Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Event Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

An exciton scattering model for carrier multiplication in semiconductor nanocrystals: Theory

The effect of carrier multiplication (CM) in semiconductor nanocrystals is systematically treated by employing an exciton scattering approach. Using projection operators, we reduce the Coulomb coupled multiexciton dynamics to scattering dynamics in the space spanning both single- and biexciton states. We derive a closed set of equations determining the scattering matrix elements. This allows us to interpret CM dynamics as a series of odd-order interband scattering events. Using the time-dependent density matrix formalism, we provide a rigorous description of the CM dynamics induced by a finite-time pump pulse. Within this approach, both processes of single- and biexciton photogeneration and the consequent population relaxation are treated on the same footing. This approach provides a framework for numerical calculations and for comparisons of the quantum efficiencies associated with each process. For applications, the limit of weak interband Coulomb coupling is considered. Finally, we demonstrate that three previously used theoretical models can be recovered as limiting cases of our exciton scattering model.

36 MATERIALS SCIENCE↗

Enhancing fire emissions inventories for acute health effects studies: integrating high spatial and temporal resolution data

Daily fire progression information is crucial for public health studies that examine the relationship between population-level smoke exposures and subsequent health events. Issues with remote sensing used in fire emissions inventories (FEI) lead to the possibility of missed exposures that impact the results of acute health effects studies. This paper provides a method for improving an FEI dataset with readily available information to create a more robust dataset with daily fire progression. High temporal and spatial resolution burned area information from two FEI products are combined into a single dataset, and a linear regression model fills gaps in daily fire progression. The combined dataset provides up to 71% more PM 2.5 emissions, 69% more burned area, and 367% more fire days per year than using a single source of burned area information. The FEI combination method results in improved FEI information with no gaps in daily fire emissions estimates. The combined dataset provides a functional improvement to FEI data that can be achieved with currently available data.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Diagnosing anomalies of spacecraft for space maintenance and servicing

Very often servicing of satellites is necessary to replace components which are responsible for anomalous behavior of satellite operations due to adverse interactions with the natural space environment. A major difficulty with this diagnosis is that those responsible for diagnosing these anomalies do not have the tools to assess the role of the space environment causing the anomaly. To address this issue, we have under development a new rule-based, expert system for diagnosing spacecraft anomalies. The knowledge base consists of over two-hundred rules and provides links to historical and environmental databases. Environmental causes considered are bulk charging, single event upsets (SEU), surface charging, and total radiation dose. The system's driver translates forward chaining rules into a backward chaining sequence, prompting the user for information pertinent to the causes considered. When the user selects the novice mode, the system automatically gives detailed explanations and descriptions of terms and reasoning as the session progresses, in a sense teaching the user. As such it is an effective tutoring tool. The use of heuristics frees the user from searching through large amounts of irrelevant information and allows the user to input partial information (varying degrees of confidence in an answer) or 'unknown' to any question. The system is available on-line and uses C Language Integrated Production System (CLIPS), an expert shell developed by the NASA Johnson Space Center AI Laboratory in Houston.

Lauriente, Michael↗

An Intelligent computer-aided tutoring system for diagnosing anomalies of spacecraft in operation

A new rule-based, expert system for diagnosing spacecraft anomalies is under development. The knowledge base consists of over two-hundred (200) rules and provides links to historical and environmental databases. Environmental causes considered are bulk charging, single event upsets (SEU), surface charging, and total radiation dose. The system's driver translates forward chaining rules into a backward chaining sequence, prompting the user for information pertinent to the causes considered. When the user selects the novice mode, the system automatically gives detailed explanations and descriptions of terms and reasoning as the session progresses, in a sense teaching the user. As such it is an effective tutoring tool. The use of heuristics frees the user from searching through large amounts of irrelevant information and allows the user to input partial information (varying degrees of confidence in an answer) or 'unknown' to any question. The system is available on-line and uses C Language Integrated Production System (CLIPS), an expert shell developed by the NASA Johnson Space Center AI Laboratory in Houston.

Rolincik, Mark↗

Outcomes and Toxicity for Hypofractionated and Single-Fraction Image-Guided Stereotactic Radiosurgery for Sarcomas Metastasizing to the Spine

Purpose: Conventional radiation treatment (20-40 Gy in 5-20 fractions, 2-5 Gy per fraction) for sarcoma metastatic to the spine provides subtherapeutic doses, resulting in poor durable local control (LC) (50%-77% at 1 year). Hypofractionated (HF) and/or single-fraction (SF) image-guided stereotactic radiosurgery (IG-SRS) may provide a more effective means of managing these lesions. Methods and Materials: Patients with pathologically proven high-grade sarcoma metastatic to the spine treated with HF and SF IG-SRS were included. LC and overall survival (OS) were analyzed by the use of Kaplan-Meier statistics. Univariate and multivariate analyses were performed by the use of Cox regression with competing-risks analysis; all confidence intervals are 95%. Toxicities were assessed according to Common Terminology Criteria for Adverse Events, version 4.0. Results: From May 2005 to November 11, 2012, 88 patients with 120 discrete metastases received HF (3-6 fractions; median dose, 28.5 Gy; n=52, 43.3%) or SF IG-SRS (median dose, 24 Gy; n=68, 56.7%). The median follow-up time was 12.3 months. At 12 months, LC was 87.9% (confidence interval [CI], 81.3%-94.5%), OS was 60.6% (CI, 49.6%-71.6%), and median survival was 16.9 months. SF IG-SRS demonstrated superior LC to HF IG-SRS (12-month LC of 90.8% [CI, 83%-98.6%] vs 84.1% [CI, 72.9%-95.3%] P=.007) and retained significance on multivariate analysis (P=.030, hazard ratio 0.345; CI, 0.132-0.901]. Treatment was well tolerated, with 1% acute grade 3 toxicity, 4.5% chronic grade 3 toxicity, and no grade >3 toxicities. Conclusions: In the largest series of metastatic sarcoma to the spine to date, IG-SRS provides excellent LC in the setting of an aggressive disease with low radiation sensitivity and poor prognosis. Single-fraction IG-SRS is associated with the highest rates of LC with minimal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sphere-Wall Impact Experiments with Piezoelectric Force Sensors

Measurement of impulse imparted to a target from {mu}s-timescale laser ablation events is often performed with piezoelectric force sensors. For pulsed laser ablation with a target resting on the force sensors, an effect can occur for a vertical thrust stand in an exhaust-up configuration that results in measurement of about twice the actual imparted impulse. A CO{sub 2} laser operating at 10.6 {mu}m wavelength, 300 ns pulse length, and up to 20 J pulse energy single shots was used to ablate samples of PCTFE. Force sensor measurements of the imparted impulse were compared to tests with a ballistic pendulum over a variety of fluences. The theoretical impulse delivered by the impacts of 6 mm diameter spheres of aluminum, steel, POM, and PTFE on the force sensor were studied, and the coefficients of restitution were measured for the targets. Practical issues for measurement of ablation-imparted impulse with piezoelectric sensors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Distinct Mechanisms and Hydricities of Cp*Ir-Based CO 2 Hydrogenation Catalysts in Basic Water

Transition metal-catalyzed reversible hydrogenation of CO 2 to formate in aqueous solutions under ambient conditions is an attractive environmentally friendly strategy for the storage and transportation of H 2 in a liquid chemical form. Here, mechanistic details for the CO 2 hydrogenation by a series of pentamethylcyclopentadienyl iridium(III) (Cp*Ir) complexes with picolinamidate ligands are investigated through density functional theory and kinetic isotope effects (KIEs) calculations. Additionally, adopting a speciation approach at a pH of 8.2, CO 2 hydrogenation mechanisms of 37 distinct protonation states and conformers of Cp*Ir type complexes are investigated. This imposes a challenging test for the computational modeling in terms of providing a consistent correlation with experimental kinetics and KIE studies of multiple catalysts instead of a single complex. Overall, H 2 heterolysis to generate an iridium hydride intermediate was demonstrated to be the rate determining step, which proceeds via distinct pathways depending on the stereoelectronic properties of the ligand. A peculiar iridium dihydride route was also uncovered, which could be optimized to accelerate the H 2 heterolysis. We have further computed the thermodynamic and kinetic hydricities of 74 complexes with [Cp*Ir(L)(H)] q ( q = -1, 0, 1 depending on the ligand charge by deprotonation or protonation events) general formula. Hydricity values do not show any noticeable correlation with the thermodynamics (Δ G ) of [Cp*Ir(L)(HCO 2 – )] formation but exhibit linear correlation with the kinetics (Δ G ‡ ) of electrophilic CO 2 attack to iridium hydride species, especially when the charges and local structural effects of the metal hydrides are considered. Insights gained in this study on (i) the factors determining the preferred pathway for the rate-limiting H 2 heterolysis step, (ii) the correlation between thermodynamic hydricity and the kinetics of CO 2 insertion to iridium hydride species, and (iii) mechanistic analysis via combination of free energy profiles and KIE studies for a series of iridium catalysts will provide guidelines for the design of next-generation catalysts for the reversible H 2 storage through CO 2 utilization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experience and Grouping Effects when Handling Non-Normal Situations

Currently, most of the displays in control rooms can be categorized as status, alerts/procedures, or control screens. With the advent and use of CRTs and the associated computing power available to compute and display information, it is now possible to combine these different elements of information and control onto a single display. An experiment was conducted to determine which, if any, of these functions should be collocated in order to better handle simple anticipated non-normal system events. The results indicated that there are performance benefits and subject preferences to combining all the information onto one screen or combining the status and alert/procedure information onto one screen and placing the controls in another area. The results indicated that operators quickly modify their display preferences to the display configuration most recently used.

Trujillo, Anna C.↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A cost assessment of reliability requirements for shuttle-recoverable experiments

The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.

Campbell, J. W.↗

Multiple-Interactions of Displacement Cascades with He-vacancy Clusters in a-Iron: Computer Simulations

Multiple interactions of displacement cascades with He-vacancy clusters are investigated using molecular dynamics simulations. The effects of a single displacement cascade on the stability of a He-vacancy (He-V) cluster depend on the He-to-vacancy (He/V) ratio and the primary knock-on atom (PKA) energy. Initial He-V clusters consist of 10 and 20 vacancies with He/V ratios ranging from 0.2 to 3 and the PKA energy, Ep, varying from 2 keV to 10 keV. The size of He-V clusters was found to generally increase with increasing He/V ratios for the same PKA energy, but the stability of He-V clusters decreases with increasing PKA energy. The results are compared with those for voids impacted by collisional cascades. During multiple 5 keV cascade events, the final size of He-V clusters depends on only the initial He/V ratios. It is of interest to notice that the number of vacancies in a He-V cluster is determined by the first cascade event, while subsequent cascade overlap has a significant effect on its stability. These results are discussed in terms of the internal pressure of He-V clusters, the mobility of He atoms, the number of vacancies produced by cascades and the He/V ratio.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dose-rate effects of protons on in vivo activation of nuclear factor-kappa B and cytokines in mouse bone marrow cells

The objective of this study was to determine the kinetics of nuclear factor-kappa B (NF-{kappa}B) activation and cytokine expression in bone marrow (BM) cells of exposed mice as a function of the dose rate of protons. The cytokines included in this study are pro-inflammatory [i.e., tumor necrosis factor-alpha (TNF-{alpha}), interleukin-1beta (IL-1{beta}), and IL-6] and anti-inflammatory cytokines (i.e., IL-4 and IL-10). We gave male BALB/cJ mice a whole-body exposure to 0 (sham-controls) or 1.0 Gy of 100 MeV protons, delivered at 5 or 10 mGy min{sup -1}, the dose and dose rates found during solar particle events in space. As a reference radiation, groups of mice were exposed to 0 (sham-controls) or 1 Gy of {sup 137}Cs {gamma} rays (10 mGy min{sup -1}). After irradiation, BM cells were collected at 1.5, 3, 24 h, and 1 month for analyses (five mice per treatment group per harvest time). The results indicated that the in vivo time course of effects induced by a single dose of 1 Gy of 100 MeV protons or {sup 137}Cs {gamma} rays, delivered at 10 mGy min{sup -1}, was similar. Although statistically significant levels of NF-{kappa}B activation and pro-inflammatory cytokines in BM cells of exposed mice when compared to those in the corresponding sham controls (Student's t-test, p < 0.05 or < 0.01) were induced by either dose rate, these levels varied over time for each protein. Further, only a dose rate of 5 mGy min{sup -1} induced significant levels of anti-inflammatory cytokines. The results indicate dose-rate effects of protons.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Spot Scanning Proton Therapy for Malignancies of the Base of Skull: Treatment Planning, Acute Toxicities, and Preliminary Clinical Outcomes

Purpose: To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. Methods and Materials: From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. Results: Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. Conclusions: In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First results of the KM3NeT multi-PMT DOM

The future KM3NeT neutrino telescope will consist of several thousand digital optical modules (DOMs), each of which will be equipped with 31 3-inch photo-multiplier tubes (PMTs). This design has various advantages over the use of one large PMT per optical module, e.g. concerning effective photocathode area per module, improved background suppression and directional reconstruction. Currently, the KM3NeT collaboration is testing a prototype DOM deployed on the instrumentation line of the ANTARES neutrino telescope. The DOM has been operational since mid-April 2013. First data are presented and compared to simulation results. The results are very encouraging and indicate that muon identification and a coarse direction estimation are possible event with a single DOM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerically exact full counting statistics of the nonequilibrium Anderson impurity model

The time-dependent full counting statistics of charge transport through an interacting quantum junction is evaluated from its generating function, controllably computed with the inchworm Monte Carlo method. Exact noninteracting results are reproduced; then, we continue to explore the effect of electron-electron interactions on the time-dependent charge cumulants, first-passage time distributions, and n-electron transfer distributions. We observe a crossover in the noise from Coulomb blockade to Kondo-dominated physics as the temperature is decreased. In addition, we uncover long-tailed spin distributions in the Kondo regime and analyze queuing behavior caused by correlations between single-electron transfer events

36 MATERIALS SCIENCE↗