Evaluation of Non-electric Market Options for a Light-water Reactor in the Midwest. Light Water Reactor Sustainability program

This study has addressed the technical feasibility and economic viability of LWR hybrid system operations based on realistic market around a specific reactor site in the Upper Midwest United States within the Great Lakes Region and near an industrial center that could benefit from more direct use of nuclear energy. The diverse industrial user and the electricity grid to optimize the revenue of the nuclear plant, depending on specific day-ahead electricity-grid capacity commitments and reserve capacity agreement requirements. For this market arrangement to work, the non-grid user is sold electricity without paying grid service fees (i.e., being considered a house load). This mode of energy sharing may require approval of governing utility commissions, depending on whether the hybrid operations can affect grid supply and manufacturing, agriculture, and transportation systems in this region provides several advantages to converting a nuclear plant into a hybrid plant that produces hydrogen and other feedstock commodities, such as polyethylene or formic acid, for example. Large-scale hydrogen production can essentially service several refineries within 20-30 miles of the nuclear plant. This would results in a measurable reduction of air-pollutant emissions reduction in the region. In addition, a large, consistent supply of hydrogen would draw new industries to the area—especially other steel-reduction and ammonia plants. For example, the nation’s first synthetic-fuels plant could also be sited near this hydrogen plant to convert CO 2 collected from the several ethanol plants in the region into methanol-based chemical feedstock and biofuels. With these perspectives in mind, this study has evaluated the business case for the following hybrid plant options.

08 HYDROGEN↗

Direct Current as an Integrating Platform for ZNE Buildings with EVs and Storage: DC Direct Systems – A Bridge to a Low Carbon Future?

Cost effective zero net energy (ZNE) schemes exist for many types of residential and commercial buildings. Yet, today’s alternating current (AC) based ZNE designs may be as much as 10% to 20% less efficient, more costly, and more complicated than a design based on direct current (DC) technologies. An increasing number of research organizations and manufacturers are just starting the process of developing products and conducting research and development (R&D) efforts. These early R&D efforts indicate that the use of DC technologies may deliver many energy and non-energy benefits relative to AC-based typologies. DC ZNE schemes may provide for an ideal integrating platform for natively DC-based onsite generation, storage, electric vehicle (EV) charging and end-use loads. Emerging empirical data suggest that DC end-use appliances are more efficient, simpler, more durable, and lower cost. DC technologies appear to provide ratepayers a lower cost pathway to achieve resilient ZNE buildings, and simultaneously yield a plethora of benefits. This paper draws from the current research effort entitled "Direct Current as an Integrating and Enabling Platform," co-led by the Lawrence Berkeley National Laboratory (LBNL), the California Institute for Energy and the Environment (CIEE), the Electric Power Research Institute (EPRI) and funded under the California Energy Commission’s Energy Program Investment Charge (CEC EPIC). The first phase of this EPIC research is focused on assembling and summarizing known global performance information on DC and DC-AC hybrid end-use appliances and power systems. This paper summarizes the information and insights gained from this research effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evi-Pro Lite API

This application programing interface provides output from NLR's EVI-Pro model and is used to power the EVI-Pro Lite tool at https://afdc.energy.gov/evi-pro-lite. These endpoints provide daily (24-hour) fleet-level charging load profiles for a variety of customizable scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Brief: Market and Policy Impacts Update

Utility-scale geothermal electricity generation plants have generally taken advantage of various government initiatives designed to stimulate private investment. This report investigates these initiatives to evaluate their impact on the associated cost of energy and the development of geothermal electric generating capacity using conventional hydrothermal technologies. We use the Cost ofRenewable Energy Spreadsheet Tool (CREST) to analyze the effects of tax incentives on project economics. Incentives include the production tax credit, U.S. Department of Treasury cash grant, the investment tax credit, and accelerated depreciation schedules. The second half of the report discusses the impact of the U.S. Department of Energy's (DOE) Loan Guarantee Program on geothermal electricproject deployment and possible reasons for a lack of guarantees for geothermal projects. For comparison, we examine the effectiveness of the 1970s DOE drilling support programs, including the original loan guarantee and industry-coupled cost share programs.

15 GEOTHERMAL ENERGY↗

Office of Electricity Delivery and Energy Reliability (OE) National Energy Technology Laboratory (NETL) American Recovery and Reinvestment Act 2009 United States Department of Energy

The purpose of this project was for Seeo to deliver the first ever large-scale or grid-scale prototype of a new class of advanced lithium-ion rechargeable batteries. The technology combines unprecedented energy density, lifetime, safety, and cost. The goal was to demonstrate Seeo’s entirely new class of lithium-based batteries based on Seeo’s proprietary nanostructured polymer electrolyte. This technology can enable the widespread deployment in Smart Grid applications and was demonstrated through the development and testing of a 10 kilowatt-hour (kWh) prototype battery system. This development effort, supported by the United States Department of Energy (DOE) enabled Seeo to pursue and validate the transformational performance advantages of its technology for use in grid-tied energy storage applications. The focus of this project and Seeo’s goal as demonstrated through the efforts made under this project is to address the utility market needs for energy storage systems applications, especially for residential and commercial customers tied to solar photovoltaic installations. In addition to grid energy storage opportunities Seeo’s technology has been tested with automotive drive cycles and is seen as equally applicable for battery packs for electric vehicles. The goals of the project were outlined and achieved through a series of specific tasks, which encompassed materials development, scaling up of cells, demonstrating the performance of the cells, designing, building and demonstrating a pack prototype, and providing an economic and environmental assessment. Nearly all of the tasks were achieved over the duration of the program, with only the full demonstration of the battery system and a complete economic and environmental analysis not able to be fully completed. A timeline over the duration of the program is shown in figure 1.

25 ENERGY STORAGE↗

Grande Ronde Basin Fish Habitat Enhancement Project : 2007 Annual Report.

On July 1, 1984 the Bonneville Power Administration and the Oregon Department of Fish and Wildlife entered into an intergovernmental contract to initiate fish habitat enhancement work in the Joseph Creek subbasin of the Grande Ronde River Basin in northeast Oregon. In 1985 the Upper and Middle Grande Ronde River, and Catherine Creek subbasins were included in the contract, and in 1996 the Wallowa River subbasin was added. The primary goal of 'The Grande Ronde Basin Fish Habitat Enhancement Project' is to create, protect, and restore riparian and instream habitat for anadromous salmonids, thereby maximizing opportunities for natural fish production within the basin. This project provided for implementation of Program Measure 703 (C)(1), Action Item 4.2 of the Northwest Power Planning Council's Columbia River Basin Fish and Wildlife Program (NPPC, 1987), and continues to be implemented as offsite mitigation for mainstem fishery losses caused by the Columbia River hydro-electric system. All work conducted by the Oregon Department of Fish and Wildlife and partners is on private lands and therefore requires that considerable time be spent developing rapport with landowners to gain acceptance of, and continued cooperation with this program throughout 10-15 year lease periods. Both passive and active restoration treatment techniques are used. Passive regeneration of habitat, using riparian exclosure fencing and alternate water sources are the primary method to restore degraded streams when restoration can be achieved primarily through changes in management. Active restoration techniques using plantings, bioengineering, site-specific instream structures, or whole stream channel alterations are utilized when streams are more severely degraded and not likely to recover in a reasonable timeframe. Individual projects contribute to and complement ecosystem and basin-wide watershed restoration efforts that are underway by state, federal, and tribal agencies, and coordinated by the Grande Ronde Model Watershed Program (Project. No.199202601). Work undertaken during 2007 included: (1) Starting 1 new fencing project in the NFJD subbasin that will protect an additional 1.82 miles of stream and 216.2 acres of habitat; (2) Constructing 0.47 miles of new channel on the Wallowa River to enhance habitat, restore natural channel dimensions, pattern and profile and reconnect approximately 18 acres of floodplain and wetland habitat; (3) Planting 22,100 plants along 3 streams totaling 3.6 stream miles; (4) Establishing 34 new photopoints on 5 projects and retaking 295 existing photopoint pictures; (5) Monitoring stream temperatures at 10 locations on 5 streams and conducting other monitoring activities; (6) Completing riparian fence, water gap and other maintenance on 116.8 miles of project fences; (7) Initiated writing of a comprehensive project summary report that will present a summary of conclusions of the benefits to focal species and management recommendations for the future. Since initiation of this program 56 individual projects have been implemented, monitored and maintained along 84.8 miles of anadromous fish bearing streams that protect and enhance 3,501 acres of riparian and instream habitat.

13 HYDRO ENERGY↗

The role of thermal energy storage in industrial energy conservation

Thermal Energy Storage for Industrial Applications is a major thrust of the Department of Energy's Thermal Energy Storage Program. Utilizing Thermal Energy Storage (TES) with process or reject heat recovery systems is shown to be extremely beneficial for several applications. Recent system studies resulting from contracts awarded by the Department of Energy (DOE) identified four especially significant industries where TES appears attractive - food processing, paper and pulp, iron and steel, and cement. Potential annual fuel savings with large scale implementation of near term TES systems for these industries is over 9,000,000 bbl of oil. This savings is due to recuperation and storage in the food processing industry, direct fuel substitution in the paper and pulp industry and reduction in electric utility peak fuel use through inplant production of electricity from utilization of reject heat in the steel and cement industries.

Duscha, R. A.↗

Vertical Axis Wind Turbine (VAWT) with Thermoplastic Composite Blades

Rising concerns about global climate change, planet pollution and increasing use of energy have accelerated wider utilization of renewable energy sources. A recent trend in energy system development is decentralization of power generation systems. The opportunity for individuals or organizations to generate electricity locally decreases losses and part of the electricity price caused by the long-distance power transmission. Vertical axis wind turbines (VAWTs) cannot compete with traditional horizontal axis wind turbines (HAWTs) on the basis of aerodynamic performance or maximum power output generated for a given footprint. However, their ability to perform at a wide range of wind speeds, indifference to wind direction, simplicity of fabrication, transportability and maintainability make them ideal candidates for decentralized installations in urban and residential areas. The project team including Steelhead Composites (SHC), Colorado State University (CSU), National Renewable Energy Laboratory (NREL) and Arkema Inc. designed and fabricated a VAWT rotor assembly with thermoplastic composite blades using novel infusion and fabrication techniques. This full-scale VAWT rotor assembly was designed for a rated power output of 0.5-1 kW, as estimated through analytical computational fluid dynamics (CFD) methods. Those CFD simulations were combined with structural finite element analysis (FEA) to optimize the shape and composite layup of the wind blades. Much of the emphasis of this program was to characterize the recyclable thermoplastic material and composite structural design, in order to take full advantage of the material properties of such composites. Additionally, this project examined the potential of thermoplastic resin systems to transform the way VAWT rotor assemblies are joined both in the factory in in the field, by utilizing thermally welded joints to minimize field failure. The infused composite blades manufactured during this program are an excellent example of these benefits made possible by the Arkema thermoplastic resin system. This prototype blade manufacturing also provided the groundwork to inform decisions for larger scale manufacturing techniques applicable to a commercialization strategy. There is specific commercial interest for small scale VAWT’s that are competitively priced, perform to expectations, and have environmentally conscious end-of-life characteristics. Economic analysis was also conducted to compare designs and material usage, providing an estimated levelized cost of energy (LCOE) for the VAWT. The next steps for commercialization would include testing of the rotor assembly to verify predicted performance, specification of the balance of plant components (generator, inverter, etc.), and identification of a manufacturing partner with capability to scale-up production. This program has showed the potential for a commercially viable product through detailed analysis, material characterization and prototype fabrication.

17 WIND ENERGY↗

Fort Yukon wood Energy Program Wood Boiler Deployment (Final Report)

The Fort Yukon Gwitchyaa Zhee Corporation (GZ) worked with partners on the development of an Integrated Biomass Energy Program for Fort Yukon. This integrated approach linked sustainable forest management with an in- village for -profit wood harvest and delivery business to displace diesel energy with wood energy for heat and power. The program was based on the concept of ecological, economic and social sustainability with a goal of displacing as much diesel and fuel oil as is technically feasible and sustainable; essentially systematically converting a village to significant amounts of wood use. Additionally, GZ worked with the Alaska Energy Authority (AEA) on the development of a rural power system upgrade (RPSU) project that replaced GZ’s existing antiquated diesel power plant and provided upgrades to the existing electrical distribution system. Due to the synergy of the two projects, the Biomass and RPSU projects were combined to provide improved operating efficiency, economy of scale and increased benefits to GZ, the Council of Athabascan Tribal Governments (CATG) and the community of Fort Yukon. The combined project is referred to as the Fort Yukon Combined heat and power (CHP) project. The purpose of the DOE Tribal Energy Program award was to support the preconstruction tasks and installation of wood boilers at the CATG clinic, and at the new GZ diesel power plant as part of an overall program to create a for- profit wood energy utility in Native Village of Fort Yukon. The CHP project provides biomass and diesel generation recovered heat via a new district heating system to the major commercial buildings in Fort Yukon. The CATG clinic will receive heat from a separate biomass boiler to their heating needs. The award from the Department of Energy (DOE) Tribal Energy Program was divided into two phases: Design/Permitting (phase 1) and Construction (phase 2). Phase 1 (Design & Permitting) is cost shared using State of Alaska Renewable Energy Funding (REF) funds through the Alaska Energy Authority (AEA). Phase 2 (Construction) was funded by DOE, AEA and US Department of Agriculture Rural Utility Service (USDA-RUS). Phase 1 of this grant, along with a separate grant from the Denali Commission provided funding for development of the wood delivery infrastructure necessary to support the CHP project. Under phase 2, This DOE grant supported final design of the boiler, bidding, purchase and transport of boilers, installation, technical support and engineering. The AEA and RUS grants supported permitting, final design, material and equipment purchase, and construction and installation of the new diesel power plant and district heating distribution system.

09 BIOMASS FUELS↗

Simulative Prediction of Solar Illuminance and Application of the Du-Sharples Model in Estimating Adapted Daylighting Metrics for an Urban Environment

The practice of daylighting in indoor spaces can significantly reduce electricity consumption and carbon emissions, improve human productivity, and enhance mood and cognitive perception. This work discussed the recent developments in daylighting science and practice, computed the periodic variations in average diurnal daylight levels for each month, quantified in terms of global horizontal illuminance and diffuse horizontal illuminance, for Kolkata, India, a city with tropical wet and dry climate, with two empirical luminous efficacy models of estimating solar illuminance, and assessed daylighting metrics with the Du-Sharples model. A program was formulated that could compute and generate daylight data with monthly-hourly solar irradiation data and the Du-Sharples model was utilized to predict dirt-corrected daylighting metrics for three glazing transmittance values and five elemental carbon deposition levels on glazing material. The highest monthly average global horizontal illuminance is recorded in April (64.05 klx for Littlefair model and 66.82 klx for Muneer-Kinghorn model) and the highest monthly average diffuse horizontal illuminance is recorded in July (33.23 klx for Littlefair model and 30.63 klx for Muneer-Kinghorn model). Further, the computed yearly average global and diffuse horizontal illuminance levels agree well with a previous study that applied the Perez model. Yearly average horizontal work surface illuminance level remained >1.5 klx for window-towall area ratio >30 %. The approach adopted in this work and the temporal variation charts of computed exterior daylight level data may assist building service engineers, architects, and indoor lighting practitioners in making informed policy decisions at different stages of building planning.

Engineering↗

Refractory metal alloys and composites for space nuclear power systems

Space power requirements for future NASA and other U.S. missions will range from a few kilowatts to megawatts of electricity. Maximum efficiency is a key goal of any power system in order to minimize weight and size so that the Space Shuttle may be used a minimum number of times to put the power supply into orbit. Nuclear power has been identified as the primary power source to meet these high levels of electrical demand. One method to achieve maximum efficiency is to operate the power supply, energy conservation system, and related components at relatively high temperatures. For systems now in the planning stages, design temperatures range from 1300 K for the immediate future to as high as 1700 K for the advanced systems. NASA Lewis Research Center has undertaken a research program on advanced technology of refractory metal alloys and composites that will provide baseline information for space power systems in the 1900's and the 21st century. Special emphasis is focused on the refractory metal alloys of niobium and on the refractory metal composites which utilize tungsten alloy wires for reinforcement. Basic research on the creep and creep-rupture properties of wires, matrices, and composites are discussed.

Titran, Robert H.↗

It's All About the Envelope: Prioritizing Envelope Upgrades for Electrification of Cold Climate Homes

Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.

air sealing↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Home Performance with ENERGY STAR: Utility Bill Analysis on Homes Participating in Austin Energy's Program

Home Performance with ENERGY STAR (HPwES) is a jointly managed program of the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA). This program focuses on improving energy efficiency in existing homes via a whole-house approach to assessing and improving a home's energy performance, and helping to protect the environment. As a local sponsor for HPwES, Austin Energy's HPwES program offers a complete home energy assessment and a list of recommendations for efficiency improvements, along with cost estimates. The owner can choose to implement only one or the complete set of energy conservation measures. Austin Energy facilitates the process by providing economic incentives to the homeowner through its HPwES Loan program and its HPwES Rebate program. In 2005, the total number of participants in both programs was approximately 1,400. Both programs are only available for improvements made by a participating HPwES contractor. The individual household billing data - encompassing more than 7,000 households - provided by Austin Energy provides a rich data set to estimate the impacts of its HPwES program. The length of the billing histories is sufficient to develop PRISM-type models of electricity use based on several years of monthly bills before and after the installation of the conservation measures. Individual household savings were estimated from a restricted version of a PRISM-type regression model where the reference temperature to define cooling (or heating degree days) was estimated along with other parameters. Because the statistical quality of the regression models varies across individual households, three separate samples were used to measure the aggregate results. The samples were distinguished on the basis of the statistical significance of the estimated (normalized) cooling consumption. A normalized measure of cooling consumption was based on average temperatures observed over the most recent nine-year period ending in 2006. This study provided a statistically rigorous approach to incorporating the variability of expected savings across the households in the sample together with the uncertainty inherent in the regression models used to estimate those savings. While the impact of the regression errors was found to be relatively small in these particular samples, this approach may be useful in future studies using individual household billing data. The median percentage savings for the largest sample of 6,000 households in the analysis was 32%, while the mean savings was 28%. Because the number of households in the sample is very large, the standard error associated with the mean percentage savings are very small, less than 1%. A conservative statement of the average savings is that is falls in the range of 25% to 30% with a high level of certainty. This preliminary analysis provides robust estimates of average program savings, but offers no insight into how savings may vary by type of conservation measure or whether savings vary by the amount of cooling electricity used prior to undertaking the measure. Follow-up researchers may want to analyze the impacts of specific ECMs. Households that use electricity for heating might also be separately analyzed. In potential future work several methodological improvements could also be explored. As mentioned in Section 2, there was no formal attempt to clean the data set of outliers and other abnormal patterns of billing data prior to the statistical analysis. The restriction of a constant reference temperature might also be relaxed. This approach may provide evidence as to whether any 'take-back' efforts are present, whereby thermostat settings are lowered during the summer months after the measures are undertaken (reflected in lower reference temperatures in the post-ECM period). A more extended analysis may also justify the investment in and use of the PRISM software package, which may provide more diagnostic measures with respect to the reference temperature. PRISM also appears to contain some built-in capability to detect outliers and other anomalous data points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

Investigation of Donor and Acceptor Ion Implantation in AlN

AlGaN alloys with high Al composition and AlN based electronic devices are attractive for high voltage, high temperature applications, including microwave power sources, power switches and communication systems. AlN is of particular interest because of its wide bandgap of ~6.1eV which is ideal for power electronic device applications in extreme environments which requires high dose ion implantation. One of the major challenges that need to be addressed to achieve full utilization of AlN for opto and microelectronic applications is the development of a doping strategy for both donors and acceptors. Ion implantation is a particularly attractive approach since it allows for selected-area doping of semiconductors due to its high spatial and dose control and its high throughput capability. Active layers in the semiconductor are created by implanting a dopant species followed by very high temperature annealing to reduce defects and thereby activate the dopants. Recovery of implant damage in AlN requires excessively high temperature. In this SBIR program we began the investigation by simulation of ion beam implantation profiles for Mg, Ge and Si in AlN over wide dose and energy ranges. Si and Ge are implanted to achieve the n-type doping, Mg is investigated as a p-type doping. The simulation of implantation profiles were performed in collaboration between NRL and Agnitron using a commercial software known as Stopping and Range of Ions in Matter (SRIM). The simulation results were then used as the basis for ion implantation of AlN samples. The implanted samples were annealed by an innovative technique under different conditions and evaluated along the way. Raman spectroscopy and XRD were used to determine the crystal quality of the implanted samples, demonstrating the effectiveness of annealing in removing implant induced damage. Additionally, SIMS was used to verify that a nearly uniform doping profile was achieved near the sample surface. The electrical characteristics of the implanted samples were evaluated by TLM and Hall techniques. Generally, the implanted samples before and after annealing were found to be very resistive. Further work is required before the superior properties of AlN can be fully utilized.