Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications

A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility ({+-}0.8%) in-field and good accuracy ({+-}1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of a simple method of hybrid collimation for megavoltage grid therapy

Purpose: Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and are not practical with some multileaf collimators. This work studies the feasibility of a hybrid collimation system for grid therapy that does not require multiple segments and can be easily implemented with widely available technical means. Methods: The authors have developed a system to generate a grid of beamlets by the simultaneous use of two perpendicular sets of equally spaced leaves that project stripe patterns in orthogonal directions. One of them is generated with the multileaf collimator integrated in the accelerator and the other with an in-house made collimator constructed with a low melting point alloy commonly available at radiation oncology departments. The characteristics of the grid fields for 6 and 18 MV have been studied with a shielded diode, an unshielded diode, and radiochromic film. Results: The grid obtained with the hybrid collimation is similar to some of the grids used clinically with respect to the beamlet size (about 1 cm) and the percentage of open beam (1/4 of the total field). The grid fields are less penetrating than the open fields of the same energy. Depending on the depth and the direction of the profiles (diagonal or along the principal axes), the measured valley-to-peak dose ratios range from 5% to 16% for 6 MV and from 9% to 20% for 18 MV. All the detectors yield similar results in the measurement of profiles and percent depth dose, but the shielded diode seems to overestimate the output factors. Conclusions: The combination of two stripe pattern collimators in orthogonal directions is a feasible method to obtain two-dimensional arrays of beamlets and has potential usefulness as an efficient way to deliver grid therapy. The implementation of this method is technically simpler than the construction of a conventional grid block.

60 APPLIED LIFE SCIENCES↗

SU-D-19A-04: Parameter Characterization of Electron Beam Monte Carlo Phase Space of TrueBeam Linacs

Purpose: For TrueBeam Monte Carlo simulations, Varian does not distribute linac head geometry and material compositions, instead providing a phase space file (PSF) for the users. The PSF has a finite number of particle histories and can have very large file size, yet still contains inherent statistical noises. The purpose of this study is to characterize the electron beam PSF with parameters. Methods: The PSF is a snapshot of all particles' information at a given plane above jaws including type, energy, position, and directions. This study utilized a preliminary TrueBeam PSF, of which validation against measurement is presented in another study. To characterize the PSF, distributions of energy, position, and direction of all particles are analyzed as piece-wise parameterized functions of radius and polar angle. Subsequently, a pseudo PSF was generated based on this characterization. Validation was assessed by directly comparing the true and pseudo PSFs, and by using both PSFs in the down-stream MC simulations (BEAMnrc/DOSXYZnrc) and comparing dose distributions for 3 applicators at 15 MeV. Statistical uncertainty of 4% was limited by the number of histories in the original PSF. Percent depth dose (PDD) and orthogonal (PRF) profiles at various depths were evaluated. Results: Preliminary results showed that this PSF parameterization was accurate, with no visible differences between original and pseudo PSFs except at the edge (6 cm off axis), which did not impact dose distributions in phantom. PDD differences were within 1 mm for R{sub 7} {sub 0}, R{sub 5} {sub 0}, R{sub 3} {sub 0}, and R{sub 1} {sub 0}, and PRF field size and penumbras were within 2 mm. Conclusion: A PSF can be successfully characterized by distributions for energy, position, and direction as parameterized functions of radius and polar angles; this facilitates generating sufficient particles at any statistical precision. Analyses for all other electron energies are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-273: Do Task Group External Beam QA Recommendations Guarantee Accurate Treatment Plan Dose Delivery?

Purpose: AAPM task groups 40/142 have provided an invaluable set of goals for physicists designing QA programs, attempting to standardize what would otherwise likely be a highly variable phenomenon across institutions. However, with the complexity of modalities such as VMAT, we hypothesize that following these guidelines to the letter might still allow unacceptable dose discrepancies. To explore this hypothesis we simulated machines bordering on QA acceptability, and calculated the effect on patient plans. Methods: Two errant machines were simulated in Aria/Eclipse, each just within task group criteria for output, percent depth dose, beam profile, gantry and collimator rotations, and jaw and MLC positions. One machine minimized dose to the PTV (machine A) and the other maximized dose to the OARs (machine B). Clinical treatment plans (3-phase prostate, n=3; hypofractionated lung, n=1) were calculated on these machines and the dose distributions compared. A prostate case was examined for contribution of error sources and evaluated using delivery QA data. Results: The prostate plans showed mean decreases in target D95 of 9.9% of prescription dose on machine A. On machine B, The rectal and bladder V70Gy each increased by 7.1 percentage points, while their V45Gy increased by 16.2% and 15.0% respectively. In the lung plan, the target D95 decreased by 12.8% and the bronchial tree Dmax increased by 21% of prescription dose, on machines A and B. One prostate plan showed target dose errors of 3.8% from MLC changes, 2% from output, ∼3% from energy and ∼0.5% from other factors. This plan achieved an 88.4% gamma passing rate using 3%/3mm using ArcCHECK. Conclusion: In the unlikely event that a machine exhibits all maximum errors allowed by TG 40/142, unacceptably large changes in dose delivered are possible especially in highly modulated VMAT plans, despite the machine passing routine QA.

60 APPLIED LIFE SCIENCES↗

Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT 4

Purpose: This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and GEANT4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. Methods: A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within the Monaco treatment planning system to model dose for the Elekta™ magnetic resonance imaging (MRI) Linac, was compared against GEANT4 (v10.1). This was done in the presence or absence of a 1.5 T static magnetic field directed orthogonally to the radiation beam axis. Phantoms with material compositions of water, ICRU lung, ICRU compact-bone, and titanium were used for this purpose. Beams with 2 MeV monoenergetic photons as well as a 7 MV histogrammed spectrum representing the MRI Linac spectrum were emitted from a point source using a nominal source-to-surface distance of 142.5 cm. Field sizes ranged from 1.5 × 1.5 to 10 × 10 cm{sup 2}. Dose scoring was performed using a 3D grid comprising 1 mm{sup 3} voxels. The production thresholds were equivalent for both codes. Results were analyzed based upon a voxel by voxel dose difference between the two codes and also using a volumetric gamma analysis. Results: Comparisons were drawn from central axis depth doses, cross beam profiles, and isodose contours. Both in the presence and absence of a 1.5 T static magnetic field the relative differences in doses scored along the beam central axis were less than 1% for the homogeneous water phantom and all results matched within a maximum of ±2% for heterogeneous phantoms. Volumetric gamma analysis indicated that more than 99% of the examined volume passed gamma criteria of 2%—2 mm (dose difference and distance to agreement, respectively). These criteria were chosen because the minimum primary statistical uncertainty in dose scoring voxels was 0.5%. The presence of the magnetic field affects the dose at the interface depending upon the density of the material on either sides of the interface. This effect varies with the field size. For example, at the water-lung interface a 33.94% increase in dose was observed (relative to the D{sub max}), by both GPUMCD and GEANT4 for the field size of 2 × 2 cm{sup 2} (compared to no B-field case), which increased to 47.83% for the field size of 5 × 5 cm{sup 2} in the presence of the magnetic field. Similarly, at the lung-water interface, the dose decreased by 19.21% (relative to D{sub max}) for a field size of 2 × 2 cm{sup 2} and by 30.01% for 5 × 5 cm{sup 2} field size. For more complex combinations of materials the dose deposition also becomes more complex. Conclusions: The GPUMCD algorithm showed good agreement against GEANT4 both in the presence and absence of a 1.5 T external magnetic field. The application of 1.5 T magnetic field significantly alters the dose at the interfaces by either increasing or decreasing the dose depending upon the density of the material on either side of the interfaces.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-176: Therapeutic Proton Beam Range Measurement Method with EBT3 Film

Purpose: Ocular proton therapy has the following advantages: i) sparing optic nerve, ii) the minimal dose is delivered to surrounding normal tissues. Since the proton therapy center was opened in 2007, 30 patients with ocular tumor have been treated at National Cancer Center using single scattering technique. To develop a solid eye phantom which can verify the output and the beam range with EBT3 film for independent patient QA in ocular proton therapy. Methods: The proton therapy is very effective to treat ocular tumor, because of the Bragg peak feature. In general, the beam shape of eye treatment is about 3 cm in diameter and the beam range is under 5 cm. However, proton therapy has uncertainty of beam range problem due to various stopping power of normal tissue, bone, air and so on, so that we should verify the beam range before treatment. For this purpose, a new PMMA phantom with wedge has been developed to use the film dosimetry and the ionization chamber. It is able to place a film on the slope of the phantom, which the spread out Bragg Peak by the water equivalent thickness value of PMMA can be made on the film. We considered to relation with quenching effect of proton energy and range for simple second check. In addition, the ionization chamber (Pin-point chamber, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The output difference and beam range difference were less than 2% and 1.0 mm, respectively, between the measurement and the plan. Conclusion: An eye phantom was developed and its performance was evaluated successfully and it was useful to verify the output. Also with EBT3 film with the quenching effect for measurement depth-dose profile, range to patient QA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-506: Development and Commissioning of the Effective and Efficient Grid Therapy Using High Dose Rate Flattening Filter Free Beam and Multileaf Collimator

Purpose: Treating bulky tumors with grid therapy (GT) has demonstrated high response rates. Long delivery time (∼15min), with consequent increased risk of intrafraction motion, is a major disadvantage of conventional MLC-based GT (MLC-GT). The goal of this study was to develop and commission a MLC-GT technique with similar dosimetric characteristics, but more efficient delivery. Methods: Grid plan was designed with 10X-FFF (2400MU/min) beam and MLC in a commercial treatment planning system (TPS). Grid size was 1cm by 1cm and grid-to-grid distance was 2cm. Field-in-field technique was used to flatten the dose profile at depth of 10cm. Prescription was 15Gy at 1.5cm depth. Doses were verified at depths of 1.5cm, 5cm and 10cm. Point dose was measured with a plastic scintillator detector (PSD) while the planar dose was measured with calibrated Gafchromic EBT3 films in a 20cm think, 30cmx30cm solid water phantom. The measured doses were compared to the doses calculated in the treatment planning system. Percent depth dose (PDD) within the grid was also measured using EBT3 film. Five clinical cases were planned to compare beam-on time. Results: The valley-to-peak dose ratio at the 3 depths was approximately 10–15%, which is very similar to published result. The average point dose difference between the PSD measurements and TPS calculation is 2.1±0.6%. Film dosimetry revealed good agreement between the delivered and calculated dose. The average gamma passing rates at the 3 depths were 95% (3%, 1mm). The average percent difference between the measured PDD and calculated PDD was 2.1% within the depth of 20cm. The phantom plan delivery time was 3.6 min. Average beam-on time was reduced by 66.1±5.6% for the 5 clinical cases. Conclusion: An effective and efficient GT technique was developed and commissioned for the treatment of bulky tumors using FFF beam combined with MLC and automation. The Department of Radiation Oncology at Henry Ford Health System receives research support from Varian Medical Systems and Philips Health Care.

60 APPLIED LIFE SCIENCES↗

SU-F-T-521: Flattening-Filter-Free Beam Parameters Comparison From Different Linac Machine Types

Purpose: Novel linac machines, TrueBeam (TB) and Elekta Versa have updated head designing and software control system, include flattening-filter-free (FFF) photon and electron beams. Later on FFF beams were also introduced on C-Series machines. In this work FFF beams for same energy 6MV but from different machine versions were studied with reference to beam data parameters. Methods: The 6MV-FFF percent depth doses, profile symmetry and flatness, dose rate tables, and multi-leaf collimator (MLC) transmission factors were measured during commissioning process of both C-series and Truebeam machines. The scanning and dosimetric data for 6MV-FFF beam from Truebeam and C-Series linacs was compared. A correlation of 6MV-FFF beam from Elekta Versa with that of Varian linacs was also found. Results: The scanning files were plotted for both qualitative and quantitative analysis. The dosimetric leaf gap (DLG) for C-Series 6MV-FFF beam is 1.1 mm. Published values for Truebeam dosimetric leaf gap is 1.16 mm. 6MV MLC transmission factor varies between 1.3 % and 1.4 % in two separate measurements and measured DLG values vary between 1.32 mm and 1.33 mm on C-Series machine. MLC transmission factor from C-Series machine varies between 1.5 % and 1.6 %. Some of the measured data values from C-Series FFF beam are compared with Truebeam representative data. 6MV-FFF beam parameter values like dmax, OP factors, beam symmetry and flatness and additional parameters for C-Series and Truebeam liancs will be presented and compared in graphical form and tabular data form if selected. Conclusion: The 6MV flattening filter (FF) beam data from C-Series & Truebeam and 6MV-FFF beam data from Truebeam has already presented. This particular analysis to compare 6MV-FFF beam from C-Series and Truebeam provides opportunity to better elaborate FFF mode on novel machines. It was found that C-Series and Truebeam 6MV-FFF dosimetric and beam data was quite similar.

60 APPLIED LIFE SCIENCES↗

Study of silicon doped with zinc ions and annealed in oxygen

The results of studies of the surface layer of silicon and the formation of precipitates in Czochralski n-Si (100) samples implanted with {sup 64}Zn{sup +} ions with an energy of 50 keV and a dose of 5 × 10{sup 16} cm{sup –2} at room temperature and then oxidized at temperatures from 400 to 900°C are reported. The surface is visualized using an electron microscope, while visualization of the surface layer is conducted via profiling in depth by elemental mapping using Auger electron spectroscopy. The distribution of impurity ions in silicon is analyzed using a time-of-flight secondary-ion mass spectrometer. Using X-ray photoelectron spectroscopy, the chemical state of atoms of the silicon matrix and zinc and oxygen impurity atoms is studied, and the phase composition of the implanted and annealed samples is refined. After the implantation of zinc, two maxima of the zinc concentration, one at the wafer surface and the other at a depth of 70 nm, are observed. In this case, nanoparticles of the Zn metal phase and ZnO phase, about 10 nm in dimensions, are formed at the surface and in the surface layer. After annealing in oxygen, the ZnO · Zn{sub 2}SiO{sub 4} and Zn · ZnO phases are detected near the surface and at a depth of 50 nm, respectively.

36 MATERIALS SCIENCE↗

Formation of Precipitates in Si Implanted with {sup 64}Zn{sup +} and {sup 16}O{sup +} Ions

The results of studying the surface Si layer and precipitate formation in CZ n-Si(100) samples sequentially implanted with {sup 64}Zn{sup +} ions with a dose of 5 × 10{sup 16} cm{sup 2} and energy of 100 keV and {sup 16}O{sup +} ions with the same dose but an energy of 33 keV at room temperature so that their projection paths R{sub p} = 70 nm would coincide are presented. The post-implantation samples are annealed for 1 h in an inert Ar medium in the temperature range of 400–900°C with a step of 100°C. The profiles of the implanted impurities are studied by time-of-flight secondary ion mass spectrometry. The Si surface is visualized using a scanning electron microscope, while the near-surface layer is visualized with the help of maps of elements formed by Auger electron spectroscopy with profiling over depth. The ZnO(002) texture is formed in an amorphized Si layer after the implantation of Zn and O ions. ZnO(102) crystallites of 5 nm in size are found in a recrystallized single-crystalline Si layer after annealing in Ar at 700°C.

36 MATERIALS SCIENCE↗

Utah FORGE: 16B(78)-32 RFS DSS Strain Change Rate vs. Depth During 16A(78)-32 Stimulation

This dataset contains strain change rate versus depth data acquired using a Rayleigh frequency shift (RFS) distributed strain sensing (DSS) system during hydraulic stimulation of well 16A(78)-32 at the Utah FORGE site in April 2024. The data were collected from an optical fiber installed in the annulus of production well 16B(78)-32, approximately 300 feet from the injection well. The dataset includes tabulated strain data and an explanation of the methodology used to generate the frac log, which integrates strain change rate signals over selected time windows to identify fracture events.

15 GEOTHERMAL ENERGY↗

Location Identifiers, Metadata, and Map for Field Measurements at the East-Taylor Watershed Community Observatory, Colorado, USA (Version 3.3)

This dataset contains identifiers, metadata, and a map of the locations where field measurements have been conducted at the East-Taylor Watershed Community Observatory located in the Upper Colorado River Basin, United States. This is version 3.3 of the dataset and replaces the prior version 3.2 (see below for details on changes between the versions). Dataset description: The East River-Taylor Watershed is the primary field site of the Watershed Function Scientific Focus Area (WFSFA) and the Rocky Mountain Biological Laboratory. Researchers from several institutions generate highly diverse hydrological, biogeochemical, climate, vegetation, geological, remote sensing, and model data at the East-Taylor Watershed in collaboration with the WFSFA. Thus, the purpose of this dataset is to maintain an inventory of the field locations and instrumentation to provide information on the field activities in the East-Taylor Watershed and coordinate data collected across different locations, researchers, and institutions. The dataset contains (1) a README file with information on the various files, (2) three csv files describing the metadata collected for each surface point location, plot and region registered with the WFSFA, (3) csv files with metadata and contact information for each surface point location registered with the WFSFA, (4) a csv file with with metadata and contact information for plots, (5) a csv file with metadata for geographic regions and sub-regions within the watershed, (6) a compiled xlsx file with all the data and metadata which can be opened in Microsoft Excel, (7) a kml map of the locations plotted in the watershed which can be opened in Google Earth, (8) a jpg image of the kml map which can be viewed in any photo viewer, and (9) a zipped file with the registration templates used by the SFA team to collect location metadata. The zipped template file contains two csv files with the blank templates (point and plot), two csv files with instructions for filling out the location templates, and one compiled xlsx file with the instructions and blank templates together. Additionally, the templates in the xlsx include drop down validation for any controlled metadata fields. Persistent location identifiers (Location_ID) are determined by the WFSFA data management team and are used to track data and samples across locations. Dataset uses: This location metadata is used to update the Watershed SFA’s publicly accessible Field Information Portal (an interactive field sampling metadata exploration tool; https://wfsfa-data.lbl.gov/watershed/), the kml map file included in this dataset, and other data management tools internal to the Watershed SFA team. Version Information: The latest version of this dataset publication is version 3.3. This version contains 167 new point locations, 1 new plot, and 2 new geographic regions. Overall, there are a total of 1439 point locations, 75 plots, and 54 geographic regions. Additionally, the kml map of locations and image now includes two boundaries (Upper Ohio Creek (UO) and Carbon Creek (CA)) outside of the East River watershed (USGS HUC-10) and accompanying stream network that represents areas of focus. Refer to methods for further details on the version history. This dataset will be updated on a periodic basis with new measurement location information. Researchers interested in having their East-Taylor Watershed measurement locations added to this list should reach out to the WFSFA data management team at wfsfa-data@googlegroups.com. Acknowledgments: Please cite this dataset if using any of the location metadata in other publications or derived products. If using the location metadata for the 2018 NEON hyperspectral campaign, additionally cite Chadwick et al. (2020). doi:10.15485/1618130. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

2018 NEON and 2025 CHESS Campaigns↗

Soil carbon, nitrogen, and ice content data (2014-2018) at Happy Valley and Sagwon Hills in Northern Alaska, United States

This dataset contains three data files from soil data collected by sampling soil cores and pits across a toposequence on two hillslopes in permafrost affected soils in Northern Alaska, USA. Soil cores and profiles were excavated to 3m or until auger refusal. Samples were collected by genetic soil horizons for laboratory analysis and organized into complete soil profiles ordered depth. Soil carbon, nitrogen, and ice stocks (stocks_by_core.csv) were calculated from the core dataset . Data for mean values by depth increments (20,50,100,150,200 cm) of total soc, total nitrogen, bulk density, and ice content were determined and made available in this dataset (soc-tn-bd-ice-slab_tables.csv). Stocks by site are included in a separate file (stocks_by_site.csv). Each of these three files also has an associated data dictionary file (stocks_by_core_dd.csv, soc-tn-bd-ice-slab_tables_dd.csv, stocks_by_site_dd.csv). Finally, an FLMD file is also included (FLMD_Happy_Valley_Sagwon.csv).

54 ENVIRONMENTAL SCIENCES↗

Chemical Imaging with Cluster Ion Beams and Lasers

The objective of this Department of Energy project has been to create a novel nanoscale three-dimensional molecule-specific imaging capability for characterization of a wide range of materials. Specific accomplishments are (1) demonstrated the generality of strong field ionization using femtosecond IR pulsed lasers to post-ionize sputtered molecules with the least amount of induced fragmentation, (2) constructed a novel multi-pass optic to more effectively sample the ablation plume created by the cluster ion beam, (3) utilized the chemistry of gas cluster ion beams containing 1000 – 10000 species to improve desorption ionization efficiency and probe the mechanism of this phenomenon using SFI, (4) for the first time, allowed images to be acquired quantitatively by separating the desorption step from the ionization step and characterizing complex multicomponent and multilayer structures. A critical part of this research has been to (1) demonstrate the unique capabilities of our technology by unraveling the architecture of complex aerosol particles with heterogeneous in-depth compositions and (2) to reveal the distribution of hydrocarbons and long chain fatty acids in b. braunii algal colonies at the single cell level, and elucidate the mechanism of hydrocarbon excretion. In general this major jump in 3-dimensional imaging capability is leading to applications in many areas of energy-related research that have heretofore remained insoluble.

3-dimensional chemical imaging↗

Low Cost Corrugated Substrates for High Efficiency OLEDs (Final Report)

The external quantum efficiency (EQE) of a planar OLED is limited to 25%. Around 75% of the light is trapped in the substrate, waveguided and SPP modes. In this project, we demonstrated that nano-structures can significantly improve the EQE of OLEDs. The objective is to improve the EQE to 70% using corrugated substrate, low index layer incorporation and micro lens arrays. We conducted optical study of the operating devices using ARES measurement, and used the result to guide the design of corrugated substrates as well as the OLED stack for better performance. During the first year of the program, we have demonstrated over 60% EQE in a corrugated green OLED with half-ball lens for light extraction. By comparing, the optical characteristics of OLEDs fabricated on single and poly crystal corrugated structures, we confirm that the enhancement using corrugated substrates comes from waveguided and SPP modes extraction. To push the device EQE to 70%, further optimization of the corrugated substrate is needed. The extraction of waveguided and SPP modes are influenced by the corrugation pitch, depth and profile. Therefore, we developed a series of processes to precisely control the corrugation morphology. Through comparison of different corrugated substrates, we observed that while an abrupt surface profile results in stronger mode extraction, it also introduces strong leakage current; while a smooth profile are less efficient in mode extraction, it preserves the quality of an OLED. Based on these observations, we conclude that a single crystal hole corrugation results in optimum EQE % and low leakage current when planarized with PEDOT. To improve the extraction of waveguided mode, we also introduce a low index contrast layer (ICL) to increase the index contrast between corrugated ITO and glass interface. We optimized our recipe for the index contrast layer processing and reduced its refractive index from 1.50 to 1.38. As a result, the optimized device shows 47.6% EQE, which is 1.64 times higher than the reference planar device. By extracting the substrate mode with a hemispherical lens, we obtained an EQE of 71.6%, which is a 2.46 times enhancement. The cross-section SEM image reveals the high EQE is due to the formation of an air gap at the interface of the ICL, resulting in an increase of the index contrast to Δn ~ 1. We use angle-resolved electroluminescence spectroscopy (ARES) to demonstrate that the ICL improves the diffraction efficiency at the ITO/glass interface, extracts TM, TE waveguide and SPP mode more efficiently, and leads to the observed high efficiency. We also address the directional emission issue with the single crystalline microlens arrays (MLAs) by fabricating polycrystalline MLAs. The process uses colloidal assembly method to create a mono-layer of silica spheres, then uses PDMS stamps to replicate the pattern for multi-use imprinting. The MLAs are close-packed in short range but have random orientations in the long range. This avoids stronger extraction along the optical axes of single crystal MLAs and prevents the directional emission issue. We also demonstrate that the color shift induced by the corrugation can be minimized using MLAs. In this scenario, the MLAs work as diffuser to randomize the directional emission from extracted waveguide and SPP modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Investigation of a Small Low-Flow Marine Hydrokinetic (MHK) Turbine for Small Autonomous Unmanned Mobile Recharge Stations (CRADA Final Report)

This project will improve the hydrodynamic performance of the undershot waterwheel turbine with a flow concentrator designed by the Participant, using a computational fluid dynamics study. The influence of different result parameters including the number of blades, turbine profile, submerged depth, tip speed ratio, concentrator geometry and wave + current conditions will be assessed to maximize power performance and minimize structural loads.

16 TIDAL AND WAVE POWER↗

Long-term warming modulates diversity, vertical structuring of microbial communities, and sulfate reduction in coastal Baltic Sea sediments

Coastal waters such as those found in the Baltic Sea already suffer from anthropogenic related problems including increased algal blooming and hypoxia while ongoing and future climate change will likely worsen these effects. Microbial communities in sediments play a crucial role in the marine energy- and nutrient cycling, and how they are affected by climate change and shape the environment in the future is of great interest. The aims of this study were to investigate potential effects of prolonged warming on microbial community composition and nutrient cycling including sulfate reduction in surface (∼0.5 cm) to deeper sediments (∼ 24 cm). To investigate this, 16S rRNA gene amplicon sequencing was performed, and sulfate concentrations were measured and compared between sediments in a heated bay (which has been used as a cooling water outlet from a nearby nuclear power plant for approximately 50 years) and a nearby but unaffected control bay. The results showed variation in overall microbial diversity according to sediment depth and higher sulfate flux in the heated bay compared to the control bay. A difference in vertical community structure reflected increased relative abundances of sulfur oxidizing- and sulfate reducing bacteria along with a higher proportion of archaea, such as Bathyarchaeota, in the heated compared to the control bay. This was particularly evident closer to the sediment surface, indicating a compression of geochemical zones in the heated bay. These results corroborate findings in previous studies and additionally point to an amplified effect of prolonged warming deeper in the sediment, which could result in elevated concentrations of toxic compounds and greenhouse gases closer to the sediment surface.

16S rRNA gene amplicon↗

Trace elements profiles, notably Hg, from a preliminary study of the Apollo 15 deep-drill core.

The possible thermal gradient near the surface during a lunation is considered together with the heat flow from the interior, the physical process of Hg migration, the results from core and trench samples from previous missions, and other temperature sensitive phenomena that may help understand the processes. U, Os, and Ru concentrations in the deep drill core samples are of potential interest and are summarized in a table. The Os tends to parallel the Hg profile with depth.

Jovanovic, S.↗