Search NASASearch

SEARCH · Search NASA

Results for “US ORGANIZATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,741 records · Page 63

Quantum control of Hubbard excitons

Quantum control of the many-body wavefunction is a central challenge in quantum materials research, as it could yield a precise control knob to manipulate emergent phenomena. Floquet engineering, the coherent dressing of quantum states with periodic non-resonant optical fields, has become an important strategy for quantum control. Most applications to solid-state systems have targeted weakly interacting or single-ion states, leaving the manipulation of many-body wavefunctions largely unexplored. Here, in this work, we use Floquet engineering to achieve quantum control of a strongly correlated Hubbard exciton in the one-dimensional Mott insulator Sr 2 CuO 3 . A nonresonant midinfrared optical field coherently dresses the exciton wavefunction, driving its rotation between bright and dark states. We use resonant third-harmonic generation to quantify ultrafast π/2 rotations on the Bloch sphere spanned by these exciton states. Our work advances the quest towards programmable control of correlated states and exciton-based quantum sensing.

36 MATERIALS SCIENCE

Distributed Mafic Rock Resources for Carbon Mineralization in Arizona

Ex-situ carbon mineralization is a process by which CO2 is reacted with alkaline silicate minerals and rocks to produce stable carbonate materials, which can be used for other industrial processes. Arizona, U.S.A., hosts abundant surficial mafic rocks in three young volcanic fields, Geronimo-San Bernardino, San Francisco, and Springerville, and other distributed locations throughout the state. We created a Mafic Rock Resource Inventory (MRRI) that categorizes geochemical, physical, and textural characteristics of a diverse suite of surficial mafic rock samples and provide a benchmark reaction dataset parameterizing the temperature, pressure, and pH conditions best suited ex-situ mineralization in different rock types. MRRI data is publicly available online via a map-viewer. We establish two reaction condition sets, varied in temperature, pressure, and pH, where crystal-rich and glassy rocks reach maximum reaction extent and different carbonate phases are formed. Systematic ex-situ mineralization experiments on 21 diverse rock types show trends in geochemical, mineralogical, and reactivity behavior and establish maximum effective capture capacity. From this, scoria cones in three Arizona volcanic fields have a ~62 Gt effective CO₂ storage capacity with one of the fields having a ~42 Gt storage capacity in lava flows. Reactivity results have applications to alkaline mafic rock resources exposed globally, including producing additional effective storage capacity estimates and scaled commercialization of mafic rock ex-situ mineralization, should reaction extents be improved through advances in mineralization techniques. MRRI data were used to create a Direct Air Capture to Mineralization (DACM) systems model, technoeconomic analysis, and life-cycle assessment. These documents are presented as three appendices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Integration of ultra-low coverage whole-genome sequences for reconstructing the evolutionary history of Galapagos giant tortoises

Genomic data from contemporary and historical samples often need to be coupled for evolutionary reconstructions of multitaxon complexes. However, the genetic data recovered from historical samples may result only in ultra-low coverage whole-genome sequences (ulcWGS; <0.15× depth), leading to inaccurate evolutionary inferences given a preponderance of missing data. Using the Galapagos giant tortoise radiation as a study system (Chelonoidis spp., composed of 13 extant and four extinct lineages), we assembled a novel methodological pipeline that removes potential noise introduced by the missing data and enhances the evolutionary signal from ulcWGS samples. We leveraged existing tools for phylogenomic placement (EPA-ng), population genomic structure (smartsnp) and admixture (Admixfrog, NGSadmix) to demonstrate that the evolutionary history of samples can be uncovered with sequencing depths as low as 0.008–0.139×. Importantly, these approaches do not use genotype imputation of the ulcWGS samples, which would require extensive reference datasets. Our application to two cases of extinct lineages of Galapagos giant tortoises, with and without references from the same lineage, demonstrates the general value of the approach. We confirm where the extinct lineages from San Cristóbal and Santa Fe islands fit into the Galapagos giant tortoise radiation, and that these lineages were evolutionarily distinct entities.

ancient DNA

Sodium-sulfur battery flight experiment definition study

Sodium-sulfur batteries are considered to be one of the most likely battery systems for space applications. Compared with the Ni-H2 or Ni-Co battery systems, Na-S batteries offer a mass reduction by a factor of 2 to 4, representing significant launch cost savings or increased payload mass capabilities. The Na-S battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte; the transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. This paper describes five tests identified for the Na-S battery flight experiment definition study, which include the cell characterization test, the reactant distribution test, the current/temperature distribution test, the freeze/thaw test, and the multicell LEO test. A schematic diagram of Na-S cell is included.

Chang, Rebecca

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Orbital Processing of High-Quality CdTe Compound Semiconductors

CdZnTe crystals were grown in one-g and in micro-g for comparative analysis. The two micro-g crystals were grown in the Crystal Growth Furnace during the First United States Microgravity Laboratory mission (USML-1). The samples were analyzed for chemical homogeneity, structural perfection, and optoelectronic performance (infrared transmission). Fourier Transform Infrared (FTIR) transmission of both ground and flight materials showed that the infrared transmission was close to theoretical, 63% versus 66%, suggesting that the material was close to the stochiometric composition during both the ground and flight experiments. Infrared microscopy confirmed that the principal precipitates were Te and their size (1-10 microns) and density suggested that the primary flight and ground base samples experienced similar cooling rates. Macrosegregation was predicted, using scaling analysis, to be low even in one-g crystals and this was confirmed experimentally, with nearly diffusion controlled growth achieved even in the partial mixing regime on the ground. Radial segregation was monitored in the flight samples and was found to vary with fraction solidified, but was disturbed due to the asymmetric grvitational and thermal fields experienced by the flight samples. The flight samples, however, were found to be much higher in structural perfection than the ground samples produced in the same furnace under identical growth conditions except for the gravitational level. Rocking curve widths were found to be substantially reduced, from 20/35 (one-g) to 9/20 (micro-g) for the best regions of the crystals. The full width at half maximum (FWHM) of 9 arc seconds is as good as the best reported terrestrially for this material. The ground samples were found to have a fully developed mosaic structure consisting of subgrains, whereas the flight sample dislocations were discrete and no mosaic substructure was evident. The defect density was reduced from 50-100,000 (one-g) to 500-25000 EPD (micro-g). These results were confirmed using rocking curve analysis, synchrotron topography, and etch pit analysis. The low dislocation density is thought to have resulted from the near-absence of hydrostatic pressure which allowed the melt to solidify with minimum or no wall contact, resulting in very low stress being exerted on the crystal during growth or during post-solidification cooling.

D J Larson, Jr.

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN

Chemical recycling of mixed textile waste

Globally, less than 0.5% of postconsumer textile waste is recycled, with the majority incinerated or ending up in landfills. Most postconsumer textiles are mixed fibers, complicating mechanical recycling due to material blends and contaminants. Here, we demonstrate the chemical conversion of postconsumer mixed textile waste using microwave-assisted glycolysis over a ZnO catalyst followed by solvent dissolution. This approach electrifies the process heat while allowing rapid depolymerization of polyester and spandex to their monomers in 15 minutes. A simple solvent dissolution enables the separation of cotton and nylon. We assess the quality of all components through extensive material characterization, discuss their potential for sustainable recycling, and provide a techno-economic analysis of the economic feasibility of the process.

Science & Technology - Other Topics

Development of a One-Domain Volume-Averaged Navier–Stokes Solver

The interaction between a high-enthalpy flow and a thermal protection material is inherently multiscale and multiphysics. In conventional aerothermal analyses, the external flow and material response are generally modeled using separate computational domains coupled through boundary conditions at the material surface. Although this approach has supported many practical applications, it requires assumptions about the location and behavior of the interface and may become difficult to apply when material decomposition, internal reactions, and surface recession substantially alter the porous structure. This report presents the development of a one-domain formulation in which the free-fluid and porous-material regions are represented within a single computational domain. The formulation is based on the volume-averaged Navier–Stokes (VANS) equations, derived from the governing equations for reacting, compressible flow and condensed material. Volume averaging transfers the influence of the unresolved material microstructure to the macroscale equations through effective transport properties, interfacial source terms, and dispersion fluxes. Particular attention is given to regions in which porosity and permeability vary rapidly, including the diffuse transition between a porous material and the surrounding fluid. The resulting equations are implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO). The report describes the pressure–velocity coupling strategy used by the solver, examines spatial filtering techniques for deriving effective properties, and evaluates the influence of a smoothly varying interface permeability. Numerical demonstrations include canonical porous-flow configurations, a flow-tube configuration representative of FiberForm® permeability experiments, and the oxidation of a porous carbon material. The purpose of this work is to establish a mathematical and computational foundation for a unified treatment of flow and thermal protection material response. The present formulation is intended to support the progressive inclusion of additional physical processes, including multicomponent transport, finite-rate gas–surface chemistry, pyrolysis, internal oxidation, and material recession. It also provides a framework for connecting pore-scale simulations and microstructural characterization with macroscale aerothermal-response calculations. This report is intended for researchers and engineers working in computational fluid dynamics, porous-media transport, material response, and thermal protection system modeling. It documents both the theoretical development and the initial numerical assessment of the one-domain approach, while identifying the closure of effective and dispersion terms as an important subject for continued investigation.

Ablation

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Fifth Annual Workshop on Space Operations Applications and Research (Soar 1991), Volume 1

More than 110 papers were presented at this Symposium, sponsored by the U.S. Air Force Phillips Laboratory, the University of Houston-Clear Lake, and NASA JSC. The technical areas covered were Intelligent Systems, Automation and Robotics, Human Factors and Life Sciences, and Environmental Interactions. The U.S. Air Force and NASA programmatic overviews and panel discussions were also held in each technical area. These proceedings, along with the comments and suggestions made by the panelists and keynote speakers, will be used in assessing the progress made in joint USAF/NASA projects and activities. Furthermore, future collaborative/joint programs will also be identified. The symposium proceedings includes papers covering various disciplines presented by experts from NASA, the Air Force, universities, and industry.

Mars missions

Reliability Assessment of Solid-State Circuit Breakers (CRADA CRD-21-21469, Project 4 Final Report)

Growth in power requirements and the complexity of emerging distribution systems are creating the need for new solid-state products for many applications. The qualification requirements, testing standards and life-cycle management practices of solid-state devices used in protection applications is not established. The project will leverage newly developed accelerated testing capabilities design specifically for protection applications to generate large data sets that will enable advanced digital techniques for data analysis and embedded health monitoring.

14 SOLAR ENERGY

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory

Hybrid Bio-Based Composites: Enabling Cellulose Nanofiber (CNF) Incorporation into Composites via Macroscale Natural Fiber Carriers

Cellulose nanofibers (CNFs) have significant potential in composites as additives to improve mechanical properties, melt rheology, and more. However, agglomeration of CNFs is a key challenge in composite melt processing as obtaining nano-level dispersion of CNFs often requires cost- and energy-intensive processes (e.g., solvent exchange or freeze drying) due to the strong hornification tendencies of CNF. Herein, we avoid these challenges by using a natural fiber carrier method to integrate CNF into thermoplastic composites. Fibers are co-dried to create a hybrid fiber feedstock for compounding in which natural fibers are decorated with dispersed nanofibers. The hybridized fibers result in up to a 24% increase in tensile strength and up to a 35% increase in Young’s modulus compared to composites only containing natural fibers. The lignocellulosic nanofibers are found to outperform their purely cellulosic counterpart, which is theorized to be due to either an increased propensity for fibrillation of the lignocellulosic fibers or the increased hydrophobicity of the fibers due to the presence of lignin. Surface analysis of fiber feedstocks, via streaming potential measurements and dynamic light scattering (DLS), confirmed a significant change in the feedstock hydrophobicity before and after hybridization. While mild additions of CNF (1 wt.% on the macroscale fiber) do not impact the composite melt viscosity, the viscosity is found to increase at higher CNF loadings (5 wt.% on the macroscale fiber), indicating its utility as a rheology modifier. Lastly, use of these materials as novel feedstocks for medium-scale additive manufacturing in high-fidelity part production was demonstrated.

bio-based

Complex-Valued Intermolecular Coupling Enables Directional Exciton Transport in Excitonic Circuits

Molecular systems capable of directing the flow of excitons are key to the development and optimization of optoelectronic materials. The transport of excitons across multiple molecules is governed by an intermolecular electronic coupling network. In this article, we consider the effects of complex-valued intermolecular electronic coupling on exciton transport. Here, we present a molecular motif capable of generating complex-valued coupling under excitation with circularly polarized light. We use theoretical modeling and simulation to illustrate how complex coupling can be leveraged to drive the rotational flux of excitons in cyclic molecular networks and direct the exciton population in branched molecular networks.

chromophores

Laboratory Investigations: Low Earth Orbit Environment Chemistry With Spacecraft Surfaces

Long-term space operations that require exposure of material to the low earth orbit (LEO) environment must take into account the effects of this highly oxidative atmosphere on material properties and the possible contamination of the spacecraft surroundings. Ground-based laboratory experiments at Los Alamos using a newly developed hyperthermal atomic oxygen (AO) source have shown that not only are hydrocarbon based materials effected but that inorganic materials such as MoS2 are also oxidized and that thin protective coatings such as Al2O3 can be breached, producing oxidation of the underlying substrate material. Gas-phase reaction products, such as SO2 from oxidation of MoS2 and CO and CO2 from hydrocarbon materials, have been detected and have consequences in terms of spacecraft contamination. Energy loss through gas-surface collisions causing spacecraft drag has been measured for a few select surfaces and has been found to be highly dependent on the surface reactivity.

Jon B Cross

Multifrequency, Multipolarization External Calibration of the SIR-C/X-SAR Radars

Progress and the future plans for the following objectives are discussed: (1) Assess the accuracy at which the SIR-C/X-SAR standard data products can be calibrated through the use of ground calibrators to estimate the end-to-end system polarization calibration constants (or distortion parameters) and incorporate the constants into the data processing; (2) Study the cross-calibration between three multipolarization systems: SIR-C, the National Aeronautics and Space Administration/Jet Propulsion Laboratory (NASA/JPL) DC-8 SAR, and the University of Michigan ground-based polarimetric scatterometer; (3) Evaluate the calibration "stability" of SIR-C/X-SAR (measured by variations in the calibration constants) over the range swath width and over a specified distance in azimuth. Variations over a 12-hour period (between ascending and descending passes) will also be studied; and (4) Develop a cost-effective calibration plan including development of inexpensive polarimetric active calibrators.

Anthony Freeman

Global Precipitation Measurement (GPM) Spacecraft Lithium Ion Battery Micro-Cycling Investigation

The Global Precipitation Measurement (GPM) spacecraft was jointly developed by NASA and JAXA. It is a Low Earth Orbit (LEO) spacecraft launched on February 27, 2014. The power system is a Direct Energy Transfer (DET) system designed to support 1950 watts orbit average power. The batteries use SONY 18650HC cells and consist of three 8s by 84p batteries operated in parallel as a single battery. During instrument integration with the spacecraft, large current transients were observed in the battery. Investigation into the matter traced the cause to the Dual-Frequency Precipitation Radar (DPR) phased array radar which generates cyclical high rate current transients on the spacecraft power bus. The power system electronics interaction with these transients resulted in the current transients in the battery. An accelerated test program was developed to bound the effect, and to assess the impact to the mission.

Lithium Ion Battery Performance