetics on ferroelectric nanocrystals of copolymer vinylidene fluoride and trifluoroethylene on an atomic force microscope

The growth of nanocrystals obtained from Langmuir-Blodgett films of ferroelectric copolymer consisting of 70% vinylidene fluoride and 30% trifluoroethylene has been investigated by atomic force microscopy (AFM). The radius and concentration of nanocrystals are found to depend on the annealing time of the film. A model for nanocrystal growth is proposed which yields adequate time dependences for nanocrystal size parameters. The switching kinetics of individual ferroelectric nanocrystals with an average diameter of 100-200 nm and a height of 15-20 nm has been investigated in the piezoelectric response mode. It is shown that the switching of nanocrystals has an activation character.

36 MATERIALS SCIENCE↗

2D IR Microscopy—Technology for Visualizing Chemical Dynamics in Heterogeneous Environments (Final Technical Report)

The primary focus of this project was the design, prototype, and demonstration of a 2D IR microscope. The start date of this project was July 15, 2016 and the project end date was July 14, 2022. In the early years of this project our team designed, prototyped, and completely integrated a homebuilt microscope head with our high-repetition rate 2D IR spectrometer. Once in place our research team focused on characterizing the 2D IR microscope and using it to investigate model systems relevant to energy technologies. As part of this process, we identified two initial chemical systems to use to further develop 2D IR imaging modalities. The first chemical system developed was a room temperature ionic liquid (RTIL) electrolyte system and the second chemical system was a mixture of carbonates and salts developed as a battery electrolyte system. The completion of this project resulted in the full characterization of chemical dynamics in a bulk RTIL system and the demonstration of 2D IR imaging across the RTIL cast as a microdroplet in silicon oil. In addition, we explored the liquid structures and dynamics of organic carbonate mixtures from the vantage point of the vibrational probe, methyl thiocyanate. By the end of the project, we had moved toward in-depth studies of the organic carbonate mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin of graphitic filaments on improving the electron field emission properties of negative bias-enhanced grown ultrananocrystalline diamond films in CH{sub 4}/Ar plasma

Microstructural evolution of bias-enhanced grown (BEG) ultrananocrystalline diamond (UNCD) films has been investigated using microwave plasma enhanced chemical vapor deposition in gas mixtures of CH{sub 4} and Ar under different negative bias voltages ranging from −50 to −200 V. Scanning electron microscopy and Raman spectroscopy were used to characterize the morphology, growth rate, and chemical bonding of the synthesized films. Transmission electron microscopic investigation reveals that the application of bias voltage induced the formation of the nanographitic filaments in the grain boundaries of the films, in addition to the reduction of the size of diamond grains to ultra-nanosized granular structured grains. For BEG-UNCD films under −200 V, the electron field emission (EFE) process can be turned on at a field as small as 4.08 V/μm, attaining a EFE current density as large as 3.19 mA/cm{sup 2} at an applied field of 8.64 V/μm. But the films grown without bias (0 V) have mostly amorphous carbon phases in the grain boundaries, possessing poorer EFE than those of the films grown using bias. Consequently, the induction of nanographitic filaments in grain boundaries of UNCD films grown in CH{sub 4}/Ar plasma due to large applied bias voltage of −200 V is the prime factor, which possibly forms interconnected paths for facilitating the transport of electrons that markedly enhance the EFE properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

How non-ohmic contact-layer diodes in perovskite pinholes affect abrupt low-voltage reverse-bias breakdown and destruction of solar cells

Perovskite solar cells (PSCs) rapidly degrade under reverse bias, a condition that may occur during partial shading. Here, in this study, we use electrical measurements, electron microscopy, and optical and thermal imaging to investigate abrupt breakdown and hotspotting under low reverse potentials (<|-2| V). We show that microscopic pinholes in the perovskite layer cause rapid, destructive breakdown under reverse bias despite minimally reducing power conversion efficiencies. Measurements on miniature (200-micrometer diameter) PSCs and perovskite-free transport-layer diodes indicate that abrupt, low-voltage breakdown occurs in nanoscale to micrometer-scale defects and that metal migration and filamentation are unlikely causes. Reverse-bias stability substantially improves when pinholes in the perovskite and transport layers are eliminated. Atomic layer deposition of tin oxide prevents abrupt breakdown by ensuring physical separation between electrodes-not by blocking metal ion migration. Perovskite researchers should adopt cleaner, more uniform deposition techniques to enable robust PSCs for further research and commercial applications.

14 SOLAR ENERGY↗

Automatic projection image registration for nanoscale X-ray tomographic reconstruction

Novel developments in X-ray sources, optics and detectors have significantly advanced the capability of X-ray microscopy at the nanoscale. Depending on the imaging modality and the photon energy, state-of-the-art X-ray microscopes are routinely operated at a spatial resolution of tens of nanometres for hard X-rays or ~ 10 nm for soft X-rays. The improvement in spatial resolution, however, has led to challenges in the tomographic reconstruction due to the fact that the imperfections of the mechanical system become clearly detectable in the projection images.Without proper registration of the projection images, a severe point spread function will be introduced into the tomographic reconstructions, causing the reduction of the three-dimensional (3D) spatial resolution as well as the enhancement of image artifacts. In this work, the development of a method that iteratively performs registration of the experimentally measured projection images to those that are numerically calculated by reprojecting the 3D matrix in the corresponding viewing angles is shown. Multiple algorithms are implemented to conduct the registration, which corrects the translational and/ or the rotational errors. A sequence that offers a superior performance is presented and discussed. Going beyond the visual assessment of the reconstruction results, the morphological quantification of a battery electrode particle that has gone through substantial cycling is investigated. The results show that the presented method has led to a better quality tomographic reconstruction, which, subsequently, promotes the fidelity in the quantification of the sample morphology.

42 ENGINEERING↗

Imaging Liquids Using Microfluidic Cells

Chemistry occurring in the liquid and liquid surface is important in many applications. Chemical imaging of liquids using vacuum based analytical techniques is challenging due to the difficulty in working with liquids with high volatility. Recent development in microfluidics enabled and increased our capabilities to study liquid in situ using surface sensitive techniques such as electron microscopy and spectroscopy. Due to its small size, low cost, and flexibility in design, liquid cells based on microfluidics have been increasingly used in studying and imaging complex phenomena involving liquids. This paper presents a review of microfluidic cells that were developed to adapt to electron microscopes and various spectrometers for in situ chemical analysis and imaging of liquids. The following topics will be covered including cell designs, fabrication techniques, unique technical features for vacuum compatible cells, and imaging with electron microscopy and spectroscopy. Challenges are summarized and recommendations for future development priority are proposed.

Environmental Molecular Sciences Laboratory↗

Direct imaging of both ferroelectric and antiferromagnetic domains in multiferroic BiFeO{sub 3} single crystal using x-ray photoemission electron microscopy

In this work, we propose to study the magnetic and ferroelectric configurations in ferroelectric multidomain BiFeO{sub 3} single crystals. Using x-ray (magnetic) linear dichroism in a photoemission electron microscope (X-PEEM), we are able to directly image both the antiferromagnetic and ferroelectric domains. We find that inside one single ferroelectric domain several antiferromagnetic domains coexist. This is different from what was observed on epitaxial thin films, where the ferroelectric domains perfectly match the antiferromagnetic ones, but also from previous neutron measurements on ferroelectric monodomain single-crystals for which one single antiferromagnetic domain was identified. This underlines the fundamental differences between thin films, bulk samples, and single versus ferroelectric multidomain samples.

36 MATERIALS SCIENCE↗

Correlating activities and defects in (photo)electrocatalysts using in-situ multi-modal microscopic imaging

Photo(electro)catalysts use sunlight to drive chemical reactions such as water splitting. A major factor limiting photocatalyst development is physicochemical heterogeneity which leads to spatially dependent reactivity. To link structure and function in such systems, simultaneous probing of the electrochemical environment at microscopic length scales and a broad range of timescales (ns to s) is required. Here, we address this challenge by developing and applying in- situ (optical) microscopies to map and correlate local electrochemical activity, with hole lifetimes, oxygen vacancy concentrations and photoelectrode crystal structure. Using this multi-modal approach, we study prototypical hematite (α-Fe 2 O 3 ) photoelectrodes. We demonstrate that regions of α-Fe 2 O 3 , adjacent to microstructural cracks have a better photoelectrochemical response and reduced back electron recombination due to an optimal oxygen vacancy concentration, with the film thickness and extended light exposure also influencing local activity. Our work highlights the importance of microscopic mapping to understand activity, in even seemingly homogeneous photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy

Liquid cell transmission electron microscopy allows for imaging of samples in a fully hydrated state at high resolution and has the potential for visualizing static or dynamic biological structures. However, the ionizing nature of the electron beam makes it difficult to discern real physiological dynamics from radiation induced artifacts within liquid cell samples. Electron flux thresholds for achieving high resolution structures from biological samples frozen in ice have been described extensively by the cryo-electron microscopy field, while electron flux thresholds which do not result in a functional change for biological samples within the hydrated environment of a transmission electron microscope liquid cell is less clear. Establishing these functional thresholds for biologically relevant samples is important for accurate interpretation of results from liquid cell experiments. Here we demonstrate the electron damage threshold of fluorescently tagged lipid bilayers by quantifying the change in fluorescence before and after electron exposure. We observe the reduction of fluorescent signal in bilayers by 25% after only 0.0005 e − /Å 2 and a reduction of over 90% after 0.01 e − /Å 2 . These results indicate that the loss of function occurs at irradiation thresholds far below a typical single high resolution (scanning) transmission electron microscopy image and orders of magnitude below fluxes used for preserving structural features with cryo-electron microscopy.

Moser, Trevor↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗

The influence of power spinning and annealing temperature on microstructures and properties of Cu-Sn alloy

Highlights: • The strengthening effect of power spinning is mainly achieved by strengthening fine grains and dislocations. • Twins formed by the aggregation and overlapping of stacking faults grow and widen • In power spinning of Cu-Sn alloy, plastic deformation is primarily powered by dislocation sliding. - Abstract: Electron back scatter diffraction pattern (EBSD), metallographic microscope (OM) and transmission electron microscope (TEM) are used to analyze the microstructural state of the Cu-Sn alloy before and after power spinning and annealing. The results show that after power spinning, the α phase grains are refined and gradually evolve into small and fine α{sub II} and deformed α{sub III} crystal grains, with an average grain size of about 2.2 μm. Work hardening results in massive network-like subgrain boundaries distributed in power spinning microstructure. Annealing at 400 °C contributes to the formation of dislocation cells and stacking faults, and high-angle grain boundaries (HABS) start to migrate and slide. After the formation of less defective equiaxed grains at 500 °C, twins continue to grow and widen based through continuous accumulation of stacking faults. Further testing of mechanical properties reveals that power spinning is conducive to the improvement of mechanical properties of Cu-Sn alloy.

36 MATERIALS SCIENCE↗