Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rate capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

The CMS Outer Tracker for the High Luminosity LHC

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000 - 4000 fb -1 in its lifetime with peak instantaneous luminosities reaching about 5 - 7.5×10 34 cm -2 s -1 . During the Long Shutdown 3 period, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC, including the replacement of the entire silicon tracker. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Another key feature of the OT will be to provide tracking information to the Level-1 trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules that have two closely spaced sensors read out by the same electronics, which can correlate hits in the two sensors creating short track segments called ”stubs”. The stubs will be used for tracking at 40 MHz. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and highlights of research and development activities are reported.

Ravera, Fabio↗

Powering CEBAF's Extraction Cavities At 12 GeV

CEBAF (Continuous Electron Beam Accelerator Facility) at Jefferson Lab was initially designed to deliver up to a 4 GeV electron beam simultaneously to three experimental halls. The maximum deliverable energy was raised to 6 GeV and CEBAF ran there until May of 2012 after which CEBAF entered an upgrade shutdown. After the upgrade, scientists plan to use CEBAF to deliver 11 GeV beam to the three original experimental halls and 12 GeV to new hall ? Hall D. Delivering beams to multiple halls at the new energy requires increased RF power to drive the separation cavities and adding a 750 MHz beam repetition rate to deliver beam to all halls simultaneously. Doubling the beam energy means doubling field strength in the cavities by quadrupling delivered power. 750 MHz beam repetition rate requires new 750 MHz capable cavities and a frequency change to one of the existing IOT amplifiers powering these cavities, and new 499 MHz Solid State Amplifiers to power four downstream cavities. Topics covered will include: verifying the Cavity?s power capabilities, modifications to the 750 MHz system and new cavities, and the decision process in selecting an amplifier type to power four downstream cavities.

Wissmann, Mark↗

Investigating Low Temperature Properties of Rubber Seals - 13020

To achieve the required tightness levels of containers for low and intermediate level radioactive wastes rubbers are widely applied as main sealing materials. The save encapsulation of the radioactive container contents has to be guaranteed according to legislation and appropriate guidelines for long storage periods as well as down to temperatures of -40 deg. C during transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is of high importance. It is known that the material properties of rubbers are strongly influenced by temperature. At low temperatures this is caused by the rubber-glass transition (abbr. glass transition). During continuous cooling the material changes from rubber-like entropy-elastic to stiff energy-elastic behaviour, that allows nearly no strain or retraction. Therefore, rubbers are normally used above their glass transition but the minimum working temperature limit is not defined precisely, what can cause problems during application. The temperature range where full functionality is possible is strongly dependent on the application conditions and the material. For this investigation mainly ethylene propylene diene (EPDM) and fluorocarbon rubbers (FKM) were selected as they are often used for radioactive waste containers. Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) are typically used for the determination of the temperature range of the glass transition process. The standardized compression set measurement according to ISO 815 is common for investigation of rubber sealing materials as the test simulates the seal behaviour after release. To reduce the test time of the standard tests a faster technique giving the same information was developed. Additionally, the breakdown temperature of the sealing function of complete O-ring seals is measured in a component test setup to compare it with the results of the other tests. The experimental setup is capable of measuring the leakage rate at low temperatures by the pressure rise method. A model was developed that allows calculating the minimum working temperature limit of a seal by combining the results of the applied methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerating Application Bulk Synchronous Writes in HPC Environments

High-bandwidth storage tiers are becoming more common for their capability to absorb high-rate, bursty I/Os. Notably, the designs of these fast storage tiers differ from system to system. The variation of these layers and non-uniform methods of access can pose chal- lenges for applications seeking to run at multiple HPC facilities. Therefore, in this work, we present Spectral, a rapid-output ab- straction library to accelerate application, bulk-synchronous writes on HPC systems. We design Spectral to enable applications to use high-bandwidth storage, such as node-local storage and dis- tributed, write-caches (e.g., burst buffers) transparently without requiring modifications to the application or file system source code. The key idea is to allow applications to spend most of the time performing productive work and to not require any source code changes for maximum portability on different HPC archi- tectures. Spectral internally re-routes write-only files through available, high-performance I/O resources before ultimately mi- grating them to the shared global parallel file system. For instance, on Summit, Spectral transparently places application outputs on node-local storage and then utilizes asynchronous migration to the center-wide GPFS file system. We evaluate Spectral on the Summit HPC system (1024 nodes) using the IOR benchmark and real scientific applications. Spectral shows linear performance scaling, improving application write performance by over an order of magnitude when compared to GPFS.

Khan, Awais↗

p-Carbon CNI polarimetry in the AGS and RHIC.

Proton polarization measurements in the AGS (Alternate Gradient Synchrotron) and RHIC (Relativistic Heavy Ion Collider) are based on proton-carbon(pC) and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. The CNI polarimeters are the essential tools for polarized proton acceleration setup and operation. High intensity recoil nuclei from the scattering of the circulating proton beam in the thin carbon target is efficiently utilized in the silicon strip detectors and data acquisition system, which is capable to analyze the event rate up to a few millions/second. This makes it possible for the fast, practically non-destructive polarization measurements. The polarization measurement on the beam energy ramp was implemented in AGS and RHIC, providing locations of polarization losses. Polarimeter operation in the scanning mode also gives polarization profile and beam profile (including bunch by bunch values for the later one). This paper summarizes the recent modifications. Results of polarization measurements are also discussed.

43 PARTICLE ACCELERATORS↗

Impact of the Number of Applied Current Meter Sensors on the Accuracy of Flow Rate Measurements across a Range of Hydroelectric Facilities Indicative of the Domestic Hydroelectric Fleet

The following paper represents the results of an investigation into the impact of the number and placement of Current Meter (CM) flow sensors on the accuracy to which they are capable of predicting the overall flow rate. Flow measurement accuracy is of particular importance in multiunit plants because it plays a pivotal role in determining the operational efficiency characteristics of each unit, allowing the operator to select the unit (or combination of units) which most efficiently meet demand. Several case studies have demonstrated that optimization of unit dispatch has the potential to increase plant efficiencies from between 1 to 4.4 percent [2] [3]. Unfortunately current industry standards do not have an established methodology to measure the flow rate through hydropower units with short converging intakes (SCI); the only direction provided is that CM sensors should be used. The most common application of CM is horizontally, along a trolley which is incrementally lowered across a measurement cross section. As such, the measurement resolution is defined horizontally and vertically by the number of CM and the number of measurement increments respectively. There has not been any published research on the role of resolution in either direction on the accuracy of flow measurement. The work below investigates the effectiveness of flow measurement in a SCI by performing a case study in which point velocity measurements were extracted from a physical plant and then used to calculate a series of reference flow distributions. These distributions were then used to perform sensitivity studies on the relation between the number of CM and the accuracy to which the flow rate was predicted. The following research uncovered that a minimum of 795 plants contain SCI, a quantity which represents roughly 12% of total domestic hydropower capacity. In regards to measurement accuracy, it was determined that accuracy ceases to increase considerably due to strict increases in vertical resolution beyond the application of 49 transects. Moreover the research uncovered that the application of 5 CM (when applied at 49 vertical transects) resulted in an average accuracy of 95.6% and the application of additional sensors resulted in a linear increase in accuracy up to 17 CM which had an average accuracy of 98.5%. Beyond 17 CM incremental increases in accuracy due to the addition of CM was found decrease exponentially. Future work that will be performed in this area will investigate the use of computational fluid dynamics to acquire a broader range of flow fields within SCI.

Flow Measurement↗

GPU acceleration of Swendsen–Wang dynamics

When simulating a lattice system near its critical temperature, local algorithms for modeling the system’s evolution can introduce very large autocorrelation times into sampled data. Here, this critical slowing down places restrictions on the analysis that can be completed in a timely manner of the behavior of systems around the critical point. Because it is often desirable to study such systems around this point, a new algorithm must be introduced. Therefore, we turn to cluster algorithms, such as the Swendsen–Wang algorithm and the Wolff clustering algorithm. They incorporate global updates which generate new lattice configurations with little correlation to previous states, even near the critical point. We look to accelerate the rate at which these algorithm are capable of running by implementing and benchmarking a parallel implementation of each algorithm designed to run on GPUs under NVIDIA’s CUDA framework. A 17 and 90 fold increase in the computational rate was, respectively, experienced when measured against the equivalent algorithm implemented in serial code.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

EVALUATING THE USE OF ULTRASONIC TESTING IN LIEU OF RADIOGRAPHY FOR INSPECTING WELDS IN NUCLEAR POWER PLANTS

The nuclear power industry has recently proposed using ultrasonic testing (UT) in lieu of radiographic testing (RT) on new construction welds and on the repairs of operating reactor component welds. Advantages of UT include a reduction in inspection time, costs, and plant personnel exposure to radiation fields. The replacement of one nondestructive testing method with another, however, requires a detailed analysis of the capabilities of the replacement method as compared to the existing method. Capabilities of interest in this context include detection reliability, false call rates, flaw characterization and sizing accuracy, human factors, data recording capabilities, and cost. The interchangeability of UT and RT has been studied by several institutions, but the evidence found to date in a literature search is not conclusive and therefore requires further investigation to assess the ability of UT to meet nuclear power industry fabrication and pre-service inspection standards. This paper reviews relevant literature on the interchangeability of UT and RT, and identifies potential gaps that may need to be addressed in this area.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Experimental and Modeling Investigation on High-Rate Formability of Aluminum

This work describes the integrated experimental and modeling effort at PNNL to enhance the room-temperature formability of aluminum alloys by taking advantage of formability improvements generally associated with high-strain-rate forming. Al alloy AA5182-O sheets were deformed in near plane-strain conditions at strain-rates exceeding 1000 /s using the electrohydraulic forming (EHF) technique, and at quasi-static strain-rates via a bulge test. A novel capability, combining high-speed imaging with digital image correlation technique, was developed to quantify the deformation history during high-rate forming. Sheet deformation under high rates was modeled in Abaqus and validated with experimentally determined deformation data. The experimental results show a ~2.5x increase in formability at high rates, relative to quasi-static rates, under a proportional loading path that was verified by the experimental data. The model shows good correlation with the experimentally determined strain path. It is anticipated that such integrated experimental and modeling work will enable room-temperature forming of Al and industrial implementation of high-rate forming processes.

Rohatgi, Aashish↗

A high repetition rate millimeter wavelength accelerator for an X-ray free-electron laser

A compact collinear wakefield accelerator has been designed for an X-ray free-electron laser capable of operating at a pulse repetition rate in the tens of kilohertz. The maximum achievable accelerating gradient has been determined, with its limitation linked to beam breakup instability. The fabrication techniques for the principal components of the accelerator including wakefield generation, couplers for excess power extraction and diagnostics, focusing quadrupoles, and a novel undulator have been discussed. Results from various laboratory and beam-based tests on these components have been compared to their original design specifications and demonstrated very good agreement. A preliminary design for the XFEL has been presented, featuring a novel small-period, force-neutral, adjustable-phase undulator.

26 undulator↗

Assessment of Tools for Molten Salt Reactor Dose Rate Calculations

This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CHRONIC IRRADIATION OF SCOTS PINE TREES (PINUS SYLVESTRIS) IN THE CHERNOBYL EXCLUSION ZONE: DOSIMETRY AND RADIOBIOLOGICAL EFFECTS

To identify effects of chronic internal and external radiation exposure for components of terrestrial ecosystems, a comprehensive study of Scots pine trees in the Chernobyl Exclusion Zone was performed. The experimental plan included over 1,100 young trees (up to 20 years old) selected from areas with varying levels of radioactive contamination. These pine trees were planted after the 1986 Chernobyl Nuclear Power Plant accident mainly to prevent radionuclide resuspension and soil erosion. For each tree, the major morphological parameters and radioactive contamination values were identified. Cytological analyses were performed for selected trees representing all dose rate ranges. A specially developed dosimetric model capable of taking into account radiation from the incorporated radionuclides in the trees was developed for the apical meristem. The calculated dose rates for the trees in the study varied within three orders of magnitude, from close to background values in the control area (about 5 mGy y{sup -1}) to approximately 7 Gy y{sup -1} in the Red Forest area located in the immediate vicinity of the Chernobyl Nuclear Power Plant site. Dose rate/effect relationships for morphological changes and cytogenetic defects were identified and correlations for radiation effects occurring on the morphological and cellular level were established.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of Reservoir Heterogeneity on Geothermal Fluid and Methane Recovery from a Geopressured Geothermal Reservoir (Presentation)

Geopressured geothermal reservoirs are characterized by high temperatures and high pressures with correspondingly large quantities of dissolved methane. Two methods utilizing reservoir simulation techniques have been used to estimate recoverability factors of geothermal brine and methane based on well log data from a specific reservoir in Texas. The first assumes a simplified reservoir that hasthree layers: upper shale, sandstone, and lower shale with the sandstone layer thickness equal to the net sandstone in the reservoir interval. The second method uses a detailed reservoir model that accounts for multiple sandstone and shale layering. This method includes 12 layers of sandstone or shale with the layer depths determined from a well log. These two methods are used to answer thequestion on the sensitivity of the results to the level of detail that is included in the reservoir model. It was found that incorporating multiple thin layers of lower permeability sandstone can noticeably impact the results of the reservoir simulation. The heterogeneous model resulted in greater flow rates of both geothermal brine and total methane. Both models demonstrate that thegeopressured geothermal reservoir is capable of producing hot geothermal fluid at flow rates over a long duration that are sufficient for electricity production from binary power plants. The results indicate that simplified models of geopressured geothermal reservoirs that approximate actual reservoir details can be applied to give a reasonable, albeit conservative, estimate of the recoverableresource over broad areas using generalized data sets.

15 GEOTHERMAL ENERGY↗

Facility to Alleviate Salt Technology Risks (FASTR): Preliminary Design Report with Failure Modes and Effects Analysis

The Facility to Alleviate Salt Technology Risks (FASTR) is a versatile, high-temperature (>600°C) molten chloride salt test facility designed to enable a variety of testing to advance the Generation 3 (Gen 3) Concentrated Solar Power (CSP) molten salt technology. FASTR includes a salt preparation system and a forced flow test loop with a suite of instrumentation. The FASTR loop is capable of 725°C operation, flow rates of 3–7 kg/s, includes heated and cooled sections, and swappable components to enable testing of future vendor-supplied hardware. The salt preparation system supplies large batches (e.g., 200 kg) of clean salt for use in the FASTR forced convection loop. This report summarizes the planned design and capabilities of FASTR. In addition, a failure modes and effects analysis of the system is reported.

42 ENGINEERING↗

Quantitative characterization of arc discharge as vacuum interface

An arc discharge with channel diameters of 3 mm and 6 mm and lengths between 30mm and 60mm was experimentally investigated for its potential to function as plasma window, i.e., interface vacuum regions of different pressures. In this study, electron temperature of the plasma channel measured spectroscopically varied in the range of 7000K to 15000K, increasing with discharge current while decreasing with gas flow rate. The plasma window had a slightly positive I-V characteristics over the whole range of investigated current 30A–70 A. Measurements of pressure separation capability, which were determined by input current, gas flow rate, discharge channel diameter, and length, were well explained by viscosity effect and “thermal-block” effect. The experimental results of global parameters including temperature, gas flow rate, and voltage had a good agreement with the simulation results calculated by an axis-symmetry Fluent-based magneto-hydrodynamic model.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology

Purpose: Microbeam radiation therapy (MRT) is an experimental radiotherapy technique that has shown potent antitumor effects with minimal damage to normal tissue in animal studies. This unique form of radiation is currently only produced in a few large synchrotron accelerator research facilities in the world. To promote widespread translational research on this promising treatment technology we have proposed and are in the initial development stages of a compact MRT system that is based on carbon nanotube field emission x-ray technology. We report on a Monte Carlo based feasibility study of the compact MRT system design. Methods: Monte Carlo calculations were performed using EGSnrc-based codes. The proposed small animal research MRT device design includes carbon nanotube cathodes shaped to match the corresponding MRT collimator apertures, a common reflection anode with filter, and a MRT collimator. Each collimator aperture is sized to deliver a beam width ranging from 30 to 200 {mu}m at 18.6 cm source-to-axis distance. Design parameters studied with Monte Carlo include electron energy, cathode design, anode angle, filtration, and collimator design. Calculations were performed for single and multibeam configurations. Results: Increasing the energy from 100 kVp to 160 kVp increased the photon fluence through the collimator by a factor of 1.7. Both energies produced a largely uniform fluence along the long dimension of the microbeam, with 5% decreases in intensity near the edges. The isocentric dose rate for 160 kVp was calculated to be 700 Gy/min/A in the center of a 3 cm diameter target. Scatter contributions resulting from collimator size were found to produce only small (<7%) changes in the dose rate for field widths greater than 50 {mu}m. Dose vs depth was weakly dependent on filtration material. The peak-to-valley ratio varied from 10 to 100 as the separation between adjacent microbeams varies from 150 to 1000 {mu}m. Conclusions: Monte Carlo simulations demonstrate that the proposed compact MRT system design is capable of delivering a sufficient dose rate and peak-to-valley ratio for small animal MRT studies.

60 APPLIED LIFE SCIENCES↗