Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Correlation between surface phonon mode and luminescence in nanocrystalline CdS thin films: An effect of ion beam irradiation

The influence of swift heavy ion irradiation (SHII) on surface phonon mode (SPM) and green emission in nanocrystalline CdS thin films grown by chemical bath deposition is studied. The SHII of nanocrystalline CdS thin films is carried out using 70 MeV Ni ions. The micro Raman analysis shows that asymmetry and broadening in fundamental longitudinal optical (LO) phonon mode increases systematically with increasing ion fluence. To analyze the role of phonon confinement, spatial correlation model (SCM) is fitted to the experimental data. The observed deviation of SCM to the experimental data is further investigated by fitting the micro Raman spectra using two Lorentzian line shapes. It is found that two Lorentzian functions (LFs) provide better fitting than SCM fitting and facilitate to identify the contribution of SPM in the observed distortion of LO mode. The behavior of SPM as a function of ion fluence is studied to correlate the observed asymmetry (Γ{sub a}/Γ{sub b}) and full width at half maximum of LO phonon mode and to understand the SHII induced enhancement of SPM. The ion beam induced interstitial and surface state defects in thin films, as observed by photoluminescence (PL) spectroscopy studies, may be the underlying reason for enhancement in SPM. PL studies also show enhancement in green luminescence with increase in ion fluence. PL analysis reveals that the variation in population density of surface state defects after SHII is similar to that of SPM. The correlation between SPM and luminescence and their dependence on ion irradiation fluence is explained with the help of thermal spike model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

OBSERVATION OF THE TeV GAMMA-RAY SOURCE MGRO J1908+06 WITH ARGO-YBJ

The extended gamma-ray source MGRO J1908+06, discovered by the Milagro air shower detector in 2007, has been observed for {approx}4 years by the ARGO-YBJ experiment at TeV energies, with a statistical significance of 6.2 standard deviations. The peak of the signal is found at a position consistent with the pulsar PSR J1907+0602. Parameterizing the source shape with a two-dimensional Gauss function, we estimate an extension of {sigma}{sub ext} = 0.{sup 0}49 {+-} 0.{sup 0}22, which is consistent with a previous measurement by the Cherenkov Array H.E.S.S. The observed energy spectrum is dN/dE = 6.1 {+-} 1.4 Multiplication-Sign 10{sup -13} (E/4 TeV){sup -2.54{+-}0.36} photons cm{sup -2} s{sup -1} TeV{sup -1}, in the energy range of {approx}1-20 TeV. The measured gamma-ray flux is consistent with the results of the Milagro detector, but is {approx}2-3 times larger than the flux previously derived by H.E.S.S. at energies of a few TeV. The continuity of the Milagro and ARGO-YBJ observations and the stable excess rate observed by ARGO-YBJ and recorded in four years of data support the identification of MGRO J1908+06 as the steady powerful TeV pulsar wind nebula of PSR J1907+0602, with an integrated luminosity over 1 TeV {approx} 1.8 times the luminosity of the Crab Nebula.

79 ASTRONOMY AND ASTROPHYSICS↗

OBSERVATION OF TeV GAMMA RAYS FROM THE UNIDENTIFIED SOURCE HESS J1841-055 WITH THE ARGO-YBJ EXPERIMENT

We report the observation of a very high energy {gamma}-ray source whose position is coincident with HESS J1841-055. This source has been observed for 4.5 years by the ARGO-YBJ experiment from 2007 November to 2012 July. Its emission is detected with a statistical significance of 5.3 standard deviations. Parameterizing the source shape with a two-dimensional Gaussian function, we estimate an extension {sigma}=(0.40{sup +0.32}{sub -0.22}){sup o}, which is consistent with the HESS measurement. The observed energy spectrum is dN/dE = (9.0 {+-} 1.6) Multiplication-Sign 10{sup -13}(E/5 TeV){sup -2.32{+-}0.23} photons cm{sup -2} s{sup -1} TeV{sup -1}, in the energy range 0.9-50 TeV. The integral {gamma}-ray flux above 1 TeV is 1.3 {+-} 0.4 Crab, which is 3.2 {+-} 1.0 times the flux derived by HESS. The differences in the flux determination between HESS and ARGO-YBJ and possible counterparts at other wavelengths are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

LARGE-SCALE STRUCTURE OF THE UNIVERSE AS A COSMIC STANDARD RULER

We propose to use the large-scale structure (LSS) of the universe as a cosmic standard ruler. This is possible because the pattern of large-scale distribution of matter is scale-dependent and does not change in comoving space during the linear-regime evolution of structure. By examining the pattern of LSS in several redshift intervals it is possible to reconstruct the expansion history of the universe, and thus to measure the cosmological parameters governing the expansion of the universe. The features of the large-scale matter distribution that can be used as standard rulers include the topology of LSS and the overall shapes of the power spectrum and correlation function. The genus, being an intrinsic topology measure, is insensitive to systematic effects such as the nonlinear gravitational evolution, galaxy biasing, and redshift-space distortion, and thus is an ideal cosmic ruler when galaxies in redshift space are used to trace the initial matter distribution. The genus remains unchanged as far as the rank order of density is conserved, which is true for linear and weakly nonlinear gravitational evolution, monotonic galaxy biasing, and mild redshift-space distortions. The expansion history of the universe can be constrained by comparing the theoretically predicted genus corresponding to an adopted set of cosmological parameters with the observed genus measured by using the redshift-comoving distance relation of the same cosmological model.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MASS-INDEPENDENCE OF SPECIFIC STAR FORMATION RATES IN GALACTIC DISKS

The slope of the star formation rate/stellar mass relation (the SFR {sup M}ain Sequence{sup ;} SFR-M {sub *}) is not quite unity: specific star formation rates (SFR/M {sub *}) are weakly but significantly anti-correlated with M {sub *}. Here we demonstrate that this trend may simply reflect the well-known increase in bulge mass-fractions—portions of a galaxy not forming stars—with M {sub *}. Using a large set of bulge/disk decompositions and SFR estimates derived from the Sloan Digital Sky Survey, we show that re-normalizing SFR by disk stellar mass (sSFR{sub disk} ≡ SFR/M {sub *,} {sub disk}) reduces the M {sub *} dependence of SF efficiency by ∼0.25 dex per dex, erasing it entirely in some subsamples. Quantitatively, we find log sSFR{sub disk}-log M {sub *} to have a slope β{sub disk} in [ – 0.20, 0.00] ± 0.02 (depending on the SFR estimator and Main Sequence definition) for star-forming galaxies with M {sub *} ≥ 10{sup 10} M {sub ☉} and bulge mass-fractions B/T ≲ 0.6, generally consistent with a pure-disk control sample (β{sub control} = –0.05 ± 0.04). That (SFR/M {sub *,} {sub disk}) is (largely) independent of host mass for star-forming disks has strong implications for aspects of galaxy evolution inferred from any SFR-M {sub *} relation, including manifestations of ''mass quenching'' (bulge growth), factors shaping the star-forming stellar mass function (uniform dlog M {sub *}/dt for low-mass, disk-dominated galaxies), and diversity in star formation histories (dispersion in SFR(M {sub *}, t)). Our results emphasize the need to treat galaxies as composite systems—not integrated masses—in observational and theoretical work.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: Single-probe measurements from DR12 galaxy clustering – towards an accurate model

We analyze the broad-range shape of the monopole and quadrupole correlation functions of the BOSS Data Release 12 (DR12) CMASS and LOWZ galaxy sample to obtain constraints on the Hubble expansion rate H(z), the angular-diameter distance DA(z), the normalised growth rate f(z)σ 8 (z), and the physical matter density Ω m h 2 . In addition, we adopt wide and flat priors on all model parameters in order to ensure the results are those of a `single-probe' galaxy clustering analysis. We also marginalize over three nuisance terms that account for potential observational systematics affecting the measured monopole. However, such Monte Carlo Markov Chain analysis is computationally expensive for advanced theoretical models, thus we develop a new methodology to speed up our analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Revealing the pseudogap in Sr 3 (Ru 0.985 Fe 0.015 ) 2 O 7 by optical spectroscopy

We report resistivity, magnetization, and optical spectroscopy study on single-crystal sample of Sr 3 (Ru 0.985 Fe 0.015 ) 2 O 7 . An upturn is observed in resistivity at about 30 K. Below 30 K, the dip in resistivity R(ω), the suppression in scattering rate 1/τ(ω), the peaklike feature in optical conductivity σ 1 (ω), and the remainder of spectral weight all suggest the formation of a pseudogap. In addition, one phonon peak at about 600cm –1 is distinguished at all temperatures, which has asymmetric line shape. Such asymmetric line shape can be fit by a Fano function, and the resulting Fano factor 1/q 2 and linewidth γ show significant increases below 30 K, giving further evidence for the formation of a pseudogap, which might originate from the partial k-space gap opening due to density wave instability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic modeling of mass and charge distributions in the spontaneous fission of 240 Pu

We propose a methodology to calculate microscopically the mass and charge distributions of spontaneous fission yields. We combine the multidimensional minimization of collective action for fission with stochastic Langevin dynamics to track the relevant fission paths from the ground-state configuration up to scission. The nuclear potential energy and collective inertia governing the tunneling motion are obtained with nuclear density functional theory in the collective space of shape deformations and pairing. As a result, we obtain a quantitative agreement with experimental data and find that both the charge and mass distributions in the spontaneous fission of 240 Pu are sensitive both to the dissipation in collective motion and to adiabatic fission characteristics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large deviations in the presence of cooperativity and slow dynamics

We study simple models of intermittency, involving switching between two states, within the dynamical large-deviation formalism. Singularities appear in the formalism when switching is cooperative or when its basic time scale diverges. In the first case the unbiased trajectory distribution undergoes a symmetry breaking, leading to a change in shape of the large-deviation rate function for a particular dynamical observable. In the second case the symmetry of the unbiased trajectory distribution remains unbroken. Comparison of these models suggests that singularities of the dynamical large-deviation formalism can signal the dynamical equivalent of an equilibrium phase transition but do not necessarily do so.

97 MATHEMATICS AND COMPUTING↗

Attributes of Bi-Directional Turbomachinery for Pumped Thermal Energy Storage

Abstract In this paper, we (i) present a methodology for determining the aerodynamic performance of bi-directional turbomachines for pumped thermal energy storage, i.e., turbomachines designed to operate as a compressor in one direction, and then as a turbine in the opposite direction, (ii) carry out performance computations for such turbomachines, and (iii) propose principles for conceptual design of these devices. Focus is placed on using the energy storage cycle not only to identify the novel requirements placed on bi-directional turbomachines but also to estimate the effect of these requirements on the efficiency of the energy storage process. In particular, the difference between aerodynamic loading in forward and in backward operation causes the blading to work at incidences leading to the performance below maximum efficiency, resulting in a lower round-trip efficiency. The description of the design principles includes determination of the number of stages, definition of nondimensional parameters for blading selection, and optimization of two-dimensional blading for bi-directional operation. The assessment of stage count shows the relationship between relative Mach number, pressure ratio, and round-trip efficiency. The nondimensional parameters are assessed through a bi-directional analogue to existing “Smith charts,” for the efficiency of single-direction turbomachines, as a function of camber and stagger. The blade shape evaluation and optimization show how the blade profile can be modified to address the requirements of a bi-directional turbomachine, enabling an increase in round-trip efficiency of two percentage points compared to a baseline double circular arc configuration.

Engineering↗

Analytical expressions of the surface shape of ‘diaboloid’ mirrors

Modern deterministic polishing processes allow fabrication of x-ray optics with almost any arbitrary aspherical surface shape. Among these optics, the so called "diaboloid"mirror is of special interest. The diaboloid mirror that converts a cylindrical wave to a spherical wave would improve focusing in x-ray beamlines implementing a diffraction element between a parabolic cylinder and a toroidal mirror. The replacement of the toroidal mirror in existing beamlines by the diaboloid mirror would mitigate aberrations. The shape of the diaboloid mirror is usually calculated numerically based on a truncated polynomial solution of the optical path problem. Here, we present an exact analytical solution for the shape of a diaboloid mirror as a function of the conjugate parameters of the mirror placed in a beamline. The derived analytical expressions for the diaboloid mirror in both the canonical and mirror-based coordinate systems are implemented in ray-tracing simulations to verify the beamline performances.

Yashchuk, Valeriy V.↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comprehensive formulation for volumetric modulated arc therapy planning

Purpose: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations. Methods: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropic total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases—one with three PTVs (H&N{sub 3PTV}) and one with foue PTVs (H&N{sub 4PTV})—to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment. Results: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N{sub 3PTV} case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac’s capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-01: A Global Level Set Based Formulation for Volumetric Modulated Arc Therapy

Purpose: The current clinical Volumetric Modulated Arc Therapy (VMAT) optimization is formulated as a non-convex problem and various greedy heuristics have been employed for an empirical solution, jeopardizing plan consistency and quality. We introduce a novel global direct aperture optimization method for VMAT to overcome these limitations. Methods: The global VMAT (gVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term and an anisotropic total variation term. A level set function was used to describe the aperture shapes and adjacent aperture shapes were penalized to control MLC motion range. An alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc gVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme (GBM), lung (LNG), and 2 head and neck cases—one with 3 PTVs (H&N3PTV) and one with 4 PTVs (H&N4PTV). The plans were compared against the clinical VMAT (cVMAT) plans utilizing two overlapping coplanar arcs. Results: The optimization of the gVMAT plans had converged within 600 iterations. gVMAT reduced the average max and mean OAR dose by 6.59% and 7.45% of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N3PTV case. PTV coverages (D95, D98, D99) were within 0.25% of the prescription dose. By globally considering all beams, the gVMAT optimizer allowed some beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel VMAT approach allows for the search of an optimal plan in the global solution space and generates deliverable apertures directly. The single arc VMAT approach fully utilizes the digital linacs’ capability in dose rate and gantry rotation speed modulation. Varian Medical Systems, NIH grant R01CA188300, NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Thermomechanics of Deformations in an Anharmonic Solid Body

The macroscopic laws determining the temperature and deformations of an anharmonic solid body in a given external temperature force field have been stated in the form of the first thermodynamics law supplemented by equations of state of the body. The internal and free energies necessary for it are found from the statistical sum in which some of degrees of freedom determining the body shape are discharged from statistical averaging. These functions of state have been calculated up to the first order of the perturbation theory in the anharmonicity for the microscopic dynamic model of the body with the interatomic interaction potential energy given as a series in powers of atom coordinates. The classical region of high temperatures is considered.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Final Report of the Project "From the finite element method to the virtual element method"

The Finite Element Method (FEM) is a powerful numerical tool that is being used in a large number of engineering applications. The FEM is constructed on triangular/tetrahedral and quadrilateral/hexahedral meshes. Extending the FEM to general polygonal/polyhedral meshes in straightforward way turns out to be extremely difficult and leads to very complex and computationally expensive schemes. The reason for this failure is that the construction of the basis functions on elements with a very general shape is a non-trivial and complex task. In this project we developed a new family of numerical methods, dubbed the Virtual Element Method (VEM) for the numerical approximation of partial differential equations (PDE) of elliptic type suitable to polygonal and polyhedral unstructured meshes. We successfully formulated, implemented and tested these methods and studied both theoretically and numerically their stability, robustness and accuracy for diffusion problems, convection-reaction-diffusion problems, the Stokes equations and the biharmonic equations.

97 MATHEMATICS AND COMPUTING↗

Experimentally Determined Anisotropic Yield Surfaces for Al 7079

Isotropic von Mises and anisotropic Hill yield surfaces for Al 7079 were fit using experimental data gathered from 12 dog-bone specimens that captured the highly variable microstructural texture of the aluminum alloy. Strain gauges or the digital image correlation technique were utilized to determine the strain histories in the specimen as they were subjected to uniaxial tension. The final yield surface fits displayed a high degree of variability that was dependent upon how the yield functions were calculated, i.e. which size and shape information was used. The findings display that a model with a higher number of anisotropic parameters is needed to better and more consistently capture the anisotropic properties of Al 7079, such as the Barlat, Yld2004-18, model that has 20 parameters.

36 MATERIALS SCIENCE↗

Three-Flavor Neutrino Oscillations with MINOS+

This dissertation presents the analysis of the last two years of data from the MINOS+ long-baseline neutrino oscillation experiment. The analysis explores the data above the first oscillation maximum for neutrinos in the standard three-flavor neutrino oscillation model, adding significantly more neutrino events and constraining the model with increased precision. The analysis of the high-energy region of the MINOS+ data set, where previously there has been limited study, can help constrain alternative models or possibly show evidence of new phenomena. The predecessor to MINOS+, the MINOS experiment, measured $\nu_\mu$ disappearance and $\nu_{e}$ appearance using Fermilab's NuMI $\nu_\mu$ beam from 2005 to 2012. During this period the neutrino beam's energy spectrum was focused to peak near the first oscillation maximum. In addition to measuring accelerator beam neutrinos, the MINOS Far Detector collected a sample of atmospheric neutrinos from 2003 to 2011. With the se two samples, MINOS measured the atmospheric mass splitting, $\Delta{m}^2_{32}$, at the 5\% level and the value of $\sin^2\theta_{23}$ at the 15\% level. The data also constrained the CP violating parameter $\delta_{\rm CP}$. The MINOS+ experiment exposed the MINOS detectors to a neutrino beam peaked at energies above the oscillation maximum from 2013 to 2016. With this higher energy neutrino beam, MINOS+ measures the shape of the $\nu_\mu$ survival probability away from the oscillation maximum with unprecedented precision. Measuring the shape of the oscillation probability as a function of neutrino energy is an essential test of the three-flavor oscillation model. At these higher energies where the standard oscillation probability decreases, the neutrino energy spectrum is sensitive to potential perturbations from mixing with additional sterile neutrinos or non-standard neutrino interactions. This analysis of the complete data set from MINOS+ finds no significant deviatio ns from the three-flavor oscillation probability in the ener! gy region of 4 to 10\,GeV covered by the neutrino beam. This provides increased confidence in the three-flavor model in this region and provides new constraints of the atmospheric oscillation parameters, $\Delta{m}^2_{32}$ and $\sin^2\theta_{23}$, by combining the MINOS and MINOS+ data sets. The hierarchy of the neutrino masses is related to the sign of $\Delta{m}^2_{32}$. When $\Delta{m}^2_{32} > 0$, the mass hierarchy is classified as normal. When $\Delta{m}^2_{32} < 0$, the mass hierarchy is classified as inverted. This analysis cannot rule out either of the mass hierarchies. For the normal mass hierarchy, the combined analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.41\pm 0.09 \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{-0.06}^{+0.23}$ at 90\% C.L. For the inverted mass hierarchy, this analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.47_{-0.10}^{+0.08} \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{ -0.06}^{+0.23}$ at 90\% C.L. In addition to the analysis and measurement of the atmospheric oscillation parameters using MINOS+, this work updates the constraint on $\delta_{\rm CP}$ from MINOS and performs an exploratory combination using $\nu_\mu$ disappearance data from the NOvA experiment. The NOvA experiment uses the NuMI beam in an off-axis strategy that results in a narrow flux of muon neutrinos at the first oscillation maximum and allows precision measurements of the three-flavor parameters. Since NOvA and MINOS+ shared the same neutrino beam, their data can be combined taking advantage of common beam related uncertainties. Combined, the data from the MINOS, MINOS+, and NOvA experiments precisely map $\nu_\mu$ oscillation probabilities using the same neutrino beam in a way that could not be attempted before.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗