Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Reconstruction of neutrino induced NC-1π{sup 0} using the T2K-ND280 tracker

Single π{sup 0} production is the one of the most important backgrounds in the υ{sub e} appearance measurement in T2K. Large uncertainties in this production make it difficult to predict. Measurement at the near detector (ND280) is required both to constrain the background prediction at the far detector (Super-K) and also at the near detector to improve knowledge of beam υ{sub e} contamination. We present an analysis based on Monte Carlo simulation of neutral current (NC) single π{sup 0} in the tracker region. NC-1π{sup 0} events are selected using a specific two-gamma signature in the tracker region. One decay gamma is reconstructed by selecting an e+/e− pair starting in the Fine-Grained target Detector (FGD) and extending into the TPC, where the leptons can be identified and their momentum measured accurately. The second gamma is then selected in-time in the Calorimeter modules surrounding the tracker. Selections cuts, efficiency and purity of the selection are presented and projection of the expected number of single π{sup 0} candidates for 3 × 10{sup 20} protons on target (PoT) exposure is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Benchmarks for Self-Driving Labs using Color Matching

Self Driving Labs (SDLs) that combine automation of experimental procedures with autonomous decision making are gaining popularity as a means of increasing the throughput of scientific workflows. The task of identifying quantities of supplied colored pigments that match a target color, the color matching problem, provides a simple and flexible SDL test case, as it requires experiment proposal, sample creation, and sample analysis, three common components in autonomous discovery applications. We present a robotic solution to the color matching problem that allows for fully autonomous execution of a color matching protocol. Our solution leverages the WEI science factory platform to enable portability across different robotic hardware, the use of alternative optimization methods for continuous refinement, and automated publication of results for experiment tracking and post-hoc analysis.

Artificial intelligence↗

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: A simulation study based on intrafractional motion in the prone position

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3 mm received a dose of 94.5 Gy, whereas the remainder of the prostate + 7 mm received a dose of 75.6 Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4 mm (− 3.1 to 8.2 mm), − 2.2 mm (− 9.1 to 1.5 mm), and − 0.3 mm (− 5.0 to 1.8 mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V{sub 90%} of the IPL and V{sub 100%} of the prostate between the simulated plan and original plan were − 3.9% to − 0.3% and − 0.6% to 1.1% for respiration-induced motion and 3.1% to − 67.8% and 3.6% to − 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.

61 RADIATION PROTECTION AND DOSIMETRY↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Dots Reveal Shifts in Organic Nitrogen Uptake by Fungi Exposed to Long-Term Nitrogen Enrichment

Anthropogenic nitrogen (N) enrichment can alter N dynamics associated with decomposing plant litter. However, it is unclear to what extent these alterations occur via microbial effects (e.g., changes in gene regulation, physiology, or community composition) versus plant litter effects (e.g., changes in composition of N and C compounds). To isolate microbial effects from plant litter effects, we collected plant litter from long-term N fertilized and control plots, reciprocally inoculated it with microbes from the two treatments, and incubated it in a common field setting for three months. We used quantum dots (QDs) to track fungal uptake of glycine and chitosan. Glycine is a relatively simple organic N compound; chitosan is more complex. We found that microbial and litter origins each contributed to a shift in fungal uptake capacities under N fertilization. Specifically, N fungi preferred glycine over chitosan, but control fungi did not. In comparison, litter effects were more subtle, and manifested as a three-way interaction between litter origin, microbial origin, and type of organic N (glycine versus chitosan). In particular, control fungi tended to target chitosan only when incubated with control litter, while N fungi targeted glycine regardless of litter type. Overall, microbial effects may mediate how N dynamics respond to anthropogenic N enrichment in ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Narrow Energy Spread Protons and Ions from High-Intensity, High-Contrast Laser Solid Target Interactions

Recent simulations show that an idealized, high intensity, short pulse laser can generate quasi-monoenergetic proton beams with energies over 100 MeV in an interaction with a thin film. However, most short pulse laser facilities with sufficient intensity have difficulty controlling the nanosecond and picosecond contrast necessary to realize such a regime. Experiments were performed to investigate proton and ion acceleration from a high contrast, short pulse laser by employing dual plasma mirrors along with a deformable mirror at the HERCULES laser facility at the Center for Ultrafast Optical Sciences, University of Michigan. Plasma mirrors were characterized, allowing a 50% throughput with an intensity contrast increase of 105. The focal spot quality was also exceptional, showing a 1.1 micron full width at half maximum (FWHM) focal diameter. Experiments were done using temporally cleaned 30 TW, 32 fs pulses to achieve an intensity of up to 10{sup 21} Wcm{sup -2} on Si{sub 3}N{sub 4} and Mylar targets with thicknesses ranging 50 nm to 13 microns. Proton beams with energy spreads below 2 MeV were observed from all thicknesses, peaking with energies up to 10.3 MeV and an energy spread of 0.8 MeV. Similar narrow energy spreads were observed for oxygen, nitrogen, and carbon at the silicon nitride thickness of 50 nm with energies up to 24 MeV with an energy spread of 3 MeV, whereas the energy spread is greatly increased at a larger thickness. Maximum energies were confirmed with CR39 track detectors, while a Thomson ion spectrometer was used to gauge the monoenergetic nature of the beam.

43 PARTICLE ACCELERATORS↗

Photoelectron–residual-ion interaction in angle-resolved streaked shake-up ionization of helium

Streaked photoelectron emission spectra access the correlated dynamics of photoelectrons and residual target electrons with attosecond temporal resolution. Here, we calculated ab initio single-ionization spectra for photoemission from helium atoms by colinearly polarized ultrashort XUV and assisting few-femtosecond IR pulses. Distinguishing direct and shake-up ionization resulting in ground-state and excited (𝑛 = 2, 3) He + residual ions, respectively, we examined the effects of the correlated photoemission dynamics on the photoelectron phase accumulation as a function of the observable photoelectron detection direction and kinetic energy and XUV–IR pulse delay. We tracked the dynamical evolution of the residual ion in relative streaked photo- emission delays and found dominant contributions for shake-up emission from the residual-ion–photoelectron interaction. These are in very good and fair agreement, respectively, for 𝑛 = 2 and 𝑛 = 3 shake-up photoemission along the pulse-polarization directions, with previous experimental and theoretical investigations [Ossiander et al ., Nat. Phys. 13, 280 (2017)] and reveal a strong photoemission-direction dependence for shake-up ionization due to the coupling between the photoelectron and evolving residual-ion charge distribution in the IR-laser field.

Stark effect↗

SU-E-J-206: A Comparison of Different Hardware Design Approaches for Feature-Supported Optical Head-Tracking with Respect to Angular Dependencies

Purpose: Recent research has shown that optical features significantly improve marker-less optical head-tracking for cranial radiotherapy. Simulations, however, showed that these optical features, which are used to derive tissue thickness, depend on the incident angle of the IR scanning laser beam and the perspective of the camera analyzing the reflective patterns. We present an experimental analysis determining which is the most robust optical setup concerning angular influences. Methods: In three consecutive experiments, the incident angle of the laser (1), the perspective of the camera (2) or both simultaneously (3, ‘inBeam’-perspective) were changed with respect to the target. We analyzed how this affects feature intensity. These intensities were determined from seven concentric regions of interest (ROIs) around the laser spot. Two targets were used: a tissue-like silicone phantom and a human's forehead. Results: For each experiment, the feature intensity generally decreases with increasing angle. We found that the optical properties of the silicone phantom do not fit the properties of human skin. Furthermore, the angular influence of the laser on the features is significantly higher than the perspective of the camera. With the ‘inBeam’- perspective, the smoothest decays of feature intensity were found. We suppose that this is because of a fixed relationship between both devices. This smoothness, suggesting a predictable functional relationship, may simplify angle compensation for machine learning algorithms. This is particularly prominent for the medial ROIs. The inner ROIs highly depend on the angle and power of the laser. The outer ROIs show less angular dependency but the signal strength is critically low and prone to artifacts. Therefore and because of the smooth decays, medial ROIs are a suitable tradeoff between susceptibility, signal-noise-ratio and distance to the center of the laser spot. Conclusion: For tissue thickness correlated feature acquisition, the medial ROIs with the ‘inBeam’-setup provide most valuable features This work was supported by Varian Medical Systems Inc. (Palo Alto, CA, USA). In addition, this work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient mutagenesis and genotyping of maize inbreds using biolistics, multiplex CRISPR/Cas9 editing, and Indel-Selective PCR

CRISPR/Cas9 based genome editing has advanced our understanding of a myriad of important biological phenomena. Important challenges to multiplex genome editing in maize include assembly of large complex DNA constructs, few genotypes with efficient transformation systems, and costly/labor-intensive genotyping methods. Here we present an approach for multiplex CRISPR/Cas9 genome editing system that delivers a single compact DNA construct via biolistics to Type I embryogenic calli, followed by a novel efficient genotyping assay to identify desirable editing outcomes. We first demonstrate the creation of heritable mutations at multiple target sites within the same gene. Next, we successfully created individual and stacked mutations for multiple members of a gene family. Genome sequencing found off-target mutations are rare. Multiplex genome editing was achieved for both the highly transformable inbred line H99 and Illinois Low Protein1 (ILP1), a genotype where transformation has not previously been reported. In addition to screening transformation events for deletion alleles by PCR, we also designed PCR assays that selectively amplify deletion or insertion of a single nucleotide, the most common outcome from DNA repair of CRISPR/Cas9 breaks by non-homologous end-joining. The Indel-Selective PCR (IS-PCR) method enabled rapid tracking of multiple edited alleles in progeny populations. The ‘end to end’ pipeline presented here for multiplexed CRISPR/Cas9 mutagenesis can be applied to accelerate maize functional genomics in a broader diversity of genetic backgrounds.

59 BASIC BIOLOGICAL SCIENCES↗

Data for "Efficient Mutagenesis and Genotyping of Maize Inbreds Using Biolistics, Multiplex CRISPR/Cas9 Editing, and Indel-Selective PCR"

CRISPR/Cas9 based genome editing has advanced our understanding of a myriad of important biological phenomena. Important challenges to multiplex genome editing in maize include assembly of large complex DNA constructs, few genotypes with efficient transformation systems, and costly/labor-intensive genotyping methods. Here we present an approach for multiplex CRISPR/Cas9 genome editing system that delivers a single compact DNA construct via biolistics to Type I embryogenic calli, followed by a novel efficient genotyping assay to identify desirable editing outcomes. We first demonstrate the creation of heritable mutations at multiple target sites within the same gene. Next, we successfully created individual and stacked mutations for multiple members of a gene family. Genome sequencing found off-target mutations are rare. Multiplex genome editing was achieved for both the highly transformable inbred line H99 and Illinois Low Protein1 (ILP1), a genotype where transformation has not previously been reported. In addition to screening transformation events for deletion alleles by PCR, we also designed PCR assays that selectively amplify deletion or insertion of a single nucleotide, the most common outcome from DNA repair of CRISPR/Cas9 breaks by non-homologous end-joining. The Indel-Selective PCR (IS-PCR) method enabled rapid tracking of multiple edited alleles in progeny populations. The ‘end to end’ pipeline presented here for multiplexed CRISPR/Cas9 mutagenesis can be applied to accelerate maize functional genomics in a broader diversity of genetic backgrounds.

gene editing↗

Examining Aerosol Vertical Transport and Removal during Deep Convective Events

Atmospheric aerosols affect the global energy budget by scattering and absorbing sunlight (direct effects) and by changing the microphysical structure, lifetime, and coverage of clouds (indirect effects). Globally, the free troposphere is a major source of nucleation- and Aitken-mode aerosols due to the enhanced new particle formation rates at high altitudes. Recent studies have shown deep convective systems are capable of transporting these small aerosols from the free troposphere to the boundary layer by strong convective downdrafts and weaker downward motions in the stratiform regions. These vertically transported aerosols can grow into cloud condensation nuclei (CCN) and play a significant role in the global climate. During the deep convective processes, existing accumulation-mode aerosols that act as coagulation sinks of smaller particles are also removed by wet scavenging. Compared to the vertical transport of these particles by entrainment mixing, which is slower but more prevalent, the deep convective downdraft processes may be more rapid and efficient in the vertical transport of aerosols. However, most of the current climate models do not include this mechanism as a source of CCN, mainly because the frequency of deep convective events varies significantly with geographic location and thus their contributions to CCN are unpredictable. We target this critical gap in understanding the vertical transport and removal of aerosols by deep convections. We proposed to analyze a multi-year, multi-site measurement record available from the U.S. Department of Energy (DOE) ARM program, including the observations from the 2014/15 Observations and Modeling of the Green Ocean Amazon (GoAmazon) field campaign, the 2017/18 Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign, the 2018/19 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign, the 2021/22 Tracking Aerosol Convection Interactions Experiment (TRACER) field campaign, and the long-term measurements collected at the Southern Great Plains (SGP) atmospheric observatory, where deep convective clouds were frequently observed. This project is aimed at the following three objectives: (1) Gaining a detailed and quantitative understanding of the aerosols transported by a convective downdraft and their evolution in the atmosphere; (2) Examining the wet scavenging mechanisms and efficiencies of aerosols at altitudes of deep convective systems based on ground and aircraft measurements; (3) Evaluating the contribution of deep convective systems to CCN as both a source and a sink of atmospheric aerosols and its seasonal variabilities.

54 ENVIRONMENTAL SCIENCES↗

Surface Analytics in Support of the Development of Static AutoClean - an In-Situ Cleaning Process for Ion Implanters

Static AutoClean is a new in-situ cleaning strategy in development at ATMI registered that enables increased process efficiency and safety in the ion implantation process. Like the Dynamic in-situ AutoClean technology previously introduced and released by ATMI, Static AutoClean utilizes XeF{sub 2} chemistry for in-situ cleaning of hazardous contaminants and deposits. Static AutoClean, however, is targeted towards cleaning areas of the beam-line (like electrode insulators or source bushings) where cleaning efforts using Dynamic AutoClean may not be sufficient. An explanation of this cleaning strategy and results showing its effectiveness will be presented in a separate paper at this conference (S. Yedave et al.). This paper presents the surface analytical data and methods used to understand and evaluate the effectiveness of Static AutoClean in removing contaminants from surfaces within the source vacuum chamber. Energy Dispersive Spectroscopy (EDS) was used to track the magnitude and spatial distribution of contaminants present on the surfaces within various regions in the source chamber space of an implanter following ion source operation with a commonly used dopant gas. After in-situ cleaning, these same components and surfaces were re-evaluated by EDS to quantitatively determine the reduction in surface contaminants present within the chamber. Learnings regarding the distribution of implant process contamination within the source chamber as well as Static AutoClean's effectiveness in removing it will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

SU-C-210-02: Impact of Intrafractional Motion On TomoTherapy Stereotactic Body Radiotherapy (SBRT) 4D Dosimetry

Purpose: TomoTherapy treatment has unique challenges in handling intrafractional motion compared to conventional LINAC. This study is aimed to gain a realistic and quantitative understanding of motion impact on TomoTherapy SBRT treatment of lung and prostate cancer patients. Methods: A 4D dose engine utilizing GPUs and including motion during treatment was developed for the efficient simulation of TomoTherapy delivered dosimetry. Two clinical CyberKnife lung cases with respiratory motion tracking and two prostate cases with a slower non-periodical organ motion treated by LINAC plus Calypso tracking were used in the study. For each disease site, one selected case has an average motion (6mm); the other has a large motion (10mm for lung and 15mm for prostate). SBRT of lung and prostate cases were re-planned on TomoTherapy with 12 Gyx4 fractions and 7Gyx5 fractions, respectively, all with 95% PTV coverage. Each case was planned with 4 jaw settings: 1) conventional 1cm static, 2) 2.5cm static, 3) 2.5cm dynamic, and 4) 5cm dynamic. The intrafractional rigid motion of the target was applied in the dose calculation of individual fractions of each plan and total dose was accumulated from multiple fractions. Results: For 1cm static jaw plans with motions applied, PTV coverage is related to motion type and amplitude. For SBRT patients with average motion (6mm), the PTV coverage remains > 95% for lung case and 74% for prostate case. For cases with large motion, PTV coverage drops to 61% for lung SBRT and 49% for prostate SBRT. Plans with other jaws improve uniformity of moving target, but still suffer from poor PTV coverage (< 70%). Conclusion: TomoTherapy lung SBRT is less motion-impacted when average amplitude of respiratory-induced intrafractional motion is present (6mm). When motion is large and/or non-periodic (prostate), all studied plans lead to significantly decreased target coverage in actual delivered dosimetry.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-07: Preliminary Experimental Comparison of Spot- and Continuous Line Scanning with Or Without Rescanning for Gated Proton Therapy

Purpose: We aim to compare the performance of discrete spot- or continuous line scanning combined with rescanning in mitigating residual organ motion during gated proton therapy treatments. Methods: The Quasar respiratory phantom was used to move a 2D scintillation detector on a linear trajectory with sinusoidal motion pattern (sin{sup 4}), 20 mm peak-to-peak amplitude and 5 sec period. Its motion was monitored using a customized solution based on optical tracking technology. We compared spot and line scanning plans for a monoenergetic 150 MeV circular field, 50.4 mm radius at isocenter. Transverse dose distributions at 13 cm depth in PMMA (15.47 mm water equivalent) were measured to compare three options for motion mitigation: rescanning (10× factor), gating and their combination. The gating window was centered in the trajectory plateau to simulate end-exhale gated treatment in presence of 2 mm and 4 mm residual motion, parallel or perpendicular to the primary scanning direction. Results: When the target moves perpendicular to the primary scanning direction, large dose deviations are measured (γ3%/3mm=47%) without mitigation techniques. Beam gating combined with rescanning restores target coverage (γ3%/3mm=91%). For parallel target motion, observed dose distortions in the non-compensated irradiation are smaller (γ3%/3mm=77%). Beam gating alone recovers the 100% gamma pass-rate at 3%/3mm. Continuous line scanning reduces delivery time by up to 60% with respect to discrete spot scanning in presence of motion mitigation, and improves homogeneity when rescanning is applied (up to 20%, perpendicular motion, 4 mm residual motion). Conclusion: The direction of motion has a large impact on the target dose coverage. Nevertheless, even in the worst case scenario, gating combined with rescanning could mitigate the impact of motion on dose deposition. Moreover, continuous line rescanning improves the robustness against residual motion in the gating window. This study has received funding from the European Community’s Seventh Framework Programme (FP7/2007–2013) under grant agreement n.290605 (PSI-FELLOW/COFUND) and ‘Giuliana and Giorgio Stefanini Foundation’.

60 APPLIED LIFE SCIENCES↗

Tracking down the links between charged particles and biological response: A UK perspective

The UK has a long history of radiobiology research into charged particles, with interest likely to expand in the coming years following the recent government announcement of Pound-Sign 250 million to build two proton beam therapy facilities in the UK. A brief overview of research and facilities past and present with respect to radiation protection and oncology along with biological consequences and underlying mechanisms will be presented and discussed. Increased knowledge of the mechanisms underpinning the radiation action on biological systems is important in understanding, not only the risks associated with exposure, but also in optimising radiotherapy treatment of cancer. Ionizing radiation is always in the form of structure tracks which are a unique characteristic of ionizing radiation alone producing damage grossly different and far more biologically effective than endogenous damage. The track structure is the prime determinant of biological response to DNA, with charged particles of increasing LET leading to an increase in the frequency and complexity of clustered DNA damage. High-LET particles will also produce non-homogeneous dose distribution through a cell nucleus resulting in correlated DNA breaks along the path of the particle and an increase in the probability of complex chromosomal rearrangements. However it is now well established that there is variety of phenomena that do not conform to the conventional paradigm of targeted radiobiology, but there is insufficient evidence to assess the implications of these non-targeted effects for radiotherapy or relevance to risk for human health.

62 RADIOLOGY AND NUCLEAR MEDICINE↗