Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Time-temperature-stress superposition of PBX 9502 compressive creep data for lifetime predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Data Repository for Power system Open models With Evolving Resources (DR POWER) (Final Scientific/Technical Report)

Pacific Northwest National Laboratory (PNNL) and the National Rural Electric Cooperative Association (NRECA) created a Data Repository for Power system Open models With Evolving Resources (DR POWER) to establish, curate, and evolve open-access power grid models and scenarios, and measurements and observations, collectively referred to as datasets. Existing open-access datasets are inadequate (too small and not representative of the complexity of the modern grid, and scattered all over the world wide web) for the investigation and benchmarking of the advanced optimization methods needed for next-generation grids. Open-access datasets are static and inadequate in other aspects: they do not provide format transformation tools; there is missing information needed for advanced applications; hard to cite; no model evolution history; difficult to update current collections; and little to no community involvement and feedback. Overall, the current landscape is hindering model evolution and benchmarking standards needed for transformational approaches to be developed, tested, and accepted by the power modeling community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-Temperature-Stress Superposition of PBX 9502 Compressive Creep Data for Lifetime Predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

A Moist Physics Parameterization Based on Deep Learning

Abstract Current moist physics parameterization schemes in general circulation models (GCMs) are the main source of biases in simulated precipitation and atmospheric circulation. Recent advances in machine learning make it possible to explore data‐driven approaches to developing parameterization for moist physics processes such as convection and clouds. This study aims to develop a new moist physics parameterization scheme based on deep learning. We use a residual convolutional neural network (ResNet) for this purpose. It is trained with 1‐year simulation from a superparameterized GCM, SPCAM. An independent year of SPCAM simulation is used for evaluation. In the design of the neural network, referred to as ResCu, the moist static energy conservation during moist processes is considered. In addition, the past history of the atmospheric states, convection, and clouds is also considered. The predicted variables from the neural network are GCM grid‐scale heating and drying rates by convection and clouds, and cloud liquid and ice water contents. Precipitation is derived from predicted moisture tendency. In the independent data test, ResCu can accurately reproduce the SPCAM simulation in both time mean and temporal variance. Comparison with other neural networks demonstrates the superior performance of ResNet architecture. ResCu is further tested in a single‐column model for both continental midlatitude warm season convection and tropical monsoonal convection. In both cases, it simulates the timing and intensity of convective events well. In the prognostic test of tropical convection case, the simulated temperature and moisture biases with ResCu are smaller than those using conventional convection and cloud parameterizations.

54 ENVIRONMENTAL SCIENCES↗

An Application for Validation of Power Distribution System Models in an ADMS Environment

An accurate model of a power distribution system is the foundation for model-based applications that ensure efficient and reliable grid operation in an advanced distribution management system (ADMS) environment. However, these models are error-prone and comprehensive model validation is challenging due to lack of standards-based systems, data originating from disparate databases and other sources, and the constantly evolving nature of modern power distribution systems. In this paper, a novel framework for comprehensive model validation is described. The proposed application, the Model Validator, ensures that a model is both consistent and feasible by validating the derivative static and operational network model. A modular architecture for the application has been implemented and integrated with an open-source standards-based platform for ADMS application development, GridAPPS-D, allowing new validation capability to be added with minimal time and effort. The Model Validator application is demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test cases over three validation scenarios.

Poudel, Shiva↗

Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy

Purpose: Hypofractionated prostate radiotherapy may benefit from both volumetric modulated arc therapy (VMAT) due to shortened treatment time and intrafraction real-time monitoring provided by implanted radiofrequency(RF) transponders. The authors investigate dosimetrically driven action thresholds (whether treatment needs to be interrupted and patient repositioned) in VMAT treatment with electromagnetic (EM) tracking. Methods: VMAT plans for five patients are generated for prescription doses of 32.5 and 42.5 Gy in five fractions. Planning target volume (PTV) encloses the clinical target volume (CTV) with a 3 mm margin at the prostate-rectal interface and 5 mm elsewhere. The VMAT delivery is modeled using 180 equi-spaced static beams. Intrafraction prostate motion is simulated in the plan by displacing the beam isocenter at each beam assuming rigid organ motion according to a previously recorded trajectory of the transponder centroid. The cumulative dose delivered in each fraction is summed over all beams. Two sets of 57 prostate motion trajectories were randomly selected to form a learning and a testing dataset. Dosimetric end points including CTV D95%, rectum wall D1cc, bladder wall D1cc, and urethra Dmax, are analyzed against motion characteristics including the maximum amplitude of the anterior-posterior (AP), superior-inferior (SI), and left-right components. Action thresholds are triggered when intrafraction motion causes any violations of dose constraints to target and organs at risk (OAR), so that treatment is interrupted and patient is repositioned. Results: Intrafraction motion has a little effect on CTV D95%, indicating PTV margins are adequate. Tight posterior and inferior action thresholds around 1 mm need to be set in a patient specific manner to spare organs at risk, especially when the prescription dose is 42.5 Gy. Advantages of setting patient specific action thresholds are to reduce false positive alarms by 25% when prescription dose is low, and increase the sensitivity of detecting dose limits violations by 30% when prescription dose is high, compared to a generic 2 mm action box. The sensitivity and specificity calculated from the testing dataset are consistent to the learning set, which indicates that the patient specific approach is reliable and reproducible within the scope of the prostate database. Conclusions: This work introduces a formalism for ensuring a VMAT delivery meets the most clinically important dose requirements by using patient specific and dosimetric-driven action thresholds to hold the beam and reposition the patient when necessary. Such methods can provide improved sensitivity and specificity compared to conventional methods, which assume directionally symmetric action thresholds.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-250: New IMRT Sequencing Strategy: Towards Intra-Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT planning that during treatment makes the inclusion of external factors possible and by doing so accounts for intra-fraction anatomy changes. Given a real-time imaging modality that will provide the updated patient anatomy during delivery, this sequencer is able to take these changes into account during the calculation of subsequent segments. Methods: Pencil beams are generated for each beam angle of the treatment and a fluence optimization is performed. The pencil beams, together with the patient anatomy and the above optimal fluence form the input of our algorithm. During each iteration the following steps are performed: A fluence optimization is done and each beam's fluence is then split to discrete intensity levels. Deliverable segments are calculated for each one of these. Each segment's area multiplied by its intensity describes its efficiency. The most efficient segment among all beams is then chosen to deliver a part of the calculated fluence and the dose that will be delivered by this segment is calculated. This delivered dose is then subtracted from the remaining dose. This loop is repeated until 90% of the dose has been delivered and a final segment weight optimization is performed to reach full convergence. Results: This algorithm was tested in several prostate cases yielding results that meet all clinical constraints. Quality assurance was performed on Delta4 and film phantoms for one of these prostate cases and received clinical acceptance after passing both gamma analyses with the 3%/3mm criteria. Conclusion: A new sequencing algorithm was developed to facilitate the needs of intensity modulated treatment. The first results on static anatomy confirm that it can calculate clinical plans equivalent to those of the commercially available planning systems. We are now working towards 100% dose convergence which will allow us to handle anatomy deformations. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗

Laser Shock Modeling Archival Discussion

The purpose of this discussion is to provide archival information related to the Laser Shock finite element modeling effort. As discussed in Laser Shock System, Assessing bond strength in layered materials (see Section 8.0), the Laser Shock System creates a high-amplitude shockwave on the frontside of a structure (i.e. an aluminum 6061-T6 plate for this discussion) via a high-energy pulsed laser. The shock wave is monitored on the back surface of the structure as a velocity time history. It is a compressive wave as it comes to the back surface but reflects as a tensile wave. If a bond exists in the structure and the reflected tensile wave exceeds its interface threshold stress, then bond rupture occurs. The desire of the Laser Shock effort is to establish (with multiple tests) an ultimate bond strength which can be used for fuel plate design calculations. In this process, the finite element modeling effort is the catalyst to mimic the Laser Shock tests and provide the damage information at the bond that is useful for fuel plate design calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operating Dynamic Reserve Dimensioning Using Probabilistic Forecasts

The rapid integration of variable energy sources (VRES) into power grids increases variability and uncertainty of the net demand, making the power system operation challenging. Operating reserve is used by system operators to manage and hedge against such variability and uncertainty. Traditionally, reserve requirements are determined by rules-of-thumb (static reserve requirements, e.g., NERC Reliability Standards), and more recently, dynamic reserve requirements from tools and methods which are in the adoption process (e.g., DynADOR, DRD, and RESERVE, among others). While these methods/tools significantly improve the static rule-of-thumb approaches, they rely exclusively on deterministic data (i.e., best guess only). Consequently, these methods disregard the probabilistic uncertainty thresholds associated with specific days and their weather conditions (i.e., best guess plus probabilistic uncertainty). This work presents practical approaches to determine the operating reserve requirements leveraging the wealth information from probabilistic forecasts. Proposed approaches are validated and tested using actual data from the CAISO system. Furthermore, results show the benefits in terms of risk reduction of considering the probabilistic forecast information into the dimensioning process of operating reserve requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computed tomography dose measurements with radiochromic films and a flatbed scanner

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6x170 mm{sup 2} in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 deg. - 180 deg. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 deg.) and with the axis beam perpendicular (0 deg. and 180 deg.). Integrating over a 360 deg. exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 {sigma} level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 {sigma} level of 8% were founded. The 1 {sigma} uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 {sigma} uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Room Temperature Quasi-static Characterization and Constitutive Model Parametrization of Flexible Polyurethane Foams of Different Densities Loaded in Different Orientations

This report describes the efforts to characterize and model General Plastics TF6070 and EF4000 flexible polyurethane foams under room temperature, large deformation quasi-static cyclic mechanical loading conditions. Densities from three to fifteen pound per cubic foot (PCF) are examined, which correspond to relative densities of approximately 4 to 20%. These foams are open cell structured and flexible at room temperature with a glass transition transition less than -30°C, and they fully recover their original shape when unloaded (at room temperature). Uniaxial compression tests were conducted with accompanying lateral image series for Digital Image Correlation (DIC) analysis with the goal of extracting transverse strain responses. Due to difficulties with DIC analysis at large strains, lateral strains were instead extracted for each test via edge tracking. The experimental results exhibit a nonlinear elastic response and anisotropic material behavior (particularly for the lower densities). Some hysteresis is observed that is different between the first and subsequent cycles of deformation indicating both a small degree of permanent damage (reduced stiffness during reloading) and viscoelasticity. These inelastic mechanisms are not considered in the modeling and calibration in this report. This work considers only the rate independent, room temperature foam behavior. Individual foam densities were calibrated for loading in two directions, parallel and perpendicular to the foam bubble rise direction, since the mechanical behavior is different in these two directions. The Flex Foam constitutive model was used for all parameterizations despite the fact that the model is isotropic. A review of the constitutive model is given as well as necessary data reduction procedures to parameterize it for each foam density and orientation are discussed. Finally, two different parameterizations are developed that take the undeformed foam density as an input that span all densities considered. These two parameterized models represent foams loaded in the rise and transverse directions respectively. We summarize the assumptions and limitations of the parameterizations provided in this report to guide analysis choices with them. All parameterizations presented herein have the following traits, room temperature, rate independent, damage-free, and non-dissipative . Isotropy (even if they are representing anisotropic data). Supplied Sierra Solid Mechanics Flex Foam Model Inputs are in units: pounds, inches, Celsius, and seconds

36 MATERIALS SCIENCE↗

An optimization-based strategy for peridynamic-FEM coupling and for the prescription of nonlocal boundary conditions

We develop and analyze an optimization-based method for the coupling of a static peridynamic (PD) model and a static classical elasticity model. The approach formulates the coupling as a control problem in which the states are the solutions of the PD and classical equations, the objective is to minimize their mismatch on an overlap of the PD and classical domains, and the controls are virtual volume constraints and boundary conditions applied at the local-nonlocal interface. Our numerical tests performed on three-dimensional geometries illustrate the consistency and accuracy of our method, its numerical convergence, and its applicability to realistic engineering geometries. We demonstrate the coupling strategy as a means to reduce computational expense by confining the nonlocal model to a subdomain of interest, and as a means to transmit local (e.g., traction) boundary conditions applied at a surface to a nonlocal model in the bulk of the domain.

97 MATHEMATICS AND COMPUTING↗

DMTN-080: Coaddition Artifact Rejection and CompareWarp

LSST images will be contaminated with transient artifacts, such as optical ghosts, satellite trails, and cosmic rays, and with transient astronomical sources, such as asteroid ephemerides. We developed and tested an algorithm to find and reject these artifacts during coaddition, in order to produce clean coadds to be used for deep detection and preliminary object characterization. This algorithm, CompareWarpAssembleCoadd, uses the time-series of PSF-matched warped images to identify transient artifacts. It detects artifact candidates on the image differences between each PSF-matched warp and a static sky model. These artifact candidates include both true transient artifacts and difference-image false positives such as difficult-subtract-sources and variable sources such as stars and quasars. We use the feature that true transients appear at a given position in the difference images in only a small fraction (configurable) of visits, whereas variable sources and difficult-to-subtract sources appear in most difference images. In this report, we present a description of the method and an evaluation using Hyper SuprimeCam PDR1 data.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact Damage Behavior of Vinyl Ester-, Epoxy-, and Nylon 6-Based Basalt Fiber Composites

Composite laminates reinforced by woven basalt fibers and based on different polymer matrices were prepared and mechanically characterized, in static and dynamic conditions, to compare the results and evaluate the influence of the matrix type. In this regard, a thermoplastic resin, polyamide 6 (PA6), and two thermosetting matrices, vinyl ester and epoxy grades, commonly used for high-performance applications, were considered. Indentation depth measurements carried out by a confocal microscope and ultrasound analyses performed on specimens subjected to falling dart tests at levels of impact energies lower than the perforation one permitted to evaluate the extent of plastic deformations and of subjected delaminations, respectively. These data have provided useful information about the involved damage mechanisms and highlighted interesting perspective of use for the eco-friendly thermoplastic sample.

36 MATERIALS SCIENCE↗

Real-Time Profile Control for Advanced Tokamak Operation

Simultaneous control of the plasma shape, the magnetic and kinetic plasma profiles (such as the safety factor, q(x), and gyro-normalized temperature gradient, {rho}{sub Te}*;(x), respectively) and the boundary flux is being investigated on JET, and has potential applications in the operation of ITER steady state advanced tokamak discharges. The control of radially distributed parameters was achieved for the first time on JET in 2004 [1-4]. The controller was based on the static plasma response only. The approach newly implemented on JET aims to use a dynamical plasma model, all the available heating and current drive (H and CD) systems, and the poloidal field (PF) system in an optimal way to achieve a set of requested magnetic and kinetic profiles. This paper describes the new model-based optimal profile controller which has been tested during the last 2007 experimental campaign. The controller aims to use the combination of heating and current drive systems - and optionally the PF system. First experimental results of current profile control obtained during the last 2007 JET campaign are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Static dipole polarizabilities of polyacenes using self-interaction-corrected density functional approximations

Density functional approximations are known to significantly overestimate the polarizabilities of long chain-like molecules. We study the static electric dipole polarizabilities and the vertical ionization potentials of polyacenes from benzene to pentacene using the Fermi-L\"owdin orbital based self-interaction corrected (FLOSIC) density functional method. The orbital-by-orbital self-interaction correction corrects for the overestimation tendency of density functional approximations. The polarizabilities calculated with FLOSIC-DFA are however overly corrected. We also tested the recently developed locally-scaled self-interaction correction (LSIC) method on the polyacenes. The local-scaling method applies full SIC in the one-electron regions and restores the proper behavior of the SIC exchange-correlation functionals in the uniform density limit. The results show that LSIC removes the overcorrection tendency of the FLOSIC-DFA and produces results that are in excellent agreement with reference CCSD values. The vertical ionization potentials with LSIC also show good agreement with available experimental values.

74 ATOMIC AND MOLECULAR PHYSICS↗