Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Families of Graph Algorithms: SSSP Case Study

Single-Source Shortest Paths (SSSP) is a well-studied graph problem. Examples of SSSP algorithms include the original Dijkstra’s algorithm and the parallel Δ-stepping and KLA-SSSP algorithms. In this paper, we use a novel Abstract Graph Machine (AGM) model to show that all these algorithms share a common logic and differ from one another by the order in which they perform work. We use the AGM model to thoroughly analyze the family of algorithms that arises from the common logic. We start with the basic algorithm without any ordering (Chaotic), and then we derive the existing and new algorithms by methodically exploring semantic and spatial ordering of work. Our experimental results show that new derived algorithms show better performance than the existing distributed memory parallel algorithms, especially at higher scales.

distributed-memory graph algorithms↗

Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise

A frequency-dependent x-ray Swank factor based on the ''x-ray interaction'' modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI{sub 2}) for incident photon energies between 10 and 150 keV and various converter thicknesses. When scaled by the quantum efficiency, the x-ray Swank factor describes the best possible detective quantum efficiency (DQE) a detector can have. As such, this x-ray interaction DQE provides a target performance benchmark. It is expressed as a function of (Fourier-based) spatial frequency and takes into consideration signal and noise correlations introduced by reabsorption of Compton scatter and photoelectric characteristic emissions. It is shown that the x-ray Swank factor is largely insensitive to converter thickness for quantum efficiency values greater than 0.5. Thus, while most of the tabulated values correspond to thick converters with a quantum efficiency of 0.99, they are appropriate to use for many detectors in current use. A simple expression for the x-ray interaction DQE of digital detectors (including noise aliasing) is derived in terms of the quantum efficiency, x-ray Swank factor, detector element size, and fill factor. Good agreement is shown with DQE curves published by other investigators for each converter material, and the conditions required to achieve this ideal performance are discussed. For high-resolution imaging applications, the x-ray Swank factor indicates: (i) a-Si should only be used at low-energy (e.g., mammography); (ii) a-Se has the most promise for any application below 100 keV; and (iii) while quantum efficiency may be increased at energies just above the K edge in CsI and PbI{sub 2}, this benefit is offset by a substantial drop in the x-ray Swank factor, particularly at high spatial frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping

Purpose: This article presents a general procedural framework to assess the point-by-point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient. Methods: Dose uncertainty is obtained via a three-step process. In the first step, for each voxel in an imaging pair, a cluster of points is obtained by an iterative DIR procedure. In the second step, the dispersion of the points due to the imprecision of the DIR method is used to compute the spatial uncertainty. Two different ways to quantify the spatial uncertainty are presented in this work. Method A consists of a one-dimensional analysis of the modules of the position vectors, whereas method B performs a more detailed 3D analysis of the coordinates of the points. In the third step, the resulting spatial uncertainty estimates are used in combination with the mapped dose distribution to compute the point-by-point dose standard deviation. The process is demonstrated to estimate the dose uncertainty induced by mapping a 62.6 Gy dose delivered on maximum exhale to maximum inhale of a ten-phase four-dimensional lung CT. Results: For the demonstration lung image pair, the standard deviation of inconsistency vectors is found to be up to 9.2 mm with a mean {sigma} of 1.3 mm. This uncertainty results in a maximum estimated dose uncertainty of 29.65 Gy if method A is used and 21.81 Gy for method B. The calculated volume with dose uncertainty above 10.00 Gy is 602 cm{sup 3} for method A and 1422 cm{sup 3} for method B. Conclusions: This procedure represents a useful tool to evaluate the precision of a mapped dose distribution due to the intrinsic DIR uncertainty in a patient. The procedure is flexible, allowing incorporation of alternative intrinsic error models.

60 APPLIED LIFE SCIENCES↗

Predicting Storm Outages Through New Representations of Weather and Vegetation

This paper presents new developments in an outage prediction model (OPM) for an electric distribution network in the Northeastern United States and assesses their significance to the OPM performance. The OPM uses regression tree models fed by numerical weather prediction outputs, spatially distributed information on soil, vegetation, electric utility assets, and historical power outage data to forecast the number and spatial distribution of outages across the power distribution grid. New modules introduced hereby consist in 1) a storm classifier based on weather variables; 2) a multimodel optimization of regression tree output; and 3) a post-processing routine for more accurately describing tree-leaf conditions. Model implementations are tested through leave-one-storm-out cross-validations performed on 120 storms of varying intensity and characteristics. The results demonstrate that the median absolute percentage error of the new OPM version decreased from 130% to 59% for outage predictions at the service territory level, and the OPM skills for operational forecasts are consistent with the skills based on historical storm analyses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging performance comparison between a LaBr{sub 3}:Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera

The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr{sub 3}:Ce scintillator continuous crystal (49x49x5 mm{sup 3}) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14x14x1 mm{sup 3}) with 256x256 square pixels and a pitch of 55 {mu}m, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 {mu}m, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE

This report summarizes the neutron imaging techniques and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. The experimental results and technique developments reported herein support the US Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in hightemperature microreactor designs is addressed by means of high-spatial-resolution neutron imaging coupled with custom-built and application-specific furnaces. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. Neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metals hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on the first two in-situ heating measurements of YH x performed over the 2020 and 2021 LANSCE operation cycles. In parallel with in-situ heating measurements, neutron computed tomography scans were performed to visualize hydrogen aggregates in post-heated YH x samples. Analysis and results from these neutron imaging measurements are given along with outlooks and plans for improving future hydrogen diffusion measurements at LANSCE.

47 OTHER INSTRUMENTATION↗

Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak

A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time streamflow forecasting: AI vs. Hydrologic insights

In this paper, we propose a set of simple benchmarks for the evaluation of data-based models for real-time streamflow forecasting, such as those developed with sophisticated Artificial Intelligence (AI) algorithms. The benchmarks are also data-based and provide context to judge incremental improvements in the performance metrics from the more complicated approaches. The benchmarks include temporal and spatial persistence, persistence corrected for baseflow and streamflow, as well as river distance weighted runoff obtained from space-time distributed rainfall. In the development of the benchmarks, we use basic hydrologic insights such as flow aggregation by the river network, scale-dependence in basin response, streamflow partitioning into quick flow and baseflow, water travel time, and rainfall averaging by the basin width function. The study uses 140 streamflow gauges in Iowa that cover a range of basin scales between 7 and 37,000 km 2 . The data cover 17 years. This work demonstrates that the proposed benchmarks can provide good performance according to several commonly used metrics. For example, streamflow forecasting at half of the test locations across years achieves a Kling-Gupta Efficiency (KGE) score of 0.6 or higher at one-day ahead lead time, and 20% of cases reach the KGE of 0.8 or higher. The proposed benchmarks are easy to implement and should prove useful for developers of data-based as well as physics-based hydrologic models and real-time data assimilation techniques.

54 ENVIRONMENTAL SCIENCES↗

Gravitational dynamics in s+1+1 dimensions II. Hamiltonian theory

We develop a Hamiltonian formalism of braneworld gravity, which singles out two preferred, mutually orthogonal directions. One is a unit twist-free field of spatial vectors with integral lines intersecting perpendicularly the brane. The other is a temporal vector field with respect to which we perform the Arnowitt-Deser-Misner decomposition of the Einstein-Hilbert Lagrangian. The gravitational variables arise from the projections of the spatial metric and their canonically conjugated momenta as tensorial, vectorial and scalar quantities defined on the family of hypersurfaces containing the brane. They represent the gravitons, a gravi-photon, and a gravi-scalar, respectively. From the action we derive the canonical evolution equations and the constraints for these gravitational degrees of freedom both on the brane and outside it. By integrating across the brane, the dynamics also generates the tensorial and scalar projection of the Lanczos equation. The vectorial projection of the Lanczos equation arises in a similar way from the diffeomorphism constraint. Both the graviton and the gravi-scalar are continuous across the brane, however the momentum of the gravi-vector has a jump, related to the energy transport (heat flow) on the brane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metrics for evaluating tropical cyclones in climate data

This manuscript describes a software suite that can be used for objective evaluation of tropical cyclones (TCs) in gridded climate data. Using cyclone trajectories derived from 6-hourly data, a comprehensive set of metrics is defined to systematically compare and contrast products to one another. In addition to annual TC climatologies, attention is paid to spatial and temporal patterns of storm occurrence and intensity. Assessment can be performed either on the global scale or regional domains. Simple to visualize ‘scorecards’ allow for rapid credibility assessment. We showcase three key findings enabled by this suite. First, we compare the representation of TCs in seven current-generation global reanalyses and conclude that higher resolution models and those with TC-specific assimilation contain more accurate storm climatologies. Second, using a free-running Earth system model (ESM) we find that full basin refinement is required in variable-resolution configurations to adequately simulate North Atlantic TC frequency. Furthermore, upstream refinement over northern Africa offers little benefit in simulating storm occurrence but spatial genesis patterns are improved. Finally, we show that TCs simulated by ESMs can be highly sensitive to individual parameterizations in climate models, with North Atlantic TC metrics varying greatly depending on version of the Morrison-Gettelman microphysics package.

54 ENVIRONMENTAL SCIENCES↗

MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging

Introduction We describe a compact, portable dual-gamma camera system (named "MONICA" for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed ?looking up? through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results Tc-99m performance measurements, using a photopeak energy window of 140 keV?10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/μCi); energy resolution (FWHM, full width at half maximum), 10.8%; count rate linearity (count rate vs. activity), r2=0.99 for 0?185 MBq (0?5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period. Conclusion Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization study for the experimental configuration of CMB-S4

The CMB Stage 4 (CMB-S4) experiment is a next-generation, ground-based experiment that will measure the cosmic microwave background (CMB) polarization to unprecedented accuracy, probing the signature of inflation, the nature of cosmic neutrinos, relativistic thermal relics in the early universe, and the evolution of the universe. CMB-S4 will consist of O (500,000) photon-noise-limited detectors that cover a wide range of angular scales in order to probe the cosmological signatures from both the early and late universe. It will measure a wide range of microwave frequencies to cleanly separate the CMB signals from galactic and extra-galactic foregrounds. To advance the progress towards designing the instrument for CMB-S4, we have established a framework to optimize the instrumental configuration to maximize its scientific output. The framework combines cost and instrumental models with a cosmology forecasting tool, and evaluates the scientific sensitivity as a function of various instrumental parameters. The cost model also allows us to perform the analysis under a fixed-cost constraint, optimizing for the scientific output of the experiment given finite resources. In this paper, we report our first results from this framework, using simplified instrumental and cost models. Here, we have primarily studied two classes of instrumental configurations: arrays of large-aperture telescopes with diameters ranging from 2–10 m, and hybrid arrays that combine small-aperture telescopes (0.5-m diameter) with large-aperture telescopes. We explore performance as a function of telescope aperture size, distribution of the detectors into different microwave frequencies, survey strategy and survey area, low-frequency noise performance, and balance between small and large aperture telescopes for hybrid configurations. Both types of configurations must cover both large (~ degree) and small (~ arcmin) angular scales, and the performance depends on assumptions for performance vs. angular scale. The configurations with large-aperture telescopes have a shallow optimum around 4–6 m in aperture diameter, assuming that large telescopes can achieve good performance for low-frequency noise. We explore some of the uncertainties of the instrumental model and cost parameters, and we find that the optimum has a weak dependence on these parameters. The hybrid configuration shows an even broader optimum, spanning a range of 4–10 m in aperture for the large telescopes. We also present two strawperson configurations as an outcome of this optimization study, and we discuss some ideas for improving our simple cost and instrumental models used here. There are several areas of this analysis that deserve further improvement. In our forecasting framework, we adopt a simple two-component foreground model with spatially varying power-law spectral indices. We estimate de-lensing performance statistically and ignore non-idealities such as anisotropic mode coverage, boundary effect, and possible foreground residual. Instrumental systematics, which is not accounted for in our analyses, may also influence the conceptual design. Further study of the instrumental and cost models will be one of the main areas of study by the entire CMB-S4 community. Finally, we hope that our framework will be useful for estimating the influence of these improvements in the future, and we will incorporate them in order to further improve the optimization.

79 ASTRONOMY AND ASTROPHYSICS↗

Delineating Facies Spatial Distribution by Integrating Ensemble Data Assimilation and Indicator Geostatistics with Level-Set Transformation

The facies-based approach has been widely adopted to delineate an aquifer into distinct geological units with unique distributions of hydraulic, physical, and/or chemical properties. The recent development in ensemble-based data assimilation methods allows both the direct and indirect data to be used to improve facies delineation. A major difficulty in those applications is to honor the spatial continuity and avoid overfitting after data assimilation. We introduce a new facies delineation framework to integrate ensemble data assimilation with traditional transition probability-based geostatistics. A level-set concept is used to parametrize discrete facies indicators and for updating facies shape. During the iterative data assimilation process, we impose spatial continuity by conditioning facies field generation on points selected adaptively based on their sensitivity to observation data. This reconditioning step is a key step to maintain spatial continuity and overcome over-fitting problems in inversion. We selected two examples to evaluate the performance of the new framework in estimating facies-based permeability field. The first example is a two-dimensional synthetic system with transient head data induced by pumping tests used for delineating two facies. The second example is a three-dimensional case with three facies, conceptualized from a field tracer experiment within the Columbia River corridor in Washington State, USA. Both examples demonstrate that the new method can adequately capture the spatial pattern of hydrofacies with reconditioning, which leads to the improved prediction of system behaviors.

Song, Xuehang↗

Search for Spatially Extended Fermi-LAT Sources Using Two Years of Data

Spatial extension is an important characteristic for correctly associating {gamma}-ray-emitting sources with their counterparts at other wavelengths and for obtaining an unbiased model of their spectra. We present a new method for quantifying the spatial extension of sources detected by the Large Area Telescope (LAT), the primary science instrument on the Fermi Gamma-ray Space Telescope (Fermi). We perform a series of Monte Carlo simulations to validate this tool and calculate the LAT threshold for detecting the spatial extension of sources. We then test all sources in the second Fermi -LAT catalog (2FGL) for extension. We report the detection of seven new spatially extended sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploring Mission Design for Imaging Spectroscopy Retrievals for Land and Aquatic Ecosystems

The retrieval algorithms used for optical remote sensing satellite data to estimate Earth's geophysical properties have specific requirements for spatial resolution, temporal revisit, spectral range and resolution, and instrument signal-to-noise ratio (SNR) performance to meet biogeoscience objectives. Studies to estimate surface properties from hyperspectral data use a range of algorithms sensitive to various sources of spectroscopic uncertainty, which are in turn influenced by mission architecture choices. Retrieval algorithms vary across scientific fields and may be more or less sensitive to mission architecture choices that affect spectral, spatial, or temporal resolutions and spectrometer SNR. We used representative remote sensing algorithms across terrestrial and aquatic study domains to inform aspects of mission design that are most important for impacting accuracy in each scientific area. We simulated the propagation of uncertainties in the retrieval process including the effects of different instrument configuration choices. We found that retrieval accuracy and information content degrade consistently at >10 nm spectral resolution, >30 m spatial resolution, and >8-day revisit. In these studies, the noise reduction associated with lower spatial resolution improved accuracy vis à vis high spatial resolution measurements. The interplay between spatial resolution, temporal revisit, and SNR can be quantitatively assessed for imaging spectroscopy missions and used to identify key components of algorithm performance and mission observing criteria.

54 ENVIRONMENTAL SCIENCES↗

Optics design for J-TEXT ECE imaging with field curvature adjustment lens

Significant progress has been made in the imaging and visualization of magnetohydrodynamic and microturbulence phenomena in magnetic fusion plasmas. Of particular importance has been microwave electron cyclotron emission imaging (ECEI) for imaging T{sub e} fluctuations. Key to the success of ECEI is a large Gaussian optics system constituting a major portion of the focusing of the microwave radiation from the plasma to the detector array. Both the spatial resolution and observation range are dependent upon the imaging optics system performance. In particular, it is critical that the field curvature on the image plane is reduced to decrease crosstalk between vertical channels. The receiver optics systems for two ECEI on the J-TEXT device have been designed to ameliorate these problems and provide good performance with additional field curvature adjustment lenses with a meniscus shape to correct the aberrations from several spherical surfaces.

43 PARTICLE ACCELERATORS↗

Time Evolution of Electric Fields in CDMS Detectors

The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3-inch diameter x 1-inch thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors, the later providing a {approx}1 V cm{sup -1} electric field in the detector bulk. Cumulative radiation exposure which creates {approx}200 x 10{sup 6} electron-hole pairs could be sufficient to produce a comparable reverse field in the detector thereby degrading the ionization channel performance, if it was not shielded by image charges on the electrodes. To study this, the existing CDMS detector Monte Carlo has been modified to allow for an event by event evolution of the bulk electric field, in three spatial dimensions. Surprisingly, this simple model is not sufficient to explain the degradation of detector performance. Our most recent results and interpretation are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗