Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Improved high-resolution mapping of phase-matching conditions in second-order nonlinear crystals via imaging

Large-aperture nonlinear crystals for frequency conversion and parametric amplification exhibit spatial variations in phase-matching conditions, which affect the performance of high-power laser systems. We demonstrate significant improvements in speed and resolution to a technique that spatially maps these phase-matching conditions using imaging of the beam resulting from detuned second-harmonic generation. The phase-matching conditions at the pyramidal sector boundary of partially deuterated potassium dihydrogen phosphate (DKDP) are mapped with sub-0.1-mm resolution. We examine the effect of further increases in scan rate on the precision of the technique and demonstrate a scan rate of 0.8 cm 2 per minute at the aforementioned resolution.

Wampler, R. [Univ. of Rochester, NY (United States↗

Upgrades to the gamma ray imager on DIII-D enabling access to high flux hard x-ray measurements during the runaway electron plateau phase (invited)

The Gamma Ray Imager (GRI) is a pinhole camera providing 2D imaging of MeV hard x-ray (HXR) bremsstrahlung emission from runaway electrons (REs) over the poloidal cross section of the DIII-D tokamak. We report a series of upgrades to the GRI expanding the access to RE scenarios from the diagnosis of a trace amount of REs to high flux HXR measurements during the RE plateau phase. We present the implementation of novel gamma ray detectors based on LYSO and YAP crystals coupled to multi-pixel photon counters, enabling a count rate in excess of 1 MHz. Finally, we highlight new insights into the RE physics discovered during the current quench and RE plateau phase experiments as the result of these upgrades.

Lvovskiy, A. (ORCID:0000000236491169)↗

MO-DE-207A-08: Four-Dimensional Cone-Beam CT Iterative Reconstruction with Time-Ordered Chain Graph Model for Non-Periodic Organ Motion and Deformation

Purpose: The purpose of this study is to propose a new concept of four-dimensional (4D) cone-beam CT (CBCT) reconstruction for non-periodic organ motion using the Time-ordered Chain Graph Model (TCGM), and to compare the reconstructed results with the previously proposed methods, the total variation-based compressed sensing (TVCS) and prior-image constrained compressed sensing (PICCS). Methods: CBCT reconstruction method introduced in this study consisted of maximum a posteriori (MAP) iterative reconstruction combined with a regularization term derived from a concept of TCGM, which includes a constraint coming from the images of neighbouring time-phases. The time-ordered image series were concurrently reconstructed in the MAP iterative reconstruction framework. Angular range of projections for each time-phase was 90 degrees for TCGM and PICCS, and 200 degrees for TVCS. Two kinds of projection data, an elliptic-cylindrical digital phantom data and two clinical patients’ data, were used for reconstruction. The digital phantom contained an air sphere moving 3 cm along longitudinal axis, and temporal resolution of each method was evaluated by measuring the penumbral width of reconstructed moving air sphere. The clinical feasibility of non-periodic time-ordered 4D CBCT reconstruction was also examined using projection data of prostate cancer patients. Results: The results of reconstructed digital phantom shows that the penumbral widths of TCGM yielded the narrowest result; PICCS and TCGM were 10.6% and 17.4% narrower than that of TVCS, respectively. This suggests that the TCGM has the better temporal resolution than the others. Patients’ CBCT projection data were also reconstructed and all three reconstructed results showed motion of rectal gas and stool. The result of TCGM provided visually clearer and less blurring images. Conclusion: The present study demonstrates that the new concept for 4D CBCT reconstruction, TCGM, combined with MAP iterative reconstruction framework enables time-ordered image reconstruction with narrower time-window.

60 APPLIED LIFE SCIENCES↗

Image inversion analysis of the HST OTA (Hubble Space Telescope Optical Telescope Assembly), phase A

Technical work during September-December 1990 consisted of: (1) analyzing HST point source images obtained from JPL; (2) retrieving phase information from the images by a direct (noniterative) technique; and (3) characterizing the wavefront aberration due to the errors in the Hubble Space Telescope (HST) mirrors, in a preliminary manner. This work was in support of JPL design of compensating optics for the next generation wide-field planetary camera on HST. This digital technique for phase retrieval from pairs of defocused images, is based on the energy transport equation between these image planes. In addition, an end-to-end wave optics routine, based on the JPL Code 5 prescription of the unaberrated HST and WFPC, was derived for output of the reference phase front when mirror error is absent. Also, the Roddier routine unwrapped the retrieved phase by inserting the required jumps of +/- 2(pi) radians for the sake of smoothness. A least-squares fitting routine, insensitive to phase unwrapping, but nonlinear, was used to obtain estimates of the Zernike polynomial coefficients that describe the aberration. The phase results were close to, but higher than, the expected error in conic constant of the primary mirror suggested by the fossil evidence. The analysis of aberration contributed by the camera itself could be responsible for the small discrepancy, but was not verified by analysis.

Litvak, M. M.↗

High-fidelity and high-resolution phase mapping of granites via confocal Raman imaging

Abstract In physical sciences such as chemistry and earth sciences, specifically for characterization of minerals in a rock, automated, objective mapping methods based on elemental analysis have replaced traditional optical petrography. However, mineral phase maps obtained from these newer approaches rely on conversion of elemental compositions to mineralogical compositions and thus cannot distinguish mineral polymorphs. Secondly, these techniques often require laborious sample preparations such as sectioning, polishing, and coating which are time-consuming. Here, we develop a new Raman imaging protocol that is capable of mapping unpolished samples with an auto-focusing Z-mapping feature that allows direct fingerprinting of different polymorphs. Specifically, we report a new methodology for generating high fidelity phase maps by exploiting characteristic peak intensity ratios which can be extended to any multi-phase, heterogenous system. Collectively, these enhancements allow us to rapidly map an unpolished granite specimen (~ 2 × 2 mm) with an exceptionally high accuracy (> 97%) and an extremely fine spatial resolution (< 0.3–2 µm).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid and noncontact photoacoustic tomography imaging system using an interferometer with high-speed phase modulation technique

We designed, fabricated, and tested a rapid and noncontact photoacoustic tomography (PAT) imaging system using a low-coherence interferometer with high-speed phase modulation technique. Such a rapid and noncontact probing system can greatly decrease the time of imaging. The proposed PAT imaging system is experimentally verified by capturing images of a simulated tissue sample and the blood vessels within the ear flap of a mouse (pinna) in vivo. The axial and lateral resolutions of the system are evaluated at 45 and ∼15 μm, respectively. The imaging depth of the system is 1 mm in a special phantom. Our results show that the proposed system opens a promising way to realize noncontact, real-time PAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-BRF-03: A Quasi-Cine CBCT Reconstruction Technique for Real-Time On- Board Target Tracking of Lung Cancer Treatment

Purpose: To develop a quasi-cine CBCT reconstruction technique that uses extremely-small angle (∼3°) projections to generate real-time high-quality lung CBCT images. Method: 4D-CBCT is obtained at the beginning and used as prior images. This study uses extremely-small angle (∼3°) on-board projections acquired at a single respiratory phase to reconstruct the CBCT image at this phase. An adaptive constrained free-form deformation (ACFD) method is developed to deform the prior 4D-CBCT volume at the same phase to reconstruct the new CBCT. Quasi-cine CBCT images are obtained by continuously reconstructing CBCT images at subsequent phases every 3° angle (∼0.5s). Note that the prior 4D-CBCT images are dynamically updated using the latest CBCT images. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the efficacy of ACFD. A lung patient was simulated with a tumor baseline shift of 2mm along superior-inferior (SI) direction after every respiratory cycle for 5 cycles. Limited-angle projections were simulated for each cycle. The 4D-CBCT reconstructed by these projections were compared with the ground-truth generated in XCAT.Volume-percentage-difference (VPD) and center-of-mass-shift (COMS) were calculated between the reconstructed and the ground-truth tumors to evaluate their geometric differences.The ACFD was also compared to a principal-component-analysis based motion-modeling (MM) method. Results: Using orthogonal-view 3° projections, the VPD/COMS values for tumor baseline shifts of 2mm, 4mm, 6mm, 8mm, 10mm were 11.0%/0.3mm, 25.3%/2.7mm, 22.4%/2.9mm, 49.5%/5.4mm, 77.2%/8.1mm for the MM method, and 2.9%/0.7mm, 3.9%/0.8mm, 6.2%/1mm, 7.9%/1.2mm, 10.1%/1.1mm for the ACFD method. Using orthogonal-view 0° projections (1 projection only), the ACFD method yielded VPD/COMS results of 5.0%/0.9mm, 10.5%/1.2mm, 15.1%/1.4mm, 20.9%/1.6mm and 24.8%/1.6mm. Using single-view instead of orthogonal-view projections yielded less accurate results for ACFD. Conclusion: The ACFD method accurately reconstructs snapshot CBCT images using orthogonal-view 3° projections. It has a great potential to provide real-time quasi-cine CBCT images for verification in lung radiation therapy. The research is supported by grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Self-imaging of transparent objects and structures in focusing of spatially phase-modulated laser radiation into a weakly absorbing medium

Self-imaging of transparent objects and structures in focusing of a spatially phase-modulated laser beam into an extended weakly absorbing medium is described. The laser power level that is necessary for effective imaging corresponds to the illuminating beam power when thermal self-defocusing starts evolving in the medium. The effect can be described in terms of the ideology of Zernike's classical phase-contrast method. Edge enhancement in visualised images of transparent objects is experimentally demonstrated. Self-imaging of a microscopic object in the form of transparent letters and long-lived refractive-index fluctuations in liquid glycerol is shown. Due to the adaptivity of the process under consideration, unlike the classical case, self-imaging occurs also in the situations where a beam is displaced (undergoes random walk) as a whole in the Fourier plane, for example, in the presence of thermal flows. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image sampling, reconstruction, and the effect of sample-scene phasing

This paper is a 1-D analysis of the degradation caused by image sampling and interpolative reconstruction. The analysis includes the sample-scene phase as an explicit random parameter and provides a complete characterization of this image degradation as the sum of two terms: one term accounts for the mean effect of undersampling (aliasing) and nonideal reconstruction averaged over all sample-scene phases; the other term accounts for variations about this mean. The results of this paper have application to the design and performance analysis of image scanning, sampling, and reconstruction systems.

Park, S. K.↗

Nonlinear optical processing with Fabry-Perot interferometers containing phase recording media

New techniques in nonlinear optical processing are explored, based on the operation of intensity level selection as performed by a Fabry-Perot interferometer containing a phase object. The image being processed is recorded on a medium between the mirrors as a spatially varying phase shift less than pi. The interferometer only transmits light through those portions of the object that corresponds to a single value of the phase and hence to a single intensity level in the input. More complicated operations such as thresholding and analog-to-digital conversion are performed by modulating the light source as the different levels are selected. Photoresist and lithium niobate have been used as phase objects, and experimental data for both are presented. Three kinds of Fabry-Perot interferometers have been used to demonstrate nonlinear processing using coherent and incoherent light. Color images have been produced with black and white inputs and white light illumination.

Bartholomew, B. J.↗

Ratioed scatter diagrams - An erotetic method for phase identification on complex surfaces using scanning Auger microscopy

By ratioing multiple Auger intensities and plotting a two-dimensional occupational scatter diagram while digitally scanning across an area, the number and elemental association of surface phases can be determined. This can prove a useful tool in scanning Auger microscopic analysis of complex materials. The technique is illustrated by results from an anomalous region on the reaction zone of a SiC/Ti-6Al-4V metal matrix composite material. The anomalous region is shown to be a single phase associated with sulphur and phosphorus impurities. Imaging of a selected phase from the ratioed scatter diagram is possible and may be a useful technique for presenting multiple scanning Auger images.

Browning, R.↗

Usefulness of rapid kV-switching dual energy CT in renal tumor characterization

Purpose: To investigate whether iodine content can discriminate between benign or malignant renal tumors, malign tumor subtypes, low-grade and high-grade tumors on rapid kv-switching dual-energy CT (rsDECT). Methods: This prospective study enrolled 95 patients with renal tumors who underwent rsDECT for tumor characterization between 2016 and 2018. Attenuation on true and virtual unenhanced images, absolute enhancement and enhancement ratio and iodine content of each lesion on nephrographic phase iodine density images were measured. Histopathological diagnosis was obtained following either surgery or core biopsy. Results: Eighty-five tumors were renal cell carcinoma (RCC) (56 clear cell, 20 papillary, 9 chromophobe) and 10 were benign (6 angiomyolipoma,4 oncocytoma). 46 tumors were low-grade and 23 high-grade. There was significant difference between iodine content of clear cell and non-clear cell (papillary + chromophobe) RCC (p < 0.001). However, no significant iodine content differences were found between papillary and chromophobe RCC, benign and malignant tumors, low-grade and high-grade tumors. The best cut-off iodine content for differentiating clear cell from non-clear cell RCC was 3.2 mg/ml and clear cell from papillary RCC was 2.9 mg/ml with a high sensitivity and specificity. Also, significant difference was found between attenuation values of true and virtual unenhanced images (p = 0.007). Mean iodine content, absolute enhancement and enhancement ratio were highly correlated. Conclusion: rsDECT contributes to renal tumor characterization by showing higher iodine content in clear cell RCCs compared with non-clear cell RCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3}/Ga{sub 2}O{sub 3} (010) heterostructures grown on β-Ga{sub 2}O{sub 3} (010) substrates by plasma-assisted molecular beam epitaxy

By systematically changing growth parameters, the growth of β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3}/Ga{sub 2}O{sub 3} (010) heterostructures by plasma-assisted molecular beam epitaxy was optimized. Through variation of the Al flux under O-rich conditions at 600 °C, β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} (010) layers spanning ∼10% to ∼18% Al{sub 2}O{sub 3} were grown directly on β-Ga{sub 2}O{sub 3} (010) substrates. Nominal β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} (010) compositions were determined through Al:Ga flux ratios. With x = ∼0.18, the β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} (020) layer peak in a high-resolution x-ray diffraction (HRXRD) ω-2θ scan was barely discernible, and Pendellösung fringes were not visible. This indicated that the phase stability limit of Al{sub 2}O{sub 3} in β-Ga{sub 2}O{sub 3} (010) at 600 °C was less than ∼18%. The substrate temperature was then varied for a series of β-(Al{sub ∼0.15}Ga{sub ∼0.85}){sub 2}O{sub 3} (010) layers, and the smoothest layer was grown at 650 °C. The phase stability limit of Al{sub 2}O{sub 3} in β-Ga{sub 2}O{sub 3} (010) appeared to increase with growth temperature, as the β-(Al{sub x}Ga{sub 1−x}){sub 2}O{sub 3} (020) layer peak with x = ∼0.18 was easily distinguishable by HRXRD in a sample grown at 650 °C. Cross-sectional transmission electron microscopy (TEM) indicated that β-(Al{sub ∼0.15}Ga{sub ∼0.85}){sub 2}O{sub 3} (010) layers (14.4% Al{sub 2}O{sub 3} by energy dispersive x-ray spectroscopy) grown at 650 °C were homogeneous. β-(Al{sub ∼0.20}Ga{sub ∼0.80}){sub 2}O{sub 3} (010) layers, however, displayed a phase transition. TEM images of a β-(Al{sub ∼0.15}Ga{sub ∼0.85}){sub 2}O{sub 3}/Ga{sub 2}O{sub 3} (010) superlattice grown at 650 °C showed abrupt layer interfaces and high alloy homogeneity.

36 MATERIALS SCIENCE↗

Phase Retrieval Using a Genetic Algorithm on the Systematic Image-Based Optical Alignment Testbed

NASA s Marshall Space Flight Center s Systematic Image-Based Optical Alignment (SIBOA) Testbed was developed to test phase retrieval algorithms and hardware techniques. Individuals working with the facility developed the idea of implementing phase retrieval by breaking the determination of the tip/tilt of each mirror apart from the piston motion (or translation) of each mirror. Presented in this report is an algorithm that determines the optimal phase correction associated only with the piston motion of the mirrors. A description of the Phase Retrieval problem is first presented. The Systematic Image-Based Optical Alignment (SIBOA) Testbeb is then described. A Discrete Fourier Transform (DFT) is necessary to transfer the incoming wavefront (or estimate of phase error) into the spatial frequency domain to compare it with the image. A method for reducing the DFT to seven scalar/matrix multiplications is presented. A genetic algorithm is then used to search for the phase error. The results of this new algorithm on a test problem are presented.

Taylor, Jaime R.↗

Effect of Clouds on Optical Imaging of the Space Shuttle During the Ascent Phase: A Statistical Analysis Based on a 3D Model

Clouds are highly effective in obscuring optical images of the Space Shuttle taken during its ascent by ground-based and airborne tracking cameras. Because the imagery is used for quick-look and post-flight engineering analysis, the Columbia Accident Investigation Board (CAIB) recommended the return-to-flight effort include an upgrade of the imaging system to enable it to obtain at least three useful views of the Shuttle from lift-off to at least solid rocket booster (SRB) separation (NASA 2003). The lifetimes of individual cloud elements capable of obscuring optical views of the Shuttle are typically 20 minutes or less. Therefore, accurately observing and forecasting cloud obscuration over an extended network of cameras poses an unprecedented challenge for the current state of observational and modeling techniques. In addition, even the best numerical simulations based on real observations will never reach "truth." In order to quantify the risk that clouds would obscure optical imagery of the Shuttle, a 3D model to calculate probabilistic risk was developed. The model was used to estimate the ability of a network of optical imaging cameras to obtain at least N simultaneous views of the Shuttle from lift-off to SRB separation in the presence of an idealized, randomized cloud field.

FROM↗

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics↗

An experimental study of ovarian cancer imaging and therapy by paclitaxel-loaded phase-transformation lipid nanoparticles combined with low-intensity focused ultrasound

Highlights: • PTX-anti-LHRHR-PTNPs is expected to become a new type of ultrasound contrast agent. • LIFU can enhance the efficiency of PTX-anti-LHRHR-PTNPs. • For ovarian cancer, PTX-anti-LHRHR-PTNPs has a good therapeutic effect. Drug-loaded phase-transformation lipid nanoparticles (NPs) combined with low-intensity focused ultrasound (LIFU) for ultrasound molecular imaging and therapy, which is a very promising drug carrier and can provide both physical and chemical therapeutics, simultaneously. We successfully prepared the paclitaxel (PTX) loaded anti-LHRHR targeted phase-transformation lipid nanoparticles (PTX-anti-LHRHR-PTNPs) for ovarian cancer in this study combined with LIFU has the following characteristics: On the one hand, it showed smaller size and greater stability than blood cells, which significantly prolonged its half-life in the body, and can actively target ovarian cancer OVCAR-3 cells, and smoothly penetrate the endothelial gap into the tumor site for specifically killing the ovarian cancer cells. Thereby, the special drug carrier improved the therapeutic effect and reduced toxic and side effects, maximized the protection of normal tissues and minimized adverse reactions. On the other hand, PTX-anti-LHRHR-PTNPs can be targeted to focus after being injected intravenously and remain in the tumor target tissue for a long time. At the same time, liquid-gas phase-transformation can occur under LIFU triggering, resulting in more ideal and sustained ultrasound imaging effects. Then acoustic contrast agent is used to develop the molecular level of ultrasound scattering, so as to evaluate the diseased tissue from the molecular level.

60 APPLIED LIFE SCIENCES↗

Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗