Search NASA⌕ Search

SEARCH · Search NASA

Results for “proposal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Error Correction: a Proposal for a Standard

Some of the errors in transducers such as instrument transformers can be corrected as part of the digital processing for the measurement. The transducer can be characterized on such a way that allows the TEDS of IEEE Std 1451 to transfer the information to the measurement system. A modification would allow the measurement system to perform a high-quality self-calibration whenever a transducer was replaced.

error correction.↗

Proposing Measures of Flicker in the Low Frequencies for Lighting Applications

The IEEE Standards Working Group, IEEE P1789 'Recommending practices for modulating current in High Brightness LEDs for mitigating health risks to viewers' has been formed to advise the lighting industry, ANSI/NEMA, IEC, EnergyStar and other standards groups about the emerging concern of flicker in LED lighting. This paper intends to introduce new measures and definitions of lamp flicker in lighting. The discussion represents on-going work in IEEE P1789 that is vital to designing safe LED lamp drivers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fatigue-Like Behavior of Silver Metallization Gridlines and Proposed Damage Mechanics Model

In this work, we present a novel method to evaluate the fracture and fatigue-like behavior of crystalline silicon PV cell metallization. Initial results demonstrate that silver metal gridlines are capable of bridging a ~10–20 µm gap prior to becoming electrically open and do demonstrate fatigue-like behavior under cyclic straining conditions. This later phenomenon was well fit with a traditional power law equation for high cycle fatigue and enabled the development of a damage mechanics model for gridline failure.

41 EE - Solar Energy Technologies Office (EE-4S)↗

RF transient analysis and stabilization of the phase and energy of the proposed PIP-II LINAC

Here, this paper describes a recent effort to develop and benchmark a simulation tool for the analysis of RF transients and their compensation in an H- linear accelerator. Existing tools in this area either focus on electron LINACs or lack fundamental details about the LLRF system that are necessary to provide realistic performance estimates. In our paper we begin with a discussion of our computational models followed by benchmarking with existing beam-dynamics codes and measured data. We then analyze the effect of RF transients and their compensation in the PIP-II LINAC, followed by an analysis of calibration errors and how a Newton’s Method based feedback scheme can be used to regulate the beam energy to within the specified limits.

43 PARTICLE ACCELERATORS↗

The IEEE Reliability Test System: A Proposed 2019 Update

The evolving nature of electricity production, transmission and consumption necessitates an update to the IEEE's Reliability Test System, which was last modernized in 1996. The update introduced here introduces a generation mix more representative of modern power systems, with the removal of several nuclear and oil generating units and the addition of natural gas, wind, solar photovoltaics, concentrating solar power, and energy storage. The update includes assigning the test system a geographic location in the southwestern United States to enable the integration of spatio-temporally consistent wind, solar, and load data with forecasts. Further updates include common RTS transmission modifications in published literature, definitions for reserve product requirements and market simulation descriptions to enable benchmarking of multi-period power system scheduling problems. The final section reflects example results from a production cost modeling simulation on the updated RTS system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Proposals for FAIR, Automated, Recommendable, and Robust Workflows

Lightning talks of the Workflows in Support of Large-Scale Science (WORKS) workshop are a venue where the workflow community (researchers, developers, and users) can discuss work in progress, emerging technologies and frameworks, and training and education materials. This paper summarizes the WORKS 2022 lightning talks, which cover five broad topics: data integrity of scientific workflows; a machine learning-based recommendation system; a Python toolkit for running dynamic ensembles of simulations; a cross-platform, high-performance computing utility for processing shell commands; and a meta(data) framework for reproducing hybrid workflows.

Abhinit, Ishan↗

A Proposal of Conducting Bioequivalence Trials with Gastric pH Modulators for Two Oral Formulations Demonstrating Different Dissolution Profiles at Elevated pH

In this paper, a special case for bioequivalence evaluation of oral formulations is discussed. Drug formulations with different forms of active moieties (e.g., free base and salt) may yield different dissolution characteristics and, thus, differ in absorption at elevated gastric pH . However, routine bioequivalence trials using subjects with normal gastric pH (i.e., ~ 1) may fail to identify these differences because dissolution/absorption profiles of the two formulations at normal gastric pH are similar. In the case of palbociclib, it is confirmedthat the free base and salt formulations showed different absorption in patients with different gastric pH . Significant reduction in drug absorption was observed only in patients with elevated gastric pH using free base formulation. The discovery that the free base had significantly reduced absorption hinged on the inclusion of enough patients with elevated gastric pH to detect a difference in a bioequivalence trial. This raises a concern, as demonstrated through simulation, that dissolution/absorption differences in other formulations could be missed in routine bioequivalence trials. Aside from differences in active pharmaceutical ingredients ( API s), other factors, such as changes in excipients or manufacturing methods, may also lead to exposure differences between formulations at elevated gastric pH . For formulations containing different forms of the same active moiety or the same API and showing different dissolution profiles at elevated pH (i.e., pH ~ 4–6.8), evaluation of bioequivalence with gastric pH modulators (e.g., a H 2 blocker) in addition to routine bioequivalence assessments may help to ensure therapeutic equivalence in patients with elevated gastric pH .

59 BASIC BIOLOGICAL SCIENCES↗

Structure and proposed mechanism of α-glycerophosphate oxidase from Mycoplasma pneumoniae

In this study, the formation of hydrogen peroxide (H₂O₂) by the FAD-dependent α-glycerophosphate oxidase (GlpO), is important for the pathogenesis of Streptococcus pneumoniae and Mycoplasma pneumoniae . The structurally known GlpO from Streptococcus sp. ( Ssp GlpO) is similar to the pneumococcal protein ( Sp GlpO) and provides a guide for drug design against that target. However, M. pneumoniae GlpO ( Mp GlpO), having <20% sequence identity with structurally known GlpOs, appears to represent a second type of GlpO we designate as Type II GlpOs. Here, the recombinant His-tagged Mp GlpO structure is described at ~2.5 Å resolution, solved by molecular replacement using as a search model the Bordetella pertussis protein 3253 (Bp3253) a protein of unknown function solved by structural genomics efforts. Recombinant Mp GlpO is an active oxidase with a turnover number of ~580 min⁻¹ while Bp3253 showed no GlpO activity. No substantial differences exist between the oxidized and dithionite-reduced Mp GlpO structures. Although, no liganded structures were determined, a comparison with the tartrate-bound Bp3253 structure and consideration of residue conservation patterns guided the construction of a model for α-glycerophosphate (Glp) recognition and turnover by Mp GlpO. The predicted binding mode also appears relevant for the type I GlpOs (such as Ssp GlpO) despite differences in substrate recognition residues, and it implicates a histidine conserved in type I and II Glp oxidases and dehydrogenases as the catalytic acid/base. This work provides a solid foundation for guiding further studies of the mitochondrial Glp dehydrogenases as well as for continued studies of M. pneumoniae and S. pneumoniae glycerol metabolism and the development of novel therapeutics targeting Mp GlpO and Sp GlpO.

59 BASIC BIOLOGICAL SCIENCES↗

Proposed Material Properties, Allowable Stresses, and Design Curves of Diffusion Bonded Alloy 800H for the ASME Code Section III Division 5

Abstract Increased interest in compact heat exchangers (CHXs) to serve as intermediate heat exchangers of very high temperature reactors resulted in significant research and development on their design, analysis, and construction. Printed circuit heat exchangers are a type of CHXs with high thermal efficiency and compactness achieved through diffusion bonding a stack of etched plates with millimeter scaled channels. The diffusion bonding process changes the microstructural and mechanical properties of the wrought metal plates. The current nonnuclear design code ASME section VIII, division 1 captures the material property change through a “joint efficiency factor.” However, the current nuclear design code ASME section III, division 5 does not address or support the diffusion bonded material properties. Hence, there is a need to develop allowable stresses, isochronous curves, and fatigue life curves for various diffusion bonded alloys. In this study, Alloy 800H material was selected to establish the diffusion bonded material properties under tension, creep, fatigue, and creep-fatigue loads at elevated temperatures in the range 550–760 °C. A set of tests on diffusion bonded Alloy 800H (DB 800H) were performed and the acquired data are used in developing allowable stresses Sy, Su, Sr, Sm, St, Smt, So, isochronous curves and fatigue life curves according to the ASME section III, division 5 requirements. This paper also presents detailed procedures used in developing the ASME code section III division 5 design provisions for diffusion bonded Alloy 800H.

Engineering↗

TU-D-201-03: Proposed Solutions to End-Of-Life Issue

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

SU-F-T-47: MRI T2 Exclusive Based Planning Using the Endocavitary/interstitial Gynecological Benidorm Applicator: A Proposed TPS Library and Preplan Efficient Methodology

Purpose: ABS and GEC-ESTRO have recommended MRI T2 for image guided brachytherapy. Recently, a new applicator (Benidorm Template, TB) has been developed in our Department (Rodriguez et al 2015). TB is fully MRI compatible because the Titanium needles and it allows the use of intrauterine tandem. Currently, TPS applicators library are not currently available for non-rigid applicators in case of interstitial component as the TB.The purpose of this work is to present the development of a library for the TB, together with its use on a pre-planning technique. Both new goals allow a very efficient and exclusive T2 MRI based planning clinical TB implementation. Methods: The developed library has been implemented in Oncentra Brachytherapy TPS, version 4.3.0 (Elekta) and now is being implemented on Sagiplan v 2.0 TPS (Eckert&Ziegler BEBIG). To model the TB, free and open software named FreeCAD and MeshLab have been used. The reconstruction process is based on three inserted A-vitamin pellets together with the data provided by the free length. The implemented preplanning procedure is as follow: 1) A MRI T2 acquisition is performed with the template in place just with the vaginal cylinder (no uterine tube nor needles). 2) The CTV is drawn and the required needles are selected using a developed Java based application and 3) A post-implant MRI T2 is performed. Results: This library procedure has been successfully applied by now in 25 patients. In this work the use of the developed library will be illustrated with clinical examples. The preplanning procedure has been applied by now in 6 patients, having significant advantages: needle depth estimation, needle positions and number are optimized a priori, time saving, etc Conclusion: TB library and pre-plan techniques are feasible and very efficient and their use will be illustrated in this work.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Proposal for chiral-boson search at LHC via their unique new signature

The resonance production of new chiral spin-1 bosons and their detection through the Drell-Yan process at the CERN LHC is considered. Quantitative evaluations of various differential cross sections of the chiral-boson production are made within the CalcHEP package. The new neutral chiral bosons can be observed as a Breit-Wigner resonance peak in the invariant-dilepton-mass distribution, as usual. However, unique new signatures of the chiral bosons exist. First, there is no Jacobian peak in the lepton transverse-momentum distribution. Second, the lepton angular distribution in the Collins-Soper frame for the high on-peak invariant masses of the lepton pairs has a peculiar 'swallowtail' shape.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proposed wavelength measurements of silicon X-ray spectra: Application to Vela X-1

When a stellar wind from a massive star is captured by a neutron star in close orbit, gravitational potential energy is converted into hard X-radiation near the surface of the neutron star. The X-radiation, in turn, modifies the wind through heating and photoionization, which affects the dynamics of mass capture. We have begun a project to further elucidate this process, which involves time-dependent three-dimensional hydrodynamics, large-scale atomic physics calculations, and radiation transport, integrated in an attempt to derive a self-consistent “first principles” description of the mass transfer process. Additionally, we anticipate that the high-resolution silicon X-ray spectrum, produced by innershell photoionization and photoexcitation, as measured by the Chandra observatory, will provide benchmarks for these calculations. However, theoretical wavelengths, which are required in order to draw inferences concerning the velocity field of the wind, are uncertain at the level of the likely Doppler shifts in the stellar wind. EBIT measurements could lead to a reliable set of wavelengths, thereby providing observational constraints on the physics that powers some of the brightest X-ray sources in the Galaxy. PACS Nos.: 32.30.Rj, 32.80.Fb, 32.80.Hd, 52.25.Os, 52.72.+v, 97.10.Me, 97.80.Jp

74 ATOMIC AND MOLECULAR PHYSICS↗

Comments on : Proposal for Raman x-ray free electron laser.

Equation 13 in this paper defines the force experienced by the electron moving in z direction with velocity v{sub z} due to the X-ray wave propagating in z direction with electric field E{sub 1} pointing in y direction and magnetic field B{sub 1} pointing in x direction as {rvec F}{sub 1}(t) = -eE{sub 1} cos({omega}{sub 1}t - k{sub 1}z){rvec e}{sub y}. In our opinion calculating this force one should also include the impact of the X-ray wave's magnetic field and obtain {rvec F}{sub 1}(t) = -e E{sub 1} = v{sub z}/c B{sub 1} cos({omega}{sub 1}t - k{sub 1}z){rvec e}{sub y} {approx} - eE{sub 1}/2{gamma}{sup 2} cos({omega}{sub 1}t - k{sub 1}z){rvec e}{sub y}. Here c is the speed of light and {gamma} is the electron relativistic factor. In result one would need to change E{sub 1} to E{sub 1}/2{gamma}{sup 2} in all the following equations in the cited paper (except wave propagation equations, Eqs. (23) and (34)). They believe that similar omission in the impact of the magnetic field appears in equation (28). Consequently, the formula for the gaion (Eq. (37) in the cited paper) should also include the factor 1/2{gamma}{sup 2}. This is a rather significant modification considering that relativistic electrons with values of {gamma} ranging from approximately 20 to approximately 300 are used in the numerical examples.

43 PARTICLE ACCELERATORS↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗

Echelle spectrograph calibration with a frequency comb based on a harmonically mode-locked fiber laser: a proposal

Details for constructing an astronomical frequency comb suitable as a wavelength reference for echelle spectrographs associated with optical telescopes are outlined. The source laser for the frequency comb is a harmonically mode-locked fiber laser with a central wavelength of 1.56 {mu}m. The means of producing a repetition rate greater than 7 GHz and a peak optical power of {approx}8 kW are discussed. Conversion of the oscillator light into the visible can occur through a two-step process of (i) nonlinear conversion in periodically poled lithium niobate and (ii) spectral broadening in photonic crystal fiber. While not necessarily octave spanning in spectral range to permit the use of an f -to- 2f interferometer for offset frequency control, the frequency comb can be granted accuracy by linking the mode spacing and a comb tooth to separate frequency references. The design avoids the use of a Fabry-Perot cavity to increase the mode spacing of the frequency comb; however, the level of supermode suppression and sideband asymmetry in the fiber oscillator and in the subsequent frequency conversion stages are aspects that need to be experimentally tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗