Search NASA⌕ Search

SEARCH · Search NASA

Results for “classifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

A comparison of histopathology imaging comprehension algorithms based on multiple instance learning

Whole slide imaging (WSI), also called digital virtual microscopy, is a new imaging modality. It allows for the application of AI and machine learning methods to cancer pathology to help establish a means for the automatic diagnosis of cancer cases. However, designing machine-learning models for WSI is computationally challenging due to its required ultra-high resolution. The current state-of-the-art models use multiple instance learning (MIL). MIL is a weakly-supervised learning method in which the model uses an array of inferences from many smaller instances to make a final classification about the entire set. In the context of WSI, researchers divide the ultra-high-resolution image into many patches. The model then classifies the slide based on an array of inferences from the patches. Among several ways of making the final classification, attention-based mechanisms have resulted in superb accuracy scores. The Transformer, one attention-based algorithm, has reported substantial improvements for WSI comprehension tasks. In this project, we studied and compared several WSI comprehension algorithms. We used the following three datasets: CAMELYON16+17, TCGALung, and TCGA-Kidney. We found that attention-based MIL algorithms performed better than standard MIL algorithms for classifying WSI images, achieving a higher mean accuracy and AUC. However, none of the attention-based algorithms performed significantly better than the others, reporting accuracy scores that varied widely. Presumably, it is due to the limited availability of training samples in the data corpus. Since it is not easy to increase the samples from human subjects, some machine learning techniques like transfer learning could help mitigate this issue.

Saunders, Adam↗

Characterization of mammographic masses based on level set segmentation with new image features and patient information

Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A{sub z} value of 0.83{+-}0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A{sub z} values were 0.85{+-}0.01 and 0.87{+-}0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening mammography with 132 benign and 197 malignant ROIs containing masses achieved a view-based A{sub z} value of 0.84{+-}0.02.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classification of breast computed tomography data

Differences in breast tissue composition are important determinants in assessing risk, identifying disease in images and following changes over time. This paper presents an algorithm for tissue classification that separates breast tissue into its three primary constituents of skin, fat and glandular tissue. We have designed and built a dedicated breast CT scanner. Fifty-five normal volunteers and patients with mammographically identified breast lesions were scanned. Breast CT voxel data were filtered using a 5 pt median filter and the image histogram was computed. A two compartment Gaussian fit of histogram data was used to provide an initial estimate of tissue compartments. After histogram analysis, data were input to region-growing algorithms and classified as to belonging to skin, fat or gland based on their value and architectural features. Once tissues were classified, a more detailed analysis of glandular tissue patterns and a more quantitative analysis of breast composition was made. Algorithm performance assessment demonstrated very good or excellent agreement between algorithm and radiologist observers in 97.7% of the segmented data. We observed that even in dense breasts the fraction of glandular tissue seldom exceeded 50%. For most individuals the composition is better characterized as being a 70% (fat)-30% (gland) composition than a 50% (fat)-50% (gland) composition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A{sub z}) under the receiver operating characteristic curve. Results: The test A{sub z} values from the DBT-slice approach ranged from 0.87{+-}0.03 to 0.93{+-}0.02, while those from the PV approach ranged from 0.78{+-}0.04 to 0.84{+-}0.04. The highest test A{sub z} of 0.93{+-}0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test A{sub z} of 0.84{+-}0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images.

60 APPLIED LIFE SCIENCES↗

A neural network based 3D/3D image registration quality evaluator for the head-and-neck patient setup in the absence of a ground truth

Purpose: To develop a neural network based registration quality evaluator (RQE) that can identify unsuccessful 3D/3D image registrations for the head-and-neck patient setup in radiotherapy. Methods: A two-layer feed-forward neural network was used as a RQE to classify 3D/3D rigid registration solutions as successful or unsuccessful based on the features of the similarity surface near the point-of-solution. The supervised training and test data sets were generated by rigidly registering daily cone-beam CTs to the treatment planning fan-beam CTs of six patients with head-and-neck tumors. Two different similarity metrics (mutual information and mean-squared intensity difference) and two different types of image content (entire image versus bony landmarks) were used. The best solution for each registration pair was selected from 50 optimizing attempts that differed only by the initial transformation parameters. The distance from each individual solution to the best solution in the normalized parametrical space was compared to a user-defined error threshold to determine whether that solution was successful or not. The supervised training was then used to train the RQE. The performance of the RQE was evaluated using the test data set that consisted of registration results that were not used in training. Results: The RQE constructed using the mutual information had very good performance when tested using the test data sets, yielding the sensitivity, the specificity, the positive predictive value, and the negative predictive value in the ranges of 0.960-1.000, 0.993-1.000, 0.983-1.000, and 0.909-1.000, respectively. Adding a RQE into a conventional 3D/3D image registration system incurs only about 10%-20% increase of the overall processing time. Conclusions: The authors' patient study has demonstrated very good performance of the proposed RQE when used with the mutual information in identifying unsuccessful 3D/3D registrations for daily patient setup. The classifier had very good generality and required only to be trained once for each implementation. When the RQE is incorporated with an automated 3D/3D image registration system, it can improve the robustness of the system.

60 APPLIED LIFE SCIENCES↗

Concurrent segmentation of the prostate on MRI and CT via linked statistical shape models for radiotherapy planning

Purpose: Prostate gland segmentation is a critical step in prostate radiotherapy planning, where dose plans are typically formulated on CT. Pretreatment MRI is now beginning to be acquired at several medical centers. Delineation of the prostate on MRI is acknowledged as being significantly simpler to perform, compared to delineation on CT. In this work, the authors present a novel framework for building a linked statistical shape model (LSSM), a statistical shape model (SSM) that links the shape variation of a structure of interest (SOI) across multiple imaging modalities. This framework is particularly relevant in scenarios where accurate boundary delineations of the SOI on one of the modalities may not be readily available, or difficult to obtain, for training a SSM. In this work the authors apply the LSSM in the context of multimodal prostate segmentation for radiotherapy planning, where the prostate is concurrently segmented on MRI and CT. Methods: The framework comprises a number of logically connected steps. The first step utilizes multimodal registration of MRI and CT to map 2D boundary delineations of the prostate from MRI onto corresponding CT images, for a set of training studies. Hence, the scheme obviates the need for expert delineations of the gland on CT for explicitly constructing a SSM for prostate segmentation on CT. The delineations of the prostate gland on MRI and CT allows for 3D reconstruction of the prostate shape which facilitates the building of the LSSM. In order to perform concurrent prostate MRI and CT segmentation using the LSSM, the authors employ a region-based level set approach where the authors deform the evolving prostate boundary to simultaneously fit to MRI and CT images in which voxels are classified to be either part of the prostate or outside the prostate. The classification is facilitated by using a combination of MRI-CT probabilistic spatial atlases and a random forest classifier, driven by gradient and Haar features. Results: The authors acquire a total of 20 MRI-CT patient studies and use the leave-one-out strategy to train and evaluate four different LSSMs. First, a fusion-based LSSM (fLSSM) is built using expert ground truth delineations of the prostate on MRI alone, where the ground truth for the gland on CT is obtained via coregistration of the corresponding MRI and CT slices. The authors compare the fLSSM against another LSSM (xLSSM), where expert delineations of the gland on both MRI and CT are employed in the model building; xLSSM representing the idealized LSSM. The authors also compare the fLSSM against an exclusive CT-based SSM (ctSSM), built from expert delineations of the gland on CT alone. In addition, two LSSMs trained using trainee delineations (tLSSM) on CT are compared with the fLSSM. The results indicate that the xLSSM, tLSSMs, and the fLSSM perform equivalently, all of them out-performing the ctSSM. Conclusions: The fLSSM provides an accurate alternative to SSMs that require careful expert delineations of the SOI that may be difficult or laborious to obtain. Additionally, the fLSSM has the added benefit of providing concurrent segmentations of the SOI on multiple imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

60 APPLIED LIFE SCIENCES↗

Parametrization of textural patterns in {sup 123}I-ioflupane imaging for the automatic detection of Parkinsonism

Purpose: A novel approach to a computer aided diagnosis system for the Parkinson's disease is proposed. This tool is intended as a supporting tool for physicians, based on fully automated methods that lead to the classification of{sup 123}I-ioflupane SPECT images. Methods: {sup 123}I-ioflupane images from three different databases are used to train the system. The images are intensity and spatially normalized, then subimages are extracted and a 3D gray-level co-occurrence matrix is computed over these subimages, allowing the characterization of the texture using Haralick texture features. Finally, different discrimination estimation methods are used to select a feature vector that can be used to train and test the classifier. Results: Using the leave-one-out cross-validation technique over these three databases, the system achieves results up to a 97.4% of accuracy, and 99.1% of sensitivity, with positive likelihood ratios over 27. Conclusions: The system presents a robust feature extraction method that helps physicians in the diagnosis task by providing objective, operator-independent textural information about{sup 123}I-ioflupane images, commonly used in the diagnosis of the Parkinson's disease. Textural features computation has been optimized by using a subimage selection algorithm, and the discrimination estimation methods used here makes the system feature-independent, allowing us to extend it to other databases and diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗

TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected by Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.

60 APPLIED LIFE SCIENCES↗

WE-E-BRE-05: Ensemble of Graphical Models for Predicting Radiation Pneumontis Risk

Purpose: We propose a prior knowledge-based approach to construct an interaction graph of biological and dosimetric radiation pneumontis (RP) covariates for the purpose of developing a RP risk classifier. Methods: We recruited 59 NSCLC patients who received curative radiotherapy with minimum 6 month follow-up. 16 RP events was observed (CTCAE grade ≥2). Blood serum was collected from every patient before (pre-RT) and during RT (mid-RT). From each sample the concentration of the following five candidate biomarkers were taken as covariates: alpha-2-macroglobulin (α2M), angiotensin converting enzyme (ACE), transforming growth factor β (TGF-β), interleukin-6 (IL-6), and osteopontin (OPN). Dose-volumetric parameters were also included as covariates. The number of biological and dosimetric covariates was reduced by a variable selection scheme implemented by L1-regularized logistic regression (LASSO). Posterior probability distribution of interaction graphs between the selected variables was estimated from the data under the literature-based prior knowledge to weight more heavily the graphs that contain the expected associations. A graph ensemble was formed by averaging the most probable graphs weighted by their posterior, creating a Bayesian Network (BN)-based RP risk classifier. Results: The LASSO selected the following 7 RP covariates: (1) pre-RT concentration level of α2M, (2) α2M level mid- RT/pre-RT, (3) pre-RT IL6 level, (4) IL6 level mid-RT/pre-RT, (5) ACE mid-RT/pre-RT, (6) PTV volume, and (7) mean lung dose (MLD). The ensemble BN model achieved the maximum sensitivity/specificity of 81%/84% and outperformed univariate dosimetric predictors as shown by larger AUC values (0.78∼0.81) compared with MLD (0.61), V20 (0.65) and V30 (0.70). The ensembles obtained by incorporating the prior knowledge improved classification performance for the ensemble size 5∼50. Conclusion: We demonstrated a probabilistic ensemble method to detect robust associations between RP covariates and its potential to improve RP prediction accuracy. Our Bayesian approach to incorporate prior knowledge can enhance efficiency in searching of such associations from data. The authors acknowledge partial support by: 1) CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290) and 2) The Terry Fox Foundation Strategic Training Initiative for Excellence in Radiation Research for the 21st Century (EIRR21)

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-05: Implementation of Incident Learning in the Safety and Quality Management of Radiotherapy: The Primary Experience in a New Established Program with Advanced Techniques

Purpose: To explore the implementation and effectiveness of incident learning for the safety and quality of radiotherapy in a new established radiotherapy program with advanced technology. Methods: Reference to the consensus recommendations by American Association of Physicist in Medicine, an incident learning system was specifically designed for reporting, investigating, and learning of individual radiotherapy incidents in a new established radiotherapy program, with 4D CBCT, Ultrasound guided radiotherapy, VMAT, gated treatment delivered on two new installed linacs. The incidents occurring in external beam radiotherapy from February, 2012 to January, 2014 were reported. Results: A total of 33 reports were analyzed, including 28 near misses and 5 incidents. Among them, 5 originated in imaging for planning, 25 in planning, 1 in plan transfer, 1 in commissioning and 1 in treatment delivery. Among them, three near misses originated in the safety barrier of the radiotherapy process. In terms of error type, 1 incident was classified as wrong patient, 7 near misses/incidents as wrong site, 6 as wrong laterality, 5 as wrong dose, 7 as wrong prescription, and 7 as suboptimal plan quality. 5 incidents were all classified as grade 1/2 of dosimetric severity, 1 as grade 0, and the other 4 as grade 1 of medical severity. For the causes/contributory factors, negligence, policy not followed, inadequate training, failure to develop an effective plan, and communication contributed to 19, 15, 12, 5 and 3 near misses/incidents, respectively. The average incident rate per 100 patients treated was 0.4; this rate fell to 0.28% in the second year from 0.56% in the first year. The rate of near miss fell to 1.24% from 2.22%. Conclusion: Effective incident learning can reduce the occurrence of near miss/incidents, enhance the culture of safety. Incident learning is an effective proactive method for improving the quality and safety of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Sensitivity study of voxel-based PET image comparison to image registration algorithms

Purpose: Accurate deformable registration is essential for voxel-based comparison of sequential positron emission tomography (PET) images for proper adaptation of treatment plan and treatment response assessment. The comparison may be sensitive to the method of deformable registration as the optimal algorithm is unknown. This study investigated the impact of registration algorithm choice on therapy response evaluation. Methods: Sixteen patients with 20 lung tumors underwent a pre- and post-treatment computed tomography (CT) and 4D FDG-PET scans before and after chemoradiotherapy. All CT images were coregistered using a rigid and ten deformable registration algorithms. The resulting transformations were then applied to the respective PET images. Moreover, the tumor region defined by a physician on the registered PET images was classified into progressor, stable-disease, and responder subvolumes. Particularly, voxels with standardized uptake value (SUV) decreases >30% were classified as responder, while voxels with SUV increases >30% were progressor. All other voxels were considered stable-disease. The agreement of the subvolumes resulting from difference registration algorithms was assessed by Dice similarity index (DSI). Coefficient of variation (CV) was computed to assess variability of DSI between individual tumors. Root mean square difference (RMS{sub rigid}) of the rigidly registered CT images was used to measure the degree of tumor deformation. RMS{sub rigid} and DSI were correlated by Spearman correlation coefficient (R) to investigate the effect of tumor deformation on DSI. Results: Median DSI{sub rigid} was found to be 72%, 66%, and 80%, for progressor, stable-disease, and responder, respectively. Median DSI{sub deformable} was 63%–84%, 65%–81%, and 82%–89%. Variability of DSI was substantial and similar for both rigid and deformable algorithms with CV > 10% for all subvolumes. Tumor deformation had moderate to significant impact on DSI for progressor subvolume with R{sub rigid} = − 0.60 (p = 0.01) and R{sub deformable} = − 0.46 (p = 0.01–0.20) averaging over all deformable algorithms. For stable-disease subvolumes, the correlations were significant (p < 0.001) for all registration algorithms with R{sub rigid} = − 0.71 and R{sub deformable} = − 0.72. Progressor and stable-disease subvolumes resulting from rigid registration were in excellent agreement (DSI > 70%) for RMS{sub rigid} < 150 HU. However, tumor deformation was observed to have negligible effect on DSI for responder subvolumes with insignificant |R| < 0.26, p > 0.27. Conclusions: This study demonstrated that deformable algorithms cannot be arbitrarily chosen; different deformable algorithms can result in large differences of voxel-based PET image comparison. For low tumor deformation (RMS{sub rigid} < 150 HU), rigid and deformable algorithms yield similar results, suggesting deformable registration is not required for these cases.

60 APPLIED LIFE SCIENCES↗

SU-E-J-183: Quantification of Motion During Hypo-Fractionated Prostate Cancer Radiation Therapy

Purpose: To quantify patient motion during hypo-fractionated prostate cancer treatment as tracked by Calypso™ 4D localization system. Methods: 50 prostate cancer patients with implanted Calypso beacons underwent hypofractionated IMRT treatment. Typical fraction size was 5 with doses of 5–8 Gy/fraction. 213 traces from the 50 patients were analyzed to quantify the probability of motion vs time starting from beam-on. Couch corrections applied by therapists were undone to obtain the natural course of patient motion. The Calypso data was used to identify vector displacements greater than 2 mm from the starting position. The direction of this vector was classified into one of the 26 directions (combinations of L/R, A/P, S/I). The probability of motion >2mm was estimated by computing the fraction of traces that exceed the 2mm threshold at each time point. The violating motion points were also binned by direction in order to identify specific directions that were more prone to movement. Results: The overall probability of motion greater than 2 mm at 5 and 10 minutes from beam-on were 27 % and 50% respectively. The primary directions in which motion occurred were Posterior-Inferior (PI) and Inferior (I) with a probability of 8.5% and 4% at 5 minutes and 10% for both at 10 minutes. Motion was classified into the following bins: 0–2, 2–3, 3–4, 4–5, 5–6, 6–7, 7–8 and greater than 8 mm. It is observed that motion < 2mm decreases from the first 5 minutes to the next while the higher magnitude components increase with time. Conclusion: The probability of prostate motion increases with time. The trend seen in the PI and I directions can be attributed to physiological factors like bladder filling. This probability can be factored in for scheduling intrafraction imaging and used to compare dosimetric impact of VMAT vs. IMRT plans. This work is supported in part by Varian Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used to classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.

60 APPLIED LIFE SCIENCES↗

SU-E-T-581: On the Value of LET as a Radiation Quality Descriptor for RBE

Purpose: To investigate the relationship between linear energy transfer (LET) and relative biological effectiveness (RBE) for protons and light ions, and the corresponding role of LET as a descriptor of radiation quality of hadron therapy. Methods: Monte Carlo (MC) proton and light ion (He, Li, C) tracks with LET < 30 eV nm{sup -1} were generated in an event-by-event mode. They were overlaid on a cell nucleus model containing 6×10{sup 9} nucleotide base pairs using an isotropic irradiation procedure that provides electronic equilibrium. Strand breaks (sbs) were scored in the DNA sugar-phosphate groups and further sub-classified into single or double sbs (ssbs or dsbs). Distributions of ssbs and dsbs for 2 Gy fractions were calculated to estimate RBE for the induction of initial dsbs with reference to {sup 60}Co. Additionally, sbs were classified based on their complexity (i.e. the number of sbs in each cluster). Results: An increase in LET for light ions of the same atomic number or a decrease in atomic number for ions of the same LET resulted in a lower kinetic energy of emitted secondary electrons. The clustering of DNA damage was more pronounced as reflected by the increase in proton RBE from ∼ 1.75 to 4 for LET values of 7 to 28 eV nm{sup -1}. A significant RBE decrease between protons, He, Li and C ions of the same LET was also noticed as function of the atomic number. Significant differences in ssbs and dsbs complexities were also seen for particles with the same LET, potentially supporting a clustering-based radiation quality descriptor. Conclusion: The LET-RBE relationships were simulated for proton and light ions and exhibited expected trends, including different RBEs for particles with the same LET but different atomic numbers. A complexity based radiation quality descriptor may allow better differentiation of RBE between radiation fields of similar LET. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-303-05: DCE-MRI Before and During Treatment for Prediction of Concurrent Chemotherapy and Radiation Therapy Response in Head and Neck Cancer

Purpose: To determine the ability of pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE- MRI) acquired before and during concurrent chemotherapy and radiation therapy to predict clinical response in patients with head and neck cancer. Methods: Eleven patients underwent a DCE-MRI scan at three time points: 1–2 weeks before treatment, 4–5 weeks after treatment initiation, and 3–4 months after treatment completion. Post-processing of MRI data included correction to reduce motion artifacts. The arterial input function was obtained by measuring the dynamic tracer concentration in the jugular veins. The volume transfer constant (Ktrans), extracellular extravascular volume fraction (ve), rate constant (Kep; Kep = Ktrans/ve), and plasma volume fraction (vp) were computed for primary tumors and cervical nodal masses. Patients were categorized into two groups based on response to therapy at 3–4 months: responders (no evidence of disease) and partial responders (regression of disease). Responses of the primary tumor and nodes were evaluated separately. A linear classifier and receiver operating characteristic curve analyses were used to determine the best model for discrimination of responders from partial responders. Results: When the above pharmacokinetic parameters of the primary tumor measured before and during treatment were incorporated into the linear classifier, a discriminative accuracy of 88.9%, with sensitivity =100% and specificity = 66.7%, was observed between responders (n=6) and partial responders (n=3) for the primary tumor with the corresponding accuracy = 44.4%, sensitivity = 66.7%, and specificity of 0% for nodal masses. When only pre-treatment parameters were used, the accuracy decreased to 66.7%, with sensitivity = 66.7% and specificity = 66.7% for the primary tumor and decreased to 33.3%, sensitivity of 50%, and specificity of 0% for nodal masses. Conclusion: Higher accuracy, sensitivity, and specificity were obtained using DCE-MRI-derived pharmacokinetic parameters acquired before and during treatment as compared with those derived from the pre-treatment time-point, exclusively.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-10: Cancer Therapy Outcome Prediction Based On Dempster-Shafer Theory and PET Imaging

Purpose: In cancer therapy, utilizing FDG-18 PET image-based features for accurate outcome prediction is challenging because of 1) limited discriminative information within a small number of PET image sets, and 2) fluctuant feature characteristics caused by the inferior spatial resolution and system noise of PET imaging. In this study, we proposed a new Dempster-Shafer theory (DST) based approach, evidential low-dimensional transformation with feature selection (ELT-FS), to accurately predict cancer therapy outcome with both PET imaging features and clinical characteristics. Methods: First, a specific loss function with sparse penalty was developed to learn an adaptive low-rank distance metric for representing the dissimilarity between different patients’ feature vectors. By minimizing this loss function, a linear low-dimensional transformation of input features was achieved. Also, imprecise features were excluded simultaneously by applying a l2,1-norm regularization of the learnt dissimilarity metric in the loss function. Finally, the learnt dissimilarity metric was applied in an evidential K-nearest-neighbor (EK- NN) classifier to predict treatment outcome. Results: Twenty-five patients with stage II–III non-small-cell lung cancer and thirty-six patients with esophageal squamous cell carcinomas treated with chemo-radiotherapy were collected. For the two groups of patients, 52 and 29 features, respectively, were utilized. The leave-one-out cross-validation (LOOCV) protocol was used for evaluation. Compared to three existing linear transformation methods (PCA, LDA, NCA), the proposed ELT-FS leads to higher prediction accuracy for the training and testing sets both for lung-cancer patients (100+/−0.0, 88.0+/−33.17) and for esophageal-cancer patients (97.46+/−1.64, 83.33+/−37.8). The ELT-FS also provides superior class separation in both test data sets. Conclusion: A novel DST- based approach has been proposed to predict cancer treatment outcome using PET image features and clinical characteristics. A specific loss function has been designed for robust accommodation of feature set incertitude and imprecision, facilitating adaptive learning of the dissimilarity metric for the EK-NN classifier.

60 APPLIED LIFE SCIENCES↗