Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Integrated Quantum-Classical Protocol for the Realistic Description of Solvated Multinuclear Mixed-Valence Transition-Metal Complexes and Their Solvatochromic Properties

Linear cyanide-bridged polymetallic complexes, which undergo photoinduced metal-to-metal charge transfer, represent prototypical systems for studying long-range electron-transfer reactions and understanding the role played by specific solute–solvent interactions in modulating the excited-state dynamics. Here, to tackle this problem, while achieving a statistically meaningful description of the solvent and of its relaxation, one needs a computational approach capable of handling large polynuclear transition-metal complexes, both in their ground and excited states, as well as the ability to follow their dynamics in several environments up to nanosecond time scales. Here, we present a mixed quantum classical approach, which combines large-scale molecular dynamics (MD) simulations based on an accurate quantum mechanically derived force field (QMD-FF) and self-consistent QMD polarized point charges, with IR and UV–vis spectral calculations to model the solvation dynamics and optical properties of a cyano-bridged trinuclear mixed-valence compound (trans-[(NC) 5 Fe III (μ-CN)Ru II (pyridine) 4 (μ-NC)Fe III (CN) 5 ] 4– ). We demonstrate the reliability of the QMD-FF/MD approach in sampling the solute conformational space and capturing the local solute–solvent interactions by comparing the results with higher-level quantum mechanics/molecular mechanics (QM/MM) MD reference data. The IR spectra calculated along the classical MD trajectories in different solvents correctly predict the red shift of the CN stretching band in the aprotic medium (acetonitrile) and the subtle differences measured in water and methanol, respectively. By explicitly including the solvent molecules around the cyanide ligands and calculating the thermal averaged absorption spectra using time-dependent density functional theory calculations within the Tamm–Dancoff approximation, the experimental solvatochromic shift is quantitatively reproduced going from water to methanol, while it is overestimated for acetonitrile. This discrepancy can likely be traced back to the lack of important dispersion interactions between the solvent cyano groups and the pyridine substituents in our micro solvation model. The proposed protocol is applied to the ground state in water, methanol, and acetonitrile and can be flexibly generalized to study excited-state nonequilibrium solvation dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shape-shifting Elephants: Multi-modal Transport for Integrated Research Infrastructure

Data Acquisition (DAQ) workloads form an important class of scientific network traffic that by its nature (1) flows across different research infrastructure, including remote instruments and supercomputer clusters, (2) has ever-increasing throughput demands, and (3) has ever-increasing integration demands---for example, observations at one instrument could trigger a reconfiguration of another instrument. Today's DAQ transfers rely on UDP and (heavily tuned) TCP, but this is driven by convenience rather than suitability. The mismatch between Internet transport protocols and scientific workloads becomes more stark with the steady increase in link capacities, data generation, and integration across research infrastructure.This position paper argues the importance of developing specialized transport protocols for DAQ workloads. It proposes a new transport feature for this kind of elephant flow: multi-modality involves the network actively configuring the transport protocol to change how DAQ flows are processed across different underlying networks that connect scientific research infrastructure. Multi-modality is a layering violation that is proposed as a pragmatic technique for DAQ transport protocol design. It takes advantage of programmable network hardware that is increasingly being deployed in scientific research infrastructure. The paper presents an initial evaluation through a pilot study that includes a Tofino2 switch and Alveo FPGA cards, and using data from a particle detector.

97 MATHEMATICS AND COMPUTING↗

Protocols and methodologies for acquiring and analyzing critical-current versus longitudinal-strain data in Bi 2 Sr 2 CaCu 2 O 8+x wires

Abstract In the literature on Bi 2 Sr 2 CaCu 2 O 8+ x (Bi-2212) superconducting wires, it is evident that measurement protocols for transport critical-current I c versus longitudinal strain ϵ and definitions of the so-called ‘strain limit’ are generally dissimilar. Yet, values obtained for the ‘strain limit’ are frequently assimilated to being those of the irreversible strain limit ϵ irr , regardless of the I c degradation-criterion used to define it. In effect, ϵ irr should correspond specifically to the I c ( ϵ ) irreversibility onset , where crack formation in Bi-2212 filaments presumably starts. Because I c ( ϵ ) degradation remains progressive over a fairly wide strain range beyond ϵ irr , the different I c degradation-criteria in use do not yield to the same result and, thus, are not equivalent from metrology perspective. Indeed, in studying densified samples of a modern Bi-2212 round wire, we found ϵ irr ≈ 0.4% and ϵ 5% ≈ 0.6% ( ϵ 5% being the strain where I c degrades by 5%). In this paper, we outline and suggest I c ( ϵ )-measurement protocols and data-analysis methodologies in the hope to converge the various approaches taken for studying Bi-2212 strain properties and, thus, remove related result discrepancies. A unified approach would enable more objective data comparisons among laboratories and among different Bi-2212 conductors. It would pave the way for more rigorous studies of effects potentially associated with wire design, powder, heat treatments, and other such parameters on the conductor’s strain properties.

protocols↗

Scrambling and thermalization in a diffusive quantum many-body system

Out-of-time ordered (OTO) correlation functions describe scrambling of information in correlated quantum matter. They are of particular interest in incoherent quantum systems lacking well defined quasi-particles. Thus far, it is largely elusive how OTO correlators spread in incoherent systems with diffusive transport governed by a few globally conserved quantities. Here, we study the dynamical response of such a system using high-performance matrix-product-operator techniques. Specifically, we consider the non-integrable, one-dimensional Bose–Hubbard model in the incoherent high-temperature regime. Our system exhibits diffusive dynamics in time-ordered correlators of globally conserved quantities, whereas OTO correlators display a ballistic, light-cone spreading of quantum information. The slowest process in the global thermalization of the system is thus diffusive, yet information spreading is not inhibited by such slow dynamics. We furthermore develop an experimentally feasible protocol to overcome some challenges faced by existing proposals and to probe time-ordered and OTO correlation functions. As a result, our study opens new avenues for both the theoretical and experimental exploration of thermalization and information scrambling dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

Optimizing Single Nuclei Sequencing of Brain Samples From Space Flown Mice Across Age and Strain

The NASA GeneLab Sample Processing Laboratory offers high-throughput sequencing services to NASA-funded space biology researchers. Space biology studies have specific challenges such as low sample numbers, introducing susceptibility to batch effects from sample handling. These issues are compounded by complex protocols such as single-nuclei isolation and sequencing, which has recently become an attractive methodology for assessing the cellular diversity within spaceflight samples. High quality single-nuclei sequencing requires reproducible protocols to dissociate tissue and generate clean suspension of intact single nuclei. Producing single-nuclei suspension from brain tissue is particularly challenging due to cell type heterogeneity and the myelin sheath that carries over into the nuclei suspension as debris. Current procedures tend to be time consuming and sometimes include steps that can alter gene expression and create cell-type bias. Commercially available nuclei isolation kits, such as the 10X Genomics nuclei isolation kit, offers a streamlined way to process samples for nuclei isolation, thereby minimizing batch effects and enabling reproducibility. In this study, we report on the performance of the 10X Genomics nuclei isolation kit and Chromium Next GEM Single Cell Multiome ATAC + Gene Expression kit to generate sequencing libraries from space-flown mouse brain samples. Single nuclei sequencing was performed on frozen mouse brain tissue from two spaceflight missions, Rodent Research-10 (RR-10) and RR Reference Mission-2 (RRRM-2). RR-10 mice were female B6129SF2/J, euthanized at 18-19 weeks whereas RRRM-2 mice were female C57BL/6NTac, euthanized at 20 or 37 weeks. Sequencing data was processed using standard GeneLab data processing pipelines. We report evaluation of the performance of the 10X Genomics nuclei isolation kit for spaceflight samples from mouse brain, and evaluation of reproducibility across different mouse strains and age groups. We also report preliminary scientific results including cell type inference, cell clustering, and differentially expressed genes and pathways between spaceflight and ground control samples.

RR-10↗

Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy

Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)- dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation.

Matsushita, Katsuyuki↗

Environmental Stress Testing of the Single Sample Cylinder: A Proven Consensus Standard for Internal Gas Analysis (IGA) or Residual Gas Analysis (RGA)

In August 2008, Schuessler Consulting was contracted by NASA GSFC in support of the NASA Electronic Parts and Packaging (NEPP) program to perform two separate studies on moisture laden air in a stainless steel cylinder that had been designed to become a consensus standard for Test Method 1018. This Test Method was originally released for hybrids under Mil. Std. 883 but was quickly utilized on other microelectronic devices under the auspice of Mil. Std. 750. The cylinder had subsequently been fabricated for the 750 community. It was back-filled with moist air and subsequently analyzed over a period of time under a previous NASA contract. It had been shown that moisture in the 4000 - 5000 ppm range could be analyzed rather precisely with a mass spectrometer, commonly referred to as a Residual Gas Analyzer (RGA). The scope of this study was to ascertain if the composition and precision varied as a function of thermal shock at sub-zero temperatures and whether there was consensus when the standard was submitted to other RGA units. It was demonstrated and published that the consensus standard would yield precise RGA data for moisture within +/- 1% when optimized for a given RGA unit. It has been subsequently shown in this study at Oneida Research Services, that sub-zero storage did not affect that precision when a well-defined protocol for the analysis was followed. The consensus standard was taken to a second facility for analysis where it was found that moisture adsorption on the transfer lines caused precision to drop to +/- 12%. The Single Sample Cylinder (SSC) is a one liter stainless steel cylinder with associated sampling valves and has considerable weight and volume. But this considerable size allows for approximately 300 gas samples of the same composition to be delivered to any RGA unit. Lastly, a smaller cylinder, approximately 75 cc, of a second consensus standard was fabricated and tested with a different mix of fixed gases where moisture was kept in the 100 ppm range. This second standard has the potential of providing 30 gaseous samples and can be readily shipped to any analytical facility that desires to generate comparison RGA data. A series of comparison residual gas analyses was performed at the Honeywell Federal Manufacturing & Technologies facility in the National Nuclear Facility Administration s plant in Kansas City to complete this project. It was shown that improvements in the precision of a given RGA unit can be done by controlling the cycle time for each analysis and increasing analysis temperatures to minimize moisture adsorption. It was also found that a "one time event" in the subzero storage of the large SSC did not effect the units ability to continuously supply precise samples of the same chemistry, however the "event" caused a permanent +8% shift in the reported value of the moisture content. Lastly, a set of SSC RGA results was plotted on a common graph with DSCC "correlation study" RGA data. The result demonstrates the ability of the SSC to remove many of the individual variances that single, individual samples introduce. The consensus standards are now in storage at Oneida Research Services, one of the DSCC certified houses that does RGA to Military Standards, where they await future studies. The analytical data and the operational parameters of the instruments used are provided in the following discussion. Limitations and suggested means for improvement of both precision and accuracy are provided.

Schuessler, Philipp WH↗

Hamiltonian switching control of noisy bipartite qubit systems

Abstract We develop a Hamiltonian switching ansatz for bipartite control that is inspired by the quantum approximate optimization algorithm, to mitigate environmental noise on qubits. We demonstrate the control for a central spin coupled to bath spins via isotropic Heisenberg interactions, and then make physical applications to the protection of quantum gates performed on superconducting transmon qubits coupling to environmental two-level-systems (TLSs) through dipole-dipole interactions, as well as on such qubits coupled to both TLSs and a Lindblad bath. The control field is classical and acts only on the system qubits. We use reinforcement learning with policy gradient to optimize the Hamiltonian switching control protocols, using a fidelity objective for specific target quantum gates. We use this approach to demonstrate effective suppression of both coherent and dissipative noise, with numerical studies achieving target gate implementations with fidelities over 0.9999 (four nines) in the majority of our test cases and showing improvement beyond this to values of 0.999 999 999 (nine nines) upon a subsequent optimization by GRadient Ascent Pulse Engineering (GRAPE). We analyze how the control depth, total evolution time, number of environmental TLS, and choice of optimization method affect the fidelity achieved by the optimal protocols and reveal some critical behaviors of bipartite control of quantum gates.

Physics↗

Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.

60 APPLIED LIFE SCIENCES↗

Timeouts Best Practices

This study investigates common timeouts encountered in the electric vehicle (EV) charging communications process. Many different timeouts are defined within the EV charging communications protocols. These timeouts can either be a fixed value or a defined range of values. In both cases, the timeout defines the duration of time for which one or both parties in the communications session are expected to wait for some action or process to complete before terminating the charge attempt. These timeout-based terminations are intended to prevent the charging process from becoming stuck indefinitely in any particular step. These terminations also enable a retry of the terminated charging session to begin. However, misaligned timeout values can have a significant negative impact on the user experience. Premature termination of charging sessions due to inappropriate timeout settings can lead to charging failures, causing inconvenience, wasted time, and frustration for users. These disruptions can degrade the overall user experience, making it essential to carefully manage and align timeout values with the relevant actions and processes to ensure reliable and satisfactory EV charging sessions. The core objective of this study is to boost reliability and enhance user experience by conducting a thorough review of timeout-based issues in EV charging and delivering a set of recommendations to modify these existing timeouts. These recommendations are informed by feedback gathered from multiple EV charging partners. This document is intended to inform electric vehicle supply equipment (EVSE) and EV manufacturers, EV charging infrastructure developers, and policymakers responsible for designing and implementing EV charging protocols and systems.

33 ADVANCED PROPULSION SYSTEMS↗

Community standards and future opportunities for synthetic communities in plant–microbiota research

Harnessing beneficial microorganisms is seen as a promising approach to enhance sustainable agriculture production. Synthetic communities (SynComs) are increasingly being used to study relevant microbial activities and interactions with the plant host. Yet, the lack of community standards limits the efficiency and progress in this important area of research. Here, to address this gap, we recommend three actions: (1) defining reference SynComs; (2) establishing community standards, protocols and benchmark data for constructing and using SynComs; and (3) creating an infrastructure for sharing strains and data. We also outline opportunities to develop SynCom research through technical advances, linking to field studies, and filling taxonomic blind spots to move towards fully representative SynComs.

59 BASIC BIOLOGICAL SCIENCES↗

Local Control With Reduced-Dose Radiotherapy for Low-Risk Rhabdomyosarcoma: A Report From the Children's Oncology Group D9602 Study

Purpose: To analyze the effect of reduced-dose radiotherapy on local control in children with low-risk rhabdomyosarcoma (RMS) treated in the Children's Oncology Group D9602 study. Methods and Materials: Patients with low-risk RMS were nonrandomly assigned to receive radiotherapy doses dependent on the completeness of surgical resection of the primary tumor (clinical group) and the presence of involved regional lymph nodes. After resection, most patients with microscopic residual and uninvolved nodes received 36 Gy, those with involved nodes received 41.4 to 50.4 Gy, and those with orbital primary tumors received 45 Gy. All patients received vincristine and dactinomycin, with cyclophosphamide added for patient subsets with a higher risk of relapse in Intergroup Rhabdomyosarcoma Study Group III and IV studies. Results: Three hundred forty-two patients were eligible for analysis; 172 received radiotherapy as part of their treatment. The cumulative incidence of local/regional failure was 15% in patients with microscopic involved margins when cyclophosphamide was not part of the treatment regimen and 0% when cyclophosphamide was included. The cumulative incidence of local/regional failure was 14% in patients with orbital tumors. Protocol-specified omission of radiotherapy in girls with Group IIA vaginal tumors (n = 5) resulted in three failures for this group. Conclusions: In comparison with Intergroup Rhabdomyosarcoma Study Group III and IV results, reduced-dose radiotherapy does not compromise local control for patients with microscopic tumor after surgical resection or with orbital primary tumors when cyclophosphamide is added to the treatment program. Girls with unresected nonbladder genitourinary tumors require radiotherapy for postsurgical residual tumor for optimal local control to be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biophysical analysis of the plant-specific GIPC sphingolipids reveals multiple modes of membrane regulation

The plant plasma membrane (PM) is an essential barrier between the cell and the external environment, controlling signal perception and transmission. It consists of an asymmetrical lipid bilayer made up of three different lipid classes: sphingolipids, sterols, and phospholipids. The glycosyl inositol phosphoryl ceramides (GIPCs), representing up to 40% of total sphingolipids, are assumed to be almost exclusively in the outer leaflet of the PM. However, their biological role and properties are poorly defined. In this study, we investigated the role of GIPCs in membrane organization. Because GIPCs are not commercially available, we developed a protocol to extract and isolate GIPC-enriched fractions from eudicots (cauliflower and tobacco) and monocots (leek and rice). Lipidomic analysis confirmed the presence of trihydroxylated long chain bases and 2-hydroxylated very long-chain fatty acids up to 26 carbon atoms. The glycan head groups of the GIPCs from monocots and dicots were analyzed by gas chromatograph-mass spectrometry, revealing different sugar moieties. Multiple biophysics tools, namely Langmuir monolayer, ζ-Potential, light scattering, neutron reflectivity, solid state 2H-NMR, and molecular modeling, were used to investigate the physical properties of the GIPCs, as well as their interaction with free and conjugated phytosterols. We showed that GIPCs increase the thickness and electronegativity of model membranes, interact differentially with the different phytosterols species, and regulate the gel-to-fluid phase transition during temperature variations. These results unveil the multiple roles played by GIPCs in the plant PM.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental Approach to Controllably Vary Protein Oxidation While Minimizing Electrode Adsorption for Boron-Doped Diamond Electrochemical Surface Mapping Applications

Oxidative protein surface mapping has become a powerful approach for measuring the solvent accessibility of folded protein structures. A variety of techniques exist for generating the key reagent hydroxyl radicals for these measurements; however, many of these approaches require use of radioactive sources or caustic oxidizing chemicals. The purpose of this research was to evaluate and optimize the use of boron-doped diamond (BDD) electrochemistry as a highly accessible tool for producing hydroxyl radicals as a means to induce a controllable level of oxidation on a range of intact proteins. These experiments utilize a relatively high flow rates to reduce protein residence time inside the electrochemical flow chamber, along with a unique cell activation approach to improve control over the intact protein oxidation yield. Studies were conducted to evaluate the level of protein adsorption onto the electrode surface. This report demonstrates a robust protocol for the use of BDD electrochemistry and high performance LC-MS/MS as a high-throughput experimental pipeline for probing higher order protein structure, and illustrates how it is complementary to predictive computational modeling efforts.

boron-doped diamond electrochemistry↗

Engineering the formation of spin-defects from first principles

The full realization of spin qubits for quantum technologies relies on the ability to control and design the formation processes of spin defects in semiconductors and insulators. We present a computational protocol to investigate the synthesis of point-defects at the atomistic level, and we apply it to the study of a promising spin-qubit in silicon carbide, the divacancy (VV). Our strategy combines electronic structure calculations based on density functional theory and enhanced sampling techniques coupled with first principles molecular dynamics. We predict the optimal annealing temperatures for the formation of VVs at high temperature and show how to engineer the Fermi level of the material to optimize the defect’s yield for several polytypes of silicon carbide. Our results are in excellent agreement with available experimental data and provide novel atomistic insights into point defect formation and annihilation processes as a function of temperature.

36 MATERIALS SCIENCE↗

Elaborated thermochemical treatment of HF, CO, N 2 , and H 2 O: Insight into HEAT and its extensions

Here, empirical, highly accurate non-relativistic electronic total atomization energies (eTAEs) are established by combining experimental or computationally converged treatments of the nuclear motion and relativistic contributions with the total atomization energies of HF, CO, N 2 , and H 2 O obtained from the Active Thermochemical Tables. These eTAEs, which have estimated (2σ) uncertainties of less than 10 cm -1 (0.12 kJ mol -1 ), form the basis for an analysis of high-level ab initio quantum chemical calculations that aim at reproducing these eTAEs for the title molecules. The results are then employed to analyze the performance of the high-accuracy extrapolated ab initio thermochemistry, or High-Accuracy Extrapolated Ab Initio Thermochemistry (HEAT), family of theoretical methods. The method known as HEAT-345(Q), in particular, is found to benefit from fortuitous error cancellation between its treatment of the zero-point energy, extrapolation errors in the Hartree-Fock and coupled cluster contributions, neglect of post-(T) core-correlation, and the basis-set error involved in higher-level correlation corrections. In addition to shedding light on a longstanding curiosity of the HEAT protocol—where the cheapest HEAT-345(Q) performs comparably to the theoretically more complete HEAT-456QP procedure—this study lays the foundation for extended HEAT variants that offer substantial improvements in accuracy relative to the established approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Approaches for a quantum memory at telecommunication wavelengths

We report experimental storage and retrieval of weak coherent states of light at telecommunication wavelengths using erbium ions doped into a solid. We use two photon-echo-based quantum storage protocols. The first one is based on controlled reversible inhomogeneous broadening (CRIB). It allows the retrieval of the light on demand by controlling the collective atomic coherence with an external electric field, via the linear Stark effect. We study how atoms in the excited state affect the signal-to-noise ratio of the CRIB memory. Additionally we show how CRIB can be used to modify the temporal width of the retrieved light pulse. The second protocol is based on atomic frequency combs. Using this protocol we verify that the reversible mapping is phase preserving by performing an interference experiment with a local oscillator. These measurements are enabling steps toward solid-state quantum memories at telecommunication wavelengths. We also give an outlook on possible improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗