Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of scat detection methods for a social ungulate, the wild pig, and experimental evaluation of factors affecting detection of scat

Collection of scat samples is common in wildlife research, particularly for genetic capture-mark-recapture applications. Due to high degradation rates of genetic material in scat, large numbers of samples must be collected to generate robust estimates. Optimization of sampling approaches to account for taxa-specific patterns of scat deposition is, therefore, necessary to ensure sufficient sample collection. While scat collection methods have been widely studied in carnivores, research to maximize scat collection and noninvasive sampling efficiency for social ungulates is lacking. Further, environmental factors or scat morphology may influence detection of scat by observers. We contrasted performance of novel radial search protocols with existing adaptive cluster sampling protocols to quantify differences in observed amounts of wild pig ( Sus scrofa ) scat. We also evaluated the effects of environmental (percentage of vegetative ground cover and occurrence of rain immediately prior to sampling) and scat characteristics (fecal pellet size and number) on the detectability of scat by observers. We found that 15- and 20-m radial search protocols resulted in greater numbers of scats encountered than the previously used adaptive cluster sampling approach across habitat types, and that fecal pellet size, number of fecal pellets, percent vegetative ground cover, and recent rain events were significant predictors of scat detection. Our results suggest that use of a fixed-width radial search protocol may increase the number of scats detected for wild pigs, or other social ungulates, allowing more robust estimation of population metrics using noninvasive genetic sampling methods. Further, as fecal pellet size affected scat detection, juvenile or smaller-sized animals may be less detectable than adult or large animals, which could introduce bias into abundance estimates. In conclusion, knowledge of relationships between environmental variables and scat detection may allow researchers to optimize sampling protocols to maximize utility of noninvasive sampling for wild pigs and other social ungulates.

59 BASIC BIOLOGICAL SCIENCES↗

A novel digitization scheme with FPGA-base TDC for beam loss monitors operating at cryogenic temperature

Recycling integrators are common current-to-frequency converting circuits for measurements of low current such as that produced by Fermilab's cryogenic ionization chambers. In typical digitization/readout schemes, a counter is utilized to accumulate the number of pulses generated by the recycling integrator to adequately digitize the total charge. In order to calculate current with reasonable resolution (e.g., 7-8 bits), hundreds of pulses must be accumulated which corresponds to a long sampling period, i.e., a very low sampling rate. In our new scheme, an FPGA-based Time-to-Digital Convertor (TDC) is utilized to measure the time intervals between the pulses output from the recycling integrator. Using this method, a sample point of the current can be made with good resolution (>10 bits) for each pulse. This effectively increases the sampling rates by hundreds of times for the same recycling integrator front-end electronics. This scheme provides a fast response to the beams loss and is potentially suitable for accelerator protection applications. Moreover, the method is also self-zero-suppressed, i.e., it produces more data when the beam loss is high while it produces significantly less data when the beam loss is low.

43 PARTICLE ACCELERATORS↗

The impact of sampling scale: A comparison of methods for estimating external contaminant exposure in free-ranging wildlife

The impacts of contaminants on wildlife are dose dependent, and thus being able to track or predict exposure following contamination events is important for monitoring ecosystem health. However, the ability to track exposure in free-ranging wildlife is often severely limited. Consequently, researchers have predominantly relied on simple methods for estimating contaminant exposures in wildlife with little regard for spatial contaminant heterogeneity or an animal’s use of diverse habitats. We evaluated the influence sampling scale (i.e., how finely contaminant distribution and organism’s spatial use of the landscape is mapped) has on (1) realism and (2) conservativeness of exposure estimates. To do this, we monitored the actual exposure of wild boar (Sus scrofa) in Fukushima, Japan to radioactive contamination using GPS27 coupled contaminant monitors placed on individual animals. We compared empirical exposures to estimates generated by combining varying amounts of information about an individual boar’s location and/or movement, with the distribution of contamination on the landscape. Here we found that the most realistic exposure estimates were produced when finer-scale contaminant distribution surveys (e.g., airborne surveys) were combined with more accurate estimates of an individual’s space use (e.g., home ranges or core areas). Importantly, estimates of exposure based on single point surveys at a trap site (a simple method commonly used in the literature), did not correlate with actual exposure rates, suggesting dose-effects studies using this method may result in spurious conclusions. These results suggest that researchers seeking realistic estimates of exposure, such as in dose-effect studies, should ensure they have adequately accounted for fine-scale contaminant distribution patterns and areas of higher use by study organisms. However, conservative estimates of exposure i.e., intentionally over-predicting exposure as is done in initial tiers of ecological risk analyses) were not as scale sensitive and could be achieved with a single known location and coarse contaminant distribution maps.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Curie temperature enhancement in partially disordered Sr{sub 2}FeReO{sub 6} double perovskites

Two samples of the double perovskite Sr{sub 2}FeReO{sub 6} have been synthesized by (1) soft-chemistry procedures and (2) high-pressure methods. The sample prepared by a soft-chemistry technique presents 75% of Fe/Re cationic order whereas the one prepared by the application of high external pressure generates a complete Fe/Re cationic order. Both materials have been characterized by X-ray diffraction, neutron powder diffraction and magnetic measurements. The magnetic properties of both oxides have been compared, observing that the specimen prepared via soft-chemistry procedures presents an enhanced Curie temperature of 445 K, although the sample prepared under high-pressure techniques displays a superior saturation magnetization. This behavior is explained as a consequence of the presence, in the partially disordered sample, of Fe-rich islands containing strong Fe-O-Fe antiferromagnetic couplings, able to nucleate and lock the ferromagnetic interactions of the ordered regions, thus increasing the global Curie temperature of the partially disordered material.

36 MATERIALS SCIENCE↗

Morphological and molecular characterization of a Sarcocystis bovifelis-like sarcocyst in American beef

Abstract Background Parasites in the apicomplexan genusSarcocystisinfect cattle worldwide. Assessing the economic importance of each such parasite species requires proper diagnosis.Sarcocystiscruzi,a thin-walled species, infects virtually all cattle. The prevalence of the other thin-walled parasite,Sarcocystisheydorni, remains less well established. The remaining six species all have thick (> 3 µm) cyst walls (Sarcocystishirsuta,S.hominis,S.bovifelis,S.bovini,S.sigmoideus, andS.rommeli). Thick-walled sarcocysts often induce inflammation in striated muscles (causing bovine eosinophilic myositis), leading to condemnation of carcasses at slaughter. One of these,S.hirsuta, can be seen macroscopically and lead to condemnation of beef. TwoSarcocystisspecies,S.hominisandS.heydorni, are zoonotic. AlthoughS.hominishas been reported as prevalent in Europe, the occurrence of thick-walled species in the US remains poorly known. Here, for the first time to our knowldge, we characterize a thick-walledSarcocystisspecies from a sample of beef from a local grocery store in Maryland. By morphological and genetic criteria, it closely, but not perfectly, resembles parasites previously ascribed toS.bovifelis. Methods Beef samples were examined forSarcocystisinfection, using acid-pepsin digestion to search for bradyzoites, microscopically by compression between a glass slide and coverslip, by histology of paraffin embedded sections stained with hematoxylin and eosin, and by transmission electron microscopy (TEM). Molecular characterization was attempted employing genetic markers:18SrRNA,28SrRNA,cox1,ITS1,gapdh1,ron3, andrpoB. Results Molecular evaluation revealed 100% identity withS.bovifelis-like sarcocysts from naturally infected cattle from Germany and Argentina; although the condition of the frozen material precludes complete characterization by TEM, we noted morphological features which differed from theS.bovifelisoriginally described from experimentally infected cattle from Germany. Conclusions A novelSarcocystisspecies is described from beef from the USA but not named until further evaluation. Graphical Abstract

Parasitology↗

Microsampling techniques for infrared spectroscopic analysis of lunar and terrestrial minerals

Microsampling techniques have been developed for infrared analysis of single mineral grains from lunar rocks and dusts, allowing a detailed molecular structure characterization of these complex fine-grained samples. The methods include special devices for isolating single grains, preparing micropellets from the grains, and obtaining in situ microspecular reflectance spectra from grains in polished rock samples. Although specifically developed for the work on lunar samples, the special techniques for single grain infrared analysis were found to be equally useful in studies of complex terrestrial mineral samples. For example, infrared microanalysis has contributed substantially in solving problems concerned with our natural resources, such as the structural characterization of minerals from commercial iron ores, marine deposits, coal, and fly ash derived from coal.

Estep, P. A.↗

Toddler home math environment: Triangulating multi-method assessments in a U.S. Sample

Introduction Current research has documented the home math environment (HME) of preschoolers and kindergarteners. Very few studies, however, have explored the number and spatial activities in which parents engage with children during their toddler years. Methods This study examined the HME of 157 toddlers using several methodologies, including surveys, time diaries, and observations of math talk. Further, it examined correlations within and across data sources to identify areas of convergence and triangulation, and correlated HME measures with measures of toddlers’ number and spatial skills. Results Findings showed that, in general, uses of different types of math activities, including both number and spatial, were intercorrelated within method. Across methods, there was high intercorrelation between the frequency of math activities reported on parent surveys and the diversity of types of math activities endorsed in time diary interviews. Parent math talk gleaned from semi-structured interviews functioned as a separate aspect of the HME; different types of math talk shared few intercorrelations with engagement in math activities as reported in either surveys or time diaries. Finally, several HME measures positively correlated with toddlers’ math skills. Discussion Given extant research demonstrating that both math activities and math talk predict children’s math skills, our results stress the need for multimethod studies that differentiate among these HME opportunities.

Miller, Portia↗

Crystallization of ApoA1 and ApoE4 Nanolipoprotein Particles and Initial XFEL-Based Structural Studies

Nanolipoprotein particles (NLPs), also called “nanodiscs”, are discoidal particles with a patch of lipid bilayer corralled by apolipoproteins. NLPs have long been of interest due to both their utility as membrane-model systems into which membrane proteins can be inserted and solubilized and their physiological role in lipid and cholesterol transport via high-density lipoprotein (HDL) and low-density lipoprotein (LDL) maturation, which are important for human health. Serial femtosecond crystallography (SFX) at X-ray free electron lasers (XFELs) is a powerful approach for structural biology of membrane proteins, which are traditionally difficult to crystallize as large single crystals capable of producing high-quality diffraction suitable for structure determination. To facilitate understanding of the specific role of two apolipoprotein/lipid complexes, ApoA1 and ApoE4, in lipid binding and HDL/LDL particle maturation dynamics, and to develop new SFX methods involving NLP membrane protein encapsulation, we have prepared and crystallized homogeneous populations of ApoA1 and ApoE4 NLPs. Crystallization of empty NLPs yields semi-ordered objects that appear crystalline and give highly anisotropic and diffuse X-ray diffraction, similar to fiber diffraction. Several unit cell parameters were approximately determined for both NLPs from these measurements. Thus, low-background, sample conservative methods of delivery are critical. Here we implemented a fixed target sample delivery scheme utilizing the Roadrunner fast-scanning system and ultra-thin polymer/graphene support films, providing a low-volume, low-background approach to membrane protein SFX. This study represents initial steps in obtaining structural information for ApoA1 and ApoE4 NLPs and developing this system as a supporting scaffold for future structural studies of membrane proteins crystalized in a native lipid environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WAXS fat subtraction model to estimate differential linear scattering coefficients of fatless breast tissue: Phantom materials evaluation

Purpose: Develop a method to subtract fat tissue contributions to wide-angle x-ray scatter (WAXS) signals of breast biopsies in order to estimate the differential linear scattering coefficients μ{sub s} of fatless tissue. Cancerous and fibroglandular tissue can then be compared independent of fat content. In this work phantom materials with known compositions were used to test the efficacy of the WAXS subtraction model. Methods: Each sample 5 mm in diameter and 5 mm thick was interrogated by a 50 kV 2.7 mm diameter beam for 3 min. A 25 mm{sup 2} by 1 mm thick CdTe detector allowed measurements of a portion of the θ = 6° scattered field. A scatter technique provided means to estimate the incident spectrum N{sub 0}(E) needed in the calculations of μ{sub s}[x(E, θ)] where x is the momentum transfer argument. Values of μ{sup ¯}{sub s} for composite phantoms consisting of three plastic layers were estimated and compared to the values obtained via the sum μ{sup ¯}{sub s}{sup ∑}(x)=ν{sub 1}μ{sub s1}(x)+ν{sub 2}μ{sub s2}(x)+ν{sub 3}μ{sub s3}(x), where ν{sub i} is the fractional volume of the ith plastic component. Water, polystyrene, and a volume mixture of 0.6 water + 0.4 polystyrene labelled as fibphan were chosen to mimic cancer, fat, and fibroglandular tissue, respectively. A WAXS subtraction model was used to remove the polystyrene signal from tissue composite phantoms so that the μ{sub s} of water and fibphan could be estimated. Although the composite samples were layered, simulations were performed to test the models under nonlayered conditions. Results: The well known μ{sub s} signal of water was reproduced effectively between 0.5 < x < 1.6 nm{sup −1}. The μ{sup ¯}{sub s} obtained for the heterogeneous samples agreed with μ{sup ¯}{sub s}{sup ∑}. Polystyrene signals were subtracted successfully from composite phantoms. The simulations validated the usefulness of the WAXS models for nonlayered biopsies. Conclusions: The methodology to measure μ{sub s} of homogeneous samples was quantitatively accurate. Simple WAXS models predicted the probabilities for specific x-ray scattering to occur from heterogeneous biopsies. The fat subtraction model can allow μ{sub s} signals of breast cancer and fibroglandular tissue to be compared without the effects of fat provided there is an independent measurement of the fat volume fraction ν{sub f}. Future work will consist of devising a quantitative x-ray digital imaging method to estimate ν{sub f} in ex vivo breast samples.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data Report: Pore Water Geochemistry at Green Canyon 955, deepwater Gulf of Mexico

Two holes were drilled in Green Canyon Block 955 (GC 955) in the deepwater Gulf of Mexico: Hole GC 955 H002 (H002) and Hole GC 955 H005 (H005). Here we present the solute concentrations and oxygen and hydrogen isotope ratios of pore water extracted from sediment whole-round samples collected from these holes. The analytical methods, degree of sample contamination, and the method for contamination correction are discussed as are the general trends in the geochemical data.

03 NATURAL GAS↗

Wind Turbine Rotor Design Optimization Using Importance Sampling: Preprint

Probabilistic methods are commonly adopted to estimate both ultimate and fatigue loads in wind turbines, and multiple papers have presented a variety of approaches. In contrast, system-level, integrated design optimization methods for wind turbines have so far relied on deterministic methods to estimate loads and deflections. This work aims at addressing this gap by adopting importance sampling to estimate ultimate blade deflection for use within a rotor design optimization. A comparison between the results of this approach against traditional approaches using deterministic load evaluations show that the probabilistic approach is more conservative and that the solutions found with deterministic approaches violate the probabilistic constraint on tip deflection between 13% and 17%. This highlights the importance of accurate load and deflection estimates and demonstrates that probabilistic approaches can be successfully integrated within a wind turbine design process despite the higher computational costs.

17 WIND ENERGY↗

Determination of Parachute Joint Factors using Seam and Joint Testing

This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

Mollmann, Catherine↗

CRYSTALLIZATION EXPERIMENTS ON AMORPHOUS MAGNESIUM SILICATE. I. ESTIMATION OF THE ACTIVATION ENERGY OF ENSTATITE CRYSTALLIZATION

In order to clarify the crystallization process of silicates in circumstellar environments around young and evolved stars, we performed a laboratory simulation of the crystallization of silicate materials by use of synthetic samples in the MgO-SiO{sub 2} system with an Mg/Si ratio of 1.07. The starting amorphous material was synthesized by a sol-gel method. The samples were heated at 1023-1073 K in an electric furnace in the atmosphere. The crystallization process of enstatite (MgSiO{sub 3}) shows nucleation delay in the early stage of the infrared spectral evolution. We quantitatively evaluated the time constant of the enstatite crystallization, and determined the activation energy to be 1.12 x 10{sup 5} K. The activation energy is much affected by the temperature dependence of nucleation. This large value indicates the kinetic inhibition of crystallization in cold circumstellar regions.

79 ASTRONOMY AND ASTROPHYSICS↗

THE DEEP LOOK AT THE HARD X-RAY SKY: THE SWIFT-INTEGRAL X-RAY (SIX) SURVEY

The supermassive black holes at the center of active galactic nuclei (AGNs) are surrounded by obscuring matter that can block nuclear radiation. Depending on the amount of blocked radiation, the flux from the AGN can be too faint to be detected by currently flying hard X-ray (above 15 keV) missions. At these energies only {approx}1% of the intensity of the cosmic X-ray background (CXB) can be resolved into point-like sources that are AGNs. In this work, we address the question of undetected sources contributing to the CXB with a very sensitive and new hard X-ray survey: the Swift-INTEGRAL X-ray survey, which is obtained with the new approach of combining the Swift/BAT and INTEGRAL/IBIS X-ray observations. We merge the observations of both missions, which enhances the exposure time and reduces systematic uncertainties. As a result, we obtain a new survey over a wide sky area of 6200 deg{sup 2} that is more sensitive than the surveys of Swift/BAT or INTEGRAL/IBIS alone. Our sample comprises 113 sources: 86 AGNs (Seyfert-like and blazars), 5 galaxies, 2 clusters of galaxies, 3 Galactic sources, 3 previously detected unidentified X-ray sources, and 14 unidentified sources. The scientific outcome from the study of the sample has been properly addressed to study the evolution of AGNs at redshift below 0.4. We do not find any evolution using the 1/V{sub max} method. Our sample of faint sources is a suitable target for the new generation hard X-ray telescopes with focusing techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of Distribution of Elastic Constants of SiC/SiC Braided Tubes

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiCf/SiCm) composite tubes due to their superior mechanical properties. There are many parameters in the manufacturing of SiCf/SiCm composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. A sensitivity analysis will be carried out to determine the dominant parameters among the abovementioned ones. We intend to determine the variability in elastic constants of SiCf/SiCm composite tubes considering the variability in dominant parameters. A chosen number of combinations of dominant variables will be sampled through Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in circumferential and longitudinal direction, Poisson's ratio and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used a surrogate to FE analysis. once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The variability can be calculated based on MCS-generated data which will be presented at the conference.

42 ENGINEERING↗

X-ray Emission Spectroscopy as an in Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free-Electron Laser

Serial femtosecond crystallography (SFX) using the ultrashort X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse, and therefore, monitoring and controlling the data quality by using in situ diagnostic tools is critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2at the Mn4CaO5active site. We used the first moments of the Mn Kβ1,3emission spectra, which are sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates and offers a metric for determining the diffraction images that are used for the final data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated thermal extraction-desorption gas chromatography mass spectrometry: A multifunctional tool for comprehensive characterization of polymers and their degradation products

The TED-GC–MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC–MS). This method is ideally suited for the analysis of polymers and their degradation processes. A new entirely automated system is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. The fractionated collection together with low temperatures reduces the risk of contamination, improves instrumental stability and minimizes maintenance efforts. Through variation of the two main parameters (purge gas flow and heating rate) it is shown how the extraction process can be optimized. By measuring the decomposition products of polyethylene it is demonstrated that compounds with masses of up to 434 Da can be detected. This is achieved despite the low temperature (˜40 °C) of the solid-phase adsorber and the low thermal desorption temperature of 200 °C in the TDU unit. It is now shown that automated TED-GC–MS represents a new flexible multi-functional method for comprehensive polymer analyses. Comparable polymer characterization was previously only achievable through a combination of multiple independent analytical methods. This is demonstrated by three examples focused on practical challenges in materials analysis and identification: The first one is the analysis of wood plastic composites for which the decomposition processes of the polymer and the bio polymer (wood) could be clearly distinguished by fractionated collection using sequential adsorbers. Secondly, a fast quantitative application is shown by determining the weight concentrations of an unknown polyolefin blend through comparison with a reference material. Additionally, the determination of microplastic concentrations in environmental samples is becoming an increasingly important analytical necessity. It is demonstrated that with TED-GC–MS calibration curves showing good linearity for the most important precursors for microplastic, even complex matrix materials (suspended particulate matter) can be successfully analyzed.

36 MATERIALS SCIENCE↗