Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

{sup 197}Au(n,gamma) cross section in the resonance region

The (n,gamma) cross section of {sup 197}Au has been measured at n{sub T}OF in the resolved resonance region, up to 5 keV, with the aim of improving the accuracy in an energy range where it is not yet considered standard. The measurements were performed with two different experimental setup and detection techniques, the total energy method based on C{sub 6}D{sub 6} detectors, and the total absorption calorimetry based on a 4pi BaF{sub 2} array. By comparing the data collected with the two techniques, two accurate sets of neutron-capture yields have been obtained, which could be the basis for a new evaluation leading to an extended cross-section standard. Overall good agreement is found between the n{sub T}OF results and evaluated cross sections, with some significant exceptions for small resonances. A few resonances not included in the existing databases have also been observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices

Purpose: Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to develop a new approach for HDR brachytherapy by directly optimizing the dose distribution based on dosimetric criteria. Methods: The authors developed inverse planning by integer program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. They used their heuristic to compute dose plans for 20 anonymized prostate cancer image data sets from patients previously treated at their clinic database. Dosimetry was evaluated and compared to dosimetric criteria. Results: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 s on an Intel(R) Core{sup TM}2 Duo CPU 1.67 GHz processor with 3 Gib RAM. Conclusions: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. The authors have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, in both dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Q{sup 2} electrodisintegration of the deuteron

The break up of the deuteron is studied at high Q{sup 2} kinematics, with main motivation to probe the deuteron at small internucleon distances. For this, two main issues are studied: electromagnetic interaction of the virtual photon with the bound nucleon and the strong interactions of the produced baryons in the final state of the reaction. Within virtual nucleon approximation we developed a new prescription to account for the bound nucleon effects in the electromagnetic interaction. The final state interaction at high Q{sup 2} kinematics is calculated within generalized eikonal approximation (GEA). Comparison with the first experimental data confirm GEA's early prediction that the rescattering is maximal at {approx}70 deg. of recoil nucleon production relative to the momentum of the virtual photon. Also the forward recoil nucleon angles are best suited for studies of the deuteron at small distances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An absolute instrument for determination of the speed of sound in water

An apparatus for the absolute determination of the sound speed in water based on the time-of-flight technique is described. The time measurement is realized by hardware circuits and the distance measurement by a double-beam plane-mirror interferometer. A highly accurate time chip, with a resolution of approximately 90 ps, is employed for time measurements. The acoustic path length is adjustable and can be measured directly. Two transducers are used for transmitting and receiving ultrasonic signals without reflection. The transducers are immersed in a thermostatic vessel that maintains bath temperature with high stability. The speed of sound in pure water was measured at ambient pressure and at the temperatures 308 K, 303 K, 298 K, and 293 K. The achieved measurement uncertainties are 2 mK for temperature and 0.045 m/s for speed of sound. The results are compared to data from the literature, equation of state models, and measurements by two commercial sensors in the same experiment, showing excellent agreement among them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments with compton back scattered gamma beams (on GRAAL collaboration results)

Experimental study of photonuclear reactions using Compton back scattered gamma beams at intermediate energies (from pion photoproduction threshold up to a few GeV) is reviewed. The last review of this subject was published about 10 years ago. Since then, new fundamental data on nucleon spin structure and photonuclear excitation mechanisms have appeared in the literature. Principal attention in the present review is paid to the GRAAL (Grenoble Accelerateur Anneau Laser) experiment conducted at ESRF (European Synchrotron Radiation Facility). It is shown that, in addition to the principal polarization experimental program based on high degree of gamma beam polarization, new results on different applications have been obtained. For example, total photoabsorption and partial meson photoproduction cross sections were measured with high accuracy, and a new method for studying an interaction of unstable short-lived mesons with nuclear media (tagged mesons) was proposed. New results on anisotropy of the speed of light with respect to the dipole of cosmic microwave background radiation were evaluated. It is noted that new opportunities arise due to unique conditions appearing while conducting the experiments with the Compton back scattering technique, which provides the hard photon spectrum, high degree of beam polarization, and low backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation of W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of the MACS of {sup 159}Tb(n, γ) at kT=30 keV by Activation

The measurement of the Maxwellian-Averaged Cross-Section (MACS) of the {sup 159}Tb(n, γ) reaction at kT=30 keV by the activation technique is presented. An innovative method for the generation of Maxwellian neutron spectra at kT=30 keV is used. An experimental value of 2166±181 mb agrees well with the MACS value derived from the ENDF/B-VII.1 evaluation, but is higher than KADoNiS recommended value of 1580±150 mb. Astrophysical implications are studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring microstructural evolution of alloy 617 with non-linear acoustics for remaining useful life prediction; multiaxial creep-fatigue and creep-ratcheting

The research built upon a prior investigation to develop a unified constitutive model for design-­by-­analysis of the intermediate heat exchanger (IHX) for a very high temperature reactor (VHTR) design of next generation nuclear plants (NGNPs). Model development requires a set of failure data from complex mechanical experiments to characterize the material behavior. Therefore uniaxial and multiaxial creep-­fatigue and creep-­ratcheting tests were conducted on the nickel-­base Alloy 617 at 850 and 950°C. The time dependence of material behavior, and the interaction of time dependent behavior (e.g., creep) with ratcheting, which is an increase in the cyclic mean strain under load-­controlled cycling, are major concerns for NGNP design. This research project aimed at characterizing the microstructure evolution mechanisms activated in Alloy 617 by mechanical loading and dwell times at elevated temperature. The acoustic harmonic generation method was researched for microstructural characterization. It is a nonlinear acoustics method with excellent potential for nondestructive evaluation, and even online continuous monitoring once high temperature sensors become available. It is unique because it has the ability to quantitatively characterize microstructural features well before macroscale defects (e.g., cracks) form. The nonlinear acoustics beta parameter was shown to correlate with microstructural evolution using a systematic approach to handle the complexity of multiaxial creep-­fatigue and creep-­ratcheting deformation. Mechanical testing was conducted to provide a full spectrum of data for: thermal aging, tensile creep, uniaxial fatigue, uniaxial creep-­fatigue, uniaxial creep-ratcheting, multiaxial creep-fatigue, and multiaxial creep-­ratcheting. Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), and Optical Microscopy were conducted to correlate the beta parameter with individual microstructure mechanisms. We researched application of the harmonic generation method to tubular mechanical test specimens and pipes for nondestructive evaluation. Tubular specimens and pipes act as waveguides, thus we applied the acoustic harmonic generation method to guided waves in both plates and shells. Magnetostrictive transducers were used to generate and receive guided wave modes in the shell sample and the received signals were processed to show the sensitivity of higher harmonic generation to microstructure evolution. Modeling was initiated to correlate higher harmonic generation with the microstructure that will lead to development of a life prediction model that is informed by the nonlinear acoustics measurements.

36 MATERIALS SCIENCE↗

Nonlinear Ultrasonic Diagnosis and Prognosis of ASR Damage in Dry Cask Storage

Alkali-silica reaction (ASR) is a deleterious chemical process that may occur in cement-based materials such as mortars and concretes, where the hydroxyl ions in the highly alkaline pore solution attack the siloxane groups in the siliceous minerals in the aggregates. The reaction produces a cross-linked alkali-silica gel. The ASR gel swells in the presence of water. Expansion of the gel results in cracking when the swelling-induced stress exceeds the fracture toughness of the concrete. As the ASR continues, cracks may grow and eventually coalesce, which results in reduced service life and a decrease safety of concrete structures. Since concrete is widely used as a critical structural component in dry cask storage of used nuclear fuels, ASR damage poses a significant threat to the sustainability of long term dry cask storage systems. Therefore, techniques for effectively detecting, managing and mitigating ASR damage are needed. Currently, there are no nondestructive methods to accurately detect ASR damage in existing concrete structures. The only current way of accurately assessing ASR damage is to drill a core from an existing structure, and conduct microscopy on this drilled cylindrical core. Clearly, such a practice is not applicable to dry cask storage systems. To meet these needs, this research is aimed at developing (1) a suite of nonlinear ultrasonic quantitative nondestructive evaluation (QNDE) techniques to characterize ASR damage, and (2) a physics-based model for ASR damage evolution using the QNDE data. Outcomes of this research will provide a nondestructive diagnostic tool to evaluate the extent of the ASR damage, and a prognostic tool to estimate the future reliability and safety of the concrete structures in dry cask storage systems

42 ENGINEERING↗

Issues in protection from galactic cosmic rays

Radiation risks to astronauts depend on the microscopic fluctuations of energy absorption events in specific tissues. These fluctuations depend not only on the space environment but also on the modifications of that environment by the shielding provided by structures surrounding the astronauts and the attenuation characteristics of the astronaut's body. The effects of attenuation within the shield and body depends on the tissue biological response to these microscopic fluctuations. In the absence of an accepted method for estimating astronaut risk, we examined the attenuation characteristics using conventional linear energy transfer (LET)-dependent quality factors (as one means of representing relative biological effectiveness, RBE) and a track-structure repair model to fit cell transformation (and inactivation) data in the C3H10 T1/2 mouse cell system obtained for various ion beams. Although the usual aluminum spacecraft shield is effective in reducing dose equivalent with increasing shield thickness, cell transformation rates are increased for thin aluminum shields. Clearly, the exact nature of the biological response to LET and track width is critical to evaluation of biological protection factors provided by a shield design. A significant fraction of biological injury results from the LET region above 100 keV/mu m. Uncertainty in nuclear cross-sections results in a factor of 2-3 in the transmitted LET spectrum beyond depths of 15 g/cm2, but even greater uncertainty is due to the combined effects of uncertainty in biological response and nuclear parameters. Clearly, these uncertainties must be reduced before the shield design can be finalised.

NASA Discipline Number 45-10↗

OECD/NEA EGMPEBV Activities in Multi-Physics Verification and Validation

The Expert Group on Multi-Physics Experimental Data, Benchmarks and Validation (EGMPEBV) was established in 2014 by the Nuclear Energy Agency (NEA) at the Organization for Economic Co-operation and Development (OECD) to establish processes for certification of experimental data and development of benchmark models for validation of Multi-Physics (MP) Modeling and Simulation (M and S) computational systems. The aim of the group is to provide member countries with guidelines and recommendations for validating and improving their novel multi-physics simulations, and with an access to key experimental data. To be used to their full potential, these novel tools will require a more complex suite of validation experiments due to the multiple energy, spatial and temporal scales, as well as the number of physical phenomena being simulated. They will also require accurate measurements of all terms, including coupling terms representing the feedback effects, in situations where the appropriate experimental techniques and facilities might not exist today. However, the ability to conduct validation experiments has for certain applications progressed at a slower pace than for computational methods, or in some cases it has significantly regressed (through shutdown of facilities, or through retirement of experts). In addition, as modelling capabilities are reaching deeper levels in single physics phenomena and in coupled behaviors, appropriate experimental techniques may not yet exist. Validation of multiple physics models requires a wide variety of experimental data, which emphasizes the importance of maximizing the use of historically accumulated data to avoid the significant cost of performing similar experiments today. Moreover, the pedigree and quality of this data as it pertains to modern day simulation methods may be insufficient for rigorous validation of high fidelity modeling and simulation tools. Thus, these data can often exhibit limitations including a lack of measurement accuracy or a lack of knowledge of the measurement uncertainty in the experimental techniques; an absence of measurements for some critical parameters; an obscuring of relationships between individual physics phenomena owing to the output data resolution; or simply an inability to allow for a detailed reinterpretation of the experiments based on the documented information. The organization of the EGMPEBV relies on three Task Forces, focused on 1) Experimental Data Qualification and Benchmark Evaluation; 2) Methods and Standards, and 3) Specific Applications. Task Force 1 is focused on providing better and more accurate experimental datasets, which support validation of high-fidelity multi-physics modelling and simulation (M and S) tools. At the same time it has to consider the incompleteness of past experimental data sets (in terms of data, documentation, or uncertainties) and with the limited number of available multi-physics experimental facilities. Task Force 2 is designed to develop validation methods and guidelines, and uncertainty qualification for the new family of multi-physics, multi-scale codes in the context of emerging demands such as longer fuel cycles and power uprate. Task Force 3 is focused on applications of validation experiments and has the objective to organize multi-physics M and S benchmarks involving validation experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-I-87: Automated Liver Segmentation Method for CBCT Dataset by Combining Sparse Shape Composition and Probabilistic Atlas Construction

Purpose: The aiming of this study was to extract liver structures for daily Cone beam CT (CBCT) images automatically. Methods: Datasets were collected from 50 intravenous contrast planning CT images, which were regarded as training dataset for probabilistic atlas and shape prior model construction. Firstly, probabilistic atlas and shape prior model based on sparse shape composition (SSC) were constructed by iterative deformable registration. Secondly, the artifacts and noise were removed from the daily CBCT image by an edge-preserving filtering using total variation with L1 norm (TV-L1). Furthermore, the initial liver region was obtained by registering the incoming CBCT image with the atlas utilizing edge-preserving deformable registration with multi-scale strategy, and then the initial liver region was converted to surface meshing which was registered with the shape model where the major variation of specific patient was modeled by sparse vectors. At the last stage, the shape and intensity information were incorporated into joint probabilistic model, and finally the liver structure was extracted by maximum a posteriori segmentation.Regarding the construction process, firstly the manually segmented contours were converted into meshes, and then arbitrary patient data was chosen as reference image to register with the rest of training datasets by deformable registration algorithm for constructing probabilistic atlas and prior shape model. To improve the efficiency of proposed method, the initial probabilistic atlas was used as reference image to register with other patient data for iterative construction for removing bias caused by arbitrary selection. Results: The experiment validated the accuracy of the segmentation results quantitatively by comparing with the manually ones. The volumetric overlap percentage between the automatically generated liver contours and the ground truth were on an average 88%–95% for CBCT images. Conclusion: The experiment demonstrated that liver structures of CBCT with artifacts can be extracted accurately for following adaptive radiation therapy. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

60 APPLIED LIFE SCIENCES↗

Corrosion Testing of Carbon Steel Exposed to Sludge Heel Chemical Cleaning Solutions - 16109

As efforts continue to treat and dispose of millions of gallons of legacy radioactive materials from the production of nuclear weapons, non-compliant waste storage tanks will gradually be emptied of the bulk waste volume leaving heel materials requiring removal prior to tank closure. The waste heel slurries are distributed on the floor of large, million gallon tanks, which frequently contain numerous obstructions that limit the effectiveness of mechanical removal methods. As a result, chemical cleaning methods are needed for the effective removal of the heels as well as chemical scales that are present on the tank walls and other interior surfaces. Two tank cleaning technologies have already been implemented at the Savannah River Site (SRS): Low Temperature Aluminum Dissolution (LTAD) and Bulk Oxalic Acid Cleaning (BOAC). Recent chemical cleaning efforts on SRS Tank 12 were very successful with regard to bulk sludge heel (especially for Al, Fe, and U phases) and beta/gamma radionuclide removal. Although chemical cleaning using these technologies has been shown to be effective, no disposition path has been identified for oxalate added during BOAC, and insoluble oxalate salts are accumulating within the SRS tank farm and waste processing facilities (evaporators, etc.). Extensive sludge washing is also required to remove moderately soluble sodium oxalate salts prior to sludge vitrification in the SRS Defense Waste Processing Facility (DWPF). As a result, oxalate additions to the tank farm need to be minimized by the use of supplementary acids to assist sludge removal in OA or the use of other cleaning reagents or processing strategies. Previous SRNL testing revealed the importance of pH control for BOAC and recommended the use of a supplementary acid (dilute HNO{sub 3}) with OA to minimize oxalate additions. Primary drivers in SRS Tank Closure Performance Assessments, which evaluate the fate and impact of tank sludge residuals on a geological timescale, are the removal of alpha emitting radionuclides present at low concentrations such as Pu, Am, and Np, which are not highly soluble in currently utilized chemical cleaning reagents. Scoping studies conducted at SRNL revealed promising methods to dissolve the actinides within the HLW tank heels. Oxidation of the actinides with permanganate in either strong caustic (10 M NaOH) or dilute acidic (0.2 M HNO{sub 3}) solutions was shown to result in dissolution of oxy/hydroxide phases of these metals in the absence of major sludge phases. The waste tanks at SRS and Hanford are constructed of carbon steel. Carbon steel corrodes rapidly in most acidic and/or oxidizing environments. Previous electrochemical corrosion testing indicated that the corrosion rates in dilute HNO{sub 3} with OA may result in manageable corrosion rates, over short exposure periods. Additional corrosion testing was performed to provide data for the nitric acid/OA blend as well as the acid/permanganate and caustic permanganate based chemical cleaning solutions. Corrosion rates from the passive coupon tests for the nitric acid/oxalic acid blend were significantly greater than those observed previously with the electrochemical testing. This result may be due to simultaneous electrochemical and chemical dissolution of the steel. The corrosion rate data from the coupon tests in the nitric acid/oxalic acid blend were evaluated to determine the degree of potential structural damage. The corrosion rates, although relatively high, would not be expected to cause damage that would reduce the capacity of the tank primary wall if the process is completed within a month. The corrosivity of sodium permanganate in four proposed cleaning solutions, 1 nitric acid solution and 3 sodium hydroxide solutions, was studied by electrochemical methods at room temperature. The corrosion rates were significantly less aggressive than in the nitric acid/oxalic acid blend corrosion tests. Passive coupon tests needs to be performed in these solutions to ensure that chemical dissolution of the metal is not occurring simultaneously. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged {beta}{sup +}-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. Conclusions: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of Percutaneous Aspiration Thrombectomy vs. Anticoagulation Therapy to Treat Acute Iliofemoral Venous Thrombosis: 1-year Follow-up Results of a Randomised, Clinical Trial

PurposeThe purpose of this study was to compare the efficacy of percutaneous aspiration thrombectomy (PAT) followed by standard anticoagulant therapy, with anticoagulation therapy alone, for the treatment of acute proximal lower extremity deep vein thrombosis.MethodsIn this randomised, prospective study, 42 patients with acute proximal iliofemoral deep vein thrombosis documented via Doppler ultrasound examination, were separated into an interventional treatment group (16 males, 5 females, average age 51 years) and a medical treatment group (13 males, 8 females, average age 59 years). In the interventional group, PAT with large-lumen 9-F diameter catheterisation was applied, after initiation of standard anticoagulant therapy. Balloon angioplasty (n 19) and stent implementation (n: 14) were used to treat patients with residual stenosis (>50 %) after PAT. Prophylactic IVC filters were placed in two patients. The thrombus clearance status of the venous system was evaluated by venography. In both the medical and interventional groups, venous patency rates and clinical symptom scores were evaluated at months 1, 3, and 12 after treatment.ResultsDeep venous systems became totally cleared of thrombi in 12 patients treated with PAT. The venous patency rates in month 12 were 57.1 and 4.76 % in the interventional and medical treatment groups, respectively. A statistically significant improvement was observed in clinical symptom scores of the interventional group (PAT) with or without stenting (4.23 ± 0.51 before treatment; 0.81 ± 0.92 at month 12) compared with the medical treatment group (4.00 ± 0.63 before treatment; 2.43 ± 0.67 at month 12). During follow-up, four patients in the medical treatment and one in the interventional group developed pulmonary embolisms.ConclusionsFor treatment of acute deep vein thrombosis, PAT with or without stenting is superior to anticoagulant therapy alone in terms of both ensuring venous patency and improving clinical symptoms. PAT is a safe, inexpensive, and easily performed method of endovascular treatment with a low rate of major complications. Our present findings and literature data suggest that PAT can be used as first-line treatment in proximal deep vein thrombosis patients, especially when thrombolytic treatment is contraindicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗