Exploring battery material failure mechanisms through synchrotron X-ray characterization techniques

Rechargeable battery cycling performance and related safety have been persistent concerns. Here, it is crucial to decipher the capacity fading induced by electrode material failure via a range of techniques. Among these, synchrotron-based X-ray techniques with high flux and brightness play a key role in understanding degradation mechanisms. In this comprehensive review, we summarized recent advancements in degradation modes and mechanisms that revealed by synchrotron X-ray methodologies. Subsequently, an overview of X-ray absorption spectroscopy and X-ray scattering techniques are introduced for the characterizing failure phenomena at local coordination atomic environment and long-range order crystal structure scale, respectively. At last, we envision the future of material failure mechanism exploration.

25 ENERGY STORAGE↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of multiple methane emission sources at landfills using a double tracer technique

Research highlights: > Precise and reliable measurements of emissions from landfills are needed. > A tracer technique involving simultaneous release of two tracers was proven successful. > Measurements to be performed at times with low changing trends in barometric pressure. - Abstract: A double tracer technique was used successfully to quantify whole-site methane (CH{sub 4}) emissions from Fakse Landfill. Emissions from different sections of the landfill were quantified by using two different tracers. A scaled-down version of the tracer technique measuring close-by to localized sources having limited areal extent was also used to quantify emissions from on-site sources at the landfill facility, including a composting area and a sewage sludge storage pit. Three field campaigns were performed. At all three field campaigns an overall leak search showed that the CH{sub 4} emissions from the old landfill section were localized to the leachate collection wells and slope areas. The average CH{sub 4} emissions from the old landfill section were quantified to be 32.6 {+-} 7.4 kg CH{sub 4} h{sup -1}, whereas the source at the new section was quantified to be 10.3 {+-} 5.3 kg CH{sub 4} h{sup -1}. The CH{sub 4} emission from the compost area was 0.5 {+-} 0.25 kg CH{sub 4} h{sup -1}, whereas the carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O) flux was quantified to be in the order of 332 {+-} 166 kg CO{sub 2} h{sup -1} and 0.06 {+-} 0.03 kg N{sub 2}O h{sup -1}, respectively. The sludge pit located west of the compost material was quantified to have an emission of 2.4 {+-} 0.63 kg h{sup -1} CH{sub 4}, and 0.03 {+-} 0.01 kg h{sup -1} N{sub 2}O.

54 ENVIRONMENTAL SCIENCES↗

Diagnostic techniques for measuring suprathermal electron dynamics in plasmas (invited)

Plasmas, both in the laboratory and in space, are often not in thermodynamic equilibrium, and the plasma electron distribution function is accordingly non-Maxwellian. Suprathermal electron tails can be generated by external drives, such as rf waves and electric fields, or internal ones, such as instabilities and magnetic reconnection. The variety and importance of the phenomena in which suprathermal electrons play a significant role explains an enduring interest in diagnostic techniques to investigate their properties and dynamics. X-ray bremsstrahlung emission has been studied in hot magnetized plasmas for well over two decades, flanked progressively by electron-cyclotron emission in geometries favoring the high-energy end of the distribution function (high-field-side, vertical, oblique emission), by electron-cyclotron absorption, by spectroscopic techniques, and at lower temperatures, by Langmuir probes and electrostatic analyzers. Continuous progress in detector technology and in measurement and analysis techniques, increasingly sophisticated layouts (multichannel and tomographic systems, imaging geometries), and highly controlled suprathermal generation methods (e.g., perturbative rf modulation) have all been brought to bear in recent years on an increasingly detailed, although far from complete, understanding of suprathermal electron dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Image And X-Ray Microtomography Technique To Quantify Filler Distribution In Thermoplastic-Natural Rubber Blend Composites

X-ray microtomography and ImageJ 1.39 u is used as a tool to quantify volume percentage of B{sub 4}C as fillers in thermoplastic-natural rubber blend composites. The use of percentage of area occupied by fillers as obtain from ImageJ from the microtomography sliced images enables the proposed technique to easily obtain the amount volume percentage of B{sub 4}C in the composite non-destructively. Comparison with other technique such as density measurement and chemical analysis proves the proposed technique as one of the promising approach.

36 MATERIALS SCIENCE↗

NEW DEVELOPMENTS IN DIGITAL X-RAY TECHNIQUES: A SIMULATION TOOL FOR SCATTERING IMAGING

This paper focus mainly on a simulation tool used to compute X-ray imaging technique and the last developments with the calculation of the scattering. It allows evaluating the scattered contribution on a transmission detector but also simulating scattering technique as Compton or Rayleigh tomography. A major interest of the Compton scattering technique is that the experimental device is located on one side of the object, and thus, an image can be acquired even if we can not access to the other side of the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of novel fuel ion ratio diagnostic techniques

To overcome the challenge of measuring the fuel ion ratio in the core ({rho}<0.3) of ITER, a coordinated effort aiming at developing diagnostic techniques has been initiated. The investigated techniques are novel uses or further development of existing methods such as charge exchange recombination spectrometry, neutron spectrometry, and collective Thomson scattering. An overview of the work on the three diagnostic techniques is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Technique for Identifying Gamma Detector Candidates

Recent demands for radiation detector materials with better energy resolution at room temperature have prompted research efforts on both accelerated material discovery and efficient analysis techniques. Ions can easily deposit their energy in thin films or small crystals and the radiation response can be used to identify material properties relevant to detector performance. In an effort to identify gamma detector candidates using small crystals or film samples, an ion technique is developed to measure relative light yield and energy resolution of candidate materials and to evaluate radiation detection performance. Employing a unique time-of-flight (TOF) telescope, light yield and energy resolution resulting from ion excitation are investigated over a continuous energy region. The efficiency of this ion technique is demonstrated using both organic (plastic scintillator) and inorganic (CaF2:Eu, YAP:Ce, CsI:Tl and BGO) scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Reduction Techniques for Simulation, Visualization and Data Analysis

Data reduction is increasingly being applied to scientific data for numerical simulations, scientific visualizations, and data analyses. It is most often used to lower I/O and storage costs, and sometimes to lower in-memory data size as well. With this work, we consider five categories of data reduction techniques based on their information loss: 1) truly lossless, 2) near lossless, 3) lossy, 4) mesh reduction, and 5) derived representations. We then survey available techniques in each of these categories, summarize their properties from a practical point of view, and discuss relative merits within a category. We believe, in total, this work will enable simulation scientists and visualization/data analysis scientists to decide which data reduction techniques will be most helpful for their needs.

97 MATHEMATICS AND COMPUTING↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗

A subdermal tagging technique for juvenile sturgeon using a new self-powered acoustic tag

Abstract Background A new technology for a self-powered acoustic tag (SPT) was developed for active tracking of juvenile fish, intended to avoid the typical battery life constraints associated with active telemetry technology. We performed a laboratory study to evaluate a subdermal tagging technique for the SPT and effects of the tag on survival, tag retention, and growth in juvenile white sturgeon ( Acipenser transmontanus ). Results Survival was associated with tag retention. White sturgeon implanted with the SPT ( n = 30) had 93% survival and tag retention by day 28, 67% by day 101, and 38% by day 595 post-tagging. Sturgeon implanted with a passive integrated transponder (PIT) tag only (control group) had 96% survival and tag retention by day 28, and through day 101 post-tagging. Fish in the PIT group were repurposed after day 101, so no comparisons with this group were made at day 595 post-tagging. Specific growth rate (SGR) for fork length was a median of 0.25% day −1 by day 28 for the SPT group, which was significantly lower than the PIT group (median: 0.42% day −1 ; n = 27). The SPT and PIT groups had similar SGR fork length by day 101 post-tagging (0.22 and 0.25% day −1 , respectively). SGR weight was also lower for the SPT group compared to the PIT group on day 28 (1.39 and 2.11% day −1 , respectively), but the difference again dissipated by day 101 (0.79 and 0.88% day −1 , respectively). Conclusion The tagging technique and placement of the SPT allowed the tag to remain upright along the flank of the sturgeon to ensure maximum battery output of the SPT; however, retention rates of the SPT were not ideal. We provided suggestions to improve the tagging technique. Suggestions included tagging fish that are > 400 mm FL, moving the incision location to extend the cavity and create a pocket for the placement of the SPT, and performing a quantitative wound-healing evaluation. Future studies are therefore recommended to evaluate these suggestions.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

ODS Thin-wall Cladding Joining Technique Development

ABSTRACT The oxide dispersion strengthened (ODS) materials are typically fabricated by powder mechanical alloying to form uniform distribution of high concentration nanometer size oxide particles for exceptional high temperature mechanical strength and enhanced radiation tolerance. This report summarizes the recent development on the weld techniques of joining the ODS cladding to the endplug as a part of accident tolerant fuels (ATF) program for both advanced light water reactor (LWR) and advanced fuel cycle (AFC) with fast reactor fuel cladding. It is crucial for the weld of ODS material to maintain the uniform distribution and fine size of oxide particles in the matrix. Pressure Resistance Weld (PRW) is a solid state joining technique without melting therefore a preferred joining technique for ODS materials. Samples joined with PRW were pressure burst tested. Detailed microstructural characterization in this work includes non-destructive 3D x-ray ?m-resolution computer-tomography (?-CT), optical microscopy, SEM/EBSD for grain-orientation-mapping, TEM, STEM/ASTAR for high resolution grain orientation and phase mapping, and APT for high-resolution 3D composition analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-Invasive Biophysical Techniques to Monitor the Structural Plasticity of the Photosynthetic Machinery of Live Diatom Cells

The photosynthetic performance of diatoms depends largely on the organization and structural flexibility of their thylakoid membranes, the densely packed, highly organized membrane vesicles in which light reactions of photosynthesis occur. Different regulatory mechanisms that fine tune the photosynthetic functions affect the organization of the photosynthetic machinery at different levels of structural complexity, from the level of individual protein complexes to the macroarray of membrane proteins and the remodeling of the entire thylakoid membrane system. To monitor these reorganizations, non-invasive techniques are of special value. In this chapter, we focus our attention on three of these techniques, which have been demonstrated to provide unique and useful information on the structure and structural and functional plasticity of live diatom cells: (i) circular dichroism (CD) spectroscopy, which has provided unique information on the chiral (macro-)organization of protein complexes and on their rapid, reversible reorganizations, fine-tuning the light-harvesting processes, as well as on variations in the short-range excitonic interactions in the antenna complexes; (ii) small-angle neutron scattering (SANS), which has been used to determine the periodic organization of the thylakoid membranes and to monitor reversible ultrastructural changes on the time-scale of minutes, induced by variations in the environmental conditions such as changes in temperature or light intensity; and (iii) electrochromic shift absorbance transients (ΔA ECS ), a spectroscopic tool which has been shown to be capable of identifying distinct functional groups of the light-harvesting carotenoid fucoxanthin in different diatoms and in cells exposed to different light intensities. Future use of these techniques will most certainly contribute to the deeper understanding of key regulatory mechanisms of photosynthesis in diatoms.

Szabo, Milan↗

Novel Rapid Screening of Basic Immobilized Amine Sorbent/Catalyst Water Stability by a UV/Vis/Cu 2+ Technique

Abstract Time‐consuming thermogravimetric analysis (TGA) decomposition study is a typical practice to assess the stability of fresh and water‐treated basic immobilized amine sorbents (BIAS)/catalysts. This work presents a faster and more precise spectroscopic UV/Vis/Cu 2+ sorbent screening technique that quantifies aqueous amines washed from the BIAS by using UV‐active amine/Cu 2+ complexes. Six BIAS‐based catalysts, containing different amine species and a crosslinker within silica, were treated with ultrapure water and then analyzed for their CO 2 capture performance and amine leach resistance/stability by using TGA (catalysts, approximately 4 h) and UV/Vis/Cu 2+ techniques (wash solution, few minutes). A comparative analysis revealed that directly quantifying washed amines with UV/Vis/Cu 2+ is 9–127 times more precise than indirect testing of the sorbents by TGA. Similar trends in the H 2 O stability profiles of the catalysts [organic content retained values (OCR)] were reported by both analysis methods, allowing UV/Vis/Cu 2+ to replace TGA for quantifying unstable leached amines. The UV/Vis/Cu 2+ OCR results could be used to predict the CO 2 ‐capture stability profile of the sorbents, confirming the reliability of this technique to rapidly screen catalyst stability and performance.

Wilfong, Walter Christopher↗

Review of deep inspiration breath-hold techniques for the treatment of breast cancer

Radiation treatment to the left breast is associated with increased cardiac morbidity and mortality. The deep inspiration breath-hold technique (DIBH) can decrease radiation dose delivered to the heart and this may facilitate the treatment of the internal mammary chain nodes. The aim of this review is to critically analyse the literature available in relation to breath-hold methods, implementation, utilisation, patient compliance, planning methods and treatment verification of the DIBH technique. Despite variation in the literature regarding the DIBH delivery method, patient coaching, visual feedback mechanisms and treatment verification, all methods of DIBH delivery reduce radiation dose to the heart. Further research is required to determine optimum protocols for patient training and treatment verification to ensure the technique is delivered successfully.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Introducing “ The Integrator ”: A novel technique to monitor environmental flow systems

Abstract We introduce “ The Integrator ,” a novel technique to quantify transport and reaction metrics commonly used to characterize flow systems. This development consists of two products: (1) The Integrator sampling device and (2) its supporting mathematical framework, which is compatible with semi‐continuous sensor data. The use of The Integrator device simplifies the logistics of sample collection and greatly reduces the number of samples needed, making it ideal to characterize systems that are: (1) difficult to access, (2) large and thus intractable or highly heterogeneous, and (3) highly instrumented otherwise but where a more holistic, mechanistic understanding may be gained by monitoring one or more currently untracked elements. We tested and validated The Integrator technique using experimental data collected from a heart rate monitor (high‐quality, high‐frequency data in response to known excitation events) and solute tracer experiments conducted in two contrasting (fourth and seventh order) rivers. In the Supporting Information , we provide details concerning the design of The Integrator device used in our field case studies and provide insight into potential improvements. Despite our case studies focus on the analysis of conservative and reactive transport of solutes in rivers, the principles behind The Integrator technique can be used to monitor water quality in hyporheic zones, aquifers, wetlands, swamps, karsts, oceans, wastewater treatment plants, pipe networks, and air quality. Furthermore, special arrangements of Integrator devices can be used to gather data at spatial and temporal resolutions that are currently unattainable due to high transportation and/or personnel costs.

54 ENVIRONMENTAL SCIENCES↗

Development of a Printable Prill Formulation Technique and Demonstration of Monomodal Prill Size on Compaction Density and Compressive Strength

Polymer-bonded explosive molding powder, or “prills,” are relied on for the fabrication of pressed high explosives since the 1950's. The wet granulation technique, also known as “slurry coating,” that is used to formulate prills, is a complex process that results in polydisperse and variable yields. This makes it difficult to study the mesoscale effect that prills have on the microstructure of a pressed article. The following study introduces a novel approach to energetic granulation that leverages techniques used in the additive manufacturing of paste-like energetic materials. This extrusion granulation, or prill printing technique, makes it possible to tailor the sizes and shapes of prills, allowing for their morphological influences to be studied in a controlled manner. The following work details the fabrication and characterization of four monomodal size lots of prills using an inert formulation (95 wt.% melamine, 5 wt.% polymer binder). Prills from each size lot were die-pressed using a fixed recipe to investigate how prill size impacts compaction density and therefore compressive strength. It was found that larger prills influence the pressing density by creating larger defects within the microstructure of a pressed article, resulting in a decrease in compressive strength.

direct ink write↗