Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

DQE of wireless digital detectors: Comparative performance with differing filtration schemes

Purpose: Wireless flat panel detectors are gaining increased usage in portable medical imaging. Two such detectors were evaluated and compared with a conventional flat-panel detector using the formalism of the International Electrotechnical Commission (IEC 62220-1) for measuring modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) using two different filtration schemes.Methods: Raw images were acquired for three image receptors (DRX-1C and DRX-1, Carestream Health; Inc., Pixium 4600, Trixell) using a radiographic system with a well-characterized output (Philips Super80 CP, Philips Healthcare). Free in-air exposures were measured using a calibrated radiation meter (Unfors Mult-O-Meter Type 407, Unfors Instruments AB). Additional aluminum filtration and a new alternative combined copper-aluminum filtration were used to conform the x ray output to IEC-specified beam quality definitions RQA5 and RQA9. Using the IEC 62220-1 formalism, each detector was evaluated at X{sub N}/2, X{sub N}, and 2X{sub N}, where the normal exposure level to the detector surface (X{sub N}) was set to 8.73 μGy (1.0 mR). The prescribed edge test device was used to evaluate the MTF, while the NNPS was measured using uniform images. The DQE was then calculated from the MTF and NNPS and compared across detectors, exposures, and filtration schemes.Results: The three DR systems had largely comparable MTFs with DRX-1 demonstrating lower values above 1.0 cycles/mm. At each exposure, DRX-1C and Pixium detectors demonstrated better noise performance than that of DRX-1. Zero-frequency DQEs for DRX-1C, Pixium, and DRX-1 detectors were approximately 74%, 63%, and 38% for RQA5 and 50%, 42%, and 28% for RQA9, respectively.Conclusions: DRX-1C detector exhibited superior DQE performance compared to Pixium and DRX-1. In terms of filtration, the alternative filtration was found to provide comparable performance in terms of rank ordering of different detectors with the added convenience of being less bulky for in-the-field measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Cooling of a mirror in cavity optomechanics with a chirped pulse

We investigate the response of a harmonically confined mirror to an optical pulse in cavity optomechanics. We show that when the pulsed coupling strength takes the form of a chirped pulse, thermal fluctuations of the mirror can be significantly transferred to the cavity field. In addition, the frequency modulation of the pulse could enable a better cooling performance by suppressing the sensitivity of the dependence of detuning and pulse areas. Using numerical investigations, we find that the pulsed cooling is mainly limited by the cavity-field decay rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method for eliminating Faraday rotation in cryostat windows in longitudinal magneto-optical Kerr effect measurements

A solution to the problem of disturbing effect of the background Faraday rotation in the cryostat windows on longitudinal magneto-optical Kerr effect (LMOKE) measured under vacuum conditions and/or at low temperatures is proposed. The method for eliminating the influence of Faraday rotation in cryostat windows is based on special arrangement of additional mirrors placed on sample holder. In this arrangement, the orientation of the cryostat window is perpendicular to the light beam direction and parallel to an external magnetic field generated by the H-frame electromagnet. The operation of the LMOKE magnetometer with the special sample holder based on polarization modulation technique with a photo-elastic modulator is theoretically analyzed with the use of Jones matrices, and formulas for evaluating of the actual Kerr rotation and ellipticity of the sample are derived. The feasibility of the method and good performance of the magnetometer is experimentally demonstrated for the LMOKE effect measured in Fe/Au multilayer structures. The influence of imperfect alignment of the magnetometer setup on the Kerr angles, as derived theoretically through the analytic model and verified experimentally, is examined and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics Demonstration of Temperature-Driven Assembly Bowing in SFRs using MOOSE-Based Codes

Core bowing is an important passive safety mechanism in liquid metal cooled fast reactors. When the core restraint system is properly designed, temperature and flux gradients influence assemblies in the core to bow into less reactive configurations during accident scenarios, resulting in negative reactivity feedback. Prediction of core bowing involves complex interplay of radiation transport, impacts of fluid flow and heat transfer on duct temperature, and mechanical responses to the induced temperature and flux gradients. Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program [1], an integrated multiphysics approach is being developed to model the core bowing phenomena in liquid metal-cooled fast reactors with the Multiphysics Object Oriented Simulation Environment (MOOSE) [2]. In this methodology, the MOOSE-based reactor physics code Griffin [3] will solve the neutron transport equation and determine the power distribution. With the detailed power distribution from Griffin, the subchannel analysis codes MOOSE-Subchannel [4] and Pronghorn [5] are utilized to calculate the assembly temperature distribution. MOOSE’s Solid Mechanics [6] and Contact [7] Modules are leveraged to calculate the thermal expansion and duct bowing displacement with the duct wall temperature from thermal hydraulics calculation. In this work, an initial one-way coupling demonstration of the integrated multiphysics approach has been performed on a seven-assembly problem based on the sodium-cooled fast reactor ABR-1000 design [8]. The neutronics calculation with Griffin is not yet involved in the current simulation. MOOSE-Subchannel and Pronghorn evaluate fluid and solid temperature based on a fixed power distribution. In addition, one-way coupling is utilized in this coupled calculation, via Pronghorn passing the duct temperature data to the MOOSE Solid Mechanics calculation. An assessment of the Solid Mechanics module was performed in parallel to verify duct bowing behavior with duct-to-duct contact phenomenon [9]. The displacement from MOOSE Solid Mechanics is not yet transferred back and utilized in the Pronghorn and MOOSE-Subchannel calculation. This model will be available on the National Reactor Innovation Center (NRIC) Virtual Test Bed (VTB) repository [10]. Future stages of this work will involve solving problems of increasing complexity as well as adding more physics (e.g. reactor physics) to the integrated workflow to reach the end goal of modeling the core bowing phenomenon with an integrated multiphysics workflow.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Constructive polarization modulation for coherent population trapping clock

We propose a constructive polarization modulation scheme for atomic clocks based on coherent population trapping (CPT). In this scheme, the polarization of a bichromatic laser beam is modulated between two opposite circular polarizations to avoid trapping the atomic populations in the extreme Zeeman sublevels. We show that if an appropriate phase modulation between the two optical components of the bichromatic laser is applied synchronously, the two CPT dark states which are produced successively by the alternate polarizations add constructively. Measured CPT resonance contrasts up to 20% in one-pulse CPT and 12% in two-pulse Ramsey-CPT experiments are reported, demonstrating the potential of this scheme for applications to high performance atomic clocks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of Melt Flow Rate Test in Reliability Study of Thermoplastic Encapsulation Materials in Photovoltaic Modules

Use of thermoplastic materials as encapsulants in photovoltaic (PV) modules presents a potential concern in terms of high temperature creep, which should be evaluated before thermoplastics are qualified for use in the field. Historically, the issue of creep has been avoided by using thermosetting polymers as encapsulants, such as crosslinked ethylene-co-vinyl acetate (EVA). Because they lackcrosslinked networks, however, thermoplastics may be subject to phase transitions and visco-elastic flow at the temperatures and mechanical stresses encountered by modules in the field, creating the potential for a number of reliability and safety issues. Thermoplastic materials investigated in this study include PV-grade uncured-EVA (without curing agents and therefore not crosslinked);polyvinyl butyral (PVB); thermoplastic polyurethane (TPU); and three polyolefins (PO), which have been proposed for use as PV encapsulation. Two approaches were used to evaluate the performance of these materials as encapsulants: module-level testing and a material-level testing.

14 SOLAR ENERGY↗

Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans

Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented improvements in care for breast cancer patients, using technologies that are widely available and already in clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Silevo Modules at the Regional Test Centers (Cooperative Research and Development Final Report, CRADA Number CRD-15-589)

Silevo and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of Silevo's Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

SIMS analysis of high-performance accelerator niobium

Niobium is used to fabricate superconducting radio frequency accelerator modules because of its high critical temperature, high critical magnetic field, and easy formability. Recent experiments have shown a very significant improvement in performance (over 100%) after a high-temperature bake at 1400 degrees C for 3h. SIMS analysis of this material showed the oxygen profile was significantly deeper than the native oxide with a shape that is indicative of diffusion. Positive secondary ion mass spectra showed the presence of Ti with a depth profile similar to that of O. It is suspected that Ti is associated with the performance improvement. The source of Ti contamination in the anneal furnace has been identified, and a new furnace was constructed without Ti. Initial results from the new furnace do not show the yield improvement. Further analyses should determine the relationship of Ti to cavity performance.

Maheshwari, P.↗

Impact of a Health Information Technology Intervention on the Follow-up Management of Pulmonary Nodules

Lung cancer is the leading cause of cancer deaths in the USA. The most common abnormalities suspicious for lung cancer on CT scan include pulmonary nodules. Recommendations to improve care for patients with pulmonary nodules require follow-up management. However, transitions in care, especially for patients undergoing transitions to ambulatory care sites from the emergency department (ED) and inpatient settings, can exacerbate failures in follow-up testing and compromise patient safety. We evaluate the impact of a discharge module that includes follow-up recommendations for further management of pulmonary nodules on the study outcome and follow-up management of patients with pulmonary nodules within 1 year after discharge. After IRB approval, we collected data on all patients undergoing chest or abdominal CT exams over a 12-month baseline and 12-month intervention period at an academic medical center. The inpatient discharge module was implemented in November 2011; the ED module was implemented in May 2012. Multivariable logistic regression was performed to account for care setting, imaging modality, recommendations, and patient demographics. Implementation of a discharge module resulted in improved follow-up of patients with pulmonary nodules within 1 year after discharge (OR = 1.64, p = 0.01); the ED implementation resulted in better follow-up compared to the inpatient module (OR = 2.24, p < 0.01). Twenty-seven percent of patients with pulmonary nodules received follow-up management, which, although significantly improved from the 18% baseline, remains low. An electronic discharge module is associated with improved follow-up management of patients with pulmonary nodules, and may be combined with interventions to further improve management of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salt matters: How ionic strength and electrolytes impact redox polymer reactivity and dynamics for energy storage

As the global demand for sustainable energy grows, redox-active polymers (RAPs) have emerged as promising materials for batteries due to their advantages in stability, ease of preparation, and low-cost processability. Despite factors traditionally known to impact polymer dynamics (e.g., temperature, viscosity, and structure), we posit that investigating the effect of ionic strength and/or supporting electrolyte types on the electrochemical performance of RAP systems is crucial, both in aqueous and nonaqueous systems. Here, we first highlight recent findings on RAP-electrolyte interactions, elucidating how their polyelectrolyte nature determines their redox activity. Then, we focus on strategies to enhance RAP performance for energy storage through ionic strength optimization and tailored electrolyte composition. These insights into the modulation of RAP reactivity provide a foundation for improving battery performance in both flow and stationary configurations, thus facilitating progress toward next-generation energy storage solutions.

25 ENERGY STORAGE↗

A 200kW central receiver CPV system

Raygen Resources has recently completed a Central Receiver CPV (CSPV) pilot plant in Central Victoria, Australia. The system is under final commissioning and initial operation is expected in late April 2015. The pilot demonstrates a full scale CSPV repeatable unit in a form that is representative of a commercial product and provides a test bed to prove out performance and reliability of the CSPV technology. Extensive testing of the system key components: dense array module, wireless solar powered heliostat and control system has been performed in the laboratory and on sun. Results from this key component testing are presented herein.

14 SOLAR ENERGY↗

Integrated system tests of the LSST raft tower modules

The science focal plane of the LSST camera is made up of 21 fully autonomous 144 Mpixel imager units designated raft tower modules (RTM). These imagers incorporate nine 4K x 4K fully-depleted CCDs and 144 channels of readout electronics, including a dedicated CMOS video processing ASIC and components that provide CCD biasing and clocking, video digitization, thermal stabilization, and a high degree of monitoring and telemetry. Here, the RTM achieves its performance goals for readout speed, read noise, linearity, and crosstalk with a power budget of less than 400mW/channel. Series production is underway on the first units and the production will run until 2018. We present the RTM final design, tests of the integrated signal chain, and performance results for the fully-integrated module with pre-production CCDs.

42 ENGINEERING↗

PACT Module Preconditioning Protocol (V.0.1)

The purpose of this protocol is to bring metal halide perovskite (MHP) modules to a repeatable and relevant state prior to making a performance measurement. Performance measurements are made before and after a stressor has been applied to the module to quantify the degree of loss resulting from the stressor. This procedure is intended to be carried out both before and after the accelerated test.

14 SOLAR ENERGY↗

Multifunctional Thiol-Containing Additives for Improved Photoluminescence and Photovoltaic Performance of Cs 0.15 FA 0.85 PbI 3 Perovskites

Thiol containing molecules as both interfacial surface ligands and additives are promising modulators for enhancing photoluminescence (PL) properties, stability, and photovoltaic (PV) performance of metal halide perovskites. However, alkanethiols are much more effective for improving photoluminescence (PL) intensity and stability in metal halide perovskite nanocrystals than in their thin film analogues. Herein, we investigate how additional functional groups on a pyrimidine core can alter thiol reactivity and influence the PL, stability, and PV performance of organic metal halide perovskites. Through an investigation of five different pyrimidine derivatives, it is shown that all derivatives containing thiol groups form thiolates in the presence of the perovskite precursors and increase the photoluminescence intensity of the perovskite film. The largest all-around improvement to the PL intensity, stability, and photovoltaic performance of Cs 0.15 FA 0.85 PbI 3 perovskites is realized through the addition of a hydroxyl group combined with a trifluoromethyl group to form 4-hydroxy-6-(trifluoromethyl)pyrimidine-2-thiol. Furthermore, this investigation helps illuminate how combinations of functional groups can be employed to further increase the beneficial effects over monofunctional additives in organic metal halide perovskites.

14 SOLAR ENERGY↗