Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local electronic effects and irradiation resistance in high-entropy alloys

High-entropy alloys are multicomponent solid solutions in which various elements with different chemistries and sizes occupy the same crystallographic lattice sites. Thus, none of the atoms perfectly fit the lattice site, giving rise to considerable local lattice distortions and atomic-level stresses. These characteristics can be beneficial for performance under both radiation and in a high-temperature environment, making them attractive candidates as nuclear materials. We discuss electronic origin of the atomic-level stresses based upon first-principles calculations using a density functional theory approach.

36 MATERIALS SCIENCE↗

Decreasing Temporal Lobe Dose With Five-Field Intensity-Modulated Radiotherapy for Treatment of Pituitary Macroadenomas

Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV) = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving {>=}25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p < 10{sup -7} for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Tumor Tracking in the Lung Using an Electromagnetic Tracking System

Purpose: To describe the first use of the commercially available Calypso 4D Localization System in the lung. Methods and Materials: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R{sup 2}) were tabulated for all 42 tracks. Results: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Conclusions: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1 Study of Dose Escalation in Hypofractionated Proton Beam Therapy for Non-Small Cell Lung Cancer

Background: Many patients with locally advanced non-small cell lung cancer (NSCLC) cannot undergo concurrent chemotherapy because of comorbidities or poor performance status. Hypofractionated radiation regimens, if tolerable, may provide an option to these patients for effective local control. Methods and Materials: Twenty-five patients were enrolled in a phase 1 dose-escalation trial of proton beam therapy (PBT) from September 2010 through July 2012. Eligible patients had histologically documented lung cancer, thymic tumors, carcinoid tumors, or metastatic thyroid tumors. Concurrent chemotherapy was not allowed, but concurrent treatment with biologic agents was. The dose-escalation schema comprised 15 fractions of 3 Gy(relative biological effectiveness [RBE])/fraction, 3.5 Gy(RBE)/fraction, or 4 Gy(RBE)/fraction. Dose constraints were derived from biologically equivalent doses of standard fractionated treatment. Results: The median follow-up time for patients alive at the time of analysis was 13 months (range, 8-28 months). Fifteen patients received treatment to hilar or mediastinal lymph nodes. Two patients experienced dose-limiting toxicity possibly related to treatment; 1 received 3.5-Gy(RBE) fractions and experienced an in-field tracheoesophageal fistula 9 months after PBT and 1 month after bevacizumab. The other patient received 4-Gy(RBE) fractions and was hospitalized for bacterial pneumonia/radiation pneumonitis 4 months after PBT. Conclusion: Hypofractionated PBT to the thorax delivered over 3 weeks was well tolerated even with significant doses to the lungs and mediastinal structures. Phase 2/3 trials are needed to compare the efficacy of this technique with standard treatment for locally advanced NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicomponent pyrochlore solid solutions with uranium incorporation – A new perspective of materials design for nuclear applications

Multicomponent pyrochlore solid solutions with and without uranium incorporation were fabricated and their thermal-mechanical properties were characterized. Multicomponent pyrochlore solid solutions without uranium exhibit comparable thermal conductivity and higher mechanical strength compared to baseline single component rare-earth titanate pyrochlore (A 2 Ti 2 O 7 ). Uranium incorporation reduces hardness as compared with single component compositions. High entropy pyrochlore with uranium displays the highest thermal conductivity within multicomponent pyrochlore solid solutions with significantly better mechanical properties than UO 2 . The measured thermal conductivity correlates well with A-site cation mixing entropy and a modified size disorder parameter, and thus the size disorder and mixing entropy could be good indicators for predicting thermal conductivity of multicomponent pyrochlore solid solutions. This work opens up the possibility of designing multicomponent oxide solid solutions by controlling their chemical disorder/mixing entropy to achieve acceptable thermal-mechanical properties, desired radiation and corrosion performance for potential nuclear waste form and inert matrix fuel applications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation tolerance study on irradiated AC-coupled, poly-silicon biased, p-on-n silicon strip sensors developed in India

The silicon sensors to be deployed in the next generation high energy physics experiments for operation in high luminosity scenarios, will require a high level of radiation tolerance. AC-coupled silicon strip sensors integrated with biasing poly-silicon resistors have been fabricated in collaboration with the Bharat Electronics Limited foundry using 4 inch n-type wafers in p-on-n configuration. Several sensors were irradiated with protons at different fluences at the Karlsruhe Cyclotron facility under the Advanced European Infrastructures for Detectors at Accelerators (AIDA) program. This paper reports on these radiation hardness study performed on the AC-coupled silicon sensors fabricated in India. The characterization comprises of electrical tests, including total current, voltage and strip scans and charge collection studies.

AC-coupled↗

The total neutron cross section of liquid and solid ammonia

Ammonia is a material of interest for future neutron moderators at high-power sources due to its high hydrogen density, low melting point, and resistance to polymerization in an intense radiation field. Its performance in such applications cannot currently be calculated due to the absence of suitable computer models for the interaction of neutrons with ammonia under relevant conditions. In an effort to develop suitable scattering kernels for computer simulations of moderator performance, we have conducted a series of Density Functional Theory and Molecular Dynamics calculations of the molecular-level thermal properties of ammonia at various temperatures within both the solid and liquid phases. In this paper, we compare computer calculations for the energy-dependent total neutron cross section of ammonia, based on these models, to experimental measurements of those cross sections at temperatures of 221 K, 180 K, and 35 K. The experimental data were collected over an energy range from 0.1 meV to 10 eV using time-of-flight techniques at the Low Energy Neutron Source (LENS) facility at Indiana University. This comparison provides a first validation in the development of thermal scattering libraries for Monte Carlo source design simulations based on liquid and solid ammonia. In conclusion, we also provide some insights into where additional development of tools for creating such models may be needed.

Ammonia↗

Doping with phosphorus reduces anion vacancy disorder in CdSeTe semiconductors enabling higher solar cell efficiency

Doping is used in many pn junction devices, such as polycrystalline solar cells, to increase the strength of the junction field to assist charge carrier collection and thus partially mitigate nonradiative recombination losses. We demonstrate a different doping characteristic for inorganic solar cells: using dopants to reduce charge carrier trapping and electronic band tails. Alloying CdTe with Se to form CdSeTe semiconductor reduced recombination, but CdSeTe has more complex defect states which can limit further efficiency gains due to charge carrier trapping and trap-limited mobility. Doping CdSeTe with P (but not N, As, or Sb in this study) reduces band tails (Urbach energies) and lessens the impact of the near valence band trap states, with ambipolar mobilities improving to >50 cm 2 V −1 s −1 , fill factor increasing from 76% to 79%, and efficiencies increasing by 0.9% absolute. Simulations are used to show how such defect reduction improves performance in the radiative limit.

14 SOLAR ENERGY↗

Radiochromic Film Dosimetry and its Applications in Radiotherapy

Radiochromic film can be a fast and inexpensive means for performing accurate quantitative radiation dosimetry. The development of new radiochromic compositions that have greater dose sensitivity and fewer environmental dependencies has led to an ever increasing use of the film in radiotherapy applications. In this report the various physical and dosimetric properties of radiochromic film are presented and the strategies to adequately manage these properties when using radiochromic film for radiotherapy applications are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prospects for X(3872) Detection at P-barANDA

Monte-Carlo simulations for a resonance scan of the charmonium-like state X(3872) at P-barANDA are performed. Final state radiation hadronic background reactions are taken into account. The signal reconstruction uses a realistic pattern recognition (track finder and track fitter) and electron/pion discrimination.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of step geometry in copper oxidation by hyperthermal O{sub 2} molecular beam: Cu(511) vs Cu(410)

Steps are known to be often the active sites for the dissociation of O{sub 2} molecules and the nucleation sites of oxide films since they provide paths for subsurface migration and oxygen incorporation. In order to unravel the effect of their morphology on the oxidation of Cu surfaces, we present here a detailed investigation of the O{sub 2} interaction with Cu(511) and compare it with previous results for Cu(410), a surface exhibiting terraces of similar size and geometry but different step morphology. As for Cu(410) we find, by x-ray photoemission spectroscopy performed with synchrotron radiation, that Cu{sub 2}O formation gradually starts above half a monolayer oxygen coverage and that the ignition of oxidation can be lowered to room temperature by dosing O{sub 2} via a supersonic molecular beam at hyperthermal energy. The oxidation rate for Cu(511) comes out to be lower than for Cu(410) at normal incidence, about the same when the O{sub 2} molecules impinge towards the ascending step rise, but higher when they hit the surface along trajectories even slightly inclined towards the descending step rise. These findings can be rationalized by a collision induced absorption mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron-capture supernovae of super-asymptotic giant branch stars and the Crab supernova 1054

An electron-capture supernova (ECSN) is a core-collapse supernova explosion of a super-asymptotic giant branch (SAGB) star with a main-sequence mass M{sub Ms} ∼ 7 - 9.5M{sub ⊙}. The explosion takes place in accordance with core bounce and subsequent neutrino heating and is a unique example successfully produced by first-principle simulations. This allows us to derive a first self-consistent multicolor light curves of a core-collapse supernova. Adopting the explosion properties derived by the first-principle simulation, i.e., the low explosion energy of 1.5 × 10{sup 50} erg and the small {sup 56}Ni mass of 2.5 × 10{sup −3} M{sub ⊙}, we perform a multigroup radiation hydrodynamics calculation of ECSNe and present multicolor light curves of ECSNe of SAGB stars with various envelope mass and hydrogen abundance. We demonstrate that a shock breakout has peak luminosity of L ∼ 2 × 10{sup 44} erg s{sup −1} and can evaporate circumstellar dust up to R ∼ 10{sup 17} cm for a case of carbon dust, that plateau luminosity and plateau duration of ECSNe are L ∼ 10{sup 42} erg s{sup −1} and {sup t} ∼ 60 - 100 days, respectively, and that a plateau is followed by a tail with a luminosity drop by ∼ 4 mag. The ECSN shows a bright and short plateau that is as bright as typical Type II plateau supernovae, and a faint tail that might be influenced by spin-down luminosity of a newborn pulsar. Furthermore, the theoretical models are compared with ECSN candidates: SN 1054 and SN 2008S. We find that SN 1054 shares the characteristics of the ECSNe. For SN 2008S, we find that its faint plateau requires a ECSN model with a significantly low explosion energy of E ∼ 10{sup 48} erg.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermomechanical response of a semicrystalline polymer in the vicinity of the melting by using microcantilever technology

The melting transition of a model semicrystalline polymer has been detected by the microcantilever deflection as a function of temperature. Deflection measurements were done on arrays of 8-cantilevers spin coated with the semicrystalline polymer: poly (propylene azelate). The melting of the polymer has been corroborated by grazing incidence wide angle x-ray scattering experiments performed with synchrotron radiation over a single cantilever.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High detectivity short-wavelength II-VI quantum cascade detector

We report on the experimental demonstration of a ZnCdSe/ZnCdMgSe-based short-wavelength photovoltaic Quantum Cascade Detector (QCD). The QCD operates in two spectral bands centered around 2.6 μm and 3.6 μm. Calibrated blackbody measurements yield a peak responsivity of 0.1 mA/W or 2400 V/W at 80 K, and a corresponding 300 K background radiation limited infrared performance detectivity (BLIP) of ∼2.5 × 10{sup 10 }cm √Hz/W. Comparison of background illuminated and dark current-voltage measurements demonstrates a BLIP temperature of 200 K. The device differential resistance-area product, decreases from about 10{sup 6} Ω cm{sup 2} at 80 K to about 8000 Ω cm{sup 2} at 300 K, indicative of the ultra-low Johnson noise in the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Annular spherically focused ring transducers for improved single-beam acoustical tweezers

The use of ultrasonic transducers with a central hollow is suggested for improved single-beam acoustical tweezers applications. Within the framework of the Fresnel-Kirchhoff parabolic approximation, a closed-form partial-wave series expansion (PWSE) for the incident velocity potential (or pressure) field is derived for an annular spherically focused ring (asfr) with uniform vibration across its surface in spherical coordinates. The Rayleigh-Sommerfeld diffraction integral and the addition theorems for the Legendre and spherical wave functions are used to obtain the PWSE assuming a weakly focused beam (with a focusing angle α ≤ 20°). The PWSE allows evaluating the incident field from the finite asfr in 3D. Moreover, the obtained solution allows computing efficiently the acoustic scattering and radiation force on a sphere centered on the beam's axis of wave propagation. The analytical solution is valid for wavelengths largely exceeding the radius of the asfr and when the viscosity of the surrounding fluid can be neglected. Numerical predictions for the beam-forming, scattering, and axial time-averaged radiation force are performed with particular emphasis on the asfr thickness, the axial distance separating the sphere from the center of the transducer, the (non-dimensional) size of the transducer, as well as the sphere's elastic properties without restriction to the long- (i.e., Rayleigh) or the short-wavelength (i.e., ray acoustics) regimes. Potential applications of the present solution are in beam-forming design, particle tweezing, and manipulation due to negative forces using ultrasonic asfr transducers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subpicosecond 41.8-nm X-ray laser in the plasma produced by femtosecond laser irradiation of a xenon cluster jet

Model calculations are performed of the radiation gain for the 4d5d (J = 0) - 4d5p (J = 1) transition with a wavelength of 41.8 nm in Pd-like xenon ions in the plasma produced by femtosecond laser irradiation of a xenon cluster jet. Conditions for the excitation of an ultrashort-pulse ({approx}1 ps) X-ray laser are discussed. (lasers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RADIATION TRANSFER OF MODELS OF MASSIVE STAR FORMATION. I. DEPENDENCE ON BASIC CORE PROPERTIES

Radiative transfer calculations of massive star formation are presented. These are based on the Turbulent Core Model of McKee and Tan and self-consistently included a hydrostatic core, an inside-out expansion wave, a zone of free-falling rotating collapse, wide-angle dust-free outflow cavities, an active accretion disk, and a massive protostar. For the first time for such models, an optically thick inner gas disk extends inside the dust destruction front. This is important to conserve the accretion energy naturally and for its shielding effect on the outer region of the disk and envelope. The simulation of radiation transfer is performed with the Monte Carlo code of Whitney, yielding spectral energy distributions (SEDs) for the model series, from the simplest spherical model to the fiducial one, with the above components each added step by step. Images are also presented in different wavebands of various telescope cameras, including Spitzer IRAC and MIPS, SOFIA FORCAST, and Herschel PACS and SPIRE. The existence of the optically thick inner disk produces higher optical wavelength fluxes but reduces near- and mid-IR emission. The presence of outflow cavities, the inclination angle to the line of sight, and the thickness of the disk all affect the SEDs and images significantly. For the high-mass surface density cores considered here, the mid-IR emission can be dominated by the outflow cavity walls, as has been suggested by De Buizer. The effect of varying the pressure of the environment bounding the surface of the massive core is also studied. With lower surface pressures, the core is larger, has lower extinction and accretion rates, and the observed mid-IR flux from the disk can then be relatively high even though the accretion luminosity is lower. In this case the silicate absorption feature becomes prominent, in contrast to higher density cores forming under higher pressures.

79 ASTRONOMY AND ASTROPHYSICS↗