At least 1,135 records · Page 63

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Urine sampling and collection system

This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

Fogal, G. L.↗

First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g{sup -1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power. Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 3: Commands specification

This volume (3 of 4) contains the specification for the command language for the AMPS system. The volume contains a requirements specification for the operating system and commands and a design specification for the operating system and command. The operating system and commands sits on top of the protocol. The commands are an extension of the present set of AMPS commands in that the commands are more compact, allow multiple sub-commands to be bundled into one command, and have provisions for identifying the sender and the intended receiver. The commands make no change to the actual software that implement the commands.

Mckee, James W.↗

Performance Specification for Standardized Transportation, Aging, and Disposal Canister Systems (Rev.2)

This performance specification document addresses use of a standardized transportation, aging, and disposal (STAD) canister system in the spent nuclear fuel (SNF) waste management system. This document was developed to support STAD canister system studies and potential research, development, and demonstration activities. Requirements in this specification may evolve with time based on results from analyses, experiments, design studies, system evaluations and demonstrations, as well as other factors. A STAD canister system consists of a canister, together with a storage or aging overpack/module/vault, a shielded transfer cask (STC), a site transporter, a transportation overpack, and a transportation skid. Three sizes of circular cross section STAD canister variants are specified in this document. The small STAD canister capacity is four pressurized water reactor (PWR) or nine boiling water reactor (BWR) SNF assemblies. The medium STAD canister capacity is 12 PWR or 32 BWR SNF assemblies. The large STAD canister capacity is 21 PWR or 44 BWR SNF assemblies. Using standardized canisters for SNF facilitates the interface between storage at an independent spent fuel storage installation (ISFSI) or a DOEowned interim storage facility (ISF), transportation between facilities, and disposal at a repository. Multiple STAD canisters may be stored in a single storage overpack and/or a single transportation overpack. The US Nuclear Regulatory Commission (NRC) requirements currently used for storage and transportation are adopted for the STAD canister system. Approved approaches (guidance) in NRC storage and transportation documents are also adopted as requirements for the STAD canister system to facilitate obtaining NRC Certificates of Compliance (CoCs) for STAD canister systems. Performance specifications in this document are also informed by STAD canister disposability in various geologic media and consideration of ISF (and geologic repository) handling facility design, operations, and licensing requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-performance optical disk mass storage for aerospace imaging systems

The specifications and techniques related to the development of the NASA Spaceflight Optical Disk Recorder (SODR) are presented. The system is being developed for the temporary storage of high-resolution sensor data that will be collected at high data rates by future space programs. Typical spaceflight recording requirements are given for the Space Station Freedom, the Earth Observing System, and some planetary missions. SODR module characteristics are listed, emphasizing the two independent optical disk recorders and the random access to 5 gigabytes of data on each side of the disks. The modular design includes two I/O ports providing 150 Mbits/sec user data rate each, and multimodule reconfigurable architecture permitting the synchronization of up to 16 modules with a maximum data rate of 4.8 gigabits/sec.

Ravner, Stephen M.↗

Pulsed High Power Calibration System

This specification defines the minimum requirements for the manufacture, performance, and acceptance of a 10 kA Pulsed High Power Calibration System capable of output pulsed current with durations ranging from 1us to 100 us and currents ranging from 0.1 Amperes to 10,000 Amperes.

42 ENGINEERING↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

Criticality calculation of non-ordinary systems

The specific features of calculation of the effective multiplication factor using the Monte Carlo method for weakly coupled and non-asymptotic multiplying systems are discussed. Particular examples are considered and practical recommendations on detection and Monte Carlo calculation of systems typical in numerical substantiation of nuclear safety for VVER fuel management problems are given. In particular, the problems of the choice of parameters for the batch mode and the method for normalization of the neutron batch, as well as finding and interpretation of the eigenvalue spectrum for the integral fission matrix, are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Anti-Pdc1p Nanobody as a Genetically Encoded Inhibitor of Ethanol Production Enables Dual Transcriptional and Post-translational Controls of Yeast Fermentations

Microbial fermentation provides a sustainable method of producing valuable chemicals. Adding dynamic control to fermentations can significantly improve titers, but most systems rely on transcriptional controls of metabolic enzymes, leaving existing intracellular enzymes unregulated. This limits the ability of transcriptional controls to switch off metabolic pathways, especially when metabolic enzymes have long half-lives. We developed a two-layer transcriptional/post-translational control system for yeast fermentations. Specifically, the system uses blue light to transcriptionally activate the major pyruvate decarboxylase PDC1, required for cell growth and concomitant ethanol production. Switching to darkness transcriptionally inactivates PDC1 and instead activates the anti-Pdc1p nanobody, NbJRI, to act as a genetically encoded inhibitor of Pdc1p accumulated during the growth phase. This dual transcriptional/post-translational control improves the production of 2,3-BDO and citramalate by up to 100 and 92% compared to using transcriptional controls alone in dynamic two-phase fermentations. Furthermore, this study establishes the NbJRI nanobody as an effective genetically encoded inhibitor of Pdc1p that can enhance the production of pyruvate-derived chemicals.

59 BASIC BIOLOGICAL SCIENCES↗

Data for "Anti-Pdc1p Nanobody as a Genetically Encoded Inhibitor of Ethanol Production Enables Dual Transcriptional and Post-translational Controls of Yeast Fermentations"

Microbial fermentation provides a sustainable method of producing valuable chemicals. Adding dynamic control to fermentations can significantly improve titers, but most systems rely on transcriptional controls of metabolic enzymes, leaving existing intracellular enzymes unregulated. This limits the ability of transcriptional controls to switch off metabolic pathways, especially when metabolic enzymes have long half-lives. We developed a two-layer transcriptional/post-translational control system for yeast fermentations. Specifically, the system uses blue light to transcriptionally activate the major pyruvate decarboxylase PDC1 , required for cell growth and concomitant ethanol production. Switching to darkness transcriptionally inactivates PDC1 and instead activates the anti-Pdc1p nanobody, NbJRI, to act as a genetically encoded inhibitor of Pdc1p accumulated during the growth phase. This dual transcriptional/post-translational control improves the production of 2,3-BDO and citramalate by up to 100 and 92% compared to using transcriptional controls alone in dynamic two-phase fermentations. This study establishes the NbJRI nanobody as an effective genetically encoded inhibitor of Pdc1p that can enhance the production of pyruvate-derived chemicals.

metabolic engineering↗

Rapid, Approximate Multi-Axis Vibration Testing [Thesis]

The aerospace industry uses vibration shaker tables to perform component durability testing. In these tests a component, piece of equipment, or entire system is attached to a shaker table where it is subjected to dynamic excitation. The goal is to understand how the article under test will perform in its service environment without having to run it through its entire service life via field testing. In a vibration test, an aerospace system or component is qualified if it is shown to survive a test meant to replicate its lifetime service conditions. The test is designed based on recorded field data. To develop a test, a system is taken through all of its intended environments, e.g., transportation, launch, and reentry. Acceleration data measured from these environments is then brought back to the lab and imported into a shaker table controller. The controller then drives a vibration test intended to mimic the acceleration conditions experienced by the system or specific components of the system in the field. However, it is often difficult to match the measured field response in a lab test. This is largely due to the test’s boundary conditions and excitation methods. In a lab test, a shaker table is the excitation source. The two most common shaker table types, differentiated by their number of independent degrees of freedom, are single-axis and multi-axis shaker tables. Multi-axis shakers have the ability to reproduce service environments more realistically, as real accelerations inevitably produce multiple degrees of freedom of excitation simultaneously. Figure 1 depicts a generic multi-axis testing setup on a three-axis shaker table. Often multi-axis tests use six-degree-of-freedom (6DOF) shaker tables. Yet multi-axis shakers are not yet common in the aerospace industry due in part to their high cost and the difficulty for shaker controllers to handle the added complexity. Single-axis shaker tables are much more common. They are not as expensive to purchase and have a wide range of control software options.

42 ENGINEERING↗

Two techniques for eliminating luminol interference material and flow system configurations for luminol and firefly luciferase systems

Two methods for eliminating luminol interference materials are described. One method eliminates interference from organic material by pre-reacting a sample with dilute hydrogen peroxide. The reaction rate resolution method for eliminating inorganic forms of interference is also described. The combination of the two methods makes the luminol system more specific for bacteria. Flow system designs for both the firefly luciferase and luminol bacteria detection systems are described. The firefly luciferase flow system incorporating nitric acid extraction and optimal dilutions has a functional sensitivity of 3 x 100,000 E. coli/ml. The luminol flow system incorporates the hydrogen peroxide pretreatment and the reaction rate resolution techniques for eliminating interference. The functional sensitivity of the luminol flow system is 1 x 10,000 E. coli/ml.

Thomas, R. R.↗

NASA space power system automation

Investigations were conducted with the objective to identify technology issues in automating space power systems, rank critical technology needs, and recommend technology objectives. It was found that automation can offer significant benefits to space power systems. Automation, or even autonomy, may become an absolute requirement for system implementation. Automation of large power systems will be achieved through evolution. It is pointed out that 'systems engineering' or more specifically, 'automation systems engineering' must be strongly emphasized and done early in the development process. System control can be centralized, distributed or a combination of the two. An important requirement for automation implementation is related to the availability of qualified hardware and software components.

Wagnon, F. W.↗

An implementation of the distributed programming structural synthesis system (PROSSS)

A method is described for implementing a flexible software system that combines large, complex programs with small, user-supplied, problem-dependent programs and that distributes their execution between a mainframe and a minicomputer. The Programming Structural Synthesis System (PROSSS) was the specific software system considered. The results of such distributed implementation are flexibility of the optimization procedure organization and versatility of the formulation of constraints and design variables.

Rogers, J. L., Jr.↗