Optical emission spectroscopy and imaging of low-pressure N2 plasmas generated by intense fast-pulsed electron beams

An optical emission spectroscopic (OES) and imaging characterization is conducted on N2 plasmas generated by a 100 keV fast-pulsed electron beam. The electron beams are injected into an N2 gas filled volume with a current of 4.5 kA (300 A/cm2) and a 100 ns pulse width. The characterization is conducted at the pressures, 1 Torr and 0.1 Torr, corresponding to two distinct regimes that exhibit significantly different plasma dynamics. Beam impact ionization is shown to be a primary mechanism for producing low temperature plasmas at 1 Torr during beam output. After beam termination, ionization by an inductive electric field becomes the primary mechanism for plasma formation later in time for both pressures. OES and plasma imaging are used in this work as a diagnostic tool to track the distribution of electronic, vibrational, and rotational state transitions and ionized species. This is achieved with the use of a multi-resolution suite of spectrometers capable of acquiring time-resolved spectra. Vibrational and rotational bands of the N2 second positive system (C3Πu→B3Πg) and the N2+ first negative system (B2Σu+→X2Σg+) are identified in both regimes as well as N+ states exclusively in the lower pressure regime. Vibrational and rotational spectra are shown to track the evolution of the time-varying plasma current. Plasma imaging also reveals spatially nonuniform plasma emission at 0.1 Torr. A few hundred shots are recorded to fully characterize the emissions, and results are shown to be highly reproducible (≤±1% with 2σ confidence).

Kaiser, E. R. (ORCID:0000000336493938)↗

ADAPTIVE OPTICS IMAGES OF KEPLER OBJECTS OF INTEREST

All transiting planets are at risk of contamination by blends with nearby, unresolved stars. Blends dilute the transit signal, causing the planet to appear smaller than it really is, or produce a false-positive detection when the target star is blended with eclipsing binary stars. This paper reports on high spatial-resolution adaptive optics images of 90 Kepler planetary candidates. Companion stars are detected as close as 0.''1 from the target star. Images were taken in the near-infrared (J and Ks bands) with ARIES on the MMT and PHARO on the Palomar Hale 200 inch telescope. Most objects (60%) have at least one star within 6'' separation and a magnitude difference of 9. Eighteen objects (20%) have at least one companion within 2'' of the target star; six companions (7%) are closer than 0.''5. Most of these companions were previously unknown, and the associated planetary candidates should receive additional scrutiny. Limits are placed on the presence of additional companions for every system observed, which can be used to validate planets statistically using the BLENDER method. Validation is particularly critical for low-mass, potentially Earth-like worlds, which are not detectable with current-generation radial velocity techniques. High-resolution images are thus a crucial component of any transit follow-up program.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF BARS AND TRANSIENT SPIRALS ON THE VERTICAL HEATING IN DISK GALAXIES

The nature of vertical heating of disk stars in the inner as well as the outer region of disk galaxies is studied. The galactic bar (which is the strongest non-axisymmetric pattern in the disk) is shown to be a potential source of vertical heating of the disk stars in the inner region. Using a nearly self-consistent high-resolution N-body simulation of disk galaxies, the growth rate of the bar potential is found to be positively correlated with the vertical heating exponent in the inner region of galaxies. We also characterize the vertical heating in the outer region where the disk dynamics is often dominated by the presence of transient spiral waves and mild bending waves. Our simulation results suggest that the non-axisymmetric structures are capable of producing the anisotropic heating of the disk stars.

79 ASTRONOMY AND ASTROPHYSICS↗

TOWARD PRECISE AGES FOR SINGLE STARS IN THE FIELD. GYROCHRONOLOGY CONSTRAINTS AT SEVERAL Gyr USING WIDE BINARIES. I. AGES FOR INITIAL SAMPLE

We present a program designed to obtain age-rotation measurements of solar-type dwarfs to be used in the calibration of gyrochronology relations at ages of several Gyr. This is a region of parameter space crucial for the large-scale study of the Milky Way, and where the only constraint available today is that provided by the Sun. Our program takes advantage of a set of wide binaries selected so that one component is an evolved star and the other is a main-sequence star of FGK type. In this way, we obtain the age of the system from the evolved star, while the rotational properties of the main-sequence component provide the information relevant for gyrochronology regarding the spin-down of solar-type stars. By mining currently available catalogs of wide binaries, we assemble a sample of 37 pairs well positioned for our purposes: 19 with turnoff or subgiant primaries and 18 with white dwarf components. Using high-resolution optical spectroscopy, we measure precise stellar parameters for a subset of 15 of the pairs with turnoff/subgiant components and use these to derive isochronal ages for the corresponding systems. Ages for 16 of the 18 pairs with white dwarf components are taken from the literature. The ages of this initial sample of 31 wide binaries range from 1 to 9 Gyr, with precisions better than {approx}20% for almost half of these systems. When combined with measurements of the rotation period of their main-sequence components, these wide binary systems would potentially provide a similar number of points useful for the calibration of gyrochronology relations at very old ages.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of dynamic magnetic fields with spin-polarized neutron beams

Precession of neutron spin in a magnetic field can be used for mapping of a magnetic field distribution, as demonstrated previously for static magnetic fields at neutron beamline facilities. The fringing in the observed neutron images depends on both the magnetic field strength and the neutron energy. In this paper we demonstrate the feasibility of imaging periodic dynamic magnetic fields using a spin-polarized cold neutron beam. Our position-sensitive neutron counting detector, providing with high precision both the arrival time and position for each detected neutron, enables simultaneous imaging of multiple phases of a periodic dynamic process with microsecond timing resolution. The magnetic fields produced by 5- and 15-loop solenoid coils of 1 cm diameter, are imaged in our experiments with ~100 μm resolution for both dc and 3 kHz ac currents. Our measurements agree well with theoretical predictions of fringe patterns formed by neutron spin precession. We also discuss the wavelength dependence and magnetic field quantification options using a pulsed neutron beamline. Furthermore, the ability to remotely map dynamic magnetic fields combined with the unique capability of neutrons to penetrate various materials (e.g., metals), enables studies of fast periodically changing magnetic processes, such as formation of magnetic domains within metals due to the presence of ac magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Breath analysis by ultra-sensitive broadband laser spectroscopy detects SARS-CoV-2 infection

Rapid testing is essential to fighting pandemics such as coronavirus disease 2019 (COVID-19), the disease caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Exhaled human breath contains multiple volatile molecules providing powerful potential for non-invasive diagnosis of diverse medical conditions. We investigated breath detection of SARS-CoV-2 infection using cavity-enhanced direct frequency comb spectroscopy (CE-DFCS), a state-of-the-art laser spectroscopic technique capable of a real-time massive collection of broadband molecular absorption features at ro-vibrational quantum state resolution and at parts-per-trillion volume detection sensitivity. Using a total of 170 individual breath samples (83 positive and 87 negative with SARS-CoV-2 based on reverse transcription polymerase chain reaction tests), we report excellent discrimination capability for SARS-CoV-2 infection with an area under the receiver-operating-characteristics curve of 0.849(4). Our results support the development of CE-DFCS as an alternative, rapid, non-invasive test for COVID-19 and highlight its remarkable potential for optical diagnoses of diverse biological conditions and disease states.

60 APPLIED LIFE SCIENCES↗

Kinetic mechanism of V-shaped twinning in 3C/4H-SiC heteroepitaxy

The authors investigated the kinetic mechanism of V-shaped twinning in 3C/4H-SiC heteroepitaxy. A fourfold V-shaped twinning complex was found, and its interface was measured with high-resolution transmission electron microscopy (HRTEM). Two linear coherent boundaries and a nonlinear incoherent boundary (also called the double-position boundary) were observed. On the basis of the HRTEM results, the authors proposed an adatom migration growth model, in which the activation barrier at the coherent boundary is much lower than that at the incoherent boundary. From a kinetic perspective, adatoms are prone to migrate to the side of the boundary with the lower potential energy if they have sufficient thermal energy to overcome the activation barrier. In the case of a coherent boundary, the growth rates of the domains either side of the boundary can be balanced through the intermigration of adatoms, leading to a linear boundary. Conversely, it is difficult for adatoms to migrate across an incoherent boundary, which results in asynchronous growth rates and a nonlinear boundary.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation

Motion of thoracic tumors with respiration presents a challenge for three-dimensional (3D) conformal radiation therapy treatment. Validation of techniques aimed at measuring and minimizing the effects of respiratory motion requires a realistic deformable phantom for use as a gold standard. The purpose of this study was to develop and study the characteristics of a reproducible, tissue equivalent, deformable lung phantom. The phantom consists of a Lucite cylinder filled with water containing a latex balloon stuffed with dampened natural sponges. The balloon is attached to a piston that mimics the human diaphragm. Nylon wires and Lucite beads, emulating vascular and bronchial bifurcations, were uniformly glued at various locations throughout the sponges. The phantom is capable of simulating programmed irregular breathing patterns with varying periods and amplitudes. A tissue equivalent tumor, suitable for holding radiochromic film for dose measurements was embedded in the sponge. To assess phantom motion, eight 3D computed tomography data sets of the static phantom were acquired for eight equally spaced positions of the piston. The 3D trajectories of 12 manually chosen point landmarks and the tumor center-of-mass were studied. Motion reproducibility tests of the deformed phantom were established on seven repeat scans of three different states of compression. Deformable image registration (DIR) of the extreme breathing phases was performed. The accuracy of the DIR was evaluated by visual inspection of image overlays and quantified by the distance-to-agreement (DTA) of manually chosen point landmarks and triangulated surfaces obtained from 3D contoured structures. In initial tests of the phantom, a 20-mm excursion of the piston resulted in deformations of the balloon of 20 mm superior-inferior, 4 mm anterior-posterior, and 5 mm left-right. The change in the phantom mean lung density ranged from 0.24 (0.12 SD) g/cm{sup 3} at peak exhale to 0.19 (0.12 SD) g/cm{sup 3} at peak inhale. The SI displacement of the landmarks varied between 94% and 3% of the piston excursion for positions closer and farther away from the piston, respectively. The reproducibility of the phantom deformation was within the image resolution (0.7x0.7x1.25 mm{sup 3}). Vector average registration accuracy based on point landmarks was found to be 0.5 (0.4 SD) mm. The tumor and lung mean 3D DTA obtained from triangulated surfaces were 0.4 (0.1 SD) mm and 1.0 (0.8 SD) mm, respectively. This phantom is capable of reproducibly emulating the physically realistic lung features and deformations and has a wide range of potential applications, including four-dimensional (4D) imaging, evaluation of deformable registration accuracy, 4D planning and dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Community Structure of Arbuscular Mycorrhizal Fungi in Soils of Switchgrass Harvested for Bioenergy

We assessed the different species of beneficial fungi living in agricultural fields of switchgrass, a large grass grown for biofuels, using high-resolution DNA sequencing. Contrary to our expectations, the fungi were not greatly affected by fertilization. However, we found a positive relationship between plant productivity and the number of families of beneficial fungi at one site. Furthermore, we sequenced many species that could not be identified with existing reference databases. One group of fungi was highlighted in an earlier study for being widely distributed but of unknown taxonomy. We discovered that this group belonged to a family called Pervetustaceae , which may benefit switchgrass in stressful environments. To produce higher-yielding switchgrass in a more sustainable manner, it could help to study these undescribed fungi and the ways in which they may contribute to greater switchgrass yield in the absence of fertilization.

59 BASIC BIOLOGICAL SCIENCES↗

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

Cluster Difference Imaging Photometric Survey. II. TOI 837: A Young Validated Planet in IC 2602

We report the discovery of TOI 837b and its validation as a transiting planet. We characterize the system using data from the NASA Transiting Exoplanet Survey Satellite mission, the ESA Gaia mission, ground-based photometry from El Sauce and ASTEP400, and spectroscopy from CHIRON, FEROS, and Veloce. We find that TOI 837 is a T = 9.9 mag G0/F9 dwarf in the southern open cluster IC 2602. The star and planet are therefore 35$_{-5}^{+11}$ million years old. Combining the transit photometry with a prior on the stellar parameters derived from the cluster color–magnitude diagram, we find that the planet has an orbital period of 8.3 days and is slightly smaller than Jupiter (R p =0.77$_{-0.07}^{+0.09}$ R Jup ). From radial velocity monitoring, we limit M p sin i to less than 1.20 M Jup (3σ). The transits either graze or nearly graze the stellar limb. Grazing transits are a cause for concern, as they are often indicative of astrophysical false-positive scenarios. Our follow-up data show that such scenarios are unlikely. Our combined multicolor photometry, high-resolution imaging, and radial velocities rule out hierarchical eclipsing binary scenarios. Background eclipsing binary scenarios, though limited by speckle imaging, remain a 0.2% possibility. TOI 837b is therefore a validated adolescent exoplanet. The planetary nature of the system can be confirmed or refuted through observations of the stellar obliquity and the planetary mass. Such observations may also improve our understanding of how the physical and orbital properties of exoplanets change in time.

79 ASTRONOMY AND ASTROPHYSICS↗

Proposal for a Non-Interceptive Spatio-Temporal Correlation Monitor

Designs toward TeV-range electron-positron linear colliders include a non-zero crossing angle colliding scheme at the interaction point to mitigate instabilities and possible background. Maximizing the luminosity when operating with non-zero crossing angles requires the use of 'crab' cavities to impart a well-defined spatio-temporal correlation. In this paper we propose a novel noninterceptive diagnostic capable of measuring and monitoring the spatio-temporal correlation, i.e. the transverse position of sub-picosecond time slices, within bunch. An analysis of the proposed scheme, its spatio-temporal resolution and its limitations are quantified. Finally, the design of a proof-of-principle experiment in preparation for the Fermilab's A0 photoinjector is presented.

43 PARTICLE ACCELERATORS↗

Introduction to phasing

This introductory paper to the CCP4 weekend on experimental phasing introduces the concept of the ‘phase problem’ for non-experts. Modern methods of phasing are explored, including some recent examples that can be downloaded as tutorials. When collecting X-ray diffraction data from a crystal, we measure the intensities of the diffracted waves scattered from a series of planes that we can imagine slicing through the crystal in all directions. From these intensities we derive the amplitudes of the scattered waves, but in the experiment we lose the phase information; that is, how we offset these waves when we add them together to reconstruct an image of our molecule. This is generally known as the ‘phase problem’. We can only derive the phases from some knowledge of the molecular structure. In small-molecule crystallography, some basic assumptions about atomicity give rise to relationships between the amplitudes from which phase information can be extracted. In protein crystallography, these ab initio methods can only be used in the rare cases in which there are data to at least 1.2 Å resolution. For the majority of cases in protein crystallography phases are derived either by using the atomic coordinates of a structurally similar protein (molecular replacement) or by finding the positions of heavy atoms that are intrinsic to the protein or that have been added (methods such as MIR, MIRAS, SIR, SIRAS, MAD, SAD or combinations of these). The pioneering work of Perutz, Kendrew, Blow, Crick and others developed the methods of isomorphous replacement: adding electron-dense atoms to the protein without disturbing the protein structure. Nowadays, methods from small-molecule crystallography can be used to find the heavy-atom substructure and the phases for the whole protein can be bootstrapped from this prior knowledge. More recently, improved X-ray sources, detectors and software have led to the routine use of anomalous scattering to obtain phase information from either incorporated selenium or intrinsic sulfurs. In the best cases, only a single set of X-ray data (SAD) is required to provide the positions of the anomalous scatters, which together with density-modification procedures can reveal the structure of the complete protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

THE STELLAR KINEMATIC CENTER AND THE TRUE GALACTIC NUCLEUS OF NGC 253

We present the first sub-arcsecond resolution two-dimensional stellar kinematics and X-ray observations of the prototypical starburst galaxy NGC 253 which define the position and nature of the galactic nucleus. These observations comprise some of the best probes of the central 300 pc of NGC 253, the nearest massive galaxy undergoing a powerful starburst, and will allow us to gain more insight into the nature of the centers of starburst galaxies. We get an estimate of the stellar kinematic center location corresponding to an area of r {approx} 1.''2 centered {approx}0.''7 southwest (SW) from the radio core, and historically presumed nucleus, TH2. Newly processed Chandra data reveal a central point-like hard X-ray source (X-1) lying {approx}0.''4 SW from the kinematic center. Very accurate alignment between radio, infrared, and X-ray sources in the nuclear region shows that TH2, the IR photometric center, and X-1 are not associated with each other. As the kinematic center is consistent with the positions of TH2 and X-1, and both could be a manifestation of nuclear activity, we consider the two as possible galactic nucleus candidates. Although TH2 is the strongest compact radio source in the nuclear region, it does not have any infrared, optical, or X-ray counterparts. If the kinematic center is associated with this source, by analogy we suggest that the nucleus of NGC 253 resembles our Galactic center Sgr A*. On the other hand, X-1 is a heavily absorbed object (N{sub H} = 7.5 x 10{sup 23} cm{sup -2}) only detected at energies >2 keV (L{sub 2-10{sub keV}} {approx} 10{sup 40} erg s{sup -1}). If X-1 is instead associated with the kinematic center, the nucleus of NGC 253 is compatible with an obscured low-luminosity active galactic nucleus (AGN) or a spatially resolved super star cluster (SSC) brightening up in X-rays most probably due to young supernovae or supernova remnants, a situation also observed in the nuclear starburst of M82. If no SSC is associated with the kinematic center, we conclude that NGC 253 is a galaxy in which a strong starburst and a weak AGN (either TH2 or X-1) coexist. Results from few other high-resolution studies of nearby starburst galaxies (e.g., M82, NGC 5253, NGC 4945) indicate that the AGN in these systems, if present, is always in the low-luminosity regime. This may indicate that the onset of nuclear activity in galaxies is closely related with the occurrence of star formation, and that we are witnessing the emergence or disappearance of an AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Bond-length dependence of attosecond ionization delays in O 2 arising from electron correlation to a shape resonance

We experimentally and theoretically demonstrate that electron correlation can cause the bond-length sensitivity of a shape resonance to induce an unexpected vibrational state–dependent ionization delay in a nonresonant channel. This discovery was enabled by a high-resolution attosecond-interferometry experiment based on a 400-nm driving and dressing wavelength. The short-wavelength driver results in a 6.2–electron volt separation between harmonics, markedly reducing the spectral overlap in the measured interferogram. We demonstrate the promise of this method on O 2 , a system characterized by broad vibrational progressions and a dense photoelectron spectrum. We measure a 40-attosecond variation of the photoionization delays over the X 2 Π g vibrational progression. Multichannel calculations show that this variation originates from a strong bond-length dependence of the energetic position of a shape resonance in the b 4 Σ$^{-}_{g}$ channel, which translates to the observed effects through electron correlation. The unprecedented energy resolution and delay accuracies demonstrate the promise of visible-light–driven molecular attosecond interferometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗